• 제목/요약/키워드: Sensitive to radiation

검색결과 386건 처리시간 0.023초

광민감 광섬유와 일반 단일모드 광섬유로 제작한 브래그 격자 센서의 감마방사선 영향 (Gamma-radiation Effects on Fiber Bragg Gratings Written in Photo-sensitive and Commercial Single-mode Optical Fibers)

  • 김종열;이남호;정현규;임돈순
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.701-704
    • /
    • 2014
  • 본 논문에서는 광민감 광섬유와 일반 단일모드 광섬유로 제작된 광섬유 브래그 격자 센서의 감마방사선 영향을 분석하였다. 제작된 광섬유 브래그 격자 센서는 $Co^{60}$ 감마선원을 이용하여 300 Gy/min의 선량률로 총선량 17.8 kGy 감마선을 조사하였다. 실험결과를 통하여 수소로딩을 하지 않은 광민감 광섬유로 제작된 격자 센서가 가장 낮은 18 pm의 브래그 파장 이동을 보였다.

  • PDF

첨단 암 치료로서 중입자치료의 임상적 유용성에 대한 고찰 (Literature Review of Clinical Usefulness of Heavy Ion Particle as an New Advanced Cancer Therapy)

  • 최상규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.413-422
    • /
    • 2019
  • Heavy ion particle, represented carbon ion, radiotherapy is currently most advanced radiation therapy technique. Conventional radiation therapy has made remarkable changes over a relatively short period of time and leading various developments such as intensity modulated radiation therapy, 4D radiation therapy, image guided radiation therapy, and high precisional therapy. However, the biological and physical superiority of particle radiation, represented by Bragg peak, can give the maximum dose to tumor and minimal dose to surrounding normal tissues in the treatment of cancers in various areas surrounded by radiation-sensitive normal tissues. However, despite these advantages, there are some limitations and factors to consider. First, there is not enough evidence, such as large-scale randomized, prospective phase III trials, for the clinical application. Secondly, additional studies are needed to establish a very limited number of treatment facilities, uncertainty about the demand for heavy particle treatment, parallel with convetional radiotherapy or indications. In addition, Bragg peak of the heavy particles can greatly reduce the dose to the normal tissues front and behind the tumor compared to the photon or protons. High precision and accuracy are needed for treatment planning and treatment, especially for lungs or livers with large respiratory movements. Currently, the introduction of the heavy particle therapy device is in progress, and therefore, it is expected that more research will be active.

위암환자의 수술중 전자선을 이용한 방사선 치료방법에 대한 고찰 (Intra Operative Radiation Therapy (IORT))

  • 김동욱;서명원
    • 대한방사선치료학회지
    • /
    • 제2권1호
    • /
    • pp.75-80
    • /
    • 1987
  • Intraoperative Radiation therapy (IORT) is a cancer treatment modality in which resectable masses or organs are removed surgically and residual cancer calls are sterilized by irradiation with a single massive dose during while patient is still anesthetized. Because it is possible that the turner mass can be visualized directly at the time of surgical exploration, tumor volume can be determined more precisely and at the same tin e sensitive adjacent structures can be pulled aside from the irradiation. With these theoretical advantages as compare to conventional external irradiation, IORT can improve the therapeutic ratio of tumor control to normal tissue injury. Yonsei cancer center initiated a pilot study of multidisciplinary IORT program in february of 1986 for the fist attempt in Korea. IORT Was performed in 7 patients with stomach cancer by using existing NELAC-1018 Linear Accelerator treatment room as a surgical suite. IOTR team included department of surgery, Department of Anethesiology, Department of Clinical pathology, operating room nursing personal and Department of radiation oncology.

