• 제목/요약/키워드: Sensor Sensitivity

검색결과 1,898건 처리시간 0.028초

산화아연 나노구조 박막의 일산화탄소 가스 감지 특성 (CO Gas Sensing Characteristics of Nanostructured ZnO Thin Films)

  • 웬래훙;김효진;김도진
    • 한국재료학회지
    • /
    • 제20권5호
    • /
    • pp.235-240
    • /
    • 2010
  • We investigated the carbon monoxide (CO) gas-sensing properties of nanostructured Al-doped zinc oxide thin films deposited on self-assembled Au nanodots (ZnO/Au thin films). The Al-doped ZnO thin film was deposited onto the structure by rf sputtering, resulting in a gas-sensing element comprising a ZnO-based active layer with an embedded Pt/Ti electrode covered by the self-assembled Au nanodots. Prior to the growth of the active ZnO layer, the Au nanodots were formed via annealing a thin Au layer with a thickness of 2 nm at a moderate temperature of $500^{\circ}C$. It was found that the ZnO/Au nanostructured thin film gas sensors showed a high maximum sensitivity to CO gas at $250^{\circ}C$ and a low CO detection limit of 5 ppm in dry air. Furthermore, the ZnO/Au thin film CO gas sensors exhibited fast response and recovery behaviors. The observed excellent CO gas-sensing properties of the nanostructured ZnO/Au thin films can be ascribed to the Au nanodots, acting as both a nucleation layer for the formation of the ZnO nanostructure and a catalyst in the CO surface reaction. These results suggest that the ZnO thin films deposited on self-assembled Au nanodots are promising for practical high-performance CO gas sensors.

고온초전도체 in-situ ramp-edge 형태의 조셉슨 접합 제작 및 특성 (Fabrication and Characterization of High Temperature in-situ Ramp-edge Type Josephson Junction)

  • 허윤성;김진태;황윤석;이순걸;박광서;김인선;박용기;박종철
    • 한국재료학회지
    • /
    • 제8권3호
    • /
    • pp.263-267
    • /
    • 1998
  • 본 연구에서는 금속 칼날 마스크와 펄스형 레이저 증착장치를 이용하여 $YBa_2Cu_3O_{7-\delta}$/$SrTiO_{3}$/$YBa_2Cu_3O_{7-\delta}$ 다층박막 형태의 In-situ SIS ramp dege 형태의 접합을 제작하였으며, 이의 특성을 조사하였다. 접합은 RSJ 형태의 전류-전압 특성ㅇ르 나타내고 있으며, 온도 변화에 따른 접합의 normal resistance는 약 $18 \omega$으로 온도에 무관하게 일정한 값을 나타내었다. 접합형태를 이용하여 감도(transfer function, dV/$d\Phi$)가 약 $22\mu$V/$\Phi_{0}$인 dc-SQUID센서를 제작하였으며, in-situ SIS ramp edge 형태의 접합이 센서로의 응용가능성을 충분히 가지고 있음을 보여 주었다.

  • PDF

살균제 Iprovalicarb 잔류물의 신속한 검출을 위한 바이오센서 (A Biosensor for the Rapid Detection of the Fungicide Iprovalicarb Residuess)

  • 조한근;김운호;경기성;이은영
    • Journal of Biosystems Engineering
    • /
    • 제32권6호
    • /
    • pp.440-447
    • /
    • 2007
  • In this study, a biosensor was developed using an enzyme-linked immunosorbent assay (ELISA) to rapidly measure the fungicide iprovalicarb residues in agricultural products. The biosensor was designed to include micro-pumps and solenoid valves for fluid transport, a spectrophotometer cuvet as a reaction chamber, a photodiode with a light-emitting diode for optical density measurement, and a control microcomputer to implement assay. The rate of change in optical density of the cuvet was read as final signal output. Micro-pumps were evaluated to investigate their delivery capability, the highest values of the error and the coefficient of variation were 4.3% and 4.6% respectively. As the incubation period was reduced from 15 minutes to 11 minutes to shorten the total processing time, the sensor sensitivity was decreased as the antibody dilution ratio was reduced to a half. The maximum usable period of the coated cuvet was found to be two days with 1% error limit. To predict the concentration of the iprovalicarb residue in agricultural products, a linear calibration model was obtained with r-square values of 0.992 for potato and 0.985 for onion. In validation test for the samples of potatoes and onions against the high performance liquid chromatography, very high correlation values were obtained as 0.996 and 0.993 respectively. Using the cuvet immobilized with antigen, it took 21-minutes for the biosensor to complete the measuring process of the iprovalicarb residues.

