• Title/Summary/Keyword: Self-Extinguishing

Search Result 22, Processing Time 0.021 seconds

Mechanical Behaviors of Electrospun Non-woven of PVC/PU blend (전기방사된 PVC/PU의 기계적 거동)

  • Lee, Bong-Seok;Lee, Keun-Hyung;Kim, Hak-Yong;Pyo, Soo-ho;Park, Sun-Woong
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.269-270
    • /
    • 2003
  • Thermoplastic polyurethane is a engineering plastic with elasticity, abrasion resistance and good resistance to oil, grease and many solvents. Characteristics of poly(vinyl chloride) (PVC) are good general chemical resistance, excellent weatherablility, good insulate. properties, and self-extinguishing or flame resistance, etc. So it is used in widespread industrial fields[2]. (omitted)

  • PDF

A Study on Fire Prevention Requirements and Tests for Small Aircraft (소형항공기의 화재방지 요건 및 시험에 관한 연구)

  • Yoo, Seung-Woo;Jin, Young-Kwon
    • Journal of Aerospace System Engineering
    • /
    • v.5 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • The goal of fire prevention research is to eliminate fires as a cause of fatal accidents and there are two main areas of research. One is to prevent flame propagation during in-flight and it addresses fire hazards. The other is to minimize the possibility of flame penetration or fuselage burn-through and it aims toward post-crash survival include crash protection, emergency evacuation and post-evacuation survival. Civil aviation authorities world-wide are trying to identify threats and measure performance for fire prevention. The results of research are standardized and given as general directions of test methods. This paper has prepared to study and present the means of compliance to the fire prevention requirements and applicable test methods.

Quaternary Ammonium-Based Room Temperature Ionic Liquids as Components of Carbonate Electrolytes for Li-ion Batteries: Electrochemical Performance and Thermal Properties

  • Chernyshov, Denis V.;Shin, Woo Cheol
    • Journal of Electrochemical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.95-104
    • /
    • 2014
  • Electrochemical performance of Li-ion cells with $LiMn_2O_4$ cathodes and graphite anodes with carbonates electrolytes containing quaternary ammonium-based room temperature ionic liquids (ILs) is investigated. Eight different ILs based on tetraalkylammonium, pyrrolidinium or piperidinium cations paired with bis(trifluoromethylsulfonyl)imide or tris(pentafluoroethyl)trifluorophosphate anions are examined in combination with dimethyl carbonate as a main solvent and fluoroethylene carbonate as a solid electrolyte interface forming agent. It is shown that cycling properties of the cells are strongly affected by the content of ILs in the electrolyte mixtures and its increase corresponds to lower discharge capacity retention. Since viscosity and conductivity of ILs are of a great importance for the electrolytes formulation, some kind of combined parameter should be used for the assessment of IL applicability and calculated values of Walden products for neat ILs represent one of the possible options. Besides, positive effect of ILs on reduction of flammability and enhancement of thermal stability of electrolytes in contact with charged electrodes have been demonstrated by means of self-extinguishing time test and differential scanning calorimetry respectively.

Study on Properties of Epoxy Resin Compositions Containing Novolac Derivatives (바이페닐 유도체를 도입한 에폭시 수지 조성물의 특성에 관한 연구)

  • Choi, Su Jung;Kim, Young Chul
    • Journal of Adhesion and Interface
    • /
    • v.12 no.4
    • /
    • pp.138-143
    • /
    • 2011
  • Recently epoxy resin compositions having backbone of novolac derivatives with biphenylene compounds have been used as materials of eco-freindly EMC (Epoxy Molding Compound), because the cured epoxy resin compositions show the self-extinguishing without flame retardant additives. In this study, epoxy resin compositions were prepared and cured using novolac derivateves with biphenylene. Their propeties - structures of phenol derivatives and reactivity, thermal expansion, modulus, and thermal degradation - were obtained by DSC, DMA, TMA, TGA method. When both epoxy resin and hardenr had the biphenyl novolac structure, epoxy resin compositions showed low thermal expansion, good mechanical property, and combustion retardation.

