• Title/Summary/Keyword: Self-radiation

Search Result 336, Processing Time 0.026 seconds

Factors Affecting Radiation Protection Behaviors among Operating Room Nurses (수술실 간호사의 방사선 방어행위의 영향 요인)

  • Kim, Jin;Kim, Jin Sun;Kim, Hyunlye
    • Korean Journal of Adult Nursing
    • /
    • v.28 no.6
    • /
    • pp.680-690
    • /
    • 2016
  • Purpose: This study was designed to identify knowledge, attitude, environment, and self-efficacy among perioperative nurses in terms of radiation protection and to describe those factors affecting radiation protection behaviors. Methods: The sample was comprised of 128 perioperative nurses who agreed to participate in this descriptive study. Data were collected from a self-administered questionnaire and were analyzed using the t-test, analysis of variance, Mann-whitney U test, Kruskal-Wallis test, Pearson's correlation, and multiple regression analyses. Results: Radiation protection behaviors were significantly different by participant's gender, length of career as a perioperative nurse, educational level and prior experience with radiation protection education. Radiation protection behaviors were significantly correlated with radiation protection environment and self-efficacy in terms of radiation protection behaviors. In the multiple linear regression models, radiation protection environment and self-efficacy on radiation protection behaviors were statistically significant predictors of radiation protection behaviors, which accounted for 50.3% of variance in dependent variable. Conclusion: This study concluded that radiation protective environment in operating room is important to promote radiation protective behaviors and radiation safety management program to enhance self-efficacy is highly recommended.

An Investigation of Self-Radiation Impedance of a Square Piston using an Integral Equation in the Rigid Infinite Baffle (적분식을 이용한 무한배플 사각형 진동체의 자기방사 임피던스 연구)

  • Lee, Jong-Kil;Seo, In-Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.58-62
    • /
    • 1995
  • Integral equations of self-radiation impedance of a rectangular piston in a rigid infinite baffle are derived using by polar coordinate. The self-radiation impedance is separated by two parts ; self-radiation resistance and self-radiation reactance. Derived integral equations are simulated by numerical method. Based on the numerical results, self-radiation impedance can be obtained in the low and high frequency ranges without any limited conditions.

  • PDF

Calculation of Self-radiation Impedance for a Rectangular Transducer (장방형 트랜스듀서의 자기방사 임피던스 계산)

  • 이기욱;김무준;하강열;김천덕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.7
    • /
    • pp.85-89
    • /
    • 2000
  • In this paper, by extending the previously developed self- and mutual-radiation impedance calculation method for a regular-square vibrating surface by using numerical series, we proposed a method to obtain the self-radiation impedance of a rectangular transducer with an arbitrary integer ratio of the length to width. The proposed method exhibits high accuracy and a short computation time. After investigating the accuracy and computation time as the number of elements changes, we have calculated the self-radiation impedance of several rectangular transducers, and compared the results with those in the literature.

  • PDF

Comparing with self-efficacy and knowledge, attitudes about radiation safety management of dental hygienists and students at department of dental hygiene (치과위생사와 치위생과 학생의 자기효능감과 방사선안전관리 지식 및 태도에 대한 비교)

  • Yoon, Jung-Ae;Yoon, Young-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.5
    • /
    • pp.729-739
    • /
    • 2011
  • Objectives : It is important to catch individual characteristics by measuring the level of self-efficacy, radiation safety knowledge, attitudes to increase behavior levels in the radiation safety management(RSM) and we consider this should be applied to the professional program development to improve RSM activities of dental hygienist and students at department of dental hygiene. Methods : This study mentioned mainly self-efficacy, radiation safety knowledge, attitudes for dental hygienists and the second & third year students at department of dental hygiene in Pusan area to provide the correct information associated with the use of radiation and to be aid in the development program to increase behavior levels in the RSM in dental care institutions and schools in the future and performed a survey 8 May to 7 Juiy, 2011. The survey results were as follows Results : 1. The results of self-efficacy is $3.53{\pm}0.42$ points for the dental hygienist and $3.32{\pm}0.40$ points for students(p<0.001). 2. According to the knowledge level of RSM, the result is $11.7{\pm}3.12$ points for the dental hygienist and $9.56{\pm}2.72$ points for students(p<0.001). 3. According to the knowledge level of RSM, the result is $4.40{\pm}0.49$ points for the dental hygienist and $4.22{\pm}0.56$ points for students(p<0.001). 4. According to relationship among self-efficacy, radiation safety knowledge and attitudes, the higher the score for knowledge of RSM was, the higher the score for self-efficacy was. The higher the score for attitudes was, the higher the score for self-efficacy and knowledge was(p<0.01). 5. The factors to affect attitudes about RSM were self-efficacy, knowledge(p<0.01).