Comparison with Threshold Limit Value (TLV) of Menthol Cigarettes between Expert and Consumer Panel

  • 이승용;이환우;김영호
    • 한국연초학회지
    • /
    • 제28권1호
    • /
    • pp.58-66
    • /
    • 2006
  • Threshold limit value (TLV) test between expert and consumer panel was conducted about absolute, recognition and difference threshold respectively. And we tried to suggest appropriate and minimum acceptable menthol concentration level by consumer panel. Determination of threshold value was based on ASTM E 679-79 method by forced-choice ascending concentration series. In addition, a semi-ascending paired difference method was referred to conduct test. The group threshold value was determined as the value of geometric mean individual threshold. The smokers were dividend by two groups, trained and consumer panel. Trained panel was selected according to sensitivity to menthol discrimination. Consumer panel wasrecruited in proportion as population ratios including female smokers. They were all over twenty years old volunteers and summed up thirty four persons. In terms of sensor evaluation, overall difference test with seven-category scale by both trained and consumer panelists were done. On judging correct or incorrect answer, two by three cut-off levels applied to. Every test was conducted with two sessions, before smoking and during smoking period. And, only two samples served each paneI per test with regard to sensory fatigue and reliable results. All tests were replicated, and in total 32 times per panelist. In conclusion, the recognition threshold about consumer and expert panel was 358 ppm/cig. and 276 ppm/cig. in separately. Besides, absolute and difference thresholds were obtained also. And, we conduct difference threshold test with two different ways, upward and downward. And, The results of each method were 246, 195 ppm/cig., 1414, 1336 ppm/cig. and 1047, 972 ppm/cig.

II-VI족 화합물 반도체의 결정성장 및 센서 개발에 관한 연구 (Crystal Growth Sensor Development of II-VI Compound Semiconductor : CdS)

  • D.I. Yang;Y.J. Shin;S.Y. Lim;Y.D. Choi
    • 한국진공학회지
    • /
    • 제1권1호
    • /
    • pp.126-133
    • /
    • 1992
  • E-Beam 기법을 이용하여 증착시킨 Ag doped CdS 박막은 육방정계이고 공기, Ar 분위기에서 $^550{\circ}C$로 열처리한 결과 grain size가 1$mu extrm{m}$ 정도로 성장되었고, Van Der Pauw 방법으로 구한 Hall data로부터 CdS crystal은 n형 반도체이고 상온에서의 carrier 농 도는 2.7 $\times$ 1011cm-3이고 Hall mobility는 5.8 $\times$ 102cm2V-1sec-1정도임을 알 수 있었다. CdS : Ag 박막의 PL spectra는 Gaussian curve를 보여주었고, spectra peak는 파장이 520nm 근처에 위치하고 있으며, CdS : Ag 박막에서의 광전류(pc)와 암전류(dc)의 ratio(pc/dc)는 공기 중에서 열처리한 시료의 값이 크다는 것을 알 수 있었다.

  • PDF

Label-free Femtomolar Detection of Cancer Biomarker by Reduced Graphene Oxide Field-effect Transistor

  • Kim, Duck-Jin;Sohn, Il-Yung;Jung, Jin-Heak;Yoon, Ok-Ja;Lee, N.E.;Park, Joon-Shik
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.549-549
    • /
    • 2012
  • Early detection of cancer biomarkers in the blood is of vital importance for reducing the mortality and morbidity in a number of cancers. From this point of view, immunosensors based on nanowire (NW) and carbon nanotube (CNT) field-effect transistors (FETs) that allow the ultra-sensitive, highly specific, and label-free electrical detection of biomarkers received much attention. Nevertheless 1D nano-FET biosensors showed high performance, several challenges remain to be resolved for the uncomplicated, reproducible, low-cost and high-throughput nanofabrication. Recently, two-dimensional (2D) graphene and reduced GO (RGO) nanosheets or films find widespread applications such as clean energy storage and conversion devices, optical detector, field-effect transistors, electromechanical resonators, and chemical & biological sensors. In particular, the graphene- and RGO-FETs devices are very promising for sensing applications because of advantages including large detection area, low noise level in solution, ease of fabrication, and the high sensitivity to ions and biomolecules comparable to 1D nano-FETs. Even though a limited number of biosensor applications including chemical vapor deposition (CVD) grown graphene film for DNA detection, single-layer graphene for protein detection and single-layer graphene or solution-processed RGO film for cell monitoring have been reported, development of facile fabrication methods and full understanding of sensing mechanism are still lacking. Furthermore, there have been no reports on demonstration of ultrasensitive electrical detection of a cancer biomarker using the graphene- or RGO-FET. Here we describe scalable and facile fabrication of reduced graphene oxide FET (RGO-FET) with the capability of label-free, ultrasensitive electrical detection of a cancer biomarker, prostate specific antigen/${\alpha}$ 1-antichymotrypsin (PSA-ACT) complex, in which the ultrathin RGO channel was formed by a uniform self-assembly of two-dimensional RGO nanosheets, and also we will discuss about the immunosensing mechanism.

