• 제목/요약/키워드: Sensor Corrosion

검색결과 130건 처리시간 0.026초

다중벽 탄소나노튜브를 이용한 철근 부식 검출 센서 제작 연구 (A study on the Corrosion Detection Sensor using Multi-Wall Carbon Nanotube)

  • 박수빈;김성연;이수정;최문정;홍영준;권성준;유봉영;윤상화
    • 한국표면공학회지
    • /
    • 제54권4호
    • /
    • pp.194-199
    • /
    • 2021
  • In this study, rebar corrosion detection sensor was fabricated using multi-walled carbon nanotubes (MWCNTs). MWCNTs were pre-treated in the acid electrolytes to attach the carboxylic acid to the surface of MWCNTs. The fabricated sensor was attached on the surface of rebar and it detected the corrosion of steel using LCR meter with variation of capacitance. The surface morphology and electrical properties were characterized using scanning electron microscope (SEM) and electrical test equipment, respectively. To verify the corrosion detection characteristics, comparison experiment using plastic bar was performed. Moreover, mechanism of corrosion detection sensor was discussed.

전기저항형 센서 및 전기화학적 방법을 이용한 철근콘크리트 구조물의 부식속도 측정 방법에 관한 연구 (Study on The Corrosion Rate Monitoring of Steel in Concrete Using Electric resistance Sensor and Electrochemical Methods.)

  • 조용범;김용철;장상엽;고영태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1185-1192
    • /
    • 2001
  • This paper reviews available techniques for monitoring corrosion of steel in concrete. The need for early detection and diagnosis of corrosion related deterioration in reinforced structures is widely acknowledged. This is particularly important in reinforced concrete structures on account of the economic and social significance of the problem. The current generally used on-site procedure for corrosion monitoring of reinforced structures employs a method of half-cell surface potential measurements. While the technique has provided a useful means of delineating areas of high or low corrosion risk, there are difficulties in its use and interpretation when assessing rates of deterioration. Electrochemical techniques are by far the most suitable for corrosion monitoring purpose and meet most of the requirements. The aim of this paper is to describe the electric resistance sensor(ER sensor) and electrochemical techniques employed to monitor and estimate corrosion rates of reinforcement. Early detection and diagnosis of corrosion hazards allows preventive measures to be taken, hence the typically expensive repair of severely deteriorated structures can be avoided.

  • PDF

RC 구조물의 Eddy Current 기반 철근부식 감지 센서에 관한 실험적 연구 (Experimental Study on Eddy Current based-on Corrosion Detection Sensor for RC structure)

  • 양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.260-261
    • /
    • 2019
  • Corrosion of rebar embedded reinforced concrete is the main cause of collapse and degradation of reinforced concrete structure that many researches are recently focused on these works. Methods of evaluating rebar corrosion are divided into physical and electrochemical methods. However, the result of Conventional methods are less reliable due to effect of internal and external environments. In this study, rebar corrosion detection sensor for embedded rebar of RC structures is evaluated through immersion test in NaCl solustion for 160hours. From the results, Rebar corrosion was ongoing and corrosion products are produced on rebar surface. The voltage is decreased as amount of corrosion production increased.

  • PDF

비파괴 철근 부식 진단을 위한 매립형 미니센서 개발에 관한 기초적 연구 (Fundamental Study on Developing Embedded Mini-Sensor for Nondestructive Diagnosis Corrosion of Rebar)

  • 조성형;임영철;;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권6호
    • /
    • pp.179-187
    • /
    • 2010
  • 콘크리트 내부에 매설된 철근의 부식은 철근콘크리트구조물의 조기 성능저하와 붕괴의 주요원인이 되고 있다. 철근콘크리트 구조물에 발생하는 열화현상 중에서 철근부식에 의해 발생되는 염해는 그 피해가 다른 열화 현상보다 심하고 구조물의 보수 및 시공 측면에서도 막대한 경비가 요구되고 보수시기 또한 정하기 힘들다. 따라서 철근의 부식상태에 대한 조기발견은 관리자의 효율적인 보수 및 보강계획 수립을 위해 매우 중요하다. 한편 철근 부식을 평가하는 방법 중 비파괴측정이 많이 사용되고 있다. 특히 CM-II(corrosion meter) 측정기는 자연전위와 분극저항 및 콘크리트 비저항을 측정할 수 있어서 많이 사용되지만 몇 가지 단점을 가지고 있다. 이러한 단점을 극복하기 위해 매립형 미니센서가 개발되어져 왔다. 이 미니센서를 이용하여 철근 부식을 측정한 후 CM-II(corrosion meter)의 측정결과와 비교분석하여 개발된 미니센서의 타당성을 검증하였다.

