• 제목/요약/키워드: Sensible Heat

검색결과 332건 처리시간 0.031초

열교환기 휜에서의 착상 거동 (Behavior of frost formed on heat exchanger fins)

  • 김정수;이관수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2334-2339
    • /
    • 2008
  • This paper proposes an improved mathematical model for predicting the frosting behavior on a two-dimensional fin considering the heat conduction of heat exchanger fins under frosting conditions. The model consists of laminar flow equation in airflow, diffusion equation of water vapor for frost layer, and heat conduction equation in fin, and these are coupled together. In this model, the change in three-dimensional airside airflow caused by frost growth is accounted for. The fin surface temperature increased toward the fin tip due to the fin heat conduction. On the contrary, the temperature gradient in the airflow direction(x-dir.) is small throughout the entire fin. The frost thickness in the direction perpendicular to airflow, i.e. z-dir., decreases exponentially toward the fin tip due to non-uniform temperature distribution. The rate of decrease of heat transfer in the airflow direction is high compared to that in the z-direction due to more decrease in the sensible and latent heat rate in x-direction.

  • PDF

Analysis of a Wet Surface Finned-tube Evaporator of an Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.211-219
    • /
    • 2002
  • In this study, in-situ performance test of a wet surface finned-tube evaporator of an air source heat pump which has a rating capacity of 20 RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. From the experimental data, air side heat and mass transfer coefficients were calculated by the well known heat and mass transfer analogy and tube-by-tube method. Since current procedure underpredicted the experimental sensible heat factor (SHF), a proper empirical parameter was introduced to predict the experimental data with satisfactory results. This study provides the method of evaluating the heat and mass transfer coefficients of a wet surface finned-tube evaporator of which in-situ performance test is necessary.

T-history법에 의한 잠열량 측정 정확도의 향상 (Accuracy Improvement for Measurement of Heat of Fusion by T-history Method)

  • 박창현;백종현;강채동;홍희기
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.652-660
    • /
    • 2003
  • T-history method, measuring heat-of-fusion of phase change material (PCM) in sealed tubes, has the advantages of a simple experimental device and no requirements in sampling process. However, a degree of supercooling used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion in the original method, which has been improved in order to predict better results by us. In the present study, the modified method was applied to a variety of PCM such as paraffin and lauric acid having very small or no supercooling with a satisfactory precision. Also the selection of inflection point and temperature measurement position was fumed out not to affect the accuracy of heat-of-fusion significantly. As a result, the method can provide an appropriate means to assess a new developed PCM by cycle test even if a very accurate value cannot be obtained.

간접식 증발냉각장치의 성능예측과 에너지절약에 관한 연구 (Study on Performance Prediction and Energy Saving of Indirect Evaporative Cooling System)

  • 유성연;김태호;김명호
    • 대한기계학회논문집B
    • /
    • 제39권9호
    • /
    • pp.743-749
    • /
    • 2015
  • 본 연구의 목적은 간접식 증발냉각 장치의 성능을 예측하고, 장치를 공기조화기의 배기열 회수에 적용하였을 경우의 에너지 절약효과를 분석하는 것이다. 플라스틱 열교환기를 사용한 간접식 증발냉각장치의 성능 상관식을 여러가지 조건에서 얻어진 실험 데이터로부터 구하였으며, 이 상관식을 이용하여 환기와 외기의 조건을 변화시켜가면서 장치의 성능변화를 예측하였다. 또한 간접식 증발냉각장치의 배기열 회수에 의한 에너지 절약효과를 우리나라 몇개 도시의 표준기상데이터를 사용하여 분석하였다. 여름철 배기열 회수를 위한 현열냉각장치의 사용율은 평균 44.3%이며 증발냉각장치의 사용율은 96.7% 이다. 증발냉각장치의 배기열 회수에 의한 에너지 절약은 현열냉각장치에 비해서 훨씬 높으며, 서울의 경우 약 3.89 배로 나타났다.