  • PDF

Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident

  • Jae Seok Kim;Byeong Ryong Park;Minsu Cho;Won Il Jang;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.270-277
    • /
    • 2023
  • Exposure to ionizing radiation induces free radicals in human nails. These free radicals generate a radiation-induced signal (RIS) in electron paramagnetic resonance (EPR) spectroscopy. Compared with the RIS of tooth enamel samples, that in human nails is more affected by moisture and heat, but has the advantages of being sensitive to radiation and easy to collect. The fingernail as a biological sample is applicable in retrospective dosimetry in cases of localized hand exposure accidents. In this study, the dosimetric characteristics of fingernails were analyzed in fingernail clippings collected from Korean donors. The dose response, fading of radiation-induced and mechanically induced signals, treatment method for evaluation of background signal, minimum detectable dose, and minimum detectable mass were investigated to propose a fingernail-EPR dosimetry protocol. In addition, to validate the practicality of the protocol, blind and field experiments were performed in the laboratory and a non-destructive testing facility. The relative biases in the dose assessment result of the blind and field experiments were 8.43% and 21.68% on average between the reference and reconstructed doses. The results of this study suggest that fingernail-EPR dosimetry can be a useful method for the application of retrospective dosimetry in cases of radiological accidents.

두부규격방사선촬영장치의 두경부 피폭 저감에 대한 연구 (Study on Research for Reducing Radiation Dose of Head and Neck for Cephalometric Radiography System)

  • 오윤진;신재원;이삼열
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.291-298
    • /
    • 2016
  • 최근 국민의 소득수준 증가에 따른 소아의 교정치료 등의 관심이 커지면서 치과방사선 검사의 건수가 증가하고 있어 부정교합 및 악골과 치아의 위치변화 등을 관찰할 수 있는 두부규격방사선촬영이 빈번해지고 있다. 특히 검사 대상자가 방사선에 더욱 민감한 소아 층에 집중되어 있고 촬영 부위인 두경부에는 갑상선, 골수, 안구, 타액선 등의 방사선에 민감한 주요 장기가 위치하고 있어 피폭의 주의가 요구된다. 이에 따라 본 연구에서는 Agfa CP-G Plus 필름과 MagicMax 선량계를 이용하여 두경부규격방사선촬영장치(VATEC Pax-400C)에서 발생되는 X선의 2차원 선량분포를 측정하고 MCNPX 시뮬레이션을 통해 두경부 장기선량을 계산하였으며 피폭저감 장치를 설계하였다. 두부규격방사선촬영의 선량분포는 구강악안면의 검사 목적 부위 이외에도 두경부 전체적인 피폭이 일어나고 두경부 주요 장기 중 갑상선과 식도, 눈에서 높은 피폭선량 값을 확인하였다. 그리고 설계한 피폭저감 장치를 적용에 따라 갑상선과 식도, 눈에서 70~80% 피폭이 저감됨을 확인하였다. 본 연구 결과는 치과방사선에 대한 선량 데이터 확보와 방사선 피폭 저감 연구에 있어 매우 유용하게 이용될 것으로 기대된다.

Numerical and experimental investigation on the temperature distribution of steel tubes under solar radiation

  • Liu, Hongbo;Chen, Zhihua;Zhou, Ting
    • Structural Engineering and Mechanics
    • /
    • 제43권6호
    • /
    • pp.725-737
    • /
    • 2012
  • The temperature on steel structures is larger than the ambient air temperature under solar radiation and the temperature distribution on the affected structure is non-uniform and complicated. The steel tube, as a main structural member, has been investigated through experiment and numerical analysis. In this study, the temperature distribution on a properly designed steel tube under solar radiation is measured. A finite element transient thermal analysis method is presented and verified by the experimental results and a series of parametric studies are carried out to investigate the influence of various geometric properties and orientation on the temperature distribution. Furthermore, a simplified approach is proposed to predict the temperature distribution of steel tube. Based on both the experimental and the numerical results, it is concluded that the solar radiation has a significant effect on the temperature distribution of steel tubes. Under the solar radiation, the temperature of steel tubes is about $20.6^{\circ}C$ higher than the ambient air temperature. The temperature distribution of steel tubes is sensitive to the steel solar radiation absorption, steel tube diameter and orientation, but insensitive to the solar radiation reflectance and thickness of steel tube.

