Performance Analysis of Sensor Systems for Space Situational Awareness

  • Choi, Eun-Jung;Cho, Sungki;Jo, Jung Hyun;Park, Jang-Hyun;Chung, Taejin;Park, Jaewoo;Jeon, Hocheol;Yun, Ami;Lee, Yonghui
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.303-314
    • /
    • 2017
  • With increased human activity in space, the risk of re-entry and collision between space objects is constantly increasing. Hence, the need for space situational awareness (SSA) programs has been acknowledged by many experienced space agencies. Optical and radar sensors, which enable the surveillance and tracking of space objects, are the most important technical components of SSA systems. In particular, combinations of radar systems and optical sensor networks play an outstanding role in SSA programs. At present, Korea operates the optical wide field patrol network (OWL-Net), the only optical system for tracking space objects. However, due to their dependence on weather conditions and observation time, it is not reasonable to use optical systems alone for SSA initiatives, as they have limited operational availability. Therefore, the strategies for developing radar systems should be considered for an efficient SSA system using currently available technology. The purpose of this paper is to analyze the performance of a radar system in detecting and tracking space objects. With the radar system investigated, the minimum sensitivity is defined as detection of a $1-m^2$ radar cross section (RCS) at an altitude of 2,000 km, with operating frequencies in the L, S, C, X or Ku-band. The results of power budget analysis showed that the maximum detection range of 2,000 km, which includes the low earth orbit (LEO) environment, can be achieved with a transmission power of 900 kW, transmit and receive antenna gains of 40 dB and 43 dB, respectively, a pulse width of 2 ms, and a signal processing gain of 13.3 dB, at a frequency of 1.3 GHz. We defined the key parameters of the radar following a performance analysis of the system. This research can thus provide guidelines for the conceptual design of radar systems for national SSA initiatives.

Detection of Repetition Motion Using Neural network (신경망을 이용한 반복운동 검출)

  • Yoo, Byeong-hyeon;Heo, Gyeong-yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1725-1730
    • /
    • 2017
  • The acceleration sensor and the gyroscopic sensor are used as representative sensors to detect repetitive motion and have been used to analyze various sporting components. However, both sensors have problems with noise sensitivity and accumulation of errors. There have been attempts to use two sensors together to overcome hardware problems. The complementary filter has shown successful results in mitigating the problems of both sensors by minimizing the disadvantages of accelerometer and gyroscope sensors and maximizing their advantages. In this paper, we proposed a modified method using neural network to reduce variable. The neural network is an algorithm that can precisely measure even in unexpected environments or situations by pre-learning the number of various cases. The proposed method applies a Neural Network by dividing the repetitive motion into three sections, the first, the middle and the end. As a result, the recognition rate is 96.35%, 98.77%, 96.92% and the accuracy is 97.18%.

The Improvement of Sensitivity Characteristics of Pd doped $SnO_2$ Nanowire Gas Sensor (Pd 도핑에 따른 $SnO_2$ 나노선 가스센서의 감도 특성 개선)

  • Kim, Yeon-Woo;Kwon, Sun-Il;Park, Seung-Beom;Lee, Seok-Jin;Jung, Tae-Hwan;Yang, Kea-Joon;Lim, Dong-Gun;Park, Jae-Hwan;Kim, Hong-Oh
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.160-161
    • /
    • 2008
  • $SnO_2$는 n형 반도체로써 3.6 eV의 큰 밴드갭을 가지는 물질로 CO와 NOx 가스에 좋은 감도를 나타내는 것으로 보고되고 있다. 문헌에 따른 일반적인 $SnO_2$ 가스센서는 후막이나 벌크형태로 제작되었다. 근래에는 가스감응체가 $SnO_2$ 나노선 형태인 가스센서가 활발한 연구 중에 있다. 본 논문에서는 기판 위에 서로 분리된 전극 패턴에 Au를 촉매로 하여 네트워크 구조로 된 $SnO_2$ 나노선이 합성되었다. 제작된 가스센서에 Pd 도핑에 따른 영향을 알아보기 위하여 1.8 mM의 Pd 용액 ($PdCl_2{\cdot}xH_2O$ 3 mg + $H_2O$ 10 ml)을 이용하여 센서에 도핑하였다. 측정 시스템에서 $NO_2$ 가스에 대한 센서의 특성을 분석한 결과 도핑하지 않은 $SnO_2$ 센서보다 20%정도의 감도가 개선되었다.

