• Title/Summary/Keyword: Sensor Sensitivity

Search Result 1,900, Processing Time 0.028 seconds

Sensitivity Analysis of Fiber Optic Hydrophone for an End-Capped Hollow Cylinder (끝단이 막힌 중공 원통형 광섬유 하이드로폰의 감도 해석)

  • 이종길;윤형규;서인창
    • Journal of KSNVE
    • /
    • v.6 no.4
    • /
    • pp.475-479
    • /
    • 1996
  • Recently, fiber optic hydrophone is a subject which has attracted as a underwater acoustic sensor. In this paper, a length of optical fiber is bonded to an end-capped hollow cylinder of some elastic material, e. g. aluminum and glass-pyres. The normalized sensitivity is derived according to the direction of polarization. Derived sensitivity equations are simulated for two different mandrel materials. The results are also compared to the McMahon's results which calculated for an average Pockel coefficient. Based on the numerical simulation normalized sensitivity is propotional to the inner to outer diameter ratio.

  • PDF

Sensitivity of an Anisotropic Magnetoresistance Device with Different Bias Conditions

  • Kim, T.S.;Kim, K.C.;Kim, Kibo;K. Koh;Y.J. Song;Song, Y.S.;Suh, S.J.;Kim, Y.S.
    • Journal of Magnetics
    • /
    • v.6 no.1
    • /
    • pp.36-41
    • /
    • 2001
  • A micromagnetic model and a single-domain model simulation programs were used to analyze the sensitivity of a $20\mu m\times 60\mu m \times 1000{\AA}$ permalloy strip as a magnetoresistance sensor with bias fields of various directions and magnitudes. The micromagnetic model agrees with the measured sensitivity data better than the single-domain model. The data show the highest peak sensitivity with the bias field at 90$^{\circ}$to the current. The peak sensitivity decreases and the peak broadens as the bias angle decreases. The simulation using the micromagnetic model shows that a bias angle smaller than 90$^{\circ}$eads to magnetization patterns which are free from closure domains or vertices over a wider range of bias fields.

  • PDF

Intravenous Infusion Monitoring Sensor Based on Longitudinal Electric Field Proximity Sensing Technique (종방향 전기장 근접 감지 방식 수액 주입 측정 센서)

  • Kim, Young Cheol;Ahmad, Sheikh Faisal;Kim, Hyun Deok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.101-106
    • /
    • 2017
  • A novel intravenous (IV) infusion monitoring sensor is presented to measure the drop rate in the drip chamber of an IV infusion set. It is based on a capacitive proximity sensor and detects the variation of the longitudinal electric field induced by the drop falling into the drip chamber. Unlike the conventional capacitor sensor with two semi-cylindrical conductor plates, the proximity sensor for IV monitoring is composed of a pair of conductor rings which are mounted on the outer surface of the drip chamber with a specific gap between them. The characteristics of the proximity sensor for IV monitoring were investigated through three dimensional electrostatic simulations. It showed quite superior performances in comparison with the conventional capacitor sensor. Especially, the proposed proximity sensor exhibits consistent sensitivity regardless of its mounting position on the drip chamber, operates normally though the drip chamber is tilted and shows robustness to the changes of the drop size and the drip factor of the IV infusion set. Thus, the proximity sensor for IV monitoring is more suitable for use in actual environment of IV therapy compared with the conventional capacitor sensor.

Improved Resolution of Paper-based Sensor for Proline Detection by Low-temperature Drying of Ninhydrin Solution (닌히드린 용액의 저온 건조에 의한 프롤린 검출을 위한 종이기반 센서의 분해능 개선)

  • Ji-Kwan, Kim;Young-Soo, Choi
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.428-432
    • /
    • 2022
  • In this study, we describe the improvement of the resolution of a paper-based sensor by fabricating a high-concentration ninhydrin part using a low-temperature drying method to detect proline with high resolution. In the conventional paper-based sensor for detecting proline, the ninhydrin part is fabricated at room temperature, and in this process, the ninhydrin solution spreads around the ninhydrin part. Therefore, the concentration of the ninhydrin part becomes lower than that of the applied solution, lowering the resolution of the sensor. The proposed paper-based sensor better improved the sensitivity of the sensor compared to the existing sensor by fabricating a high-concentration ninhydrin part through drying the ninhydrin solution using a low-temperature drying method. Owing to the experiment, the intensity of the green color of the paper-based sensor with the integrated ninhydrin part fabricated at 10 ℃ is approximately 20% lower than the paper-based sensor with an integrated ninhydrin part fabricated at room temperature, indicating better sensor resolution. Therefore, the paper-based sensor with an integrated ninhydrin part fabricated at a high concentration could be useful for diagnosing drought.

