• Title/Summary/Keyword: Self-testing

Search Result 840, Processing Time 0.027 seconds

Knowledge and Attitudes of Bangkok Metropolitan Women towards HPV and Self-Sampled HPV Testing

  • Kittisiam, Thannaporn;Tangjitgamol, Siriwan;Chaowawanit, Woraphot;Khunnarong, Jakkapan;Srijaipracharoen, Sunamchok;Thavaramara, Thaowalai;Pataradool, Kamol
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2445-2451
    • /
    • 2016
  • Background: To evaluate knowledge of Bangkok women regarding HPV and self-sampled HPV testing, and their attitudes towards testing. Materials and Methods: Thai women who had lived in Bangkok for more than 5 years, aged 25-to-65 years old, were invited to join the study. Participating women were asked to a complete self-questionnaire (Thai language), with literate assistance as needed. The questionnaire was divided into 3 parts: (I) demographic data, (II) knowledge and (III) attitudes towards self-sampled HPV testing. Before proceeding to Part III of the questionnaire, a 15-minute educational video of self-sampled HPV testing was presented to all participants. Results: Among 2,810 women who answered the questionnaires, 33.7% reported that they did not know about HPV. The characteristic features of these women were older age (> 50 years), lower income (< 600 USD/month), unemployed status, and non-attendees at cervical cancer screening. Only small numbers of women (4.6%) responded that they had heard about self-sampled HPV testing. After having information, 59.6% would not use the self-sampled HPV testing as a method of cervical cancer screening (non-acceptance). Factors significantly associated with the non-acceptance were older age, lower income, having no knowledge about HPV or self-collected HPV testing, a perception that the testing was unreliable and a concern that they might not be able to perform it correctly. Conclusions: Nearly half and almost all Bangkok women did not know about HPV and self-sampled HPV testing, respectively. Approximately 60% of Bangkok women refused to do the self-sampled HPV testing. Significant negative attitudes were concerns that the testing would be unreliable and a lack of confidence to perform the procedure correctly. Education about HPV and self-sampled HPV testing, ease of the procedure, or the testing models may increase rate of acceptability or positive attitudes.

Setting Priority Criteria for Classification of Self-Testing In Vitro Diagnostic Medical Devices Using Analytic Hierarchy Process Technique (Analytic Hierarchy Process 기법을 활용한 개인용 체외진단의료기기 분류기준에 대한 우선순위 연구)

  • Seol-Ihn Kim;Do-Yun Pyeon;Yong-Ik Jeong;Jahyun Cho;Gaya Noh;Green Bae;Hye-Young Kwon
    • Health Policy and Management
    • /
    • v.33 no.2
    • /
    • pp.173-184
    • /
    • 2023
  • Background: The coronavirus disease 2019 pandemic has been challenging the healthcare service, i.e., the vitalization of the point of care accompanying self-testing in vitro diagnostic medical devices (IVDs). This study aims to suggest priority criteria to classify self-testing IVDs using the analytic hierarchy process technique. Methods: Two dimensions of the characteristics embedded in the IVDs and the diseases to be diagnosed with self-testing IVDs were parallelly considered and independently investigated. In addition, three expert panels consisting of laboratory medical doctors (n=11), clinicians (n=10), and citizens (n=11) who have an interest in the selection of self-testing IVDs were asked to answer to questionnaires. Priorities were derived and compared among each expert panel. Results: First of all, ease of specimen collection (0.241), urgency of the situation (0.224), and simplicity of device operation (0.214) were found to be the most important criteria in light of the functional characteristics of self-testing IVDs. Medical doctors valued the ease of specimen collection, but the citizen's panel valued self-management of the disease more. Second, considering the characteristics of the diseases, the priority criteria were shown in the order of prevalence of diseases (0.421), fatality of disease (0.378), and disease with stigma (0.201). Third, medical doctors responded that self-testing IVDs were more than twice as suitable for non-communicable diseases as compared to communicable diseases (0.688 vs. 0.312), but the citizen's group responded that self-testing IVDs were slightly more suitable for infectious diseases (0.511 vs. 0.489). Conclusion: Our findings suggested that self-testing IVDs could be primarily classified as the items for diagnosis of non-communicable diseases for the purpose of self-management with easy specimen collection and simple operation of devices, taking into account the urgency of the situation as well as prevalence and fatality of the disease.

