• Title/Summary/Keyword: Selenium characteristic

Search Result 18, Processing Time 0.021 seconds

The X-ray Detection and morphology Characteristics on Evaporation Temperature of amorphous Selenium based digital X-ray detector (비정질 셀레늄의 박막 제조공정에 따른 미세구조와 IV특성)

  • Gong, H.G.;Cha, B.Y.;Lee, G.H.;Kim, J.H.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.51-54
    • /
    • 2002
  • Recently, due to its better photosensitivity in X-ray, the amorphous selenium based photoreceptor is used on digital direct method conversion material. Compared to other photoconductive material, amorphous selenium has good X-ray response characteristic and low leakage current. It has many parameters of detecting X-ray response on selenium. Among of them, it is well known that manufacture of a-Se is the most basic element. In this paper, we fabricated two types of amorphous selenium sample which had time variable. The one was fabricated continuous deposition sample and the other was step by step sample. Thickness of sample was $300{\mu}m$ and top electrode was evaporated gold. We investigated the leakage current and photo current of them and analysed their electrical characteristics. For analyzing morphology of samples, SEM and surface was pictured. We found that step by step deposition method could be applied for novel fabricating amorphous selenium film.

  • PDF

Zinc Sulfide-selenium X-ray Detector for Digital Radiography

  • Park, Ji-Koon;Kang, Sang-Sik;Kim, Jae-Hyung;Mun, Chi-Woong;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.16-20
    • /
    • 2002
  • The high bias voltage associated with the thick layer (typically 500-1000 ㎛) of selenium required to have an acceptable x-ray absorption in radiography and fluoroscopy applications may have some practical inconvenience. A hybrid x-ray detector with zinc sulfide-amorphous selenium structure has been developed to improve the x-ray sensitivity of a a-Se based flat-panel digital imaging detector. Photoluminescence(PL) characteristic of a ZnS:Ag phosphor layer showed a light emission peak centered at about 450 nm, which matches the sensitivity spectrum of selenium. The dark current of the hybrid detector showed similar characteristics with that of a a-Se detector. The x-ray sensitivity of hybrid and a-Se x-ray detector was 345 pC/㎠/mR and 295 pC/㎠/mR at an applied voltage of 10 V/㎛, respectively. The purpose of this study was to evaluate the pertinence of a solution using a thin selenium layer, as a photosensitive converter, with a thick coating of silver doped zinc sulfide phosphor.

A Structural characteristic of a Se thin film along substrate temperature change (기판온도 변화에 따른 Se 박막의 구조적 특성)

  • Baek, Su-Ung;Yang, Hyeon-Hun;Han, Chang-Jun;Kim, Han-Wool;Na, Kil-Ju;Lee, Suk-Ho;Chung, Hae-Deok;Park, Gye-Choon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.92.2-92.2
    • /
    • 2010
  • Selenium 물질은 지구상에 많은 양이 존재하고, 가격이 저렴하다. 그 성질은 분광감도가 시감도에 잘 일치하고, 광학적 특성이 뛰어나서 태양전지로 연구도 활발히 진행 중이다. 본 연구에서는 Se박막을 열저항증착방법을 이용하여 증착시, 기판온도를 변화를 시켜 그 구조적특성의 변화를 관찰하였다. $50^{\circ}C$에서 변화를 시작하여 $70^{\circ}C$, $100^{\circ}C$의 변화에서 각각 단사정계, 육방정계 결정구조가 나타났다. XRD 분석결과 $100^{\circ}C$에서 증착한 sample의 회절강도가 $70^{\circ}C$에서 증착한 sample보다 작은회절강도를 나타내었다. 추후 열처리공정등을 통하여 보완하면, CISe 박막 화합물 태양전지 연구에 큰 효과를 나타낼 수 있을 것으로 예상된다.