항만센서용 수정진동자의 해수에 의한 부식 (Corrosion of Quartz Crystal Marine Sensors in Sea Water)

  • 최광재;장상목;김영한
    • 한국항만학회지
    • /
    • 제12권2호
    • /
    • pp.323-328
    • /
    • 1998
  • A quartz crystal analyzer is utilized to monitor the corrosion process of an aluminum surface of a quartz crystal for marine sensor by sea water. A quartz crystal having 2000 $\AA$ of aluminum layer is installed in a specially designed cell and is in contact with sea water imitated electrolyte solution. While a constant potential is applied to the cell, the resonant frequency and resonant resistance are simultaneously measured using the quartz crystal analyzer. In addition, surface topographs are taken with an atomic force microscope(AFM) and the element analysis of the surface is conducted using an energy dispersive X-ray spectrometer(EDX). The simultaneous measurement of resonant frequency and resonant resistance during the corrosion process explains the change of surface structure caused by the corrosion. The variation of resonant frequency addresses the amount surface metal dissolution. As a conclusion, it is found that a simple measurement using the quartz crystal analyzer can replace the complex monitoring employing large equipments in the investigation of a corrosion process of sensor surface.

  • PDF

Exploratory research on ultra-long polymer optical fiber-based corrosion sensing for buried metal pipelines

  • Luo, Dong;Li, Yuanyuan;Yang, Hangzhou;Sun, Hao;Chen, Hongbin
    • Smart Structures and Systems
    • /
    • 제26권4호
    • /
    • pp.507-520
    • /
    • 2020
  • In order to achieve effective corrosion monitoring of buried metal pipelines, a Novel nondestructive Testing (NDT) methodology using ultra-long (250 mm) Polymer Optical Fiber (POF) sensors coated with the Fe-C alloy film is proposed in this study. The theoretical principle is investigated to clarify the monitoring mechanism of this method, and the detailed fabrication process of this novel POF sensor is presented. To validate the feasibility of this novel POF sensor, exploratory research of the proposed method was performed using simulated corrosion tests. For simplicity, the geometric shape of the buried pipeline was simulated as a round hot-rolled plain steel bar. A thin nickel layer was applied as the inner plated layer, and the Fe-C alloy film was coated using an electroless plating technique to precisely control the thickness of the alloy film. In the end, systematic sensitivity analysis on corrosion severity was further performed with experimental studies on three sensors fabricated with different metal layer thicknesses of 25 ㎛, 30 ㎛ and 35 ㎛. The experimental observation demonstrated that the sensor coated with 25 ㎛ Fe-C alloy film presented the highest effectiveness with the corrosion sensitivity of 0.3364 mV/g at Δm = 9.32 × 10-4 g in Stage I and 0.0121 mV/g in Stage III. The research findings indicate that the detection accuracy of the novel POF sensor proposed in this study is satisfying. Moreover, the simple fabrication of the high-sensitivity sensor makes it cost-effective and suitable for the on-site corrosion monitoring of buried metal pipelines.

부식센서를 이용한 콘크리트 철근부식 모니터링 기술 개발 연구 (On the Development of Monitoring Technique for Rebar Corrosion in Concrete using Sensor)

  • 김용철;장상엽;조용범;이한승;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.163-168
    • /
    • 2003
  • By introducing corrosion monitoring techniques, steel corrosion in concrete may be evaluated at early stage. The monitoring probes in concrete detect the causes (chlorides and $CO_2$) of steel corrosion by being cast into the concrete or diffusing in from the outside. Various systems for corrosion monitoring in concrete are reviewed in this paper. These techniques are classified according to monitoring purposes such as corrosion potential or corrosion rate of steel and causes for corrosion etc.. Today, special interests are converged in development of corrosion sensor as a monitoring method of new concept.

  • PDF

착탈형 구조를 갖는 와류센서를 이용한 ACSR전선 부식검출기 개발 (The development of the ACSR corrosion detector using eddy current sensor with removable type)

  • 강지원;조성배;정재기;양병모;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2371-2373
    • /
    • 1999
  • This paper deals with the development, reliability, specification and performances of the ACSR inner corrosion detector system. It is designed to run on ACSR automatically and to inspect the corrosion of the line with on-line continuously. And it comprises a sensor a constant current source, a signal processing unit, a RF transmitter and receiver unit. Also separable encircling coil sensor is proposed in order to detect inner corrosion of the overhead ground wires. In conclusion, this detector can realize the nondestructive detecting of an ACSR inner corrosion.

  • PDF

Three-poles Touch-type Corrosion Sensor for Edge Detection of Initial State of Iron Rust

  • Yonemoto, Naruto;Shida, Katsunori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.308-311
    • /
    • 1998
  • Some nondestructive diagnostic methods including various types of corrosion sensors have been investigated. Under these conditions, a new structure of sensor that has a pair of electrode and magneto-supply was proposed. In order to detect the edge of the iron rust part, three-poles touch-type corrosion sensor is now proposed. The iron rust pattern where the sensor touches is estimated by means of the impedance of the sensor, and the edge of the iron rust is recognized by comparing the three measured impedances. As the result, our proposed sensor is useful to detect the initial state of iron rust.

  • PDF

해양콘크리트 구조물의 철근부식 모니터링을 위한 부식센서 고찰 (Case study of Corrosion Monitoring Sensor for Marine HC Structure)

  • 장봉석;차흥윤;안정환;김보성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.263-264
    • /
    • 2009
  • 본 연구는 해양환경에 노출된 매스콘크리트 구조물의 설계내구수명을 검증하고, 열화속도가 예상보다 빠른 경우 사용수명 100년 확보를 위한 유지관리 대책을 적기에 수립하기 위한 철근부식 모니터링 센서와 관련하여 현장 적용사례를 소개하고자 한다.

  • PDF