• Title/Summary/Keyword: Sensor configuration

Search Result 479, Processing Time 0.03 seconds

Topology Optimization of a Bias Magnetic Field for the Performance Improvement of a Magnetostrictive Sensor (마그네토스트릭션 센서 성능 향상을 위한 바이어스 자기장의 위상 최적설계)

  • Cho, Seung-Hyun;Kim, Youngkyu;Kim, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.554-558
    • /
    • 2002
  • A magnetostrictive sensor is used to measure stress waves propagating in a ferromagnetic cylinder without physical contact. The performance of a magnetostrictive sensor is affected most significantly by the bias magnetic field applied around the measurement location. The goal of this paper is to carry out the topology optimization of the bias magnet and yoke assembly to maximize the sensor output for traveling bending waves. We will use the multi-resolution topology optimization strategy to find the assembly of the bias magnet and the yoke that is easy to realize. The effectiveness of the present design is confirmed by an actual measurement of the sensor signal with the proposed bias magnet and yoke configuration.

  • PDF

Self-Organization Routing Protocol supporting Node moving in Wireless Sensor Network (무선 센서 네트워크에서의 노드 이동을 지원하는 자가 구성 라우팅 프로토콜)

  • Kim, Yong;Jang, Kyung-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.1035-1037
    • /
    • 2009
  • Common to use fixed-node sensor network and wireless sensor networks, unlike the recent move of the node happens frequently. These wireless sensor networks by taking into account the mobility of sensor nodes dynamically self-configurable routing protocol is required. In this paper, a fixed-node configuration and energy efficiency in the self-LEACH protocol is based on the useful movement of the nodes of the cluster is dynamically self-configuring routing protocols offer M-LEACH.

  • PDF

Avoiding Indefiniteness in Criteria for Maximum Likelihood Bearing Estimation with Arbitrary Array Configuration

  • Suzuki, Masakiyo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1807-1810
    • /
    • 2002
  • This paper presents a technique for avoid- ing indefiniteness in Maximum Likelihood (ML) criteria for Direction-of-Arrival (DOA) finding using a sensor ar- ray with arbitrary configuration. The ML criterion has singular points in the solution space where the criterion becomes indefinite. Solutions fly iterative techniques for ML bearing estimation may oscillate because of numerical instability which occurs due to the indefiniteness, when bearings more than one approach to the identical value. The oscillation makes the condition for terminating iterations complex. This paper proposes a technique for avoiding the indefiniteness in ML criteria.

  • PDF

The Development of Distribution Transformer Remote Monitoring System using CATV Cable (CATV회선을 이용한 배전용 변압기 부하의 원격감시시스템 개발)

  • Park, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.939-942
    • /
    • 1998
  • This paper presents the process on the construction for the remote distribution pole transformer monitoring system. Especially, this system uses CATV cable as communication media which is located in KEPCO's main distribution line. It has four major components such as sensor for measuring secondary voltage and currents of distribution transformer, RF modem for data modulating/de-modulating, communication media for sending/receiving of data, and pc server for monitoring the results of sensing or computing information. This paper also describes the configuration of these each component's configuration and its functions.

  • PDF

A Compact Ka-Band Doppler Radar Sensor for Remote Human Vital Signal Detection

  • Han, Janghoon;Kim, Jeong-Geun;Hong, Songcheol
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.4
    • /
    • pp.234-239
    • /
    • 2012
  • This paper presents a compact K-band Doppler radar sensor for human vital signal detection that uses a radar configuration with only single coupler. The proposed radar front-end configuration can reduce the chip size and the additional RF power loss. The radar front-end IC is composed of a Lange coupler, VCO, and single balanced mixer. The oscillation frequency of the VCO is from 27.3 to 27.8 GHz. The phase noise of the VCO is -91.2 dBc/Hz at a 1 MHz offset frequency, and the output power is -4.8 dBm. The conversion gain of the mixer is about 11 dB. The chip size is $0.89{\times}1.47mm^2$. The compact Ka-band Doppler radar system was developed in order to demonstrate remote human vital signal detection. The radar system consists of a Ka-band Doppler radar module with a $2{\times}2$ patch array antenna, baseband signal conditioning block, DAQ system, and signal processing program. The front-end module size is $2.5{\times}2.5cm^2$. The proposed radar sensor can properly capture a human heartbeat and respiration rate at the distance of 50 cm.

Unmanned Vehicle System Configuration using All Terrain Vehicle

  • Moon, Hee-Chang;Park, Eun-Young;Kim, Jung-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1550-1554
    • /
    • 2004
  • This paper deals with an unmanned vehicle system configuration using all terrain vehicle. Many research institutes and university study and develop unmanned vehicle system and control algorithm. Now a day, they try to apply unmanned vehicle to use military device and explore space and deep sea. These unmanned vehicles can help us to work is difficult task and approach. In the previous research of unmanned vehicle in our lab, we used 1/10 scale radio control vehicle and composed the unmanned vehicle system using ultrasonic sensors, CCD camera and kinds of sensor for vehicle's motion control. We designed lane detecting algorithm using vision system and obstacle detecting and avoidance algorithm using ultrasonic sensor and infrared ray sensor. As the system is increased, it is hard to compose the system on the 1/10 scale RC car. So we have to choose a new vehicle is bigger than 1/10 scale RC car but it is smaller than real size vehicle. ATV(all terrain vehicle) and real size vehicle have similar structure and its size is smaller. In this research, we make unmanned vehicle using ATV and explain control theory of each component