  • PDF

산화아연과 탄소나노튜브의 선형 층상 복합체의 일산화질소 가스 감지특성 (NO Gas Sensing Characteristics of Wire-Like Layered Composites Between Zinc Oxide and Carbon Nanotube)

  • 김옥길;김효진;김도진
    • 한국재료학회지
    • /
    • 제22권5호
    • /
    • pp.237-242
    • /
    • 2012
  • We report on the NO gas sensing properties of Al-doped zinc oxide-carbon nanotube (ZnO-CNT) wire-like layered composites fabricated by coaxially coating Al-doped ZnO thin films on randomly oriented single-walled carbon nanotubes. We were able to wrap thin ZnO layers around the CNTs using the pulsed laser deposition method, forming wire-like nanostructures of ZnO-CNT. Microstructural observations revealed an ultrathin wire-like structure with a diameter of several tens of nm. Gas sensors based on ZnO-CNT wire-like layered composites were found to exhibit a novel sensing capability that originated from the genuine characteristics of the composites. Specifically, it was observed by measured gas sensing characteristics that the gas sensors based on ZnO-CNT layered composites showed a very high sensitivity of above 1,500% for NO gas in dry air at an optimal operating temperature of $200^{\circ}C$; the sensors also showed a low NO gas detection limit at a sub-ppm level in dry air. The enhanced gas sensing properties of the ZnO-CNT wire-like layered composites are ascribed to a catalytic effect of Al elements on the surface reaction and an increase in the effective surface reaction area of the active ZnO layer due to the coating of CNT templates with a higher surface-to-volume ratio structure. These results suggest that ZnO-CNT composites made of ultrathin Al-doped ZnO layers uniformly coated around carbon nanotubes can be promising materials for use in practical high-performance NO gas sensors.

$LaCoO_3$ 후막의 가스 감지 특성 (Gas sensing characteristics of $LaCoO_3$ thick-films)

  • 신정호;장재영;마대영;박기철;김정규
    • 센서학회지
    • /
    • 제8권6호
    • /
    • pp.454-460
    • /
    • 1999
  • 스크린 프린팅 법으로 알루미나 기판 위에 $LaCoO_3$ 후막을 형성하여 열처리 온도에 따른 $C_4H_{10}$, $NH_3$, $NO$ 및 CO 가스에 대한 감도를 조사하였다. X-선 분석과 SEM 사진을 통해 $LaCoO_3$ 후막의 구조적 특성을 관찰하였다. 제조한 센서는 $C_4H_{10}$, $NH_3$ NO 가스에 대한 감도보다 CO 가스에 대한 감도가 우수하였다. 후막의 최적 열처리온도와 동작온도는 각각 $800^{\circ}C$$150^{\circ}C$였다. CO 가스 500ppm과 1250ppm에 대한 감도는 각각 72%와 95%였다.

  • PDF

안정화된 광섬유 브래그 격자 센서 시스템을 이용한 실시간 충격위치검출에 관한 연구 (Real-time impact location monitoring using the stabilized Bragg grating sensor system)

  • 방형준;홍창선;김천곤
    • 한국항공우주학회지
    • /
    • 제32권7호
    • /
    • pp.37-42
    • /
    • 2004
  • 본 논문에서는 실시간 충격위치 검출이 가능한 FBG 센서 시스템의 개발에 관하여 설명하였다. 충격위치 검출을 위해서는 동시 다정 신호취득이 가능한 초음파 센서 시스템이 요구된다. 본 연구에서는 23.80nm의 투과파장 간격을 갖는 가변 패브리-페로 복조화 장치를 사용하여 파장분할 다중화가 가능한 FBG 고주파 진동 센서시스템에 적용하였다. 또한 외부의 준정적 환경변화에 대해 FBG 센서의 민감도를 일정하게 유지시키기 위한 민감도 안정화 장치를 사용하였다. 저속충격 실험을 위한 알루미늄보 시편의 아랫면에는 두개의 FBG 센서를 부착하였으며 시편 표면의 세 지점에 대해 1 차원 충격위치 검출을 시도하였다. 실험결과 FBG 센서를 이용하여 저속충격 시점을 정확히 감지할 수 있었으며, 평균 오차 0.58mm 로 충격위치를 검출할 수 있음을 확인하였다.

Design and Vibration Analysis of Tri-axis Linear Vibratory MEMS Gyroscope

  • Seok, Seyeong;Moon, Sanghee;Kim, Kanghyun;Kim, Suhyeon;Yang, Seongjin;Lim, Geunbae
    • 센서학회지
    • /
    • 제26권4호
    • /
    • pp.235-238
    • /
    • 2017
  • In this study, the design of a tri-axis micromachined gyroscope is proposed and the vibration characteristic of the structure is analyzed. Tri-axis vibratory gyroscopes that utilize Coriolis effect are the most commonly used micromachined inertial sensors because of their advantages, such as low cost, small packaging size, and low power consumption. The proposed design is a single structure with four proof masses, which are coupled to their adjacent ones. The coupling springs of the proof masses orthogonally transfer the driving vibrational motion. The resonant frequencies of the gyroscope are analyzed by finite element method (FEM) simulation. The suspension beam spring design of proof masses limits the resonance frequencies of four modes, viz., drive mode, pitch, roll and yaw sensing mode in the range of 110 Hz near 21 kHz, 21173 Hz, 21239 Hz, 21244 Hz, and 21280 Hz, respectively. The unwanted modes are separated from the drive and sense modes by more than 700 Hz. Thereafter the drive and the sense mode vibrations are calculated and simulated to confirm the driving feasibility and estimate the sensitivity of the gyroscope. The cross-axis sensitivities caused by driving motion are 1.5 deg/s for both x- and y-axis, and 0.2 deg/s for z-axis.