• 제목/요약/키워드: Self etching

검색결과 264건 처리시간 0.028초

RIE 공정으로 제조된 블랙 실리콘(Black Silicon) 층을 사용한 표면 증강 라만 산란 기판 제작 (Fabrication of surface-enhanced Raman scattering substrate using black silicon layer manufactured through reactive ion etching)

  • 김형주;김봉환;이동인;이봉희;조찬섭
    • 센서학회지
    • /
    • 제30권4호
    • /
    • pp.267-272
    • /
    • 2021
  • In this study, Ag was deposited to investigate its applicability as a surface-enhanced Raman scattering substrate after forming a grass-type black silicon structure through maskless reactive ion etching. Grass-structured black silicon with heights of 2 - 7 ㎛ was formed at radio-frequency (RF) power of 150 - 170 W. The process pressure was 250 mTorr, the O2/SF6 gas ratio was 15/37.5, and the processing time was 10 - 20 min. When the processing time was increased by more than 20 min, the self-masking of SixOyFz did not occur, and the black silicon structure was therefore not formed. Raman response characteristics were measured based on the Ag thickness deposited on a black silicon substrate. As the Ag thickness increased, the characteristic peak intensity increased. When the Ag thickness deposited on the black silicon substrate increased from 40 to 80 nm, the Raman response intensity at a Raman wavelength of 1507 / cm increased from 8.2 × 103 to 25 × 103 cps. When the Ag thickness was 150 nm, the increase declined to 30 × 103 cps and showed a saturation tendency. When the RF power increased from 150 to 170 W, the response intensity at a 1507/cm Raman wavelength slightly increased from 30 × 103 to 33 × 103 cps. However, when the RF power was 200 W, the Raman response intensity decreased significantly to 6.2 × 103 cps.

Comparative evaluation of Emblica officinalis as an etchant and an MMP inhibitor with orthophosphoric acid and chlorhexidine on the microshear bond strength of composite resin: an ex vivo study

  • Divya Sangeetha Rajkumar;Annapoorna Ballagere Mariswamy
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.36.1-36.11
    • /
    • 2021
  • Objectives: This study aimed to evaluate Emblica officinalis (Indian gooseberry or amla) as an acid etchant and matrix metalloproteinase (MMP) inhibitor, and to compare its effect on the microshear bond strength of composite resin with orthophosphoric acid (OPA) and 2% chlorhexidine (CHX) as an acid etchant and MMP inhibitor, respectively. Materials and Methods: The etching effect and MMP-inhibiting action of amla on dentin samples were confirmed by scanning electron microscopy (SEM) and gelatin zymography, respectively. Dentinal slabs (3 mm thick) from 80 extracted human molars were divided into 10 and 20 samples to form 2 control groups and 3 experimental groups. Groups 1, 2, and 4 were etched with OPA and groups 3 and 5 with amla juice. An MMP inhibitor was then applied: CHX for group 2 and amla extract for groups 4 and 5. Groups 1 and 3 received no MMP inhibitor. All specimens received a standardized bonding protocol and composite resin build-up, and were subjected to microshear bond strength testing. The force at which the fracture occurred was recorded and statistically analyzed. Results: Amla juice had a similar etching effect as a self-etch adhesive in SEM and 100% amla extract was found to inhibit MMP-9 by gelatin zymography. The microshear bond strength values of amla were lower than those obtained for OPA and CHX, but the difference was not statistically significant. Conclusions: Amla has a promising role as an acid etchant and MMP inhibitor, but further studies are necessary to substantiate its efficacy.

