• 제목/요약/키워드: Self Protection

Search Result 677, Processing Time 0.03 seconds

An Autonomous Optimal Coordination Scheme in a Protection System of a Power Distribution Network by using a Multi-Agent Concept

  • Hyun, Seung-Ho;Min, Byung-Woon;Jung, Kwang-Ho;Lee, Seung-Jae;Park, Myeon-Song;Kang, Sang-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.89-94
    • /
    • 2002
  • In this paper, a protection system using a Multi-Agent concept for power distribution networks is proposed. Every digital over current relay(OCR) is developed as an agent by adding its own intelligence, self-tuning and communication ability. The main advantage of the Multi-Agent concept is that a group of agents work together to achieve a global goal which is beyond the ability of each individual agent. In order to cope with frequent changes in the network operation condition and faults, an OCR agent, suggested in this paper, is able to detect a fault or a change in the network and find its optimal parameters for protection in an autonomous manner considering information of the whole network obtained by communication between other agents. Through this kind of coordination and information exchanges, not only a local but also a global protective scheme is completed. Simulations in a simple distribution network show the effectiveness of the suggested protection system.

An Analysis Of The Importance Of The Evaluation Criteria Of The Real Estate Financial Consumer Protection System - Utilizing The AHP Technique (부동산 금융소비자 보호 체계의 평가 기준 간 중요도 분석: AHP 기법을 활용하여)

  • Lee, Yeon-Jae;Shin, Seung-Woo
    • Asia-Pacific Journal of Business
    • /
    • v.13 no.3
    • /
    • pp.227-243
    • /
    • 2022
  • Purpose - This study surveyed real estate financial consumers and financial company staff regarding the components of the financial consumer protection system to seek detailed improvement plans for the Financial Consumer Protection Act. Design/methodology/approach - The Analytic Hierarchy Process (AHP) technique is applied. Findings - Both consumers and staff highly evaluated the importance of the preventive measures in the main classification factors. Regarding the sub-classification factors of preventive measures, consumers emphasized the responsible management of investment staff and financial institutions; however, the staff stressed the principle of effectiveness and efficiency. Regarding the elements of ex-post remedies, consumers answered that fast remedy would have a significant effect. At the same time, staff believed that punitive measures hinder free trading and investment activities. Regarding the sub-sub classification factors of prevention measures, the consumers value responsible management of staff and financial companies, while the staff tend to prefer the importance of the self-regulatory governance. Research implications or Originality - Based on the above results, financial regulatory authorities should find a balance between preventive and ex-post components once focusing on preventative measures. Our paper is one of the first research findings in this field of financial consumer protection system in Korea.

Protection properties of HTS coil charging by rotary HTS flux pump in charging and compensation modes

  • Han, Seunghak;Kim, Ji Hyung;Chae, Yoon Seok;Quach, Huu Luong;Yoon, Yong Soo;Kim, Ho Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.19-24
    • /
    • 2021
  • The low normal zone propagation velocity (NZPV) of high-temperature superconducting (HTS) tape leads to a quench protection problem in HTS magnet applications. To overcome this limitation, various studies were conducted on HTS coils without turn-to-turn insulation (NI coils) that can achieve self-protection. On the other hand, NI coils have some disadvantages such as slow charging and discharging time. Previously, the HTS coils with turn-to-turn insulation (INS coils) were operated in power supply (PS) driven mode, which requires physical contact with the external PS at room-temperature, not in persistent current mode. When a quench occurs in INS coils, the low NZPV delays quench detection and protection, thereby damaging the coils. However, the rotary HTS flux pump supplies the DC voltage to the superconducting circuit with INS coils in a non-contact manner, which causes the INS coils to operate in a persistent current mode, while enabling quench protection. In this paper, a new protection characteristic of HTS coils is investigated with INS coils charging through the rotary HTS flux pump. To experimentally verify the quench protection characteristic of the INS coil, we investigated the current magnitude of the superconducting circuit through a quench, which was intentionally generated by thermal disturbances in the INS coil under charging or steady state. Our results confirmed the protection characteristic of INS coils using a rotary HTS flux pump.

