• 제목/요약/키워드: Sensitivity Margin

검색결과 134건 처리시간 0.028초

모델 불확실성을 고려한 변형된 IMC-PID 제어기 설계 (A Modified IMC-PID Controller Design Considering Model Uncertainty)

  • 김창현;임동균;서병설
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.128-130
    • /
    • 2005
  • This paper proposes a modified IMC-PID controller that introduces controlling factor of the system identification to the standard IMC-PID controller in order to meet the design specifications such as gain, phase margin and maximum magnitude of sensitivity function in the frequency domain as well as the design specifications in time domain, settling, rising time and overshoot, and so on.

  • PDF

Optimal Placement for FACTS to Improve Static Voltage Stability

  • Gu, Min-Yan;Baek, Young-Sik
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.141-145
    • /
    • 2004
  • FACTS devices, such as the Thyristor Controlled Series Compensator (TCSC) and Static Var Compensators (SVC), can help increase system load margin to improve static voltage stability. In power systems, because of the high cost and the effect value, the optimal placement for FACTS devices must be determined. This paper investigates the use of the series device (SVC) and the parallel device (TCSC) from the point of load margin to increase voltage stability. It considers the sensitivity of load margin to the line reactance and eigenvector of the collapse. The study has been carried out on the IEEE 14 Bus Test System to verify the validity and efficiency of the method. It reveals that incorporation of FACTS devices significantly enhance load margin as well as system stability.

Sensitivity Studies on Thermal Margin of Reactor Vessel Lower Head During a Core Melt Accident

  • Kim, Chan-Soo;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.379-394
    • /
    • 2000
  • As an in-vessel retention (IVR) design concept in coping with a severe accident in the nuclear power plant during which time a considerable amount of core material may melt, external cooling of the reactor vessel has been suggested to protect the lower head from overheating due to relocated material from the core. The efficiency of the ex-vessel management may be estimated by the thermal margin defined as the ratio of the critical heat flux (CHF)to the actual heat flux from the reactor vessel. Principal factors affecting the thermal margin calculation are the amount of heat to be transferred downward from the molten pool, variation of heat flux with the angular position, and the amount of removable heat by external cooling In this paper a thorough literature survey is made and relevant models and correlations are critically reviewed and applied in terms of their capabilities and uncertainties in estimating the thermal margin to potential failure of the vessel on account of the CHF Results of the thermal margin calculation are statistically treated and the associated uncertainties are quantitatively evaluated to shed light on the issues requiring further attention and study in the near term. Our results indicated a higher thermal margin at the bottom than at the top of the vessel accounting for the natural convection within the hemispherical molten debris pool in the lower plenum. The information obtained from this study will serve as the backbone in identifying the maximum heat removal capability and limitations of the IVR technology called the Cerium Attack Syndrome Immunization Structures (COASISO) being developed for next generation reactors.

  • PDF

멀티밴드 UWB 시스템의 무선성능 분석에 관한 연구 (A Study on the RF performance analysis for Multi-band Ultra Wide Band Systems)

  • 최석;김길겸;곽준호;김학선
    • 한국통신학회논문지
    • /
    • 제28권12A호
    • /
    • pp.951-957
    • /
    • 2003
  • 통신 시스템의 무선성능 요구조건 분석은 시스템의 성능을 예측하는 중요한 지표이다. 아직 표준안이 제정되지 않은 UWB(Ultra Wide Band) 시스템은 명확한 시스템 성능 요구조건을 유도하기 어렵다. 또한, 기존의 UWB 시스템과 멀티밴드 UWB 시스템의 무선성능 요구조건 분석에는 차이점이 있다. 이러한 차이점을 본 논문을 통해 분석하였으며, 이를 바탕으로 도출한 멀티밴드 UWB 시스템의 성능 요구조건을 본 논문에 기술하였다. 멀티밴드 UWB 시스템은 Sub-Band의 수에 따라 Throughput, 송신 최대 전력, 수신감도 등이 변화하는 것을 관찰할 수 있었다. 또한, 멀티패스의 영향으로 PRF(Pulse Repetition Frequency)를 변경하면 Link Margin은 증가하여 멀티패스 에너지 손실(Multi-path Energy Loss)에 대한 보상으로 멀티패스 마진(Multi-path Link Margin)이 발생하는 것을 알 수 있었으며 멀티패스 마진에 따라 수신신호 감도 및 간섭신호에 대한 저항성이 변화하는 것을 모의실험을 통하여 분석하였다.