열순환 횟수에 따른 복합레진의 미세누출 (MICROLEAKAGE OF COMPOSITE RESIN RESTORATION ACCORDING TO THE NUMBER OF THERMOCYCLING)

  • 김창윤;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제32권4호
    • /
    • pp.377-384
    • /
    • 2007
  • 작금의 치질 접착시스템은 도말층 처리 방법에 따라 전부식형과 자가부식형 접착시스템으로 대별된다. 이러한 두 가지 접착시스템의 효용성을 비교, 평가하고 열순환 횟수에 따른 미세누출도 변화를 측정하기 위해 각각의 접착시스템으로 수복된 우치 5급 수복물에, 수복 초기의 효용성를 의미하는 500회의 열순환 자극과 상대적으로 긴 내구성을 의미하는 5,000회의 열순환 자극을 부여한 다음, 전기화학적 방법으로 측정하였다. 건전한 40개의 단근관을 가진 우치를 이용하여 백악법랑 경계부를 중심으로 5급 와동을 형성하였으며, 치아를 각각 10개씩 4개의 실험군 (열순환 횟수 2종 $\times$ 복합레진 수복 2개 군)으로 분류하였다. 20개의 치아에는 전부식형 접착시스템인 Single bond와 Z250 (shade A4)을, 나머지 20개의 치아에는 자가부식형 접착시스템인 AQ bond와 Metafil (shade A4)로 각각 충전하고 광중합기 (XL2500, 3M ESPE, St. Paul, MN, USA)를 이용하여 $600\;mW/cm^2$의 광도로 40초간 광중합하였다. 모든 시편을 실온에서 24 시간동안 증류수에 보관한 다음, 연마하고 각 수복물의 반은 섭씨 5도와 55도의 수조에 30초씩 담궜으며 이동 시간 10초의 열순환 (thermocycling)을 500회 시행하였고, 나머지 반은 5,000회 실시하였다. 미세 전류 측정을 위해 직류 공급원인 TOE 8841 (TOELLNER electronic instrument GMBH, Germany)을 이용하여 10 V의 전압을 부여하였으며 6514 system Electrometer (Keithley Co., Cleveland, Ohio, USA)로 미세전류 (${\mu}A$)를 측정하였다. 전류를 흐르게 한 다음 5-10분까지 20초 간격으로 측정 한 15개 측정치의 평균값을 시편의 미세전류 측정치로 인정하였다. 각 군간의 미세전류 측정치에 대한 유의성은 수복방법 및 열순환 횟수의 변수에 대한 Two-way ANOVA test로 95% 유의 수준에서 검증하여 다음과 같은 결과를 얻었다. 수복방법과 열순환 횟수 사이의 상호작용은 없었으며 (p = 0.485), 열순환 횟수에 따른 미세누출의 차이도 없었다(p = 0.814). 그러나 자가부식형 접착시스템인 AQ Bond와 Metafil로 수복된 실험군이 전부식형 접착시스템인 Single Bond와 Z250으로 수복된 군에 비해 적은 미세누출도를 보였다 (p = 0.005).

전극 구조에 관한 2차원 RF 플라즈마의 모델링 (Modeling of Two-dimensional Self-consistent RF Plasmas on Discharge Chamber Structures)

  • 소순열;임장섭;김철운
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.1-8
    • /
    • 2005
  • 본 연구에서는 2차원적 유체 모델을 통하여 보다 실질적인 플라즈마를 이해하고자 하였으며, 기하학적인 방전전극 구조를 반영하도록 전극단에서 챔버 외벽의 거리를 변화시키면서 플라즈마의 특성을 정량적으로 비교 분석하고자 하였다. 방전 챔버의 구조로서, 전극의 반경과 방전 챔버의 높이는 일정하게 유지하면서 방전 챔버의 넓이를 변화시킴에 따라 형성되는 플라즈마의 특성을 분석하였다. 그 결과, 전극단과 챔버 외벽의 거리가 짧을수록 그 영역에서 전계가 강하게 형성되어, 외벽을 향하는 각 입자들의 움직임도 매우 활발하다는 것을 알 수 있었다. 또한, 전각단과 외벽과의 거리가 짧을수록 전극 면상에서 형성되는 입자들의 수밀도와 유속의 변화가 일정하게 형성되는 것을 알 수 있었다. 이러한 결과는 웨이퍼의 대구경화에 따른 플라즈마의 균일성을 고려할 경우에 매우 효과적일 것으로 고려되어 진다.