Preparation of melamine-grafted graphene oxide and evaluation of its efficacy as a flame retardant additive for polypropylene

  • Monji, Parisa;Jahanmardi, Reza;Mehranpour, Milad
    • Carbon letters
    • /
    • v.27
    • /
    • pp.81-89
    • /
    • 2018
  • The present study aimed to prepare a novel efficient flame retardant additive for polypropylene. The new flame retardant was prepared by chemical grafting of melamine to graphene oxide with the aid of thionyl chloride. Fourier-transform infrared spectroscopy and thermogravimetric analysis proved that melamine had been successfully grafted to the graphene oxide. The modified graphene oxide was incorporated into polypropylene via solution mixing followed by anti-solvent precipitatio. Homogeneous distribution as well as exfoliation of the nanoplatelets in the polymer matrix was observed using transmission electron microscopy. Thermogravimetric analysis showed a significant improvement in the thermo-oxidative stability of the polymer after incorporating 2 wt% of the modified graphene oxide. The modified graphene oxide also enhanced the limiting oxygen index of the polymer. However, the amount of improvement was not enough for the polymer to be ranked as a self-extinguishing material. Cone calorimetry showed that incorporating 2 wt% of the modified graphene oxide lowered total heat release and the average production rate of carbon monoxide during burning of the polymer by as much as 40 and 35%, respectively. Hence, it was concluded that the new flame retardant can retard burning of the polymer efficiently and profoundly reduce suffocation risk of exposure to burning polymer byproducts.

Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA (SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발)

  • Kim, Si-Kuk;Choi, Su-Gil;Lim, Woo-Sub;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.165-172
    • /
    • 2019
  • This study presents the design and manufacture of a self-contained breathing apparatus SCBA wireless communication module with a multipoint simultaneous full-duplex communication system to enable communication between team members wearing the SCBA system. It is necessary for fire-fighters to wear the SCBA system during extinguishing and rescue work at the fire site. Evaluation of the team communication module confirmed the feasibility of communication over more than 500 m in the test condition based on the line of sight. By implementing the Ad-hoc function, it was confirmed that the communication distance could be extended to 128 m by automatic routing up to 3 hoc. The vertical distance inside the building for successful communication was up to the 5th floor in the open staircase and up to the 3rd floor in the partitioned staircase. Furthermore, the performance testing of the communication module assuming a fire situation, confirmed that five team members correctly recognized the standard abbreviation of fire and wireless communication without a separate PTT key operation. In addition, the flame resistance was verified by exposing the module to a flame at 950 ± 50 ℃ for 5 s and then immediately extinguishing the flame.

A study for a play of improvement in education curriculum for bodyguard related theory (한국 대학의 경호관련학과 이론분야 교육과정의 학문적 정립)

  • Park, Jun-Seok
    • Korean Security Journal
    • /
    • no.5
    • /
    • pp.157-178
    • /
    • 2002
  • The objectives of this study is to analyze the curriculum based on the hypothesis of bodyguarding related department and to research the differences of the amongthree groups of public bodyguarding, private bodyguarding and bodyguarding professors with its significance in order to establish the development of direction in education curriculum for bodyguarding related departments at university level,For this purpose, this study categorized the sample group into three kind and surveyed them, Those are public bodyguarding members, private bodyguarding member, and the professors and 121 samples were selected in those three with the help of self-admistrated method, which is one of the sampling methods, First, among the current bodyguarding related theoretical disciplines significant differences among groups was presented by the evaluations on bodyguarding science, traffic safety management, fire extinguishing, secretary science, administration, psychology, sports education, sport physiology, jurisprudence and philosophy, which showed differences among groups through the multiple comparison, But there was no significant difference among the means of the groups concerned with the other curriculum, We could know that more curriculum is needed to facilitate the private bodyguarding in disciplines and system of the current theory in this study. For it is predicted the demand for the private bodyguarding will increase continuously in the future. for which we should prepare. Thus it is required to increase the theoretical curriculum of the private bodyguarding. That is. the models of curriculum like introduction to machinary guarding. introduction to communication. computer theory and so on are required to be established. In addition to that. it must be noticed that the current private bodyguarding is not guaranteed by the legitimate institution. But the private bodyguarding is related to the police service. thus the curriculum of jurisprudence and police science should be studied together.