Awareness of Dental Hygiene Department Students regarding the Protection of Patients' Personal Information (환자 개인정보보호에 대한 치위생 전공 학생의 인식도)

  • Cho, Myung-Sook;Lee, Seong-Sook
    • Journal of Korean Dental Hygiene Science
    • /
    • v.4 no.1
    • /
    • pp.89-98
    • /
    • 2021
  • Background: The purpose of the present study was to gather basic data necessary for developing an educational program regarding the protection of patients' personal information. Such a program would stress the importance of the protection of patients' personal information for dental hygiene students obtaining clinical practice. Methods: A self-reported questionnaire-based survey was conducted targeting dental hygiene undergraduates who were obtaining clinical practice in the capital region. A total of 543 questionnaires were included in the analysis. Results: The results of this study were as follows: 1) the average score for awareness of the Patient Privacy Act was 2.93 on a 4-point scale; 2) the average score for the recognition of the protection of patients' personal information was 3.22 on a 4-point scale; 3) the area-based perception of the protection of patient's personal information was 3.37 points for communication, which scored highest, followed-by the linked-work area at 3.27 points, the patient's information management at 3.22 points, and the direct dental hygiene work at 3.18 points; 4) with regard to awareness of the protection of patients' personal information according to general characteristics, the perception was higher in the advanced academic year (p < 0.01), in those who had education regarding the protection of patients' personal information at both the university and the clinical practice institution (p < .05), and in those with higher grades (p < 0.01). Conclusions: Based on the above findings, the development and application of an educational program to improve awareness of the protection of patients' personal information are considered to be necessary by both universities and clinical practice institutions.

A Study on the Information Protection Intention of Digital Healthcare Service Providers (디지털 헬스케어 서비스 제공자의 정보보호의도에 관한 연구)

  • Yang, Chang-Gyu
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.17 no.4
    • /
    • pp.163-172
    • /
    • 2022
  • This study investigates the IPI (Information Protection Intention) of DHS (Digital Healthcare Service) providers by introducing PMT (Protection Motivation Theory). This study examines the effects of protection motivation, such as threat appraisal and coping appraisal, on IPI, such as ICI(Induction Control Intention) and SDI(Self Defense Intention). The research model, based on the PMT, adopted severity, vulnerability, reaction efficacy and self-efficacy as independent variables. The research model was validated through quantitative research, a survey of 222 DHS providers in South Korea, using structural equation modeling. The results show that (1) a clear awareness of the consequences of security threats increases the understanding of DHS providers on the severity of closure of healthcare information, and thus may decreases abuse of DHS by providers; (2) user confidence and satisfaction on the security system may make them be confident that they can handle the closure of healthcare information by themselves; and (3) although DHS providers are realizing the consequences of closure of healthcare information, they think that they are unlikely to encounter such situations. As a result of this study, venture companies that provide DHS need to provide contents that can continuously increase providers' security level in order to increase providers' information protection intention. It suggests that IPI is important through trust of healthcare service providers.

Corrections of Self-Absorption Effect Using the Monte Carlo Method in the Radioactivity Analysis of Environmental Samples (환경시료의 방사능 분석에서 Monte Carlo 방법을 이용한 자체흡수 효과 보정)

  • Seo, Bum-Kyoung;Lee, Dae-Won;Lee, Kil-Yong;Yoon, Yoon-Yeol;Yang, Tae-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.51-58
    • /
    • 2001
  • In the low level radioactivity measurement, such as environmental radioactivity, there were used commonly cylindrical and Marinelli type beakers by means of measurement container. If there are differences in the matrix density or sample height between standard source and sample, it must be determined full energy peak efficiency considering self absorption effect. In this paper, we compared measured efficiency with calculated full energy peak efficiencies in the HPGe detector using the Monte Carlo method. For cylindrical container, we calculated the variation of the efficiency with sample height. Also, we calculated the variation of the detection efficiency with apparent density in the cylindrical and Marinelli container. It was seen that it need to be corrected for self absorption in the energy range of below 1000keV. Also, in order to verify the validity of calculation, we compared the calculated value with reference value using NIST SRM 4353 reference soil.