에어백용 압저항형 외팔보 미소 가속도계의 설계, 제작 및 시험 (Design, Fabricaiton and Testing of a Piezoresistive Cantilever-Beam Microaccelerometer for Automotive Airbag Applications)

  • 고종수;조영호;곽병만;박관흠
    • 대한기계학회논문집A
    • /
    • 제20권2호
    • /
    • pp.408-413
    • /
    • 1996
  • A self-diagnostic, air-damped, piezoresitive, cantilever-beam microaccelerometer has been designed, fabricated and tested for applications to automotive electronic airbag systems. A skew-symmetric proof-mass has been designed for self-diagnostic capability and zero transverse sensitivity. Two kinds of multi-step anisotropic etching processes are developed for beam thickness control and fillet-rounding formation, UV-curing paste has been used for sillicon-to-glass bounding. The resonant frequency of 2.07kHz has been measured from the fabricated devices. The sensitivity of 195 $\mu{V}$/g is obtained with a nonlinearity of 4% over $\pm$50g ranges. Flat amplitude response and frequency-proportional phase response have been obserbed, It is shown that the design and fabricaiton methods developed in the present study yield a simple, practical and effective mean for improving the performance, reliability as well as the reproducibility of the accelerometers.

Marginal microleakage of cervical composite resin restorations bonded using etch-and-rinse and self-etch adhesives: two dimensional vs. three dimensional methods

  • Khoroushi, Maryam;Ehteshami, Ailin
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.83-90
    • /
    • 2016
  • Objectives: This study was evaluated the marginal microleakage of two different adhesive systems before and after aging with two different dye penetration techniques. Materials and Methods: Class V cavities were prepared on the buccal and lingual surfaces of 48 human molars. Clearfil SE Bond and Single Bond (self-etching and etchand-rinse systems, respectively) were applied, each to half of the prepared cavities, which were restored with composite resin. Half of the specimens in each group underwent 10,000 cycles of thermocycling. Microleakage was evaluated using two dimensional (2D) and three dimensional (3D) dye penetration techniques separately for each half of each specimen. Data were analyzed with SPSS 11.5 (SPSS Inc.), using the Kruskal-Wallis and Mann-Whitney U tests (${\alpha}=0.05$). Results: The difference between the 2D and 3D microleakage evaluation techniques was significant at the occlusal margins of Single bond groups (p = 0.002). The differences between 2D and 3D microleakage evaluation techniques were significant at both the occlusal and cervical margins of Clearfil SE Bond groups (p = 0.017 and p = 0.002, respectively). The difference between the 2D and 3D techniques was significant at the occlusal margins of non-aged groups (p = 0.003). The difference between these two techniques was significant at the occlusal margins of the aged groups (p = 0.001). The Mann-Whitney test showed significant differences between the two techniques only at the occlusal margins in all specimens. Conclusions: Under the limitations of the present study, it can be concluded that the 3D technique has the capacity to detect occlusal microleakage more precisely than the 2D technique.

확산펌프 기반의 O2 축전결합 플라즈마를 이용한 PMMA와 폴리카보네이트의 건식 식각 (Dry Etching of PMMA and Polycarbonate in a Diffusion Pump-based Capacitively Coupled O2 Plasma)

  • 박주홍;이성현;최경훈;노호섭;이제원
    • 한국재료학회지
    • /
    • 제19권8호
    • /
    • pp.421-426
    • /
    • 2009
  • We report on the capacitively coupled O2 plasma etching of PMMA and polycarbonate (PC) with a diffusion pump. Plasma process variables were process pressure and CCP power at 5 sccm $O_2$ gas flow rate. Characterization was done in order to analyze etch rate, etch selectivity, surface roughness, and morphology using stylus surface profilometry and scanning electron microscopy. Self bias decreased with increase of process pressure in the range of 25$\sim$180 mTorr. We found an important result for optimum pressure for the highest etch rate of PMMA and PC, which was 60 mTorr. PMMA and PC had etch rates of 0.46 and 0.28 ${\mu}m$/min under pressure conditions, respectively. More specifically, etch rates of the materials increased when the pressure changed from 25 mTorr to 60 mTorr. However, they reduced when the pressure increased further after 60 mTorr. RMS roughnesses of the etched surfaces were in the range of 2.2$\sim$2.9 nm. Etch selectivity of PMMA to a photoresist was $\sim$1.5:1 and that of PC was $\sim$0.9:1. Etch rate constant was about 0.04 ${\mu}m$/minW and 0.02 ${\mu}m$/minW for PMMA and PC, respectively, with the CCP power change at 5 sccm $O_2$ and 40 mTorr process pressure. PC had more erosion on the etched sidewall than PMMA did. The OES data showed that the intensity of the oxygen atomic peak (777.196 nm) proportionally increased with the CCP power.

