• Title/Summary/Keyword: Sensations

Search Result 283, Processing Time 0.022 seconds

A Biophilic Design Color Palette Using Natural Landscape Image (자연경관 이미지를 활용한 바이오필릭 디자인 색채 팔레트)

  • Lee, Eun-Ji;Park, Sung-Jun
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.12
    • /
    • pp.31-41
    • /
    • 2019
  • Biophilic design gives human beings positive and valuable experiences in nature. The experience in nature in the architectural environment is mainly symbolic and metaphorical, and is based on visual sensations such as color, form, and image. Recently, modern people living in a modern and simple style indoor space have a desire to pursue visual stimuli for interest or pleasure. This desire can be satisfied through color, lighting, and finishing plan. Therefore, the purpose of this study is to propose a biophilic design color palette based on the empirical characteristics and properties of biophilic design. The methods used in this study are as follows. First, the biophilic design factors and natural landscape preference criteria are examined. Second, based on the review results, natural landscape images are selected and color information for each biophilic design element is extracted according to the vertical and horizontal directions. Third, color information is converted to NCS color code and palette range and hue range are derived through the analysis of ratio and average values. Finally, based on the analysis results, biophilic design color palette is proposed for each element. The results of this study might be useful as basic data in establishing biophilic design strategies and applying them to architecture and interior construction.

Edema and hematoma after local anesthesia via posterior superior alveolar nerve block: a case report

  • Marques, Aline Louise Nascimento;Figueroba, Sidney R.;Mafra, Marco Antonio Tridapalli;Groppo, Francisco Carlos
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.3
    • /
    • pp.227-231
    • /
    • 2022
  • Although rare, complications can occur with anesthetic procedures. The posterior superior alveolar nerve (PSAN) block anesthetic technique has a high success rate, but positive aspiration can cause bruising, transient diplopia, blurred vision, and temporary blindness in approximately 3% cases. When edema occurs, it is occasionally massive, especially in the infratemporal fossa, and the resulting hematoma is usually unsightly. A 20-year-old woman presented with massive edema followed by hematoma in the upper right jaw immediately after PSAN block administration, which subsequently spread to the oral mucosa. The patient did not report any complications during the anesthetic procedure. However, after the injection was administered, the patient experienced anesthetic sensations, which rapidly evolved to facial edema. There was mild pain, but without intraoral or extraoral bleeding. The patient was prescribed medicines and instructed to perform contrast therapy. Although hematomas and edema are rare, they are difficult to prevent. The choice of local anesthetic and appropriate application of the anesthetic technique can minimize their occurrence.

Operative Resection of a Chronic Flail Chest Nonunion Revealing Septic Pseudarthrosis: A Case Report

  • Robin Deville;Justin Issard;Anna Vayssette;Jalal Assouad
    • Journal of Chest Surgery
    • /
    • v.56 no.6
    • /
    • pp.449-451
    • /
    • 2023
  • We report a case of chest wall resection for painful chest wall nonunion, 5 years after traumatic flail chest and a first attempt at surgical treatment. The decision was made to perform surgery again after 2 years of unsuccessful well-conducted analgesic treatment. During surgery, we found the same sites of pseudarthrosis and decided to perform parietectomy of the fifth, sixth, and seventh ribs. A Gore-Tex patch was used to bridge the gap created by the resection. In immediate postoperative care, the patient's pain was quickly and sufficiently eased by stage 1 and 2 pain killers. The results of bone samples taken from the pseudarthrosis sites all found Propionibacterium acnes. Five months after surgery, the patient had considerable improvement in pain sensations. Computed tomography showed healing of ribs, the plate in place, and no sign of complications.

Thermophysiological Responses to the Alternation of Exercise and Rest at $20^{\circ}C$ when Wearing Underwear made of Cotton or Wool

  • Park Shin-Jung;Chang Jee-Hye;Tokura Hiromi
    • International Journal of Human Ecology
    • /
    • v.6 no.2
    • /
    • pp.1-9
    • /
    • 2005
  • The purpose of this study was to investigate the effects of two kinds of underwear material on subjects exercising and resting in an ambient temperature of $20^{\circ}C$, a relative humidity of 60% and an air velocity of 0.13m $see^{-1}$. Two kinds of underwear ensemble were tested, differing in their hygroscopic properties: 100% wool (W) with higher moisture regain and 100% cotton (C) with lower moisture regain. Five young females served as subjects. The experiments comprised two repeated periods of 15 min exercise on a treadmill with a speed of 6km $h^{-1}$ followed by 10 min rest. The main results were as follows: 1) Mean skin temperature was significantly higher in W than in C throughout the whole experimental period (p<0.05). 2) The temperature and humidity of the microclimate between the skin and underwear provided by the first layer of clothing was higher in W than in C (p<0.1 and p<0.05, for temperature and humidity, respectively). 3) Heart rate was significantly higher in W than in C (p<0.05). 4) Subjects felt warmer during the second exercise session when wearing wool rather than cotton (p<0.05), and they also reported more increased wetness during the second exercise and rest periods in W than in C (p<0.05). These results suggest that underwear made of wool with higher moisture regain might not act as effectively as cotton to transfer exercise-induced heat from the body to the surrounding air when light exercise is taken in a thermally-neutral environment.