A Study for Design and Application of Self-Testing Comparator (자체시험 (Self-Testing) 특성 비교기(Comparator)설계와 응용에 관한 연구)

  • 정용운;김현기;양성현;이기서
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.408-418
    • /
    • 1998
  • This paper presents the implementation of comparator which is self-testing with respect to the faults caused by any single physical defect likely to occur in NMOS and CMOS integrated circuit. The goal is to use it for the fault-tolerant system. First, a new fault model for PLA(Programmable Logic Array) is presented. This model reflects several physical defects in VLSI circuits. It focuses on the designs based on PLA because VLSI chips are far too complex to allow detailed analysis of all the possible physical defects that can occur and of the effects on the operation of the circuit. Second, this paper shows that these design, which has been implemented with 2 level AND-ORor NOR-NOR circuit, are optimal in term of size. And it also presents a formal proof that a comparator implemented using NOR-NOR PLA, based on these design, is sol f-testing with respect to most single faults in the presented fault model. Finally, it discusses the application of the self-testing comparator as a building block for the implementation of the fault-tolerant system.

  • PDF

A compare analysis on the counseling of testing and interview for problem of adolescent (청소년의 문제 조력을 위한 검사상담과 면담상담 비교)

  • Park, Sung-Mi
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.18 no.3
    • /
    • pp.272-282
    • /
    • 2006
  • The purpose of this study was a compare analysis on the counseling of testing and interview for problem of adolescent. The subjects were 20 adolescents who had randomly assigned to an experimental group(10) and a control group(10). To obtain the data, relation of counseling, awareness of self, motivation of self, identity of career questionaries were used. To analyze data, ANCOVA, MANOVA were executed. The results were follows. First, the counseling of testing affected significantly on improvement of experimental group's awareness of self, motivation of self. Second, the counseling of testing affected significantly on improvement of experimental group's identity of career.

Self-adaptive testing to determine sample size for flash memory solutions

  • Byun, Chul-Hoon;Jeon, Chang-Kyun;Lee, Taek;In, Hoh Peter
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.6
    • /
    • pp.2139-2151
    • /
    • 2014
  • Embedded system testing, especially long-term reliability testing, of flash memory solutions such as embedded multi-media card, secure digital card and solid-state drive involves strategic decision making related to test sample size to achieve high test coverage. The test sample size is the number of flash memory devices used in a test. Earlier, there were physical limitations on the testing period and the number of test devices that could be used. Hence, decisions regarding the sample size depended on the experience of human testers owing to the absence of well-defined standards. Moreover, a lack of understanding of the importance of the sample size resulted in field defects due to unexpected user scenarios. In worst cases, users finally detected these defects after several years. In this paper, we propose that a large number of potential field defects can be detected if an adequately large test sample size is used to target weak features during long-term reliability testing of flash memory solutions. In general, a larger test sample size yields better results. However, owing to the limited availability of physical resources, there is a limit on the test sample size that can be used. In this paper, we address this problem by proposing a self-adaptive reliability testing scheme to decide the sample size for effective long-term reliability testing.

Computer Input Frequency of Blood Glucose Self Testing in Type 2 Diabetic Patients (유.무선 인터넷을 이용한 제2형 당뇨형환자 가정에서의 혈당 입력)

  • Kim, Hee-Seung
    • Research in Community and Public Health Nursing
    • /
    • v.15 no.1
    • /
    • pp.29-35
    • /
    • 2004
  • Purpose: The purpose of this study was to investigate the computer input frequency of blood glucose self testing in type2 diabetic patients, for three months. Method: 39 participants were recruited from the endocrinology outpatient department of a tertiary care hospital in an urban city. The computer input frequencies were measured by patients' log in and input of http://www.biodang.com. Glycosylated haemoglobin was determined by a high performance liquid chromatography technique and fasting blood glucose was analyzed by the glucose oxidase method. Diabetes knowledge was measured by a 19 item diabetes knowledge test. Results: The computer input frequency of before breakfast blood glucose was 33.5 for three months. The total blood glucose input frequency tended to be lower in female, aged patients, middle school graduates, those who have no spouse and job, those who have no insulin treatment, obese subjects, and hyperglycemia patients, than in their counterparts. The diabetic knowledge was positively correlated with the computer input frequency of blood glucose self testing. Conclusion: An educational program should be developed to increase the computer input frequency of blood glucose self testing in type2 diabetic patients.

