• Title/Summary/Keyword: Self Resonance

Search Result 264, Processing Time 0.023 seconds

Self-Alignment/Navigation Performance Analysis in the Accelerometer Resonance State Generated by Dither Motion of Ring Laser Gyroscope in Laser Inertial Navigation System (레이저 관성항법장치에서 링레이저 자이로 디더 운동에 의한 가속도계 공진이 자체 정렬/항법 성능에 미치는 영향 분석)

  • Kim, Cheonjoong;Lim, Kyungah;Kim, Seonah
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.577-590
    • /
    • 2021
  • In this paper, we theoretically analyzed the self-alignment/navigation performance in the accelerometer resonance state generated by dither motion of ring laser gyroscope in LINS and verified it through simulation. As a result of analysis, it is confirmed that the amplitude of the accelerometer measurement amplified in the accelerometer resonance state is decreased in the process of sampling per the navigation calculation period and that frequency is changed by the aliasing effect too. It was also analysed that the attitude error in self-alignment is determined by the amplitude/frequency of the accelerometer measurement, the gain of the self-alignment loop, and the velocity and position error in the navigation is determined by the amplitude/frequency/phase error of the accelerometer measurement. This analysis and simulation results show that the self-alignment and navigation performance is not be degraded only when the amplification factor of the accelerometer measurement in the accelerometer resonance state is 3 or less

Understanding Protocols in Magnetic Resonance Spectroscopy: Focusing on Literature Studies (자기공명분광 검사 시 프로토콜 이해: 문헌연구 중심으로)

  • MinKyu Back;YoungHwan Ryu;EunHoe Goo
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.405-409
    • /
    • 2023
  • The magnetic resonance imaging method is a technology that can diagnose patients using local magnetic field through local magnetic field through local magnetic field through local magnetic field and STEAM method using local magnetic field Currently, many diseases can diagnose many diseases using self-resonance methods. The purpose of this study is to provide optimal information about using magnetic resonance imaging method according to patients.In many studies, self-resonance imaging showed that self-resonance methods can effectively inspect brain cancer and liver diseases. mong them, this study, brain tumor tests, cervical cancer tests based on literature, there were effective parts of these four diseases, but it was clearly found that they should not use in clinical trials, but it is clearly found to improve and improve and improve. Therefore, it is believed that it will be based on the future studies.

Celebrity Endorser and Purchase Intention: The Mediating Role of Resonance-Based Self-Attitude and Brand Credibility

  • GUNAWAN, Stephanie Angelina;HERMAWAN, Asep;WIDJAJA, Anton Wachidin;BERNARTO, Innocentius
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.7
    • /
    • pp.603-611
    • /
    • 2021
  • This study aims to analyze the mediating influences of resonance-based self-attitude and brand credibility in a relationship between celebrity endorser credibility and celebrity endorser congruity toward brand purchase intention in the current dynamic business environment. It employs a quantitative research method and reports on a survey, using a questionnaire, including the population of consumers of various instant coffee brands in several cities in Indonesia. The number of respondents in this study was 432 people. The analysis was performed using Partial Least Square Structural Equation Modeling and SmartPLS software. The analysis consisted of descriptive statistics, evaluation of the measurement model, evaluation of the structural model, and hypothesis testing. The results partially support the model developed. The findings suggest that the instant coffee product advertising in Indonesia needs to create brand messages focusing on the formation of resonance-based self-attitude from consumers to increase the influence of celebrity endorser credibility and celebrity endorser congruity, as well as the brand credibility towards the brand purchase intention. This study contributes to the marketing literature and the theory of planned behavior by providing empirical evidence on the relationship between celebrity endorser credibility, celebrity endorser congruity, resonance-based self-attitude, brand credibility, and brand purchase intention.

Design of the Self-Oscillation UV Flash Lamp Power Supply and the Characteristic of its Operation Using Self-resonance of the Transformer (트랜스포머의 자가 공진(Self-Resonance) 특성을 이용한 자가 발진(Self-Oscillation) UV 발생 플래시램프 전원장치설계 및 그 동작 특성)

  • Kim, Shin-Hyo;Cho, Dae-Kweon
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.37
    • /
    • pp.35-44
    • /
    • 2014
  • 해상 및 육상용 살균방식으로 UV를 사용하는 시스템이 주종을 이루고 있으며, 의료, 생활, 산업용 시스템에 널리 적용되고 있으며, 근래에는 평형수 처리 방식으로 UV를 적용하는 사례가 등장하고 있다. UV 광원으로는 다양한 램프가 있으며 그 중 제논플레시 램프는 강한 섬광형 방전과 함께 다량의 UV를 방출하는 특성이 있어 매우 효과적이다. 다만, 타 광원에 비하여 높은 방전전압으로 인하여 기존의 전원장치 설계 방식으로는 장치의 크기가 크고 복잡한 문제가 있었으며, 이를 개량하기 위한 본 연구에서는 트랜스포머의 자가 공진(self-resonance)을 이용한 설계 기법을 제안하며, 트랜스포머의 특정주파수에서 고유임피던스 성분을 이용하여 출력전압을 필터링하면 제논방전관이 자가 발진방식으로 동작하므로 종래의 회로구성보다 간단하고 경제적인 아크방전 파워 스테이지의 구성이 가능하다.

