• Title/Summary/Keyword: Sensitivity Axis

Search Result 217, Processing Time 0.026 seconds

A Study on Dynamic Characteristics of 3-axis Actuator for the Slim Type Pick-Up (3축 구동이 가능한 Slim형 Pick-Up Actuator 개발 및 동특성 분석)

  • 박관우;서민석;홍삼열;김영중;최인호;김진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.373-377
    • /
    • 2002
  • In this study, we suggested a slim-type actuator that can be controlled in radial direction for compensating coma aberration in high-capacity optical storage devices. To deal successfully with narrow space in slim-type optical pick-up for notebook pc device, additional yokes for tilting motion are integrated into main yoke of the actuator. And the location of tilting coils is determined for mass-b3lancing effect to achieve optimal configuration for high driving sensitivity. We also suggested new concept of lens holder to guarantee excellent stability of control system by enhancing the gain margin at secondary resonant frequency. The concept was realized by forming damping sections in the lens holder, which prevent vibrational energy from transferring to lens. An exclusive measurement system was newly developed for fast and precise measurement of dynamic characteristics of actuators and utilized for the practical use. We hope to make good use of this system also in time to come.

  • PDF

An Experimental Study on the Manoeuvrability of a Ship in Different GM and Trim Conditions (GM 및 종경사 변경에 따른 선박의 조종성능변화에 관한 실험적 연구)

  • Yun, Kunhang;Kim, Dong Jin;Yeo, Dong Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.4
    • /
    • pp.230-240
    • /
    • 2020
  • The aim of this study was to investigate the manoeuvrability of a ship in different Center of Gravity (CG) conditions. Free Running Model Tests (FRMT), such as 35°turning circle tests, 20/20 zigzag manoeuvring tests, and 10/10 zigzag manoeuvring tests, were conducted in three GM and three trim conditions with 1/65.83 scaled KRISO Container Ship (KCS). The test results indicated that KCS in the lower GM condition and the trim by bow condition showed reduced advance and tactical diameter in turning circle tests and increased overshoot angles in zigzag tests, and those manoeuvring indices were strongly related with roll angle. In addition, sensitivity indices for three-axis CG position were suggested with prior research, and it showed that y-axis CG position significantly affected manoeuvrability of KCS due to the low GM. Therefore, in the case of KCS, it is evident that the roll angle during manoeuvre is closely related with manoeuvring indices.

Time Domain of Algorithm for The Detection of Freezing of Gait(FOG) in Patients with Parkinson's Disease (파킨슨병 환자의 보행동결 검출을 위한 시간영역 알고리즘)

  • Park, S.H.;Kwon, Y.R.;Kim, J.W.;Eom, G.M.;Lee, J.H.;Lee, J.W.;Lee, S.M.;Koh, S.B.
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.182-188
    • /
    • 2013
  • This study aims to develop a practical algorithm which can detect freezing of gait(FOG) in patients with Parkinson's disease(PD). Eighteen PD patients($68.8{\pm}11.1yrs.$) participated in this study, and three($68.7{\pm}4.0yrs.$) of them showed FOG. We suggested two time-domain algorithms(with 1-axis or 3-axes acceleration signals) and compared them with the frequency-domain algorithm in the literature. We measured the acceleration of left foot with a 3-axis accelerometer inserted at the insole of a shoe. In the time-domain method, the root-mean-square(RMS) acceleration was calculated in a moving window of 4s and FOG was defined as the periods during which RMS accelerations located within FOG range. The parameters in each algorithm were optimized for each subject using the simulated annealing method. The sensitivity and specificity were same, i.e., $89{\pm}8%$ for the time-domain method with 1-axis acceleration and were $91{\pm}7%$ and $90{\pm}8%$ for the time-domain method with 3-axes acceleration, respectively. Both performances were better in the time-domain methods than in the frequency-domain method although the results were statistically insignificant. The amount of calculation in the time-domain method was much smaller than in the frequency-domain method. Therefore it is expected that the suggested time domain algorithm would be advantageous in the systematic implementation of FOG detection.

The Variation in Chromaticity of Optical System having the Truncated Incident Beam (입사광의 단락된 정도에 따른 광학계의 색도 변화)

  • Park, Seong Jong;Chung, Chang Sub;Sim, Sang Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.13-18
    • /
    • 2000
  • In this paper, we use the C light which is a daylight and consider the incident beam having the Gaussian amplitude. We investigated the illuminance distributions and the variation in chromaticity of optical system having the truncated Gaussian amplitude on the focal plane and along the optical axis using the C light source. We also use the three sensitivity functions of human eye(CIE 1931) for wavelengths which are from 380nm to 780nm. When the truncation grade of incident beam having Gaussian amplitude decreases, the size of central spot on the focal plane and the depth of focus along the optical axis decrease, and the variation in chromaticity on the focal plane and along the axis increases rapidly. As the illuminance on the focal plane decreases the variation in chromaticity of optical system increases rapidly, and as the depth of focus increases the variation in chromaticity of optical system decreases.