A Study on the Prediction of Self-absorption in Opposed Flames Using WSGGM-Based Spectral Model (파장별 회체가스중합모델을 이용한 대향류 화염에서의 복사 흡수 예측에 관한 연구)

  • Kim, Uk-Jung;Viskanta, Raymond;Gore, Jay Prabhakar;Zhu, Xuelei
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.600-609
    • /
    • 2001
  • WSGGM based low-resolution spectral model for calculating radiation transfer in combustion gases is applied to estimate self-absorption of radiation energy in one-dimensional opposed flow flames. Development of such a model is necessary in order to enable detailed chemistry-radiation interaction calculations including self-absorption. Database of band model parameters which can be applied to various one-dimensional opposed flow diffusion and partially premixed flames is created. For the validation of the model and database, low resolution spectral intensities at fuel exit side are calculated and compared with the results of a narrow band model with those based on the Curtis-Godson approximation. Good agreements have been found between them. The resulting radiation model is coupled to the OPPDIF code to calculate the self-absorption of radiant energy and compared with the results of an optically thin calculation and the results of a discrete ordinates method in conjunction with the statistical narrow band model. Significant self-absorption of radiation is found for the flames considered here particularly for the fuel side of the reacting zone. However, the self-absorption does not have significant effects on the flame structure in this case. Even in the case of the low velocity diffusion flame and the partially premixed flame of low equivalence ratio, the effects of self-absorption of radiation on the flame temperature and production of minor species are not significant.

Measurement of the self-radiation impedance of an ultrasonic transducer with a square vibrating surface (정방형 방사면을 갖는 초음파 진동자의 자기방사임피던스 측정)

  • Kim, Jungsoon;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.2
    • /
    • pp.108-114
    • /
    • 2017
  • We have experimentally analyzed the self-radiation impedance of an ultrasonic transducer with a square radiation surface that is used as a vibrator in underwater ultrasonic detection systems. The radiation reactance and the radiation resistance were measured in the range from 1 to 3 of ka that is the product of a wave number and a length of the edge of the square vibrator. By comparing the measured results with those of theoretical calculation of the radiation impedance using a series, we confirmed the validity of the experimental method and experimentally confirmed the variation trend in the radiation impedance of the square radiation surface.

Calculation of Radiation Impedance for Piston Sources on a Spherical Baffle (구형 배플상의 피스톤 음원에 대한 방사임피던스 계산)

  • 박순종;김무준;김천덕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.54-60
    • /
    • 2003
  • The characteristics of radiation impedance for piston source on a spherical baffle are analyzed by algorithms which consists of Finite Element Method (FEM) and Hybrid type Infinite Element Method (HIEM). The results of self-radiation impedance for radiation angle and mutual radiation impedance between piston sources coincided with other reports on the spherical rigid baffle. For the spherical non-rigid baffles, the variations of self-radiation impedance and mutual-radiation impedance are identified. Therefore, these results can be applied to design and radiation characteristics analysis of acoustic transducers.