  • PDF

Energy Efficient Cluster Head Election Algorithm Considering RF-Coverage (RF-Coverage를 고려한 에너지 효율적인 클러스터 헤드 선출 알고리즘)

  • Lee, Doo-Wan;Han, Youn-Hee;Jang, Kyung-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.993-999
    • /
    • 2011
  • In WSN, at the initial stage, sensor nodes are randomly deployed over the region of interest, and self-configure the clustered networks by grouping a bunch of sensor nodes and selecting a cluster header among them. Specially, in WSN environment, in which the administrator's intervention is restricted, the self-configuration capability is essential to establish a power-conservative WSN which provides broad sensing coverage and communication coverage. In this paper, we propose a communication coverage-aware cluster head election algorithm for Herearchical WSNs which consists of communication coverage-aware of the Base station is the cluster head node is elected and a clustering.

Chip-scale Temperature-compensated Superstructured Waveguide Bragg Grating Based Multiparametric Sensor

  • Vishwaraj, Naik Parrikar;Nataraj, Chandrika Thondagere;Jagannath, Ravi Prasad Kogravalli;Gurusiddappa, Prashanth;Talabattula, Srinivas
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.293-301
    • /
    • 2020
  • In this paper we propose and theoretically analyze a monolithic multiparametric sensor consisting of a superstructure of surface-relief waveguide Bragg gratings (WBGs), a micro-machined diaphragm, and a cantilever beam. Diaphragms of two different configurations, namely circular and square, are designed and analyzed separately for pressure measurement. The square diaphragm is then selected for further study, since it shows relatively higher sensitivity compared to the circular one, as it incurs more induced stress when any pressure is applied. The cantilever beam with a proof mass is designed to enhance the sensitivity for acceleration measurement. A unique mathematical method using coupled-mode theory and the transfer-matrix method is developed to design and analyze the shift in the Bragg wavelength of the superstructure configuration of the gratings, due to simultaneously applied pressure and acceleration. The effect of temperature on the wavelength shift is compensated by introducing another Bragg grating in the superstructure configuration. The measured sensitivities for pressure and acceleration are found to be 0.21 pm/Pa and 6.49 nm/g respectively.

Current Developments of Biomedical Mobile Devices for Ubiquitous Healthcare (u-Healthcare를 위한 바이오 단말기의 개발 현황)

  • Lee, Tae-Soo;Hong, Joo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.3
    • /
    • pp.185-190
    • /
    • 2009
  • Biomedical mobile devices for ubiquitous healthcare consist of biomedical sensors and communication terminal. They have two types of configuration. One is the sensor-network type device using wired or wireless communication with intelligent sensors to acquire biomedical data. The other is the sensor embedded type device, where the data can be acquired directly by itself. There are many examples of sensor network type, such as, fall detection sensor, blood glucose sensor, and ECG sensors networked with commercial PDA phone and commercial phone terminal for ubiquitous healthcare. On the other hand, sensor embedded type mounts blood glucose sensor, accelerometer, and etc. on commercial phone. However, to enable true ubiquitous healthcare, motion sensing is essential, because users go around anywhere and their signals should be measured and monitored, when they are affected by the motion. Therefore, in this paper, two biomedical mobile devices with motion monitoring function were addressed. One is sensor-network type with motion monitoring function, which uses Zigbee communication to measure the ECG, PPG and acceleration. The other is sensor-embedded type with motion monitoring function, which also can measure the data and uses the built-in cellular phone network modem for remote connection. These devices are expected to be useful for ubiquitous healthcare in coming aged society in Korea.

Model-based Integrated Development Tool for the Development of Applications in Ubiquitous Sensor Network (유비쿼터스 센서 네트워크에서 응용 프로그램 개발을 위한 모델 기반 통합 개발 도구)

  • Chong, Ki-Won;Kim, Ju-Il;Lee, Woo-Jin
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.13 no.7
    • /
    • pp.442-453
    • /
    • 2007
  • A model-based integrated development tool for the development of USN application programs is proposed in this paper. The proposed tool has been implemented as a plug-in for Eclipse platform. The tool consists of Graphical User Interface, Modeler, Configuration Information Generator, Validity Checker, Source Code Generator and Templates Storage. Developers can implement USN applications from models of sensor networks using the tool. The developer can implement USN applications by automatic generation of execution code of each node in the sensor network after he/she designs a model of the sensor network. The configuration information of each node is automatically generated from the validated USN model. Then, the execution code is automatically generated using the configuration information and the predefined templates. Through the tool of this paper, developers can easily implement valid USN applications even if they do not know the details of low-level information. Also, a large number of application programs can be generated at once because application programs are generated from sensor network model instead of models of applications. Accordingly, the development effort of USN applications will be decreased and developers can consistently construct USN applications from USN models using the proposed tool.