  • PDF

Blockchain and Cryptocurrency Distributed Testing Methods

  • Lee, Taegyu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Recently, a large number of cryptocurrencies and block chains have been continuously released. However, these cryptocurrencies and block chains are open to users without authorized verification and testing procedures, causing various reliability problems. Existing cryptocurrencies and blockchain test methods build a blockchain Testnet for a certain period of time by the developer without external verification by a third party, and after repeatedly self-testing and self-operating processes, commercialization is in progress by switching to the Mainnet. This self-verification method does not guarantee objectivity and publicness, and high reliability of customers cannot be realized. This study proposes a cryptocurrency and blockchain test interface and test control system as a third-party open test method.

Nucleic acid-based molecular diagnostic testing of SARS-CoV-2 using self-collected saliva specimens

  • Hwang, Eurim C.;Kim, Jeong Hee
    • International Journal of Oral Biology
    • /
    • v.46 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Since the outbreak of coronavirus disease 2019 (COVID-2019), the infection has spread worldwide due to the highly contagious nature of severe acute syndrome coronavirus (SARS-CoV-2). To manage SARS-CoV-2, the development of diagnostic assays that can quickly and accurately identify the disease in patients is necessary. Currently, nucleic acid-based testing and serology-based testing are two widely used approaches. Of these, nucleic acid-based testing with quantitative reverse transcription-PCR (RT-qPCR) using nasopharyngeal (NP) and/or oropharyngeal (OP) swabs is considered to be the gold standard. Recently, the use of saliva samples has been considered as an alternative method of sample collection. Compared to the NP and OP swab methods, saliva specimens have several advantages. Saliva specimens are easier to collect. Self-collection of saliva specimens can reduce the risk of infection to healthcare providers and reduce sample collection time and cost. Until recently, the sensitivity and accuracy of the data obtained using saliva specimens for SARS-CoV-2 detection was controversial. However, recent clinical research has found that sensitive and reliable data can be obtained from saliva specimens using RT-qPCR, with approximately 81% to 95% correspondence with the data obtained from NP and OP swabs. These data suggest that self-collected saliva is an alternative option for the diagnosis of COVID-19.

Acceptability of Self-Sampling HPV Testing Among Thai Women for Cervical Cancer Screening

  • Oranratanaphan, Shina;Termrungruanglert, Wichai;Khemapech, Nipon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7437-7441
    • /
    • 2014
  • Background: Acceptability of self-sampling HPV testing is confirmed worldwide. However, some cultural differences may affect this question. Therefore, this study was conducted to evaluate the acceptability of self-sampling HPV testing in Thai women. Materials and Methods: One hundred women aged 30-65 years with an intact cervix were included in this study. The participants were asked to do the Pap test by physicians and then brush type self-sampling instruments were assigned for self-collection and finally completed a questionnaire for acceptability evaluation. The questionnaire contains 2 parts. Part one covered general information of the participants and part two is the acceptability questions. Results: Mean age was 40.6 years. The incidence of high risk HPV detection in this study was 16%. The most common reason for doing Pap smear was for annual checkup. On the topic of ease of use, 85 % of the subjects agreed. Most of the participants (82%) reported that they felt less pain. However, reliability of the result was not satisfactory because 37% of the participants hesitated to rely on the results of the test. According to the price, if the price is less than 1,000 Baht (32.59 Baht = 1USD), 82% of the subjects would use it for their next screening. Conclusions: The acceptability of self-sampling device in this study is quite good but the reliability of the test was questioned by some of the participants. Moreover, the price of the test in Thailand may also influence the acceptability of the test.