접착레진의 추가도포가 자가부식형 접착제의 상아질에 대한 미세인장접착강도에 미치는 영향 (Effect of additional coating of bonding resin on the microtensile bond strength of self-etching adhesives to dentin)

  • 정문경;조병훈;손호현;엄정문;한영철;정세준
    • Restorative Dentistry and Endodontics
    • /
    • 제31권2호
    • /
    • pp.103-112
    • /
    • 2006
  • 본 실험에서는 자가부식형 접착제와 콤포짓트 레진 사이의 산도의 차이를 완화시킬 수 있는 접착레진을 자가부식형 접착제 위에 추가적으로 도포할 경우, 상아질에 대한 접착력을 개선할 수 있는지를 연구하였다. 자가부식형 접착제로는 실험실에서 직접 제작한 실험용 자가부식형 접착제 (pH: 1.96)와 Adper Prompt (3M ESPE, VSA, pH: 1.0)를 사용하였으며, 중성의 접착레진으로 All-Bond 2의 D/E bonding resin (Bisco Inc., USA, pH: 6.9)을 사용하였다. 두 대조군에서는 두 가지 자가부식형 접착제를 각각 두번씩 도포하였으며, 두 실험군에서는 각 자가부식형 접착제를 한번 도포한 후 그 위에 D/E bonding resin을 추가 도포하였다. Z-250 하이브리드 복합레진을 쌓아올려 모레시계 형태의 시편을 제작하여 미세인장강도를 측정하고 t-test를 이용하여 비교하였다. 파절 양상은 입체현미경과 주사전자현미경을 이용하여 관찰하였다. D/E bonding resin을 추가 도포한 미세 인장접착강도는 유의하게 증가되었고, 접착층과 복합레진 또는 접착층과 상아질 사이의 파절을 보인 시편의 수는 감소하고, 접착층 내의 파절을 보인 시편의 수는 증가되었다. 따라서 자가부식형 접착제와 복합레진의 산도의 차이를 완화할 수 있는 중성의 접착레진을 추가 도포할 경우 미세인장접착강도를 증가시킬 수 있음을 확인하였다.

자가 산부식 접착제로 접착된 광중합과 이원중합 복합레진의 법랑질 결합강도 비교 (COMPARATIVE ENAMEL BOND STRENGTH BETWEEN LIGHT-AND DUAL-CURED COMPOSITES BONDED BY SELF-ETCHING ADHESIVES)

  • 조영곤;유상훈
    • Restorative Dentistry and Endodontics
    • /
    • 제32권1호
    • /
    • pp.1-8
    • /
    • 2007
  • 본 연구는 자가 산부식 접착제를 적용한 법랑질에 광중합과 이원중합 복합레진을 접착시켜 접착제와 복합레진의 종류에 따른 미세전단 결합강도를 상호 비교하기 위하여 시행하였다. 발거된 상 하악 대구치를 근, 원심 방향으로 1 mm 두께가 되도록 절단하여 사용된 접착제의 종류에 따라 Xeno 군 (Xeno III), Adper 군 (Adper Prompt L-Pop), AQ 군(AQ Bond)으로 분류하였다. 각 시편의 법랑질 표면에 각 군에 해당하는 접착제를 적용한 후 Tygon tube를 이용하여 광중합형 복합레진 (Z 250)이나 이원중합 복합레진 (Luxacore)을 접착하였다. 실온의 증류수에 24시간 동안 보관한 후. universal testing machine을 이용하여 각 시편의 복합레진과 법랑질의 접착계면이 파절될 때가지 분당 1 mm의 crosshead speed를 가하여 미세전단 결합강도를 측정 한 후 통계학적으로 분석하여 다음과 같은 결과를 얻었다. 1. 동일 접착제로 결합된 광중합과 이원중합 복합레진의 법랑질에 대한 미세인장 결합강도는 광중합 복합레진에서 통계학적으로 높게 나타났다 (p<0.05). 2. Z 250을 접착시킨 각 군의 미세전단 결합강도는 Xeno군에서 $7.73{\pm}2.01\;MPa$, Adper군에서 $6.74{\pm}1.80\;MPa$, AQ 군에서 $9.59{\pm}2.51\;MPa$를 나타내어 AQ 군이 Adper군 보다 통계학적으로 높게 나타났다 (p<0.05). 3. Luxacore를 접착시킨 각 군의 미세전단 결합강도는 Xeno군에서 $5.19{\pm}1.32\;MPa$, Adper 군에서 $3.41{\pm}1.19\;MPa$, AQ군에서 $4.50{\pm}0.96\;MPa$를 나타내어 Xeno군이 Adper군 보다 통계학적으로 높게 나타났다(p<0.05).