A Study on Quantitative Wear Training for the Improvement of Heat Tolerance in Summer (Part I) -20's Females' Optimal Wearing: Focus on Inside Clothing Temperatures in Pre-summer- (여름철 내열성 증진을 위한 정량적 착의훈련의 효과 (제1보) -20대 여성의 적정착의 온도 설정: 의복내 온도를 중심으로-)

  • Lee, Hyo-Hyun;Choi, Jeong-Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.3
    • /
    • pp.259-268
    • /
    • 2012
  • This study suggests quantitative guidelines for inside clothing temperatures to improve the heat tolerance of 20's females in summer. First, the inside clothing temperatures ($T_{cl}$) of each subject was measured in daily use. The subjects were asked to record subjective thermal sensations, clothing items worn, clothing weight, and activities during an experiment designed to determine the comfort zone of $T_{cl}$. In a thermally neutral state, the comfort zone of $T_{cl}$ was decided on a mean value $T_{cl}{\pm}1{\sigma}$. Second, the subjects were asked to wear clothing that would enable them to feel 'slightly warm but still comfortable'. The rest of the processes were the same as previous steps that were designed to understand the way and degree of clothing control. The comfort zone of $T_{cl}$ was decided in the same manner as the previous step. The two comfort zones were combined and named the combined comfort zone of the definitive comfort zone. The results were as follows: 1. Thermally comfortable $T_{cl}$, Hcl were $34.0{\pm}1.1^{\circ}C$, $40{\pm}9%%RH$ and the thermally comfortable ambient climate was $25.0{\pm}1.6^{\circ}C$, $53{\pm}7%$RH. 2. When subjects were asked to wear 'slightly warm but still comfortable', there were difference in thermally comfortable $T_{cl}$, clothing weight and clothing layer by subject. 3. In this study, the optimal $T_{cl}$ was decided on the mid-point of the definitive comfort zone of $T_{cl}$.

A Study of Influencing Factors in Acupuncture De Qi Sensation (득기 감각에 영향을 미치는 인자에 대한 연구)

  • Shin, Kyung Min;Jung, Dal Lim;Kim, Eun Jung;Lee, Seung Deok
    • The Journal of Korean Medicine
    • /
    • v.34 no.1
    • /
    • pp.15-28
    • /
    • 2013
  • Objectives: The purpose of this study was to investigate the differences in kind, intensity and depth of de Qi sensation by patients' gender, age, BMI and sensitivity. Methods: Sixty-four healthy volunteers (mean age $26.51{\pm}4.72$, range 22-39) who had been studying anatomy, meridianology, acupuncture & moxibustion for more than five years at Dongguk University, Go-yang, Korea, were invited to take part in an investigation of the sensations associated with acupuncture needling. Needling was self-administered on Hegu (LI4) in the hand and Zusanli (ST36) in the leg randomly. After obtaining de Qi, the participants were asked the kind, intensity and depth of de Qi sensation. Results: There was no statistically significant difference in the kind of de Qi sensation found by acupoints and needling methods (p>0.05). Hegu (LI4) was found to be significantly higher in the intensity (p<0.001), and the depth of de Qi sensation was significantly higher in Zusanli (ST36) than Hegu (LI4) (p<0.001). There was statistically significant difference found in the intensity of de Qi sensation by depth and sensitivity (p<0.05). In the depth of de Qi sensation, there was statistically significant difference found by sensitivity (p<0.05). In de Qi sensation of practitioners, there was statistically significant difference found by gender, BMI, the intensity of de Qi sensation (VAS) and sensitivity. Conclusions: Further study involving acupuncture de Qi sensation and the influencing factors is needed.

Silicone Implant-Based Paranasal Augmentation for Mild Midface Concavity

  • Kim, Joo Hyun;Jung, Min Su;Lee, Byeong Ho;Jeong, Hii Sun;Suh, In Suck;Ahn, Duk Kyun
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.1
    • /
    • pp.20-24
    • /
    • 2016
  • Background: Midface concavity is a relatively common facial feature in East Asian populations. Paranasal augmentation is becoming an increasingly popular procedure for patients with mild concavity and normal occlusion. In this study, we evaluate clinical outcomes following a series of paranasal augmentation. Methods: A retrospective review was performed for patients with Class I occlusion who had undergone bilateral paranasal augmentation using custom-made silicone implants, between October 2005 and September 2013. Patient charts were reviewed for demographic information, concomitant operations, and postoperative complications. Preoperative and postoperative (1-month) photographs were used to evaluate operative outcome. Results: The review identified a total of 93 patients meeting study criteria. Overall, aesthetic outcomes were satisfactory. Five-millimeter thick silicone implant was used in 81 cases, and the mean augmentation was 4.26 mm for this thickness. Among the 93 patients, 2 patients required immediate implant removal due to discomfort. An additional 3 patients experienced implant migration without any extrusion. Nine patients complained of transient paresthesia, which had resolved by 2 weeks. There were no cases of hematoma or infection. All patients reported improvement in their lateral profile and were pleased at follow-up. Complications that arose postoperatively included 9 cases of numbness in the upper lip and 3 cases of implant migration. All cases yielded satisfactory results without persisting complications. Sensations were fully restored postoperatively after 1 to 2 weeks. Conclusion: Paranasal augmentation with custom-made silicone implants is a simple, safe, and inexpensive method that can readily improve the lateral profile of a patient with normal occlusion. When combined with other aesthetic procedures, paranasal augmentation can synergistically improve outcome and lead to greater patient satisfaction.