  • PDF

Measurement of Wavefront Aberrations in Off-Axis Parabolic Mirrors and its Dependence on the Misalignment (레이저 빔의 파면 측정을 통한 비축 포물 거울의 성능 평가 및 정렬 오차 민감도에 관한 연구)

  • Jeong, Tae-Moon;Choi, Il-Woo;Ko, Do-Kyeong;Lee, Jong-Min
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.256-261
    • /
    • 2006
  • Wavefront aberrations of a laser beam that was reflected from an off-axis parabolic (OAP) mirror were measured to evaluate the optical performance of the OAP mirror. For a diamond turned OAP mirror, the root-mean-square (rms) value of higher-order aberrations was only $0.03{\mu}m$ for the laser beam size of about 34 mm. The other OAP mirror which was polished at a domestic company had the rms value of higher-order aberrations of $2.07{\mu}m$ for the same beam size. Although the diamond turned OAP mirror was well fabricated to have a small amount of aberrations, the aberrations were induced by the misalignment of the OAP mirror. Especially, 0 degree astigmatism increased with the sensitivity of $0.372{\mu}m/mrad$ when the OAP mirror was tilted in the tangential plane, which agreed well with the calculated results using a commercial ray tracing software.

Quantitative Analysis of Thallium-201 Myocardial Tomograms (Thallium-201 심근 단층영상의 정량적 분석)

  • Kim, Sang-Eun;Nam, Gi-Byoung;Choi, Chang-Woon;Choi, Kee-Joon;Lee, Dong-Soo;Sohn, Dae-Won;Ahn, Cu-Rie;Chung, June-Key;Lee, Myoung-Mook;Lee, Myung-Chul;Park, Young-Bae;Choi, Yun-Shik;Seo, Jung-Don
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.165-176
    • /
    • 1991
  • The purpose of this study was to assess the ability of quantitative Tl-201 tomography to identify and localize coronary artery disease (CAD). The study population consisted of 41 patients (31 males, 10 females; mean age $55{\pm}7$ yr) including 14 with prior myocardial infarction who underwent both exercise Tl-201 myocardium SPECT and coronary angiography for the evaluation of chest pain. From the short axis and vertical long axis tomograms, stress extent polar maps were generated by Cedars-Sinai Medical Center program, and the % stress defect extent (SDE) was quantified for each coronary artery territory. For the purpose of this study, the coronary circulation was divided into 6 arterial segments, and the "myocardial ischemic score" (MIS) was calculated from the coronary angiogram. Sensitivity for the detection of CAD ($\geq50%$ coronary stenosis by angiography) by angiography) by stress extent polar map was 95% in single vessel disease, and 100% in double and triple vessel deseases. Overall sensitivity was 97%. Sensitivity and specificity for the detection of individual diseased vessels were, respectively, 87% and 90% for the left anterior descending artery (LAD), 36% and 93% for the left circumflex artery (LCX), and 71% and 70% for the right coronary artery (RCA). Concordance for the detection of individual diseased vessels between the coronary angiography and stress polar map was fair for the LAD (kappa=0.70), and RCA (kappa=0.41) lesions, whereas it was poor for the LCX lesions (kappa : 0.32). There were siginificant correlations between the MIS and SDE in LAD (rs=0.56, p=0.0027), and RCA territory (rs=0.60, p=0.0094). No significant correlation was found in LCX territory. When total vascular territories were combined, there was a significant correlation between the MIS and SDE (rs=0.42, p=0.0116). In conclusion, the quantitative analysis of Tl-201 tomograms appears to be accurate for determining the presence and location of CAD.