  • PDF

The characteristic study of hybrid X-ray detector using ZnS:Ag phosphor (ZnS:Ag phosphor를 이용한 hybrid 형 X-ray detector 특성 연구)

  • Park, Ji-Koon;Gang, Sang-Sik;Lee, Dong-Gil;Cha, Byeong-Yeol;Nam, Sang-Hee;Choi, Heung-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.27-30
    • /
    • 2002
  • Photoconductor for direct detection flat-panel imager present a great materials challenge, since their requirements include high X -ray absorption, ionization and charge collection, low leakage current and large area deposition. Selenium is practical material. But it needs high thickness and high voltage in selenium for high ionization rate. We report comparative studies of detector sensitivity. One is an a-Se with $70{\mu}m$ thickness on glass. The other has hybrid layer of depositting ZnS phosphor with $100{\mu}m$ on a-Se. The leakage current of hybrid is similar to it of a-Se, but photocurrent is lager than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF

The Multi-layer Fabrication and Characteristic Performance for Dark Current Reduction of Amorphous Selenium (비정질 셀레늄의 누설전류 저감을 위한 다층구조 제작 및 특성 평가)

  • Park, J.K.;Kang, S.S.;Suk, D.W.;Lee, H.W.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.849-852
    • /
    • 2002
  • Recently, amorphous selenium is used as x-ray conversion material for flat-panel x-ray detector. In this paper, we investigated the effect of breakdown under high voltage and leakage current in PN-type multi-layer structure based on p-type a-Se and n-type conductive thin film. Experimental results show that the multi-layer based detector reduced leakage current because n-type CeO2 conductive layer prevent from hole injection into a-Se layer from collection electrode, Also, the breakdown voltage was improved by dielectric layer between a-Se and top electrode.

  • PDF

Characteristic Study of X-ray convert material by Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 X선 변환물질의 특성 연구)

  • Kim, Jin-Young;Park, Ji-Koon;Kang, Sang-Sik;Kim, So-Young;Jung, Eun-Sun;Nam, Sang-Hee;Kang, Sin-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.418-421
    • /
    • 2003
  • Today, much terminologies such as noise spectrum, Sharpness, contrast, MTF had been defined for Image quality revaluation of radiation Image. Since development of Xeroradiography In the 1970s, Digital radiation detector that use amorphous selenium was developed. The aim of this research is to analyze physical phenomenon of digital radiation detector that use amorphous selenium. Result of Monte Carlo simulations on amorphous selenium based on physical properties(creation of electron-hole pairs) by induced x-ray are described. From the simulation, intrinsic point spread function(PSF) was found and used to observe modulation transfer function(MTF). We investigated how PSF and MTF changed with various x-ray energy. This result can be used to design digital x-ray detector based on a-Se.

  • PDF

Effects of Zn-L-Selenomethionine on Carcass Composition, Meat Characteristics, Fatty Acid Composition, Glutathione Peroxidase Activity, and Ribonucleotide Content in Broiler Chickens

  • Chaosap, Chanporn;Sivapirunthep, Panneepa;Takeungwongtrakul, Sirima;Zulkifli, Razauden Mohamed;Sazili, Awis Qurni
    • Food Science of Animal Resources
    • /
    • v.40 no.3
    • /
    • pp.338-349
    • /
    • 2020
  • The effects of organic Zn-L-selenomethionine (Zn-L-SeMet) at 0.3 ppm on carcass composition, meat characteristics, fatty acid composition, glutathione peroxidase activity, and ribonucleotide content were compared against the commercial inorganic sodium selenite (Na-Se) and the combination of the two, in commercial broilers. A total of 540 one day-old chicks were assigned at random to 3 dietary treatments : i) commercial inorganic selenium as control or T1, ii) a 1:1 ratio of inorganic and organic selenium as T2, and iii) organic selenium as T3. Carcass composition, meat characteristics, cholesterol content, fatty acid composition, and ribonucleotide content were generally unaffected by treatments. However, discrepancy were significantly observed in glutathione peroxidase activity (GSH-Px) and water holding capacity, with organic selenium showing higher glutathione peroxidase activity (p<0.01) and lower shrinkage loss (p<0.05), respectively. These findings could be explained by the contribution of organic selenium in bioavailability of GSH-Px. However, having conducted in a commercial close house system with sufficient amount of nutritional supplementation, the present study demonstrated little or no effects of organic Zn-L-SeMet on meat characteristics, fatty acid composition, and ribonucleotide content (flavor characteristic) in broiler chickens.

