• Title/Summary/Keyword: Sensor diagnostics

Search Result 88, Processing Time 0.025 seconds

Cutting force estimation using spindle and feeddrive motor currents in milling processes (밀링공정에서 이송모터와 주축모터의 전류신호를 이용한 절삭력 추정)

  • 김승철;정성종
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1407-1410
    • /
    • 1997
  • Advanced sensor design and filtering technology have been studied to obtain information for condition monitoring and diagnostics inmachining processes. To develope and economic monitoring system in end milling processes, indirect and reliable type of cutting force estimators were required. In this paper, an estimation method of cutting forces during end milling processes was studied through the measurement of current signals obtained from spindle and feeddrive motors. Cutting force and torque models were derived from the cutting geometry in down milling processes. Relationships between motor currents and cutting forces were also developed in the form of AC and DC components from the developed force models. The validity of the cutting force estimator was confirmed by the experiments under various cutting conditions.

  • PDF

Detection of Pesticide Thiram in Plant Leafs Using Voltammetric at Nanotube Electrode (나노튜브전극을 사용한 전압전류법에 의한 식물잎에서 살충제 검출)

  • Lee, Chang-Hyun;Ly, Suw-Young
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1335-1341
    • /
    • 2010
  • Voltammetric diagnostics of pesticide thiram was studied in plant leafs in vivo fluid with DNA immobilized on a carbon nanotube electrode (DCE). Sensor properties of carbon nanotube (CE) and DNA immobilized nanotube were compared. DCE was more effective than CE in target detecting. The parameters such as pH strength, stripping accumulation, amplitude, and increment potential were examined to find the optimum condition for detection of pesticide thiram in a sesame leaf. The optimized conditions were as follows 550 Hz frequency, 0.15 V amplitude, 0.005 V increment potential, -1.2 V initial potential, 4.78 pH, 500 sec accumulation time. Under optimum condition, the detection limit of thiram was attained at 0.01ng/L.

The Misfire Detection and Intensity Interpretation using Breakdown Voltage Characteristics (브레이크다운전압 특성을 이용한 엔진실화의 검출 및 강도해석)

  • 고용수;박재근;조민석;황재원;채재우
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.6
    • /
    • pp.42-48
    • /
    • 1999
  • Engine misfire causes of the negative effect on exhaust emission such as HC, CO, and NOX . Moreover, it causes damage to the three-way-catalyst(TWC) system permanently. The crankshaft velocity fluctuation(CVF) method has been applied for the real cars as misfire detection system usually, which utilizes the crank angle sensor input to calculate the variation of the crankshaft rotational speed. But this approach has the limit due to the fact that three could be problem under certain engine condition like as deceleration or high speed condition . Therefore the development of new methods are requested today. This study introduced the new method of misfire detection using breakdown voltage(BDV) characteristics between spark plug electrouds.

  • PDF

On-Line Diagnostics and Monitoring of Distribution Panel Using IR-Sensor (광온도센서를 이용한 분전반의 온라인 진단 및 감시)

  • Yun, Ju-Ho;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2110-2111
    • /
    • 2008
  • Continuous on-line temperature monitoring allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

Development of Diagnostic Expert System for Rotating Machinery with Journal Bearing-Research on the Diagnosis of the Nonlinear Characteristics of Rotor System (저어널 베어링으로 지지된 회전축의 이상상태 진단을 위한 진단 전문가 시스템의 개발-로타시스템의 비선형 특성 진단을 위한 연구)

  • 유송민;김영진;박상신
    • Tribology and Lubricants
    • /
    • v.17 no.2
    • /
    • pp.153-161
    • /
    • 2001
  • The development of techniques in diagnosing the state of the system is one of the essential tools in establishing the automation and unmanned manufacturing system for the realization of CIM/FMS in the fields. In this paper, we developed various diagnostic schemes for the journal bearing supported rotor system. Up to now, vibration of the shaft, measurement of the displacement and the temperature have been used for diagnostic tools, however, the statistical features only could not differentiate the state from states. Thus, we identified the sensor data f3r the steady state in the signal processing and then applied the fuzzy c-mean technology to cope with the nonlinear characteristics of the system. This will, in return, establish a possible diagnostic system for the rotor system in the fields.

Nanobiotechnology, Today and Tomorrow (나노바이오공학의 오늘과 내일)

  • Lee, Chang-Soo;Park, Hyun-Kyu;Kim, Moon-Il
    • Journal of Plant Biotechnology
    • /
    • v.33 no.3
    • /
    • pp.223-231
    • /
    • 2006
  • Nanobiotechnology, the interdisciplinary area at the crossroad of biotechnology and nanoscience, combines contributions from molecular and cell biology, chemisty, material science, and physics in an attempt to understand the behavior of nanobiomaterials, their development and applications. At present, nanobiotechnology is believed to hold great promise for improving health and prolonging life, faciliating biomarker discovery, molecular diagnostics, discovery of novel drugs and drug delivery, which are important basic components of biomedical science. In the recent trend of nanobiotechnology, this review is intended to provide a better understanding of nanobiotechnology in its applications and perspectives, separating this integration technology into three parts such as nanobiochip/sensor, nanobiomaterials, and nanobioanalysis in order to hopefully gain insights into why size matters, how nano-materials and -devices can be engineered.

