• Title/Summary/Keyword: Self-Storage facilities

Search Result 31, Processing Time 0.024 seconds

A Noise Prediction of Floating, Production, Storage and Offloading(FPSO) (부유식 석유생산.저장.하역선박의 소음해석)

  • Kim, Young-Hyun;Kim, Dong-Hae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.307-310
    • /
    • 2000
  • Recently, the demand for the Floating, Production Storage, and Offloading facility(FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. The basic characteristics of a 343,000 DWT class FPSO which is being built in Hyundai Heavy Industries and shall be installed in offshore Angola, is almost same as that of oil carriers. However, she do not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise source contributing to the cabin noise of the accommodation, are classified into the machine in the engine room and the deckhouse, HVAC system, and the topside equipments. In general, the noise regulation for the offshore structure is much severer than that of the common commercial ships and the maximum acceptable sound pressure level of cabins is specified in 45dB(A). This paper describes the procedure of noise analysis along with its results. Noise analysis has been carried out for the case of emergency diesel generator running condition and the case of normal production condition and the results has been compared with the measurement results of the first case. Based on the results, proper countermeasures to reduce excessive noise level has been applied considering the characteristics of sources and receiver spaces and can be satisfied the specifications at all spaces.

  • PDF

Field Assessment of Food Safety Management at Preschool Foodservice Establishments (영유아 급식소 위생관리 수행도 현장평가)

  • Bae, Hyun-Joo;Lee, Hye-Yeon;Ryu, Kyung
    • Korean journal of food and cookery science
    • /
    • v.25 no.3
    • /
    • pp.283-296
    • /
    • 2009
  • This study examined food safety management at preschool establishments in Daegu and Gyeongbuk province, to provide data that can be used for food safety improvements. Field assessments of 60 foodservice establishments were executed from July to October, 2007. Statistical analyses of the data were conducted using the SPSS package program (version 14.0 for windows). The results are summarized as follows: 93.3% of the preschool foodservices were self-operated, and 24.1% of the child care centers and 96.7% of the kindergartens had employed dietitians. According to the averaged food safety evaluation scores the kindergartens (80.73) had a significantly higher score than the child care centers (50.37), and the public centers (85.00) had a significantly higher score than the private centers (54.29). While the average score of facilities that employed dietitian (73.58) was significantly higher than that of facilities that did not employ a dietitian (52.65). In addition, the average score of facilities that served meals in a dining room (80.83) was significantly higher than that of facilities that served meals in a classroom (59.33). The highest scoring food safety items included verifying employee health inspection reports (1.87), utilizing non-municipal water and routinely cleaning and well-maintaining the water storage tank (1.85), and disposing small amounts of leftovers in a vat after serving (1.83). In contrast, the lowest scores were for physical separation of clean areas and unclean areas to prevent cross-contamination (0.52), and physical separation between staff and food material entry areas (0.62). In conclusion, the preschool foodservice evaluated in this study required improvements in food safety management, and many of the child care centers were in need of immediate attention. To improve food safety at these establishments, administrators should implement prerequisite food safety programs.

A Seismic Stability Design by the KEPIC Code of Main Pipe in Reactor Containment Building of a Nuclear Power Plant (원자력 발전소 RCB 내 중요배관의 KEPIC 코드에 의한 내진 안전성 설계)

  • Yi, Hyeong-Bok;Lee, Jin-Kyu;Kang, Tae-In
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.2
    • /
    • pp.233-238
    • /
    • 2011
  • In piping design of nuclear power plant facilities, the load stress according to self-weight is important for design values in test run(shutdown and starting). But sometimes it needs more studies, such as seismic analysis of an earthquake of power plant area and fatigue life and stress of thermal expansion and anchor displacement in operating run. In this paper, seismic evaluations were performed to nuclear piping system of Shin-Kori NO. 3&4 being built in Pusan lately. Results of seismic analysis are evaluated on basis of KEPIC MN code. The structural integrity on RCB piping system was proved.

A Noise Characteristics and Countermeasures of FPSO Topside (FPSO Topside의 소음특성 파악 및 저감대책)

  • Kim, Dong-Hae;Kim, Sung-Hoon;Chung, Kun-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.73-76
    • /
    • 2005
  • Recently, the demand for the Floating, Production, Storage, and Offloading facility (FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. FPSO vessel dose not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise sources such as gas turbines, compressors, and pumps, are located on top of the hull (Topside area). In general, the noise regulation for the offshore structure is severer than that of the cargo ship and acceptable noise limit of cabin is specified as 45 dB(A). This paper describes the noise characteristics and the countermeasures for FPSO Topside area through investigation of noise analysis and site measurement results. Proper countermeasures, considering the characteristics of sources and receiver spaces, were applied from the noise prediction and various measurement results. Finally, this ship was successfully delivered with excellent noise properties.

  • PDF

Present Status of Soil Contamination Facilities (특정토양오염관리대상시설의 실태에 관한 고찰)

  • Kim, Ki-Ho;Park, Jae-Soo;Kim, Hae-Keum;Choi, Sang-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.287-292
    • /
    • 2012
  • This study was to build the database by collecting the results of legal leak test and self-test conducted by the owners of soil contamination facilities at soil-related specialized agency to grip objective status on soil contamination facilities and evaluate classification results. The results of the study showed that the unsuitable rate of business unit is 53.6%, the business with leak that could cause actual pollution is 25.7%, the unsuitable rate of the voluntary self-test is 57.3%, that of the compulsory inspection is 17.2% depending on the test motivation, that of the direct-test is 58.9%, and that of the indirect-test is 22.5% depending on the test methods. There was a significant difference between the test motivation conducted and the test methods applied. From the results of the unsuitable reasons obtained we could assume that about 20% of the whole target tanks became potential sources with natural defects occurred when such tanks were made, and 2.2% of the whole tankers examined that persisting period was caused by progressing corrosion below the minimum thickness.

