• 제목/요약/키워드: Sensations

검색결과 283건 처리시간 0.023초

범불안장애 환자의 스트레스 대처방식과 신체증상 지각에 대한 인지적 특성 (Stress Coping Strategies and Cognitive Characteristics of Somatic Symptom Perception in Patients with Generalized Anxiety Disorder)

  • 김용;박종일;박태원;정상근;양종철
    • 대한불안의학회지
    • /
    • 제13권2호
    • /
    • pp.100-107
    • /
    • 2017
  • Objective : The purpose of this study was to investigate strategies used to cope with stress and the cognitive characteristics of somatic symptom perception in patients with generalized anxiety disorder(GAD). Methods : A total of 55 patients meeting DSM-5 criteria for GAD and 55 normal controls were recruited for participation in this study. We evaluated subjects using The Way of Stress Coping Questionnaire (SCQ), Somato-Sensory Amplification Scale (SSAS), Symptom Interpretation Questionnaire (SIQ), and the Generalized Anxiety Disorder for 7 Item (GAD-7). We analyzed data using an independent t-test and Pearson's correlation analysis. Results : In terms of SCQ, GAD patients presented significantly lower scores on seeking social support and higher scores on wishful thinking than normal controls. GAD patients had significantly greater amplification of physical sensation in SSAS and higher scores in physical, psychological interpretation subsets of SIQ than normal controls. GAD-7 scores were positively correlated with physical interpretation scores on SIQ. Conclusion : Results reveal that patients with GAD have insufficient coping strategies for stress, greater amplification of body sensations, and tendency towards a physical, psychological interpretation of somatic symptoms.

전기자극의 강도와 측정전극의 간격이 감각신경신호의 파라미터에 미치는 영향 연구 (The Effects of the Stimulation Intensity and Inter-Electrode Distance on the Parameters of the Measured Sensory Nerve Signal)

  • 임경민;송동진
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.234-241
    • /
    • 2014
  • This study was designed to investigate the effects of stimulation intensity and inter-electrode distance on the parameters of the measured sensory nerve signal. 30 healthy subjects participated in this study. Sensory nerve signals were elicited by four different pulse amplitudes, i.e., 3, 6, 9, 12 mA, with the pulse width fixed at $500{\mu}s$. The sensory nerve signals elicited by the four different pulse amplitudes were measured by four different inter-electrode distances (20, 30, 40, and 50 mm). We extracted four parameters (pulse amplitude, pulse width, pulse area, and latency time from stimulation) from the sensory nerve signals. The measured pulse amplitude and pulse width were increased when the measuring inter-electrode distance was increased while the stimulating pulse amplitude was fixed. The measured pulse amplitude was saturated with the stimulating pulse amplitudes of over 6 mA while measuring inter-electrode distance. Under the same condition, measured pulse width was increased, and sensory nerve signal was initiated early. Sensory nerve signals, specially those of pulse amplitude, were distorted by a differential amplification method that commonly measures the human body signal. The experimental results indicate that the differential amplification method is required to be replaced when measuring nerve signals. Our observations suggested that the hyperpolarization of the action potential of the sensory nerve signal for preventing distortion could be used to clarify the correlation between the parameters of the sensory nerve signals and quantification of sensations.

인체의 동작을 고려한 스케이트 팬츠 패턴 개발 (Pattern Development of Skate Pants Allowing for Dynamic Movement and Postures)

  • 정연희
    • 한국생활과학회지
    • /
    • 제17권1호
    • /
    • pp.115-126
    • /
    • 2008
  • The construction of an athlete's tight-fitting garments is very important to the wearer in terms of athletic performance. Therefore pattern development of tight-fitting garments must allow for the full range of human movement and postures. In this study the relationship between the construction of a skate pants pattern and clothing fitting was explored with the aim of improving the comfort of the clothing. The four male subjects were university students between the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using a seven-point Likert scale on four consecutive days. While wearing the garments, subjects were asked to take five different postures including waist flexion, sitting and others. A Likert-type scale was used for the evaluation, with 7 points indicating the best fit in tight-fitting pants. Results showed differences in the front-rise length and back-rise length between basic pants(A) and modified pants(B,C,D) were -5.16cm and +5.64cm. Comparing the basic pants pattern(A) with modified pants pattern(B), the latter was superior to basic pants(A) in terms of pressure sensation and closeness of fit, but there was no significant difference. Among the four tight-fitting skate pants, A and B pants were superior to the others in terms of fitting and stability of waist and hip sections. In the case of the skate pants, the number of cutting lines in the pattern had an influence on clothing comfort. A minimum cutting line for tight skate pants was better than a maximum cutting line in terms of clothing comfort.