  • PDF

Quality and Long-tern Aged Healing Properties of Self-healing Surface Protection Materials Using Solid Capsules (고상캡슐을 활용한 자기치유 표면보호재의 품질 및 장기재령 치유특성)

  • Oh, Sung-Rok;Nam, Eun-Joon;Kang, Shin-Taeg;Choi, Yun-Wang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.397-404
    • /
    • 2021
  • In this study, it was reviewed that the effect of solid capsules on the quality of surface repair materials and the healing properties of long-term aging, as part of a study to utilize self-healing surface repair materials using solid capsules as repair materials. As a result of evaluation of the rheological properties of self-healing surface repair materials according to the mixing of solid capsules, plastic viscosity, yield stress, and table flow tended to decrease. In the case of compressive strength, 1MPa per 1% of the solid capsule decreased proportionally. As a result of evaluating the long-term healing properties, when 10% of solid capsules were mixed, a healing rate of 90% was shown at 28 days of healing, because the solid capsule was preserved even after 91 days of age had elapsed. after 91 days of healing, even in the case of 5% of solid capsules, a healing rate of 90% was shown.

Hospital Employees' Knowledge, Recognition and Practice on the Protection of Personal Information (개인정보 보호에 대한 의료기관 종사자들의 지식, 인식과 실천)

  • Jeong, Ji-Na;Moon, Inn-Oh
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.21 no.1
    • /
    • pp.1-13
    • /
    • 2015
  • The aim of this study was to investigate hospital employees' knowledge, recognition and practice on the protection of personal information. A total of 250 hospital employees were selected using convenient sampling in J province. The data were collected using self-reported questionnaire and were analyzed using SPSS 18.0 program and descriptive statistics, Chi-squire test, t-test, ANOVA, and Pearson correlation coefficients. Average score for knowledge, recognition and practice were significantly associated with gender, education, hospital size and there was a correlation among knowledge, recognition and practice. The results of this study will help to develop education program on the protection of personal information for hospital employees.

  • PDF

Structural Safety Analysis of Newly Developed Roof-Typed Falling Rock Protection System (루프형 낙석방지안전시설의 구조적 안전성 검토 연구)

  • Park, Cheol-U;Lee, Hak-Yong
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.50
    • /
    • pp.84-96
    • /
    • 2009
  • Road is typically constructed along ridge area of mountain because of topographical and economic reasons. Therefore, road may face lots of open cut slope which can easily cause rock falling. This study evaluates the structural safety of newly developed falling rock protection system which has a roof deck plate. The structural performance under self-weight, snow load and load from failing rock was investigated using a finite element numerical analysis method. From the analysis results, the H-beam space was limited not to exceed 2.2m. The deck plate was also safe under the examined loading condition. A hinge and connection in the system were investigated through detailed modelling and analysis. The results showed that the hinge was safe enough and that the connection should strengthened with appropriate stiffeners.

  • PDF

Analysis of Catenary impedance characteristics in the extended power feeding conditions of AC traction system (교류급전방식에서의 연장급전에 따른 선로임피던스 특성 분석)

  • Jung, Hosung;Kim, Joorak;Chang, Sanghoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1617-1618
    • /
    • 2015
  • This paper analyzed catenary impedance characteristics of relays installed in substation and sectioning post to protect power feeding circuit in the extended power feeding conditions. For this, we modelled AT feeding system using PSCAD/EMTDC and calculated catenary impedance. The relay installed in substation calculated catenary impedance of the extended power feeding area adding catenary impedance of self protection zone. But, the relay installed in sectioning post calculated catenary impedance of the only protection area. Therefore, we confirmed that the more reliable protection way can be utilized using the relay installed in sectioning post.

  • PDF