Consequence Modeling Methodology for Prediction of Hazard Distance for Two-phase Flow Release from the Pressurized Chlorine Saturated Liquid Storage Tank (가압 염소포화액체 저장탱크의 2상 흐름 누출에 대한 유해위험거리의 예측을 위한 결과영향 모델링 방법론)

  • Song D. M.;Park Y. S.;Park J. K.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.7-17
    • /
    • 1998
  • This study is to develop the consequence modeling methodology for quantitative prediction of the hazard distance(or toxic buffer distance) for two-phase flow continuous releases from the pressurized chlorine saturated liquid storage tank of the chemical plant facilities. The source term modeling was peformed by the refined analysis method based on USEPA's guideline and SuperChems model self-calculation, respectively. The hazard distance was predicted for STEL, IDLH and ERPGs(ERPG-2 and ERPG-3) concentrations being used as the toxic regultaion concentration in hazard estimation. To use as hazard estimation guideline for the establishment of the emergency response planning, the effects of source characteristics and meteorological vaiations on the hazard distance was especially considered for ERPG-2 concentration.

  • PDF

Diabetes Management and Hypoglycemia in Safety Sensitive Jobs

  • Lee, See-Muah;Koh, David;Chui, Winnie Kl;Sum, Chee-Fang
    • Safety and Health at Work
    • /
    • v.2 no.1
    • /
    • pp.9-16
    • /
    • 2011
  • The majority of people diagnosed with diabetes mellitus are in the working age group in developing countries. The interrelationship of diabetes and work, that is, diabetes affecting work and work affecting diabetes, becomes an important issue for these people. Therapeutic options for the diabetic worker have been developed, and currently include various insulins, insulin sensitizers and secretagogues, incretin mimetics and enhancers, and alpha glucosidase inhibitors. Hypoglycemia and hypoglycaemic unawareness are important and unwanted treatment side effects. The risk they pose with respect to cognitive impairment can have safety implications. The understanding of the therapeutic options in the management of diabetic workers, blood glucose awareness training, and self-monitoring blood glucose will help to mitigate this risk. Employment decisions must also take into account the extent to which the jobs performed by the worker are safety sensitive. A risk assessment matrix, based on the extent to which a job is considered safety sensitive and based on the severity of the hypoglycaemia, may assist in determining one's fitness to work. Support at the workplace, such as a provision of healthy food options and arrangements for affected workers will be helpful for such workers. Arrangements include permission to carry and consume emergency sugar, flexible meal times, selfmonitoring blood glucose when required, storage/disposal facilities for medicine such as insulin and needles, time off for medical appointments, and structured self-help programs.

The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area - (제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 -)

  • Kang, Youn-Ku;Lim, Tae-Sub
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.

Isotopic Fissile Assay of Spent Fuel in a Lead Slowing-Down Spectrometer System

  • Lee, Yongdeok;Jeon, Juyoung;Park, Changje
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.549-555
    • /
    • 2017
  • A lead slowing-down spectrometer (LSDS) system is under development to analyze isotopic fissile content that is applicable to spent fuel and recycled material. The source neutron mechanism for efficient and effective generation was also determined. The source neutron interacts with a lead medium and produces continuous neutron energy, and this energy generates dominant fission at each fissile, below the unresolved resonance region. From the relationship between the induced fissile fission and the fast fission neutron detection, a mathematical assay model for an isotopic fissile material was set up. The assay model can be expanded for all fissile materials. The correction factor for self-shielding was defined in the fuel assay area. The corrected fission signature provides well-defined fission properties with an increase in the fissile content. The assay procedure was also established. The assay energy range is very important to take into account the prominent fission structure of each fissile material. Fission detection occurred according to the change of the Pu239 weight percent (wt%), but the content of U235 and Pu241 was fixed at 1 wt%. The assay result was obtained with 2~3% uncertainty for Pu239, depending on the amount of Pu239 in the fuel. The results show that LSDS is a very powerful technique to assay the isotopic fissile content in spent fuel and recycled materials for the reuse of fissile materials. Additionally, a LSDS is applicable during the optimum design of spent fuel storage facilities and their management. The isotopic fissile content assay will increase the transparency and credibility of spent fuel storage.

Oil Absorption Effects of Organic Porous Materials (유기 다공성 소재의 흡유 효과)

  • Kang, Young-Goo;Han, Sang-Bum
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.86-91
    • /
    • 2006
  • Oil spills caused by the accidents have been occurred from house and factory waste, grounded tanker, the rupture of storage tank and oil pipelines, the deterioration of various industrial facilities, etc. Many oil spills result in contamination of shorelines and workplace. Fire and explosion may happen from these spills. There are several technologies used for clean-up application, which include use of oil dispersing agents, absorbents, solidifiers, booms and skimmers by physical, chemical, and biological methods. Methods for oil spill clean-up operation are classified into the absorption type, gel type and self-swelling type. Porous materials with oil absorptive properties are classified into micropore, mesopore, and macropore depending on their pore sizes. Recently, new porous materials with smaller size have been developed, but the selective oil absorption in water-in-oil interface demonstrates the macro pore size. In this study oil absorption effects were evaluated using the organic porous materials with a complex function of gel type and swelling type. Samples were subjected to analysis by FT-IR spectroscopy and were characterized in terms of gel formation and morphologies. Oil sorption capacity, pressure retention force and gel strength were also measured. From these results, the physicochemical reactivity before and after gelation was verified and the industrial applications of clean-up operation were suggested.