SENSITIVITY ANALYSES OF THE USE OF DIFFERENT NEUTRON ABSORBERS ON THE MAIN SAFETY CORE PARAMETERS IN MTR TYPE RESEARCH REACTOR

  • Kamyab, Raheleh
    • Nuclear Engineering and Technology
    • /
    • 제46권4호
    • /
    • pp.513-520
    • /
    • 2014
  • In this paper, three types of operational and industrial absorbers used at research reactors, including Ag-In-Cd alloy, $B_4C$, and Hf are selected for sensitivity analyses. Their integral effects on the main neutronic core parameters important to safety issues are investigated. These parameters are core excess reactivity, shutdown margin, total reactivity worth of control rods, thermal neutron flux, power density distribution, and Power Peaking Factor (PPF). The IAEA 10 MW benchmark core is selected as the case study to verify calculations. A two-dimensional, three-group diffusion model is selected for core calculations. The well-known WIMS-D4 and CITATION reactor codes are used to carry out these calculations. It is found that the largest shutdown margin is gained using the $B_4C$; also the lowest PPF is gained using the Ag-In-Cd alloy. The maximum point power densities belong to the inside fuel regions surrounding the central flux trap (irradiation position), surrounded by control fuel elements, and the peripheral fuel elements beside the graphite reflectors. The greatest and least fluctuation of the point power densities are gained by using $B_4C$ and Ag-In-Cd alloy, respectively.

전력시스템 안전도 향상을 위한 다기 UPFC의 최적 운전점 결정 (The Optimal Operating Points of Multiple UPFCs for Enhancing Power System Security Level)

  • 임정욱;문승일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권8호
    • /
    • pp.388-394
    • /
    • 2001
  • This paper presents how to determine the optimal operating points of Unified Power Flow controllers (UPFC) the line flow control of which can enhance system security level. In order to analyze the effect of these devices on the power system, the decoupled model has been employed as a mathematical model of UPFC for power flow analysis. The security index that indicates the level of congestion of transmission line has been proposed and minimized by iterative method. The sensitivity of objective function for control variables of and UPFC has been derived, and it represents the change in the security index for a given set of changes in real power outputs of UPFC. The proposed algorithm with sensitivity analysis gives the optimal set of operating points of multiple UPECs that reduces the index or increases the security margin and Marquart method has been adopted as an optimization method because of stable convergence. The algorithm is verified by the 10-unit 39-bus New England system that includes multiple FACTS devices. The simulation results show that the power flow congestion can be relieved in normal state and the security margin can be guaranteed even in a fault condition by the cooperative operation of multiple UPECs.

  • PDF

Back-gate bias를 이용한 SOI nano-wire BioFET의 electrical sensing (Electrical sensing of SOI nano-wire BioFET by using back-gate bias)

  • 정명호;안창근;조원주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.354-355
    • /
    • 2008
  • The sensitivity and sensing margin of SOI(silicon on insulator) nano-wire BioFET(field effect transistor) were investigated by using back-gate bias. The channel conductance modulation was affected by doping concentration, channel length and channel width. In order to obtain high sensitivity and large sensing margin, low doping concentration, long channel and narrow width are required. We confirmed that the electrical sensing by back-gate bias is effective method for evaluation and optimization of bio-sensor.

  • PDF

IMC-PID 제어기의 최적 동조 (An Optimum Tuning for IMC-PID Controller)

  • 박종수;임동균;서병설
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2006년도 춘계학술발표논문집
    • /
    • pp.344-347
    • /
    • 2006
  • This paper proposes an optimum tuning which improves the tuning effect of IMC-PID and guarantees the performance and robustness of controller system by considering gain margin, phase margin, sensitivity functions and integral square error(ISE) for IMC-PID controller.