Relationship between Knowledge, Attitude, Behavior, and Self-Efficacy on the Radiation Safety Management of Radiation Workers in Medical Institutions (의료기관 방사선종사자의 방사선안전관리에 대한 지식, 태도 및 행위와 자기효능감 간의 관련성)

  • Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • Radiation safety managements in medical institutions are needed to protect certain radiation damages as a part of National Coalition. This study investigates the characteristics of self-efficacy that become the major factor on the knowledge, attitude, and behavior on the radiation safety management of radiation workers as an approach of educational aspects and analyzes the relationship between such factors to provide basic materials for improving the activity level of radiation safety managements. In order to implement the goal or this study, a survey was performed for 1,200 workers who were engaged in radiation treatments in medical centers, such as general hospital, university hospital, private hospital, and public health center for 42 days from July 23,2006. Then, the results of the analysis can be summarized as follows: 1. Average scores on knowledge, attitude, and behavior in the radiation safety management were presented as $75.76{\pm}11.20$, $90.55{\pm}8.59$, $80.58{\pm}11.70$, respectively. Also, the average score of self-efficacy was recorded as $73.55{\pm}9.82$. 2. Knowledge levels in the radiation safety management showed significant differences according to the sex, age, marriage, education, and experience. Also, males of married, older, highly educated, and largely experienced represented high knowledge levels. Attitude levels in the radiation safety management showed certain significant differences according to the type of medical centers in which private hospitals showed a relatively low level compared to that of high levels in university hospitals. Behavior levels in the radiation safety management also represented significant differences according to the age, marriage, education, experience, and types of medical centers. Factors in married, general hospital, older, highly educated, and largely experienced showed high behavior levels. In addition, the self-efficacy showed certain differences according to the marriage and types of medical centers. Factors in married and general hospital demonstrated high self-efficacy levels. 3. Relationship between knowledge, attitude, behavior, and self-efficacy on the radiation safety management showed statistical differences according to the relationship between the knowledge and the attitude, the knowledge and the behavior, the attitude and the behavior, the attitude and the self-efficacy, and the behavior and the self-efficacy. The relationship between the behavior and the self-efficacy was represented as r = 0.482, which was the strongest relationship in such factors. Also, the knowledge and self-efficacy didn't show certain relationships.

A Survey about Self-Efficacy and Consciousness on the Use of Radiation, Knowledge and Attitude for Student at Department of Dental Hygiene (부산지역 치위생과 학생의 자기효능감과 방사선 이용에 대한 의식도, 지식 및 태도에 관한 조사연구)

  • Jung, Young-Hee;Lim, Hyun-Ju
    • The Korean Journal of Health Service Management
    • /
    • v.6 no.2
    • /
    • pp.81-89
    • /
    • 2012
  • This research, which was conducted for student at department of dental hygiene, intended to measure the level of self-efficacy and consciousness on the use of radiation, knowledge and attitude on radiation safety management and got the following conclusions. This study was performed from May 8 to July 7, 2011 for 326 students who study at Department of Dental Hygiene of a three-year course in Busan areas. The result of as follows; 1. As a result of comparing the average of a sense of self-efficacy according to the characteristics of those surveyed, a statistically significant difference(p<0.01)(p<0.001) was found according to grade point average, subjective health condition. 2. As a result of comparing the average level of consciousness about radiation use according to the characteristics of those surveyed, a statistically meaningful difference(p<0.05)(p<0.01) was found according to grade, grade point average. 3. As a result of conducting a correlation analysis among self-efficacy, consciousness on the use of radiation, knowledge and attitude on RSM, the correlation of self-efficacy and consciousness, knowledge, and attitude was r=0.108, 0.203, 0.231 respectively, all of which was a plus correlation(p<0.01). we believe that a variety of programs should be offered to be capable of enhancing knowledge and attitude on RSM, self-efficacy.

Self-Radiation Impedance of rectangular Acoustic Sensor Without Baffle (배플이 없는 사각형 음향센서의 자기방사 임피던스)

  • Lee, Jong-Kil;Seo, In-Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.82-88
    • /
    • 1995
  • Conductance and susceptance of the self-radiation impedance in a rectangular acoustic sensor without baffle are measured experimentally. Finite polyurethane window is mounted at the end of the acoustic sensor. The sensor radiation impedance is cauculated using the equivalent electric circuit. Using the Levine's integral equations of a rectangular piston mounted to the rigid infinite baffle, radiation resistance and reactance were simulated numerically. Numerical and experimental results are compared to each other.

  • PDF