Species Concentration Measurement Technique Using Wavelength Modulation Absorption Spectroscopy (파장변조 광흡수 분광법을 이용한 농도 계측 기법)

  • Ahn, J.H.;Kim, Y.M.
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.67-76
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, reasonable cost, robustness, and ease of use. In addition, diode lasers we fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develop new gas sensing system and to verify feasibility of this system. Wavelength modulation spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

A Decision Support Model for Intelligent Facility Management through the Digital Transformation

  • Lee, Junsoo;Kim, Kang Hyun;Cha, Seung Hyun;Koo, Choongwan
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.485-492
    • /
    • 2020
  • Information on the energy consumption of buildings that can be obtained through conventional methods is limited. Therefore, this study aims to develop a model that can support decision making about building facility management through digital transformation technologies. Through the IoT sensor, the building's energy data and indoor air quality data are collected, and the monitored data is visualized through the ELK Stack and produced as a dashboard. In addition, the target building is photographed with a 360-degree camera and maps using a tool to create a 360-degree tour. Using such digital transformation technologies, users of buildings can obtain various information in real time without visiting buildings directly. This can lead to changes in actions or actions for building management, supporting facility management decisions, and consequently reducing building energy consumption.

  • PDF

Model-based localization and mass-estimation methodology of metallic loose parts

  • Moon, Seongin;Han, Seongjin;Kang, To;Han, Soonwoo;Kim, Munsung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.846-855
    • /
    • 2020
  • A loose part monitoring system is used to detect unexpected loose parts in a reactor coolant system in a nuclear power plant. It is still necessary to develop a new methodology for the localization and mass estimation of loose parts owing to the high estimation error of conventional methods. In addition, model-based diagnostics recently emphasized the importance of a model describing the behavior of a mechanical system or component. The purpose of this study is to propose a new localization and mass-estimation method based on finite element analysis (FEA) and optimization technique. First, an FEA model to simulate the propagation behavior of the bending wave generated by a metal sphere impact is validated by performing an impact test and a corresponding FEA and optimization for a downsized steam-generator structure. Second, a novel methodology based on FEA and optimization technique was proposed to estimate the impact location and mass of a loose part at the same time. The usefulness of the methodology was then validated through a series of FEAs and some blind tests. A new feature vector, the cross-correlation function, was also proposed to predict the impact location and mass of a loose part, and its usefulness was then validated. It is expected that the proposed methodology can be utilized in model-based diagnostics for the estimation of impact parameters such as the mass, velocity, and impact location of a loose part. In addition, the FEA-based model can be used to optimize the sensor position to improve the collected data quality in the site of nuclear power plants.

A STUDY ON A CATALYTIC CONVERTER OBD BEFORE LIGHT-OFF

  • Yun, Seung-Won;Son, Geon-Seog;Lee, Kwi-Young
    • International Journal of Automotive Technology
    • /
    • v.3 no.1
    • /
    • pp.33-40
    • /
    • 2002
  • Increasingly stringent emission regulations of EU and CARB (California Air resource Board) require mandatory OBD (On Board Diagnostics) far the catalytic converters of a vehicle. It demands that MIL(Malfunction Indication Light) should be tuned on to inform the driver of catalytic converter failures. Currently dual oxygen sensor method Is widely used for the converter OBD. However, since it works only alter converter light-off, it has a serious limitation when applied to TLEV or more stringent emission regulations where more than 85% of total emission is coming out before converter light-off. In addition, a recent development in catalyst material. coating technology and additive catalysts leads to a much improved OSC (Oxygen Storage Capacity) after converter light-off, current methods are very difficult to determine levels of converter aging. Therefore, it is desired to develop an OSC detecting method before converter light-off to diagnose converter failures with higher reliability. In this study, OSCs of converters are measured by an absolute measuring method and a dynamic measuring method, and some of fundamental ideas are suggested about converter OBD before converter light-off. The converters are aged with two different aging methods; those are a furnace aging and an engine bench aging: to represent aging conditions in actual field applications. Dual oxygen sensor method at the lower temperature than light-off is also studied at a model gas bench with the converters. It is fecund that there is a certain point in temperature lower than light-off where difference due to aging level becomes maximum, thus a proper dynamic method to effectively monitor catalytic converters could be implemented fur the range lower than light-off temperatures. With this result, the aging level of converters is examined at an engine bench.