  • PDF

Highly Sensitive Gas Sensors Based on Electrospun Indium Oxide Nanofibers for Indoor Toxic CO and HCHO Gases (전기방사법으로 제작한 In2O3 나노섬유 기반 고감도 실내독성 CO 및 HCHO 가스센서)

  • Im, Dong-Ha;Hwang, Sung-Hwan;Kwon, Se-Hun;Jung, Hyunsung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.12
    • /
    • pp.803-808
    • /
    • 2016
  • In this work, one dimension $In_2O_3$ nanostructures as detecting materials for indoor toxic gases were synthesized by an electrospinning process. The morphology of electrospun $In_2O_3$ nanofibers was controlled by electrolyte composition, applied voltage and working distance between a nozzle and a substrate. The synthesized $In_2O_3$ nanofibers-based paste with/without carbon black additives was prepared for the integration on a sensor device. The integration of $In_2O_3$ sensing materials was conducted by a hand-printing of the paste into the interdigit Au electrodes patterned on Si wafer. Gas sensing properties on CO and HCHO gases were characterized at $300^{\circ}C$. The evaluated sensing properties such as sensitivity, response time and recovery time were improved in $In_2O_3$ nanofiber pastes with carbon black, compared to the paste without carbon black.

Technology of Sensors with Human Sensitivity (인간과 같은 감도를 가진 오감센서 기술)

  • Song, Byung-Taeck
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.6
    • /
    • pp.507-514
    • /
    • 2015
  • The Internet of Things era is approaching where all the things are equipped with smart sensors and communicate through internet. The three core technologies of the Internet of Things are 'detection technology' to get information from things and the environment, 'wired and wireless communications and network infrastructure skills' that support to connect things to the internet, and 'service interface technology' that processes the information appropriate to various services. Smart sensor application can expand to smartphone, smart cars, smart home systems, wearable electronic devices, telemedicine systems, and environmental monitoring systems, etc. In particular, technologies that mimic the five human senses. This study reviews the biological principles of the human senses and the principles of operation, research & development status, technology trends and market analysis of the sensors.

Study of Enzyme Immobilization on Composite of CTA and PCL Membrane for Biosensor (바이오센서용 CTA와 PCL 혼합막에의 효소고정화 기법의 개발)

  • 홍성현;김태진
    • KSBB Journal
    • /
    • v.10 no.4
    • /
    • pp.468-474
    • /
    • 1995
  • The disposable glucose bio-sensor using composite of CTA and PCL membrane was developed for measurement of glucose. The most effective membrane was composed of CTA/PCL(80/20, w/w) and glutaraldehyde one-step immobilization method ($10{\mu}m$ thickness) for glucose sensor gave the best result among various methods, considering oxygen permeability and electronic sensitivity. A scanning electron micrograph of the cross-section of a typical asymmetric CTA/PCL composite membrane showed that the membrane fused with a dense layer covered with a GOD-glutaraldehyde. Glucose oxidase immoblilized on the membrane showed the linearity between difference of absolute amperometric values and glucose concentrations within 7mM when the GOD immobilized electrode was used. About 35% of activity was remained after 8 days when the tyrosinase was immobilized on CTA/PCL (80/20) membrane.