기능성 작업복의 인간공학적 평가 - 방염복을 중심으로 - (Ergonomic Evaluation of Functional Working-Clothes - Focused on Flame-Proof Clothing -)

  • 김희은;연수민;정정림;이민정;장준호;유희천
    • 한국의류산업학회지
    • /
    • 제8권5호
    • /
    • pp.597-603
    • /
    • 2006
  • This study was aimed to find out the problems of wearing flame-proof clothing and to analytically assess functional working-clothes, thus to propose a new design. We carried out a questionnaire with workers in the field and evaluated the facility for wearing, the sensation of wearing and clothing microclimate in the environmental chamber. We found out the problems were in the parts of neck, armpits, armhole, sleeve, crotch and suspenders. Thermal sensation, wet sensation and comfort sensations were evaluated to be 'hot', 'wet' and near to discomfort', respectively. Therefore, improvement of movement and air permeability is needed. If we can add gusset on armpit for air permeability, this gusset will enable to enlarge the surface in armpit area and finally give a movement efficiency. We suggested several new partly modified design for flame-proof clothing which can be applied to other protective clothing for improvement. This must be further considered in the ergonomic evaluation of new proposed functional working-clothes as well as in the suggestion of design.

청간소요산으로 호전된 설통 환자 3례 (Three Case Reports of Glossodynia Patients Treated with Cheonggansoyo-san)

  • 김연진;양승보;김정화;이상화;조승연;박성욱;박정미;고창남
    • 대한한방내과학회지
    • /
    • 제38권4호
    • /
    • pp.491-500
    • /
    • 2017
  • Objectives: This clinical study reports the effects of Cheonggansoyo-san (CSS) on three patients with glossodynia. Methods: Three patients with glossodynia were treated with CSS (i.e., an herbal medicine) and acupuncture. Numeric rating scales (NRSs) for glossodynia and dry mouth and hwa-byung questionnaire scores were evaluated, and the results from heart rate variability (HRV) evaluations were analyzed. Results: After treatment with CSS, three patients' glossodynia symptoms, such as burning sensations, tingling, and numbness of the tongue, were improved. NRS ratings for glossodynia and dry mouth and the hwa-byung questionnaire scores also improved, and HRV parameters were closer to the normal range. Conclusion: Cheonggansoyo-san could be used to treat glossodynia.

실리콘 태양전지를 활용한 공기순환 의복의 태양광 입사각에 따른 효율성 및 쾌적성평가 (Efficiency and Comfort Properties of Silicon Solar Cell Applied Air Circulation Jacket according to the Incident Angle of Sunlight)

  • 이지연;조아라;정예리;김은애
    • 한국의류학회지
    • /
    • 제33권11호
    • /
    • pp.1806-1816
    • /
    • 2009
  • This study analyzes the efficiency of a solar cell attached to an air circulation jacket. A commercially available silicon solar panel was selected and attached at four spots where the body angle was $40-60^{\circ}$ and voltage ($V_{oc}$, V), current ($I_{sc}$, A), and output power (P, W) were measured to determine the efficiency. The solar panel was applied to the outer jacket that operates with two fans to increase the convection that lowers the body temperature. The heavy work of standing, walking, and sweeping of a street sweeper was simulated in the field test. The microclimate within the jacket (with or without a fan) was measured and the subjective thermal, humidity, and comfort sensations were surveyed. SPSS 12.0 statistical package was used for a t-test and Wilcoxon signed-rank test. The results show that the highest efficiency of the solar cell was at the incident angle of $60^{\circ}$ in terms of voltage, current and output power distribution. The microclimate temperature of the air circulation jacket decreased significantly with the high power of the fan and subjects felt cooler than the jacket with a fan at the incident angle of $60^{\circ}$. Air circulation jackets operated by a silicon solar panel showed a significant cooling effect on the wearers.

선호감성 어휘분석을 통한 남녀 대학생의 감성 유형화 (Grouping Preferred Sensations of College Students Using Sementic Differential Methods of Sensation Words)

  • 나영주;조길수
    • 감성과학
    • /
    • 제5권1호
    • /
    • pp.9-16
    • /
    • 2002
  • 98가지 감성 형용사를 수집하여 176명의 남녀 대학생을 대상으로 SD법에 의해 선호도를 조사한 결과, 개인차가 큰 감성어휘에는 '매니쉬, 수공예적인, 귀족적인, 섹시'등의 중간정도의 선호도를 나타내는 감성어휘들이 포함되었으며, 개인차가 적은 어휘로는 '건조한, 인공적인'등의 비선호감성과 '멋스런, 유연한'등의 선호감성이 있었다. 선호감성에 의해 남녀 대학생들을 유형화시키면 남녀 대학생의 선호감성은 크게 10가지로 나타났다. 대부분의 대학생들이 '캐주얼파'였으나(32.4%), 이는 다시 '비장식 개성 캐주얼파, 역동적 쿨개성 캐주얼파, 정성청결 캐주얼파'로 세분화되었다. 다음으로 많은 대학생들이 '로맨틱 모던파'(21.4%)였으며, 그 다음으로는 '단순 내추럴파'(17.3%)였다. 또한 '클래식파(9.2%-수공예 로맨틱 클래식파, 획일적 클래식파)', '비표현파'(8.7%). '호화개성 복고파'(7.4%), '민족감성 선호파'(4.6%) 등이 있었다. 감성어휘와 대학생의 집단들은 크게 두 개의 선호감성축(정적-동적, 경량-중량)을 중심으로 가시적으로 함께 그룹화/도식화될 수 있었다.