The Study on X-ray Detection Characteristics of Radiation Detective Sensor with Changing Composition Ratio of Iodine in a-Se (a-Se에 첨가된 Iodine의 조성비 변화에 따른 X선 검출특성 연구)

  • Cha, Byung-Youl;Kang, Sang-Sik;Lee, Gyu-Hong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.399-402
    • /
    • 2002
  • This paper is researched that electric characteristic of Digital x-ray radiography technique with changing composition ratio of Iodine. Dopant material, Iodine is evaporated with amorphous selenium. Thorugh the old papers say, doponted Iodine will be down the created trap level because of Arsenic dopant material in amorphous selenium. Arsenic material of Composition ratio in amorphous selenium is fixed with 0.3% and test sample is deposited composition of 30, 100, 300, 500, 700ppm with thermal evaporate system. Experimental measurement is performed by dark current and x-ray sensitivity in amorphous selenium based radition detector sensor. Fabricated test sample thickness is $30{\mu}m$ and injected voltage is $3{\mu}m$$6{\mu}m$$9{\mu}m$ to both electrode. Experimental results showed that the net charge of composition rate of 30ppm is 398.88 pc/mR/$cm^2$ very high. And increase of the Iodine composition ratio is tendency to the decrease of net charge. Doping changing composition of Iodine in amorphous selenium detector offered to basical information of amorphous selenium material.

  • PDF

Effects of Organic Selenium Mix on the Performance, Carcass Characteristics, Tissue Selenium Distribution, and Economic Value in Finishing Hanwoo Steers (유기셀레늄 혼합제 급여가 비육말기 거세한우의 성장, 도체성적, 체내 셀레늄 분포 및 경제성에 미치는 영향)

  • Kim, D.K.;Jung, D.U.;Sung, H.G.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.6
    • /
    • pp.975-984
    • /
    • 2005
  • This study fulfilled to investigate the feed efficiency, tissue selenium distribution, carcass characteristic and economic value in finishing Hanwoo steers fed organic selenium mix (OSM) which included seleno-yeast, rumen culture and other microbial supplements. Forty five finishing Hanwoo steers were tested for 4 months dividing to three feeding groups: OSM add as 0.5 ppm Se of DM feeds (0.5 ppm OSM), OSM enriched add as 1.0 ppm Se of DM feeds (1.0 ppm OSM) and basal diet without OSM (control). The total weight gains, the average daily gains and the feed intakes were not differ in treatments (p > 0.05). No differences (p > 0.05) were noted for hot carcass weight, loin eye area, backfat thickness, meat yield index, meat color, fat color, tenderness and maturity. However, the 1.0 ppm OSM showed better performances for feed requirement, TDN per gain, meat yield grade and meat quality grade compared to other groups. Tissue selenium distribution was increased by organic selenium feeding: higher Se concentration in liver and rump of 0.5 ppm OSM (p < 0.05), and kidney, liver, sirloin and rump of 1.0 ppm OSM (p < 0.05) than the tissues of control group. Generally, tissue selenium was the highest value in 1.0 ppm OSM and showed higher concentrate in order; kidney, liver, sirloin and rump. The income over feed cost was 1.06-fold higher in 1.0 ppm OSM than control group. In conclusion, organic selenium mix supplementation and its amounts were not influenced to feed intake, body gain and carcass characteristic but significantly increased tissue selenium. Therefore, these results suggest that finishing Hanwoo steer fed an enriched organic selenium mix with proper probiotics is able to produce “high-Se” beef as high bioavailable form as well as create a beneficial opportunity on Hanwoo farm.

optical gain and output characteristic of selenium vapour multiline laser on purity of helium (셀레늄증기 다중광선레이저의 헬륨 순도에 따른 광이득과 출력특성)

  • 최상태
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.60-65
    • /
    • 2002
  • The purpose of this study is to measure and compare the output power characteristics and optical gain for selenium vapour laser depending on the He gas purity. The purity of the He gas was improved with a special He-filter. During the measurement the individual wavelengths were selected with a birefringent filter. The result shows that compared with those of laser without He-filter, the output-coupling power and small signal gain of laser with He-filter increase in the most of the lines. Especially, the output-coupling power and small signal gain for the strong lines (497.6 nm, 499.3 nm, 506.9 nm, 517.6 nm, 522.8 nm, 530.5 nm), blue(460.4 nm, 464.8 nm) and red(644.4 nm 649.1 nm) lines lies notably higher.