ICR 마우스의 태아(胎兒)에 대(對)한 방사선(放射線)과 초음파(超音波)의 공동효과(共同效果)에 관한 실험적(實驗的) 검토(檢討) (Combined Effects of Radiation and Ultrasound on Embryonic Development in Mice)

  • 구연화
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제14권2호
    • /
    • pp.37-44
    • /
    • 1991
  • The combined effect of radiation and ultrasound has been studied in mouse embryos. Radiation and/or ultrasound were adminstered to ICR mice on day 8 of gestation. Intrauterine death, gross malformation, and fetal body weight were selected as indicators of effects. Does of whole-body ${\gamma}-irradiation$ were 0.5 to 2.5 Gy and those of ultrasound were $0.5\;W/cm^2$ to $3\;W/cm^2$. Intrautrine mortality increased with increasing radiation dose ; this trend was more remarkable in combination with ultrasound. Gross malformations such as exencephaly and anophthalmia/microphthalmia appeared frequently in the fetuses treated with both radiation and ultrasound. Decreased fetal weight was observed even in mice treated with 1.5 Gy of radiation or $1\;W/cm^2$ of ultrasound. There was a linear relationship between dose and reduction of fetal weight. The fetal weight was sensitive, precise and easy-to-handle indicator for the effects of growth retardation. Intrauterine mortality and frequencies of exencephaly and anophthalmia/microphthalmia were higher than the sum of those induced by radiation and by ultrasound. The results indicatied that the combined action of radiation and ultrasound on intrauterine death and malformations was synergistic.

  • PDF

Radiation testing of low cost, commercial off the shelf microcontroller board

  • Fried, Tomas;Di Buono, Antonio;Cheneler, David;Cockbain, Neil;Dodds, Jonathan M.;Green, Peter R.;Lennox, Barry;Taylor, C. James;Monk, Stephen D.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3335-3343
    • /
    • 2021
  • The impact of gamma radiation on a commercial off the shelf microcontroller board has been investigated. Three different tests have been performed to ascertain the radiation tolerance of the device from a nuclear decommissioning deployment perspective. The first test analyses the effect of radiation on the output voltage of the on-board voltage regulator during irradiation. The second test evaluated the effect of gamma radiation on the voltage characteristics of analogue and digital inputs and outputs. The final test analyses the functionality of the microcontroller when using an external, shielded voltage regulator instead of the on-board voltage regulator. The results suggest that a series of latch-ups occurs in the microcontroller during irradiation, causing increased current drain which can damage the voltage regulator if it does not have short-circuit protection. The analogue to digital conversion functionality appears to be more sensitive to gamma radiation than digital and analogue output functionality. Using an external, shielded voltage regulator can prove beneficial when used for certain applications. The collected data suggests that detaching the voltage regulator can extend the lifespan of the platform up to approximately 350 Gy.

E. coli B. MQ1844 균주의 오존감수성 유전자의 특성 (A gene responsible for ozone sensitivity (ozrB) in chromosome of escherichia coli B. MQ 1844)

  • 정영섭;;최영길
    • 미생물학회지
    • /
    • 제25권2호
    • /
    • pp.103-109
    • /
    • 1987
  • An ozone-sensitive mutant of Escherichia coli strain B, MQ 1844 is described. Its properties, including high sensitivity to ozone and radiation, inducible filamentation, extensive DNA degradation and impaired DNA synthesis following ozonation, are attributable to a mutation in ozrB, a gene which is cotransducible with malB. Based on differences in phenotypic expression as well as on the particular location of this gene on the bacterial chromosome, ozrB appears as distinct from the other ozone-or radiation-sensitivity genes previously described.

  • PDF

Radiation belt electron losses induced by wave-particle interactions

  • Summers, Danny
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2009년도 한국우주과학회보 제18권2호
    • /
    • pp.32.2-32.2
    • /
    • 2009
  • We examine cyclotron resonant interactions of radiation belt electrons with VLF chorus, plasmaspheric ELF hiss and electromagnetic ion cyclotron (EMIC) waves. Bounce-averaged diffusion rates depend on wave mode, equatorial pitch-angle, electron energy and L-shell. As well, diffusion rates can be sensitive to the latitudinal distributions of particle density and wave power. For different configurations of the plasmasphere, we calculate electron precipitation loss timescales due to combined scattering by VLF chorus, ELF hiss and EMIC waves.

  • PDF