  • PDF

Study on Standardization of Korean Version of Psychiatric Diagnostic Screening Questionnaire(K-PDSQ) (한국판 정신장애 진단 선별 질문지의 표준화 연구)

  • Choi, Hyeong-Keun;Jung, Sung-Won;Jo, Hyun-Ju;Kim, Jeong-Bum;Jung, Chul-Ho
    • Anxiety and mood
    • /
    • v.9 no.1
    • /
    • pp.31-37
    • /
    • 2013
  • Objective : The PDSQ is a brief and psychometrically strong self-report scale designed to screen for common DSM-IV Axis I disorders in clinical settings. In this study, the K-PDSQ was compared with the M.I.N.I.-Plus (Mini-International Neuropsychiatric Interview-Plus) for diagnostic validity and availability of the K-PDSQ as a part of standardization of the K-PDSQ. Methods : The 640 patients were evaluated with the K-PDSQ and the M.I.N.I.-Plus. Diagnosing with the M.I.N.I.-Plus, the diagnostic correspondence, administering time, sensitivity, specificity, ROC curve, and AUC of the K-PDSQ were evaluated. Results : For the diagnostic correspondence of the K-PDSQ, Cohen's kappa coefficient was .66 between the K-PDSQ and the M.I.N.I.-Plus. The administering time of the K-PDSQ was $18.2{\pm}11.80$ minutes. Both sensitivity and specificity of the K-PDSQ were higher: the mean sensitivity across 10 subscales of K-PDSQ was 86%; the mean specificity was 84%. All AUCs of each subscale were above .80, which were statistically significant. Conclusion : The K-PDSQ is valid and available as a diagnostic screening tool. It will be widely used in clinical settings for screening DSM-IV Axis I diagnosis because of its simplicity and high reliability.

Wafer Level Vacuum Packaged Out-of-Plane and In-Plane Differential Resonant Silicon Accelerometers for Navigational Applications

  • Kim, Illh-Wan;Seok, Seon-Ho;Kim, Hyeon-Cheol;Kang, Moon-Koo;Chun, Kuk-Jin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.1
    • /
    • pp.58-66
    • /
    • 2005
  • Inertial-grade vertical-type and lateral-type differential resonant accelerometers (DRXLs) are designed, fabricated using one process and tested for navigational applications. The accelerometers consist of an out-of-plane (for z-axis) accelerometer and in-plane (for x, y-axes) accelerometers. The sensing principle of the accelerometer is based on gap-sensitive electrostatic stiffness changing effect. It says that the natural frequency of the accelerometer can be changed according to an electrostatic force on the proof mass of the accelerometer. The out-of-plane resonant accelerometer shows bias stability of $2.5{\mu}g$, sensitivity of 70 Hz/g and bandwidth of 100 Hz at resonant frequency of 12 kHz. The in-plane resonant accelerometer shows bias stability of $5.2{\mu}g$, sensitivity of 128 Hz/g and bandwidth of 110 Hz at resonant frequency of 23.4 kHz. The measured performances of two accelerometers are suitable for an application of inertial navigation.

3-Axial Isotropic Electric-Field Probe Design with Resistor-Loaded Short Dipole (저항 부하된 소형 다이폴을 이용한 3축 등방성 전기장 프로브 설계)

  • Moon, Sung-Won;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.3
    • /
    • pp.246-249
    • /
    • 2017
  • In this paper, we designed the 3-axis isotropic electric-field measurement probe using resistor-loaded short dipole with lumped chip resistors. The designed probe shows good isotropic characteristics as well as wideband and low sensitivity. The isotropic characteristics of ${\pm}0.39dB$ from 100 kHz to the 3 GHz band were derived and the reception sensitivity was 0.1 V/m. The frequency response is within 3 dB of the whole section, especially ${\pm}1.3dB$ from 150 kHz to 3 GHz, which is superior to the conventional electric field probe with short dipoles.

A Study on the Accelerometer for the Acceleration and Inclination Estimation of Structures using Double-FBG Optical Sensors (이중 FBG 광섬유센서를 이용한 구조물 가속도 및 기울기 측정 장치에 관한 연구)

  • Lee, Geum-Suk;Ahn, Soo-Hong;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.1
    • /
    • pp.85-94
    • /
    • 2016
  • In this study, an acceleration sensor that has optical fibers to measure the inclination and acceleration of a structure through contradictory changes in two-component FBG sensors was examined. The proposed method was to ensure precise measurement through the unification of the deformation rate sensor and the angular displacement sensor. A high sensitivity three-axis accelerometer was designed and prepared using this method. To verify the accuracy of the accelerometer, the change in wavelength according to temperature and tension was tested. Then, the change in wavelength of the prepared accelerometer according to the sensor angle, and that of the sensor according to the change in ambient temperature were measured. According to the test results on the FBG-based vibration sensor that was developed using a high-speed vibrator, the range in measurement was 0.7 g or more, wavelength sensitivity, 2150 pm/g or more, and the change in wavelength change, $9.5pm/^{\circ}C$.