  • PDF

Clothing Temperature Changes of Phase Change Material-Treated Warm-up in Cold and Warm Environments

  • Choi Kyeyoun;Chung Hyejin;Lee Boram;Chung Kyunghee;Cho Gilsoo;Park Mikyung;Kim Yonkyu;Watanuki Shigeki
    • Fibers and Polymers
    • /
    • 제6권4호
    • /
    • pp.343-347
    • /
    • 2005
  • The purpose of this study was to investigate the appropriate amounts of phase change materials to give objective and subjective wear sensations. Vapor-permeable water-repellent fabrics with (WR-PCM) and without (WR) octadecane containing microcapsules were obtained by wet-porous coating process. Then, calculating the area of the WR-PCM treated clothes, we estimated the total calories of the clothing by multiplying the heat of fusion and heat of crystallization of PCM to the calculated area. Wear tests were conducted in both warm environment $(30^{\circ}C,\;65\%\;RH)$ and cold environment $(5^{\circ}C,\;65\%\;RH)$ with sports warm up style experimental garments made with WR and WR-PCM fabrics. Rectal, skin, and clothing microclimate temperatures, saliva and subjective evaluation measurements were done during the wear test. There was no difference of rectal and mean skin temperatures between WR and WR-PCM, but the clothing microclimate temperature of WR-PCM under warm environment was slightly lower than that of WR. In cold environment, WR-PCM showed much higher temperature than in WR. Saliva change did not appear between clothes, but did between two environments. Although subjective sensation between WR and WR-PCM was not significantly different, WR-PCM was rated as cooler than WR in warm environment and as warmer than WR in cold environment. The results of this study indicated that octadecane containing microcapsules in water-repellent fabric provide cooling effect.

브래지어의 착용에 따른 인체 생리반응 (Physiological Reaction to Brassiere Use)

  • 이소영
    • 복식
    • /
    • 제63권4호
    • /
    • pp.132-142
    • /
    • 2013
  • This study has evaluated the physiological reaction to wearing brassiere as well as the sensations that the wearer feels in order to understand the effect of brassiere use on the human body. Six healthy women in their twenties were used as subjects and the experiment measured the difference in their S.C.L, Skin Temperature, B.V.P and Pulse. The measurements were made in the following conditions: Women not wearing any brassiere, women wearing sports brassiere, and the women wearing wire brassiere. The results showed significant differences in the following areas. 1. S.C.L was found to be the highest when they didn't wear any brassiere, followed by when they wore wire-brassiere and then sports brassiere. 2. The Skin Temperature was found to be the highest when they wore wire-brassiere, followed by when they wore sports brassiere and when they didn't wear any of them. In particular, when they wore sports brassiere, the B.V.P was found to be the highest when they wore none of them, fir skin temperature dropped as time passed. 3.ollowed by when they wore sports brassiere and then wire brassiere. When they wore sports brassiere, they had irregular blood-flow. 4. Pulse was found to be the highest when they didn't wear any of them, followed by when they wore sports brassiere and then wire brassiere. 5. Those who didn't wear any brassiere felt the most chill, followed by those wearing wire brassiere and then sports brassiere. The moisture level was found to be the highest when they wore sports brassiere, followed by when they wore wire brassiere and then when they wore none of them. Comfort level was found to be the best with no brassiere, followed by wire brassiere and then sports brassiere.

여름철 냉감성 의류소재 개발을 위한 비스코스 레이온 중심의 직물 제조 및 PCM 가공 (Preparation of Rayon Filament based Woven Fabric and PCM Treatment for Developing Cool Touch Summer Clothing Material)

  • 홍경화
    • 한국의류산업학회지
    • /
    • 제16권2호
    • /
    • pp.326-332
    • /
    • 2014
  • To develop cool touch feeling fabrics for summer clothing material, it was manufactured several compositions of woven fabrics, having rayon multi-filament yarn (non-twisted) as warp and various kinds of yarn, such as viscose rayon multi-filament yarn (twisted), tencel$^{(R)}$ spun yarn, PET high absorbance quick dry filament yarn, and PET based rayon-like yarn, as weft. After preparing the fabrics, basic properties of the fabrics were investigated, such as air-permeability, tensile strength, absorption rate, drying rate, etc. Also, surface warm / cool sensations of the woven fabrics were assessed by Qmax Warm / Cool Touch Tester. It was observed that the fabrics composed of viscose rayon multi-filament yarn (warp) and PET high absorbance quick dry filament yarn (weft) showed excellent surface cool touch sensation-the highest Qmax value. This is because the fabric having flat shaped PET high absorbance quick dry filament shows the largest contact area with Qmax measuring plate. And, the fabric also showed superior high absorbance and quick dry property as expected. In addition, we treated phase change material (PCM) on the surface of the fabric composed of viscose rayon multi-filament yarn (warp) and PET high absorbance quick dry filament yarn(weft) to improve the cool touch feeling. However, the surface cool touch feeling was impaired by resin treated with PCM during the finishing process.