• 제목/요약/키워드: Sensing Valve

검색결과 47건 처리시간 0.022초

유압 브레이커의 자동타격력 제어기구 설계에 관한 연구 (A Study on the Automatic Impact Force Control Mechanism Design for the Hydraulic)

  • 강영기;장주섭
    • 드라이브 ㆍ 컨트롤
    • /
    • 제19권3호
    • /
    • pp.1-8
    • /
    • 2022
  • In this paper, the design of automatic impact force control mechanism of hydraulic breaker was studied. The control mechanism uses the change of piston upper chamber pressure, when the hydraulic breaker impacts various strength rock. The piston stroke is controlled by rock strength sensing valve, piston stroke switching valve, and piston control valve. It is imperative to denote the area of each valve section, the spring constant of the spring. It provides convenience to users by automatically adjusting the appropriate striking force, according to the strength of the rock. Additionally, by increasing work productivity, it can contribute to reducing greenhouse gas emissions due to fuel efficiency reduction.

Position estimation and control of SMA actuators based on electrical resistance measurement

  • Song, Gangbing;Ma, Ning;Lee, Ho-Jun
    • Smart Structures and Systems
    • /
    • 제3권2호
    • /
    • pp.189-200
    • /
    • 2007
  • As a functional material, shape memory alloy (SMA) has attracted much attention and research effort to explore its unique properties and its applications in the past few decades. Some of its properties, in particular the electrical resistance (ER) based self-sensing property of SMA, have not been fully studied. Electrical resistance of an SMA wire varies during its phase transformation. This variation is an inherent property of the SMA wire, although it is highly nonlinear with hysteresis. The relationship between the displacement and the electrical resistance of an SMA wire is deterministic and repeatable to some degree, therefore enabling the self-sensing ability of the SMA. The potential of this self-sensing ability has not received sufficient exploration so far, and even the previous studies in literature lack generality. This paper concerns the utilization of the self-sensing property of a spring-biased Nickel-Titanium (Nitinol) SMA actuator for two applications: ER feedback position control of an SMA actuator without a position sensor, and estimation of the opening of a SMA actuated valve. The use of the self-sensing property eliminates the need for a position sensor, therefore reducing the cost and size of an SMA actuator assembly. Two experimental apparatuses are fabricated to facilitate the two proposed applications, respectively. Based on open-loop testing results, the curve fitting technique is used to represent the nonlinear relationships between the displacement and the electrical resistance of the two SMA wire actuators. Using the mathematical models of the two SMA actuators, respectively, a proportional plus derivative controller is designed for control of the SMA wire actuator using only electrical resistance feedback. Consequently, the opening of the SMA actuated valve can be estimated without using an extra sensor.

온도 감지식 팽창밸브 감온통 질소가스 혼합냉매의 동특성 연구 (A Study on the Dynamic Characteristics of Nitrogen Mixed Gas for Thermostatic Expansion Valve Sensing Blub)

  • 김시영;구수진;주창식
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.69-75
    • /
    • 2014
  • The pressure and temperature characteristics of mixed refrigerant gases in bulb for thermostatic expansion valve were studied using R22 refrigerant and $N_2$ gases. The characteristics of mixed refrigerant gases were investigated according to pressure variation and the variation of composition ratio of R22 refrigerant and $N_2$ gases in the temperature range of -$15^{\circ}C$~$15^{\circ}C$. The Maximum operating pressure(MOP) of mixed refrigerant gases were showed a tendency to decrease with decreasing the mixing ratio of $N_2$ gas. The characteristics in the case of the mixing ratio of 90:1 for R22 refrigerant and $N_2$ gases were the same result as Reference refrigerant. In addition, the characteristics of the mixed refrigerant gases in the mixing ratio of 90:1 for R22 refrigerant and $N_2$ gases were showed almost linear in the measurement range of pressure-temperature, and the physical properties also were showed similar results with Reference refrigerant. It was able to confirm that a MOP on the thermostatic expansion valve for sensing bulb can be maintained by adjusting the mixing ratio of R22 refrigerant and $N_2$ gases.

부하감지시스템을 사용한 굴삭기의 유압제어특성 시뮬레이션 (A Simulation on the Hydraulic Control Characteristics of Excavator Using Load Sensing System)

  • 조승호
    • 한국정밀공학회지
    • /
    • 제15권2호
    • /
    • pp.134-145
    • /
    • 1998
  • The purpose of this paper is to construct a computer simulation system which can analyze and design the hydraulic excavator Theoretical analyses are performed on the hydraulic circuit and attachment of excavator with load sensing system. Databases are constructed for control valve opening areas, horsepower control and for load sensing regulator. For hydraulic components modularized programming techniques are applied which is expected to be utilized for software development of fluid power system. Through simulation an information of any point in hydraulic circuit can be obtained.

  • PDF

자동차 배기계의 배기압 감응형 제어 머플러 개발(1) -배기계의 일반 특성과 제어 밸브의 특성- (The Development of Muffler with Controller Sensing Exhaust Gas Pressure in Automobile Exhaust System(1) -The general characteristics of exhaust system and characteristics of control valve-)

  • 이해철;이준서;윤준규;차경옥
    • 한국자동차공학회논문집
    • /
    • 제9권1호
    • /
    • pp.37-44
    • /
    • 2001
  • This study is focused on the development of a new muffler. A control valve installed in the exhaust system is operated by torsion springs, and its open angle is controlled automatically corresponding to the engine operating conditions. The experiments were done using an exhaust system simulator having the same pulsation wave frequency and similar pulsation propagation characteristics of a real exhaust system. The purpose of this study is to develop a new muffler system which has improved noise reduction quality and less power loss than conventional mufflers and electronic-control mufflers.