  • PDF

Flame Retardant and Heat Radiating Composite Consisting of Polyurethane and Modified Boron Nitride (폴리우레탄과 개질된 질화붕소로 이루어진 난연성 방열 복합체)

  • Kim, Min-gyu;Lee, Chang-rock;Jo, Nam-Ju
    • Applied Chemistry for Engineering
    • /
    • v.31 no.5
    • /
    • pp.487-494
    • /
    • 2020
  • Polyurethane/modified boron nitride (PU/m-BN) composite was synthesized from the poly(tetra methylene glycol) (PTMG), 4,4'-methylenebis(phenyl isocyanate) (MDI), and modified boron nitride (m-BN). The modification of boron nitride and synthesis of PU/m-BN composite were confirmed by Fourier transform infrared (FT-IR) spectroscopic analyses. The mechanical properties of the PU/m-BN composites were measured using the universal testing machine (UTM) and the thermal properties of the composites were investigated ser flash analysis (LFA) and UL94 measurements. As a result, the thermal conductivity of the polyurethane composite increased to 1.19 W/m·K, and the flame retardancy of the easy to burn polyurethane, which was not self-extinguishing was improved to UL94 V-1 grade.

The Study on the Legal Improvement for Fire Protection in Wooden Architectural Heritage (목조건축 문화재의 화재방호를 위한 법규 개선에 관한 연구)

  • Kim, Dong Cheol;Roh, Sam Kew;Ham, Eun Gu
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2015
  • This study covers securing legal systems and institutions regarding the standards for installing fire prevention facilities to prevent fire on wooden architectural heritage. Conflicts among relevant laws were revealed and problems related to fire prevention performance, technical standards, responsibilities, etc. in the process of establishing legal fire prevention equipment and the equipment for self-extinguishing were identified through pondering over current legal systems of fire prevention facilities. To resolve the problems, at least the principle to preserve original shapes of wooden architectural heritage should be secured even though fire prevention facilities are installed and the installation process should be regulated by laws considering features of fire on wooden architectural heritage so that fire prevention performance can be guaranteed. The directions to improve installing system through legalization of design, construction, and audit review institutions and legalization of the technical standards for fire prevention facilities were suggested to guarantee performance when establishing fire prevention facilities for wooden architectural heritage.

A Study on the Confirmation of non-flammabikity of the Cast Resin Mold Transformer in Subway Substation (지하철 변전실용 진공주형형 몰드변압기의 난연성 확인에 관한 연구)

  • 정용기;장성규;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 1998
  • This dissertationhas confirmed the non-flam mability of cast mold transformer that is increasingly used lately. As a research progress, the investigation has been performed on the installation status and each line of the subway system which have the most mold transformer accidents, and the impediment status of the transformer for rectifier and the high-voltage distribution transformer per each manufacturer. Then, a high voltage mold of the actual mold transformer has been installed in the horiwntal heating furnace and the heat has been applied by the standard heating temperature curve of KSF 2257(Fireproof testing meth od of the construction structures: 1993). Accordingly, the combustibility of the mold transformer based on the test results has been found that 78 minutes has been required for the complete burning per the KSF 2257 combustion test curve and that, after stopping the heat application of the horizontal furnace after ignition, the flame progress has not been made but shown as the self-extinguishing characteristics when the flame progress has been checked. Thus, the non-flammability and self-extinguishability of the mold transformer have been confirmed. The result of this dissertation has indicated that the accident involving mold transformer has been progressed and expanded by the dielectric breakdown or void due to the crack in the mold rather than a fire accident caused by a short-circuit or an overload.r an overload.

  • PDF