  • PDF

Design of the self-oscillation UV flash lamp power supply and the characteristic of its operation using self-resonance of the transformer (트랜스포머의 자가 공진(Self-Resonance)특성을 이용한 자가 발진(Self-Oscillation) UV(Ultra Violet) 발생 플래시램프 전원장치설계 및 그 동작 특성)

  • Kim, Shin-Hyo;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.48-55
    • /
    • 2014
  • These Xenon flashlamp power supply for Ultra Violet has converter with high voltage conversion ratio. General model is composed of transformer with high voltage conversion ratio and voltage doubler rectifier circuit. Purpose of power supply leads dielectric breakdown of Xenon flashlamp and passes current rapidly. When passing current, it has to limit current to avoid over-heat, damage of electrode and acceleration of gas oxidation which are cause of performance degradation of lamps. Generally, inductors and resistors, which are called as "Ballast," are used to limit currents. Generally, Transformer has high turn ratio to make high voltages. But we can get high voltages using the transformer with low turn ratio which is driven with self resonance. Also, an advantage of self resonance is to make a circuit simply through impedance of transformer in resonance frequency which filters output voltage. As using an unique impedance of transformer, the circuit does not need other impedance elements like the ballast. So the power supply assures high efficiency of the arc discharge.

Analysis and Performance of the Self Excited Eddy Current Brake

  • Cho, Sooyoung;Jeong, Teachul;Bae, Jaenam;Yoo, Changhee;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.459-465
    • /
    • 2017
  • This paper describes a performance analysis of self-excited eddy current brake(SECB). Stator winding of SECB is connected by capacitor instead of voltage source, and SECB's braking force is generated by L-C resonance. SECB has wide range of driving and nonlinear inductance as well. Therefore, it is important to select capacitance based on the value of inductance. This paper discusses about the process of deciding capacitance and the change of resonance frequency based on the inductance change in each speed. Also the braking force was confirmed by the experimental model of SECB.

A Case Study on Literary Therapy Using Self-Narritive Analysis -Application of Convergence Techniques in Epic Analysis- (자기서사 분석을 활용한 문학치료 사례연구 -서사분석의 융복합적 기법적용-)

  • Kim, Eunjung
    • Journal of Digital Convergence
    • /
    • v.19 no.3
    • /
    • pp.273-278
    • /
    • 2021
  • The purpose of this study is to help self-healing by identifying self-description by utilizing the self-description diagnosis of literary therapy and the resonance of the work narrative. Therefore, the research was conducted through the methodology of literature therapy, which uses the self-introduction team of literary therapy and basic photography team to understand their own narrative and to heal themselves through resonance with the work narrative. Through this study, we understood that it is possible to understand and identify and understand one's psychological problems through self-description and self-culture techniques. This case study revealed that it can be used as a new technique for understanding self-description by applying the methodology of literary therapy and for healing self-exploration through resonance with the work narrative.

Detection of Escherichia coli O157:H7 Using Immunosensor Based on Surface Plasmon Resonance

  • Oh, Byung-Keun;Kim, Young-Kee;Bae, Young-Min;Lee, Won-Hong;Choi, Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.5
    • /
    • pp.780-786
    • /
    • 2002
  • An immunosensor based on surface plasmon resonance (SPR) with a self-assembled protein G layer was developed for the detection of Escherichia coli O157:H7. A self-assembled protein C layer on a gold (Au) surface was fabricated by adsorbing the mixture of 11-mercaptoundecanoic acid (MUA) and hexanethiol at various molar ratios and by activating chemical binding between free amine (-$NH_2$) of protein G and 11-(MUA) using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDAC) in series. The formation of a self-assembled protein G layer on an Au substrate and the binding of the antibody and antigen in series were confirmed by SPR spectroscopy. The surface morphology analyses of the self-assembled protein G layer on the Au substrate, monoclonal antibody (Mab) against E. coli O157:H7 which was immobilized on protein G, and bound E. coli O157:H7 extracts on Immobilized Mab against E. coii O157:H7 were performed by atomic force microscopy (AFM). The detection limit of the SPR-based immunosensor for E. coli O157:H7 was found to be about $10^4$ cells/ml.

Using the 3D EM simulator analyze characteristics of the self resonance frequency of the embedded capacitor (3D EM Simulator를 이용한 Embedded Capacitor의 SRF(Self Resonance Frequency) 특성 분석)

  • You, Hee-Wook;Koo, Sang-Mo;Park, Jae-Yeong;Koh, Jung-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1366-1367
    • /
    • 2006
  • Embedded capacitor technology is one of the effective packaging technologies for further miniaturization and higher performance of electric package systems. So we used the 3D EM simulator for embedded capacitor design in 8-layed PCB(Printed Circuit Board). The designed capacitors value are 2 pF, 5pF, 10 pF, respectly. we investigated characteristics of capacitance - frequency and SRF(Self Resonance Frequency) as changing the rate of hight and width of upper pad of embedded capacitors.

  • PDF

A Study on the Wireless Power Transfer System using Magnetic Resonance at the 1[MHz] Frequency Band (1[MHz] 대역의 자계 공명을 이용한 무선 전력 전송 장치에 관한 연구)

  • Park, Jeong-Heum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.75-81
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed, analyzed by circuit analysis methode and the calculated transfer function was compared with the measured one. The self-resonant coil was made up of the commonly used capacitor which had the lumped capacitance and it enabled the stable magnetic resonance not to be affected by the circumstance. The transmission efficiency of this system was 70[%] at the 15[cm] between the transmission and receiving coil and the measured transfer function was similar to the calculated one, which means the circuit analysis methode is valid in this system. When the intermediate coils were added between the transmission and receiving coil, the transmission efficiency was increased, which produced the increase of transfer distance. In the case of the five intermediate coils adding, the 35[%] transmission efficiency was achived at the 90[cm] distance.