Development of Cooling Garment for Extremely Hot Environment Using a Peltier Device and its Comfort Properties (고온환경 작업을 위한 펠티어 소자 냉각복 개발 및 쾌적성 평가)

  • Jung, Ye-Lee;Chae, Young-Jin;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • This paper reports on a prototype cooling garment applying a cooling module. The cooling module was composed of a Peltier device, a cold sink, a heat sink and two fans. A constant box was used to evaluate the cooling effect of the module. Two cooling modules were attached on each side of the garment. The wear trial was conducted using 10 male subjects in an environmental chamber maintained at $30{\pm}0.5^{\circ}C$, $50{\pm}5%$RH. Subjective sensations of thermal, humidity, and comfort were surveyed. Statistical package SPSS12.0 was used for the t-test and the Wilcoxon signed-rank test. The results showed that most effective cooling module decreased the temperature of the constant temperature box by $-4.9^{\circ}C$. The micro-temperature of the cooling garment with a Peltier device was lower than the control garment during the exercise. In particular, the chest skin temperature was $1.5^{\circ}C$ lower with the cooling garment than the control. The maximum temperature difference was $-2.57^{\circ}C$ on the sides of the $1^{st}$ layer. Subjective thermal sensation from wear trials of the Peltier device attached garment was lower than the control garment. Subjects felt more comfortable with the cooling garment in almost all the periods.

Virtual Reality Using X3DOM (X3DOM을 이용한 가상현실)

  • Chheang, Vuthea;Ryu, Ga-Ae;Jeong, Sangkwon;Lee, Gookhwan;Yoo, Kwan-Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.1
    • /
    • pp.165-170
    • /
    • 2017
  • Web 3D technology can be used to simulate the experiments of scientific, medical, engineering and multimedia visualization. On the web environment, 3D virtual reality can be accessed well without strictly on operating system, location and time. Virtual Reality (VR) is used to depict a three-dimensional, computer generated realistic images, sound and other sensations to replicated a real environment or an imaginary setting which can be explored and interacted with by a person. That person is immersed within virtual environment and is able to manipulate objects or perform a series of action. Virtual environment can be created with X3D which is the ISO standard for defining 3D interactive, web-based 3D content and integrating with multimedia. In this paper, we discuss about X3D VR stereo rendering scene and propose new X3D nodes for the HMD VR (head mounted display virtual reality). The proposed nodes are visualized by the web browser X3DOM of X3D.

Analysis of Appearance & Wearing Sensation by Sleeve Cap Height of Jackets for Women in their Twenties (20대 여성재킷의 소매산 높이에 따른 외관과 착용감 분석)

  • Song, Won-Young;Lee, So-Young
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.19 no.4
    • /
    • pp.123-137
    • /
    • 2017
  • The purpose of this study is to suggest sleeve cap height with a satisfying wearing sensation and appearance on jackets for women in their twenties so that high-consumer demand jackets can be produced. Five experimental jackets with sleeve cap heights of [(AH/3)-1cm], [(AH/3)-0.5cm], [AH/3], [(AH/3)+0.5cm] and [(AH/3)+0.8cm] were made for 30 subjects to try on after which the subjects were then surveyed for their assessment of appearance, wearing sensation and preference. On the basis of the results, the optimum height of the sleeve cap has been proposed along with the following contents and results of this research. 1. [AH/3] [(AH/3)+0.8cm] of sleeve cap height was assessed to beof desirable appearance. 2. [AH/3] of sleeve cap height garnered a high opinion in terms of intuitive wearing sensation, while [(AH/3)-1cm] [AH/3] were the heights with overall satisfaction of intuitive and movement wearing sensations. If discomfort in the upper sleeve at 'straight arm' posture can be tolerated, the sleeve cap height can be set to [(AH/3)-1cm]~[(AH/3)+0.5cm]. 3. [AH/3] and [(AH/3)+0.5cm] were found to have a high preference among wearers, which indicated that the women in their twenties prefer a slim type of sleeve, putting appearance above wearing sensation. Consequently, [AH/3] is desirable when appearance, wearing sensation and preference are considered, [(AH/3)+0.5cm] is fit for business uniform for static duties or formal dress focused on aesthetic impression and [(AH/3)-1cm]~[AH/3] are desirable for work clothes when considering active duties.

  • PDF