수종의 치질 접착제의 미백 처리된 법랑질에 대한 전단접착강도 비교 (Comparison of shear bond strength of different bonding systems on bleached enamel)

  • 김광근;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제29권1호
    • /
    • pp.30-35
    • /
    • 2004
  • 치아 미백술은 치아의 심미성을 향상시키는 가장 보존적인 방법의 하나로 인식되어져 왔으며 최근의 심미치과에 대한 관심의 증가와 함께 그 빈도가 급격히 증가하고 있는 술식의 하나이다. 일반적으로 치아 미백술 후 바로 접착수복을 할 경우 결합력이 감소하는 것으로 알려져 있으며 이를 해소하기 위해 일정시간 경과 후 접착수복 술식을 시행할 것을 권장 하고 있다. 자가산부식형 (self-etching primer system) 접착제는 기존의 접착제와 다른 성분으로 인해 치아미백제에 의한 영향에 대해 잘 알려져 있지 않은 상태이다. 이에 본 실험에서는 미백술을 시행한 법랑질 상에서 서로 다른 세 가지의 접착 시스템을 이용하여 미백술 후의 지연 시간이 결합력에 미치는 영향을 비교하고자 하였다. 발거한 대구치 68개를 물기가 있는 상태에서 근원심으로 절단하고 치관부를 자가중합 레진에 식립하여 시편을 제작하였다. 세 가지 접착제로 $One-step^{\circledR}$, Clearfil SE Bond $primer^{\circledR}$, One-up Bond $F^{\circledR}$를 이용하였다. 각 접착제를 미백을 시행하지 않는 대조군과 미백 시행 후 바로 접착한 즉시 접착군, 그리고 2주간 생리식염수에 보관한 후에 접착한 지연군으로 나누어 총 9개의 실험군으로 나누었다. 접착제를 처리한 면에 Clearfil $AP-X^{\circledR}$ 복합레진을 2mm충전하고, 40초간 광중합을 시행하였다. 24시간 후 전단접착강도를 측정하였으며, 그 결과는 다음과 같이 나타났다. $One-step^{\circledR}$의 경우, 즉시 접착군에서 지연 접착군보다 유의성 있게 낮은 접착강도를 나타내었다. Clearfil SE $Bond^{\circledR}$의 경우, 즉시 접착군과 미백을 시행하지 않은 군간에는 접착 강도에 유의한 차가 없었으나,지연접착군에서는 낮은 강도를 나타내었다. One-Up Bond F$^{\circledR}$의 경우, 즉시 접착군에서 유의성 있게 낮은 전단접착강도를 나타내었고, 전반적인 접착 강도가 다른 두 접착제에 비해서 유의성 있게 낮은 값을 보였다. $One-step^{\circledR}$을 사용할 경우 지연접착을 하는 것이 추천되며, Clearfil SE Bond$^{\circledR}$의 경우에는 즉시 접착을 시행하더라도 영향을 적게 받는 것으로 나타났으며, One-Up Bond $F^{\circledR}$의 경우 미백술 후 접착수복 과정에 사용에 제한이 있는 것으로 나타났다.