  • PDF

KEY IMPACT PARAMETERS FOR APPLICATION OF ALTERNATIVE SOURCE TERM TO KORI UNIT 1

  • Lee, Seung-Chan
    • Nuclear Engineering and Technology
    • /
    • 제42권4호
    • /
    • pp.394-413
    • /
    • 2010
  • The object of this paper is to identify the key elements that impact a radiation dose at EAB (Exclusion Area Boundary). This study is based on the AST (Alternative Source Terms) as defined in Regulatory Guide 1.183. The LOCA (Loss of Coolant Accident) and the LRA (Locked Rotor Accident) are selected as limiting cases. A sensitivity analysis of accidental behavior with respect to various parameters during LOCA and LRA at Kori Unit 1 is also undertaken for the following objectives: to determine the limiting parameters, to find the impact trend of the radiation dose, and to find the safety margin between AST and TID (Technical Information Document) methodologies. This work confirms that key parameters are particulate removal rate, decontamination factor, iodine chemical form, gap fraction, partitioning factor, and the impact of isotopes group. Comparing TID with AST, the radiation dose of TID is about 80% greater than that of AST under a LOCA, and about 60% greater than that of AST for the case of a LRA; thus the safety margin is remarkably increased when the AST is used. In this work, the sensitivity analysis results are presented in terms of a sensitivity index called the "NDD (Normalized Dose Difference)", which compares the impact of parameters with that of a reference case. These values are derived by using a combination of the leak rate (primary to secondary), iodine chemical form, gap fraction, partitioning factor, spray removal rate, source term, and other variables.

The Importance of Interface Irregularity between the Tumor and Brain Parenchyma in Differentiating between Typical and Atypical Meningiomas: Correlation with Pathology

  • Lee, Jeongmin;Lee, Yeon Soo;Ahn, Kook-Jin;Lee, Song;Jang, Jinhee;Choi, Hyun Seok;Jung, So-Lyung;Kim, Bum-soo;Jeun, Sinsoo;Hong, Yongkil
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권3호
    • /
    • pp.158-166
    • /
    • 2016
  • Purpose: To understand clinical significance of irregular interface between meningioma and adjacent brain parenchyma in predicting histological grading of tumor, focusing on brain parenchymal invasion. Materials and Methods: Pathologically confirmed 79 cases with meningiomas with pathological reports about the presence of parenchymal invasion were included. We defined the presence of interface irregularity as either spiculations or fuzzy margins between the tumor and brain parenchyma. We counted number of spiculations and measured ratio of fuzzy margin length to whole length of mass with consensus of two neuroradiologists. We classified the patients into Present group and Absent group, and the two groups were compared by using the Mann-Whitney U test. Statistical correlations between the presence of an interface irregularity and brain parenchymal invasion by the tumor as well as meningioma histological grade were tested with chi-square test. The optimal cutoff values of spiculation numbers and the ratio of fuzzy margins were determined. The sensitivity and specificity of number of spiculations, ratio of fuzzy margin and the presence of irregular interface as combined parameters for predicting the parenchymal invasion were calculated using ROC curve analysis. Results: Statistically significant differences were noted between the Present and Absent groups for number of spiculations and ratio of fuzzy margin (P = 0.038 and P = 0.028, respectively). The optimal cutoff value for number of spiculations (> 4.5 with 61.1% sensitivity and 68.9% specificity) and the ratio of fuzzy margin (> 0.24 with 66.7% sensitivity and 65.6% specificity) were determined. The sensitivity and specificity of interface irregularity as the combined parameters were 72% and 59%, respectively. The interface irregularity between tumor and brain parenchyma significantly correlated with not only brain parenchymal invasion (P = 0.001) and but also histological grade (P < 0.001). Conclusion: The interface irregularity between tumor and brain parenchyma in MRI can be a strong predictive factor for brain parenchymal invasion and high grade meningioma.