  • PDF

Piezo-activated guided wave propagation and interaction with damage in tubular structures

  • Lu, Ye;Ye, Lin;Wang, Dong;Zhou, Limin;Cheng, Li
    • Smart Structures and Systems
    • /
    • v.6 no.7
    • /
    • pp.835-849
    • /
    • 2010
  • This study investigated propagation characteristics of piezo-activated guided waves in an aluminium rectangular-section tube for the purpose of damage identification. Changes in propagating velocity and amplitude of the first wave packet in acquired signals were observed in the frequency range from 50 to 250 kHz. The difference in guided wave propagation between rectangular- and circular-section tubes was examined using finite element simulation, demonstrating a great challenge in interpretation of guided wave signals in rectangular-section tubes. An active sensor network, consisting of nine PZT elements bonded on different surfaces of the tube, was configured to collect the wave signals scattered from through-thickness holes of different diameters. It was found that guided waves were capable of propagating across the sharp tube curvatures while retaining sensitivity to damage, even that not located on the surfaces where actuators/sensors were attached. Signal correlation between the intact and damaged structures was evaluated with the assistance of a concept of digital damage fingerprints (DDFs). The probability of the presence of damage on the unfolded tube surface was thus obtained, by which means the position of damage was identified with good accuracy.

The Study of Fatigue Lifetime Evaluation on the Interconnect of semiconductor sensor according to the various materials (재료에 따른 반도체 센서 배선의 피로 수명 평가에 관한 연구)

  • Shim Jae-Joon;Ran Dong-seop;Ran Geun-Jo;Kim Tae-Hyung
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.283-288
    • /
    • 2005
  • Application of semiconductor sensors has widely spreaded into various industries because those have several merits like easy miniaturization and batch production comparison with previous mechanical sensors. But external conditions such as thermal and repetitive load have a bad effect on sensors's lifetime. Especially, this paper was focused on fatigue life of a interconnect made by various materials. Firstly we implemented the stress analysis for interconnect under thermal load and wording pressure. And the fatigue lifetime of each material was induced by Manson & Coffin Equation using the plastic stress-strain curve obtained by the plastic-elastic Finite Element Analysis.

  • PDF

A Study on Neuroactive Response Sensing Platform after Injection of Muscular Relaxants (근 이완제 투여에 따른 신경 자극 반응 감지 플랫폼에 관한 연구)

  • Kim, Woo-Ram;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.331-334
    • /
    • 2011
  • This is a study about a platform realization measuring the extent of reaction in nerve, as giving a electrical impulse on a nerve pulp regulating a function of muscle, about a measurement of nerve reaction in the amount of current, the lasting time of current, and the position of electrode from a electrical impuls.The position of an electrode in a electrical nerve impuls have nothing to do with all nerves from exercise to all things. There is the Single Twitch Stimulation(STS), Train-of-four(TOF), and Double Burst Stimulation(DBS) in the form of nerve stimulation. This report is needed for selecting MCU of low electric power for a base in embedded system and measuring the extent of reaction after making a sensor interface to know sensitivity of measuring sensor in basic reaction of nerve impuls. The platform is realized to select a high efficiency AD Convertor for raising accuracy in measured data. As the platform in this report was developed for a medical appliances, it was designed to consider user safety in electric power Isolation when making electric power circuit.

  • PDF

A Study on Characteristics of A Diode Radiation Sensor for Portal Image of Therapy Radiation (치료방사선 Portal Image를 위한 다이오드 방사선 센서의 특성에 관한 연구)

  • Lee, Dong-Hun;Kwon, Jang-Woo;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.11-20
    • /
    • 1996
  • In this paper, the characteristics of therapy radiation diode sensors have been studied by using therapy radiation from the MM22 microtron accelerator. The linearity, reproducibility and error ratio were measured for feasibility as a radiation detector. Energy dependence, sensitivity change after a amount of irradiation and output value according to a number of diodes were also measured for same purpose. We have formed pulse shaping of diode signal with nuclear instruments for portal image reconstruction. The percent depth dose ratio according to field size and depth was compared with that of the detector of a ion chamber. Using thirteen silicon diodes, we can directly read diode outputs on a computer monitor after A/D conversion with 16 channels analog to digital conversion board with 12 bit resolution. The possibility for portal image with diodes has been suggested from output comparison between output value with a human phantom and that without a human phantom.

  • PDF