Development of Spatial Data Management System to Estimate Regional Evapotranspiration Using a Land Surface Parameterization

  • Kim, Kwang-Soo;Chung, U-Ran
    • 한국농림기상학회:학술대회논문집
    • /
    • 한국농림기상학회 2003년도 춘계 학술발표논문집
    • /
    • pp.58-61
    • /
    • 2003
  • A land surface parameterization has been used to simulate influences of the terrestrial surface on the atmosphere. A simple biosphere model (SiB2), one of land surface parameterization, calculates exchange of radiation, sensible heat, latent heat, and momentum between the surface and the atmosphere (Sellers, et al., 1996).(omitted)

  • PDF

Derivation of a Simplified Heat Transfer Correlation for AP 600 Passive Containment Cooling System

  • Chung, Bum-Jin
    • 에너지공학
    • /
    • 제7권1호
    • /
    • pp.122-130
    • /
    • 1998
  • A simplified heat transfer model for the cooling capability of the AP 600 PCCS is proposed I this paper. As the PCCS domain is covered with very thin and long water film, it is phenomenologically divided into 3 regions; water entrance effect region, asymptotic region, and air entrance effect region. As the length of the asymptotic region is estimated to be over 90% of the whole domain, the phenomena in the asymptotic region is focused. Using the analogy between heat and mass transfer phenomena in a turbulent situation, a new dependent variable combining temperature and vapor mass fraction was defined. The similarity between the PCCs phenomena in the asymptotic region and the buoyant air flow phenomena on a vertical heated plate is derived. Using the similarity, the simplified heat transfer correlations for the interfacial heat fluxes and the ratios of latent heat transfer to sensible heat transfer were established. To verify the accuracy of the correlation, the results of this study were compared with those of other numerical analyses performed for the same configuration and they are well within the range of 15% difference.

  • PDF

고온 축열 시스템의 개발에 관한 연구 (A System Development of Thermal Energy Storage at High Temperatures)

  • 홍성안;박원훈;최형준
    • 태양에너지
    • /
    • 제8권1호
    • /
    • pp.13-21
    • /
    • 1988
  • Heat transfer phenomena in a high-temperature heat storage unit were investigated using molten salts. Carbonate salt, an equimolar mixture of $Li_2CO_3$ and $K_2CO_3$, which melts at $505^{\circ}C$ with a latent heat of 82 cal/g, was selected as the most promising latent heat storage material based on its low cost and excellent thermophysical properties at moderately high temperatures. It was also found that nitrate salts were good candidates of sensible heat storage materials. For the carbonate salt to be utilized commercially, however, several means of enhancing thermal recovery must be explored by promoting heat conduction through the solid salt formed during the heat discharge period. These would be achieved by the additions of aluminum screens and wool, and stainless fins. Finally, experimental results of moving boundary of phase change were well compared with predictied values obtained from the approximate solution.

  • PDF

PCM의 잠열측정을 위한 T-history법에 대한 고찰 (Consideration on the T-history Method for Measuring Heat of Fusion of Phase Change Materials)

  • 박창현;최주환;홍희기
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1223-1229
    • /
    • 2001
  • Though conventional calorimetry methods such as differential scanning calorimetry (DSC) and differential thermal analysis (DTA) are used generally in measuring heat of fusion, T-history method has the advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermal properties of inhomogeneous phase change materials (PCMs) in sealed tubes. However, random criteria (a degree of supercooling) used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

  • PDF

Improvement of the T-history Method to Measure Heat of Fusion for Phase Change Materials

  • Hong, Hi-Ki;Park, Chang-Hyun;Choi, Ju-Hwan;Peek, Jong-Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권1호
    • /
    • pp.32-39
    • /
    • 2003
  • Though conventional calorimetry methods such as differential scanning calorimetry and differential thermal analysis are used generally in measuring heat of fusion, T-history method has advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermophyical properties of in-homogeneous phase change materials in sealed tubes. However, the degree of supercooling used in selecting a range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

반도체 식각 공정용 냉각 시스템 구축을 위한 AMESim 모델 개발 (A Study on the Development of AMESim Model for Construction of Cooling System for Semiconductor Etching Process)

  • 김대현;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제16권3호
    • /
    • pp.106-110
    • /
    • 2017
  • Due to the plasma applied from the outside, which acts as an etchant during the etching process, considerable heat is transferred to the wafer and a separate cooling process is performed to effectively remove the heat after the process. In this case, a direct cooling method using a refrigerant is suitable for cooling through effective heat exchange. The direct cooling method using the refrigerant using the latent heat exchange is superior to the cooling method using the sensible heat exchange. Therefore, in this paper, AMESim is used to design a direct refrigerant cooling system using latent heat exchange simulator was built.The constructed simulator is reliable compared with the actual experimental results. It is expected that this simulator will help to design and search for optimal process conditions.

  • PDF