Characteristics Investigation and Design of the Mandrel for Fiber Optic Acoustic Sensor (광섬유 음향 센서용 맨드릴 설계 및 특성 연구)

  • Lee, Jongkil;Ha, Tae-Hyun;Lee, June-Ho
    • 대한공업교육학회지
    • /
    • v.34 no.2
    • /
    • pp.331-345
    • /
    • 2009
  • In this research Sagnac interferometer three different types of mandrel are suggested and this fiber optic sensor is using in monitoring of electric transformer. Vibration characteristics of those mandrels were analyzed and finally more sensitivity mandrel are suggested. Three different mandrels using in fiber optic sensor are hollow cylinder with outer bump, pure hollow cylinder, hollow cylinder with inner bump. Natural frequencies and mode shapes are investigated using finite element method. Mode shape are considered at the frequency range from 2 kHz to 20 kHz. Fundamental dimensions of the hollow cylinder type's mandrel are 30 mm in outer diameter, 50 mm in length, 1 mm in cylinder thickness, $2mm{\times}2mm$ in bump size. Based on the finite element results, when the outer acoustic frequency is near 11 kHz outer bump type and hollow cylinder can get higher sensitivity. Near 17 kHz outer bump and inner bump mandrel can get higher sensitivity. Near 20 kHz hollow cylinder and inner bump mandrel is useful. This results can be applied to design of fiber optic sensor using in monitoring the electrical transformer. Several MHz of outer acoustic frequency can be easily detected using more sensitive mandrel in pursuing expand this technique.

A Study on an Activated Carbon Coated Sensor for the Detection of Marine Pollution (해양오염 감지를 위한 활성탄 코팅 센서에 관한 연구)

  • 최광재;김영한
    • Journal of Korean Port Research
    • /
    • v.14 no.3
    • /
    • pp.373-378
    • /
    • 2000
  • Oil spill in sea water is the most frequent and significant problem of marine pollution. As an early detection sensor of the pollution, an activated carbon coated quartz crystal is prepared and examined for its performance of detection sensitivity and stability. Powdered activated carbon and phenol resin is coated on the surface of the sensor and the sensor is baked for an hour. Adsorption of acetone dissolved in water and salt water is measured using frequency shift of quartz crystal at different concentrations of solute material. The outcome indicates that the sensor preparation is adequate and the measurement of solute concentration is stable and sensitive enough to be implemented on the monitoring of solute concentration is stable and sensitive enough to be implemented in the monitoring of organic pollution of sea water.

  • PDF

The Parameter Identification for Localization Scheme of the Optics-Based Micro Sensor Node (광신호 기반의 마이크로 센서 노드 위치 인식 시스템을 위한 파라미터 식별)

  • Jeon, Ji-Hun;Lee, Min-Su;Park, Chan-Gook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2013
  • In this paper, the parameter identification for localization scheme for the optics-based micro sensor node is conducted. We analyzed short measurement range problem which can be occurred in optical based micro sensor node localization method using a time of flight. And we set up the theory for distance and maximum reflected laser power to overcome the problem by identifying hardware parameters like laser power, effective area of MEMS CCR, sensitivity of photodetector, and so on. Experimental results of measurement of maximum reflected laser power were compared with results of the theory. By using the theory, we can identify hardware parameters of localization scheme to measure particular position of the optics-based micro sensor node.

Thermal Strain and Temperature Measurements of Structures by Using Fiber-Optic Sensors (광섬유 센서를 이용한 구조물의 열변형 및 온도 측정)

  • 강동훈;강현규;류치영;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.184-189
    • /
    • 2000
  • Two types of fiber-optic sensors, EFPI(extrinsic Fabry-Perot interferometer) and FBG(fiber Bragg grating), have been investigated for measurement of thermal strain and temperature. The EFPI sensor is only for measurement of thermal strain and the FBG sensor is for simultaneous measurement of thermal strain and temperature. FBG temperature sensor was developed to measure strain-independent temperature. This sensor configuration consists of a single-fiber Bragg grating and capillary tube which makes it isolated from external strain. This sensor can then be used to compensate for the temperature cross sensitivity of a FBG strain sensor. These sensors are demonstrated by embedding them into a graphite/epoxy composite plate and by attaching them on aluminum rod and unsymmetric graphitelepoxy composite plate. All the tests were conducted in a thermal chamber with the temperature range $20-100^{\circ}C$. Results of strain measurements by fiber-optic sensors are compared with that from conventional resistive foil gauge attached on the surface.

  • PDF

Fiber-optic rotation angle sensor based on fused fiber coupler (융착 광섬유 커플러를 이용한 회전 각도 센서)

  • Kim, Kwang-Taek;Cho, Kyu-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.62-66
    • /
    • 2010
  • We have proposed and demonstrated a rotation angle sensor based on the stress -optic effect of a fused fiber coupler whose transmission spectrum is altered by the torsional stress. The peak of transmission spectrum was shifted to longer wavelength region with rotation of the coupler. The rotation angle sensor revealed reproducibility and symmetric behavior with respect to the rotation direction. The sensitivity of the sensor was 0.367 [nm/degee].

Design and fabrication of micro force sensor using MEMS fabrication technology (MEMS 제작기술을 이용한 미세 힘센서 설계 및 제작)

  • 김종호;조운기;박연규;강대임
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.497-502
    • /
    • 2002
  • This paper describes a design methodology of a tri-axial silicon-based farce sensor with square membrane by using micromachining technology (MEMS). The sensor has a maximum farce range of 5 N and a minimum force range of 0.1N in the three-axis directions. A simple beam theory was adopted to design the shape of the micro-force sensor. Also the optimal positions of piezoresistors were determined by the strain distribution obtained from the commercial finite element analysis program, ANSYS. The Wheatstone bridge circuits were designed to consider the sensitivity of the force sensor and its temperature compensation. Finally the process for microfabrication was designed using micromachining technology.

  • PDF