  • PDF

Detection of Magnetic Nanoparticles and Fe-hemoglobin inside Red Blood Cells by Using a Highly Sensitive Spin Valve Device

  • Park, Sang-Hyun;Soh, Kwang-Sup;Hwang, Do-Guwn;Rhee, Jang-Roh;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제13권1호
    • /
    • pp.30-33
    • /
    • 2008
  • A highly sensitive, giant magnetoresistance-spin valve (GMR-SV) biosensing device with high linearity and very low hysteresis was fabricated by photolithography. The detection of magnetic nanoparticles and Fe-hemoglobin inside red blood cells using the GMR-SV biosensing device was investigated. When a sensing current of 1 mA was applied to the current electrode in the patterned active devices with an area of $2{\times}6{\mu}m^2$, the output signals were about 13.35 mV. The signal from even one drop of human blood and nanoparticles in distilled water was sufficient for their detection and analysis.

팽창밸브 개폐용 감온통 혼합가스의 첨가제 연구 (A Study on the Additives of mixed Gas charged in Thermostatic Bulb for Expansion Valve)

  • 김시영;주창식;구수진
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.126-132
    • /
    • 2014
  • The P-T characteristics of mixed refrigerant in thermostatic expansion valve sensing bulb were studied using R-134a and R-410A refrigerant. The characteristics of mixed refrigerant were investigated according to pressure variation and the variation of composition ratio of R-134A and R-410A in the temperature range of $-15^{\circ}C{\sim}15^{\circ}C$. The Thermodynamic characteristic values of the mixed refrigerants were identified using the characteristic value analysis program of mixed refrigerant(Refrop v9.0, NIST). The P-T characteristics in the case of the mixing ratio of 90:10 for R-410A and R-134A were the same result as R-22. And the physical properties showed similar results with R-22. The Maximum operating pressure(MOP) of mixed refrigerant showed a tendency to decrease with decreasing the mixing ratio of additive gases($N_2$ or He) gases. The characteristics in the case of the mixing ratio of 80:1 for mixed refrigerant and additive gases were the similar result as Reference refrigerant.(R-22 MOP, Sporlan company) In addition $N_2$ and He, both showed the same results. It was able to confirm that a MOP on the thermostatic expansion valve sensing bulb can be maintained by adjusting the mixing ratio of mixed refrigerant gases and additive gases.

차량 제동 성능 해석 프로그램 개발 (Development of Automotive Braking Performance Analysis Program Considering Dynamic Characteristic)

  • 정일호;이수호;서종휘;박태원
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.175-181
    • /
    • 2004
  • Analysis of brake characteristics has progressed rapidly in recent years, as computer techniques have developed. However, there are many problems in predicting braking characteristics, due to the numerous design variables of the brake system. Therefore, a synthetic braking performance analysis is required for all brake system parts such as master cylinder, booster, control valve and split system. In this paper, a program which can analyze braking performance such as force distribution, braking efficiency, pedal force and pedal travel, is presented. The preprocessor of the program helps users prepare input files through a dialog box. An additional postprocessor makes the graph presentation of solved results. Also, a simple example problem is applied to show the usefulness of the presented program.

시설원예(施設園藝)에 있어서 재배관리(栽培管理)의 자동화(自動化) 시스템에 관(關)한 연구(硏究) (I) -물관리 자동화(自動化)- (A Microcomputer-Based Control System for Green House (I) -Water Management-)

  • 이기명;박규식
    • Journal of Biosystems Engineering
    • /
    • 제11권1호
    • /
    • pp.31-36
    • /
    • 1986
  • As a part of study on automatic control system for green houses, an automatic irrigation system was developed by using microcomputer. For the study, gypsum block was used as a sensing device of soil moisture and its data was designed to transfer to microcomputer through A/D converter. Also, software which be able to control the irrigation time and flow rate by the solenoid valve was developed. This system was tested by using practical data and the following results were summarized. 1. Since the gypsum was very accurate in addition with chiep and easy to manufacture, it turned out to be a very good device to detect the soil moisture in this system. 2. Also, solenoid valve was very excellent device for controlling the water flow rate since its control error is less then 1% when the irrigation time is over 100 seconds.

  • PDF

스핀밸브 바이오 센서를 이용한 혈액과 나노입자의 자성특성 검출 (The Detection of Magnetic Properties in Blood and Nanoparticles using Spin Valve Biosensor)

  • 박상현;소광섭;안명천;황도근;이상석
    • 한국자기학회지
    • /
    • 제16권3호
    • /
    • pp.157-162
    • /
    • 2006
  • 이온빔 증착 스퍼터링법과 고아 리소그래피법으로 FeMn-스핀밸브 바이오 센서를 제작하였다. 혈액내의 Fe를 포함한 헤모글로빈(Hemoglobin)과 나노 자성입자의 자성검출은 최대 자장감응 약 $0.1{\sim}0.8%/Oe$인 거대자기저항 스핀밸브 바이오 센싱소자를 이용하였다. 사용된 혈액은 인체의 피였고, Co-페라이트 나노 자성입자는 수용성 무정형 실리카로 코팅이 되었으며, 그 크기의 평균직경의 범위는 9nm에서 50nm이었다. 실제 크기가 $5x10{\mu}m^2 $ 혹은 $2x6{\mu}m^2 $로 제작된 센싱소자의 4 전극 중 전류 입력단자에 흐르는 감지전류는 1 mA로 하였다. 혈액과 나노자성 입자가 소자의 중앙부분으로 떨어졌을 때, 출력신호는 각각 자성 여부의 검출 특성을 알 수 있는 충분한 크기로 나타났다.