• Title/Summary/Keyword: Selectivity filter

Search Result 86, Processing Time 0.031 seconds

A Study on the Design of Elliptic-Function Narrow-Band Bandpass Filters for Tx RF of the IMT-2000 Mobile Equipment (IMT-2000 단말기의 Tx RF용 타원행 협대역 대역통과 필터의 설계에 관한 연구)

  • Lee, Sang Won;Chung, Myung-Rae;Kim, Hak-Sun;Hong, Shin-Nam
    • Journal of Advanced Navigation Technology
    • /
    • v.5 no.2
    • /
    • pp.141-148
    • /
    • 2001
  • This paper describe the development of narrow-band passband filter with small package and low loss, high selectivity performance. This filter is placed between power amplifier and frequency mixer of IMT-2000 mobile equipment. The elliptic-function narrow-band passband filter is designed with new architecture using the microstrip line. This package is very small by $3.2cm{\times}1.25cm$ and have the 3 % 3 dB bandwidth. Also in the passband the insertion loss is about 2.5 dB and is better than older RF SAW filter(insertion loss: 3.2 dB). In the stop-band it has the two deep notch under the -56 dB.

  • PDF

Design and Fabrication of a LTCC Diplexer for GSM/CDMA Applications (GSM/CDMA 대역용 LTCC Diplexer설계 및 제작)

  • Kim, Tae-Wan;Lee, Young-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1267-1271
    • /
    • 2009
  • In this paper, a diplexer circuit to separate GSM from CDMA band is designed using a LTCC (Low Temperature Cofired Ceramic) multi-layer technology. In order to increase a integration capability of the diplexer, it is designed using 3-dimensional (3-D) multi-layer compact inductor and capacitors in e-layer LTCC substrate with a relative dielectric constant of 7. In order to achieve high selectivity of the bands, a shunt capacitor and inductor are designed in the high-pass filter (HPF) and low-pass filter (LPF), respectively. The size of the fabricated diplexer including CPW pads is 3,450 ${\times}$4,000 ${\times}$694 ${\mu}m^3$An insertion loss (IL) and return loss in GSM band are less than -1.35dB and more than -5.66dB,respectively. In the case of CDMA band, the IL of -1.54dBandRLof above -9.30dBare archived.

Design of Microstrip Band-Pass filters Using Cross-Coupled Hairpin Resonators (교차결합 헤어핀 공진기를 이용한 마이크로스트립 대역통과 여파기 설계)

  • 오창근;전성근;이문수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.3
    • /
    • pp.557-564
    • /
    • 2000
  • A microstrip band-pass filter using cross-coupled resonators is designed and studied experimentally. The cross-coupled microstrip hairpin resonator filters exhibit ripples in both passband and stopband. These ripples can improve both frequency selectivity and insertion loss. The cross-coupled filters are not only simple and compact in configuration, but also have great flexibility to form filters into a variety of size. In this paper, a microstrip band-pass filter using cross-coupled resonators is designed at the center frequency of 1.8GHz with bandwidth of 5.0% using Ensemble software. The experimental results show that the bandwidth is about 4.53% at 1.8GHz.

  • PDF

Selective Adsorption Properties of Carbonyl Compounds in Cigarette Mainstream Smoke by Hydrazine Impregnated Adsorbent (Hydrazine 첨착 흡착제에 의한 담배 주류연 중 카보닐 화합물의 선택 흡착 특성)

  • Park Jin-Won;Rhee Moon-Soo;Lee John-Tae;Hwang Keon-Joong;Hwang Taek-Sung
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.2
    • /
    • pp.178-188
    • /
    • 2005
  • To use the filter materials for selective removal of carbonyl compounds in cigarette mainstream smoke, hydrazine such as 2,4-dinitrophenylhydrazine and dansylhydraznie impregnated adsorbents were prepared with perchloric acid or phosphoric acid as a accelerator in hydrazone formation reaction. The change of morphology of adsorbents in various of impregnator were investigated by SEM. Impregnation amount caused by reaction time, acid type and impregnation reagent, and the adsorption properties of carbonyl compounds in cigarette mainstream smoke were investigated. Amounts of impregnation was increased as increasing reaction time. The removal amount for vapor phase carbonyl compounds by 2,4-DNPH impregnated adsorbent was higher than that of dansylhydrazine impregnated adsorbent. The selectivity of 2,4-DNPH impregnated polyacrylic type adsorbent was superior to those of other adsorbents. This results indicated that the 2,4-DNPH impregnated polyacrylic adsorbent was applicable to cigarette filter material because of its fast reactivity and porosity.

A Study on the Design and Fabrication of RF Receiver Module for IMT-2000 Handset (IMT-2000단말기용 RF 수신모듈 설계 및 제작에 관한 연구)

  • 이규복;송희석;박종철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.19-25
    • /
    • 2000
  • In this paper, we describe RF receiver module for IMT-2000 handset with 5 MHz channel bandwidth. The fabricated RF receiver module consists of Low Noise Amplifier, RF SAW filter, Down-converter, If SAW filter, AGC and PLL Synthesizer. The NF and IIP3 of LNA is 0.8 dB, 3 dBm at 2.14 GHz, conversion gain of down-converter is 10 dB, dynamic range of AGC is 80 dB, and phase noise of PLL is -100 dBc at 100 kHz. The receiver sensitivity is -110 dBm, adjacent channel selectivity is 48 dBm.

  • PDF

The Effect of $MnO_2$ Addition on the $V_2O_5/TiO_2$ Catalytic Filters for NO Reduction (NO 환원반응을 위한 $V_2O_5/TiO_2$계 촉매필터의 $MnO_2$ 조촉매 효과)

  • Shin, Hae-Joong;Choi, Jae-Ho;Song, Young-Hwan;Lee, Ju-Young;Jang, Sung-Cheol;Choi, Joo-Hong
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.363-368
    • /
    • 2008
  • Nitrogen oxides (NO, $NO_2$ and $N_2O$) have been controlled effectively by the SCR catalysts coated on monolith or honeycomb in commercial sites with ammonia as reductant at high temperature range $300{\sim}400^{\circ}C$. However, the catalytic filter has much merit on the point of controlling the particles and nitrogen oxides simultaneously. It will be more advanced-system if the catalytic working temperature is reduced to the normal filtration temperature of under $200^{\circ}C$. This study has focus on the development of the catalytic filter working at the low temperature. So the additive effect of the components such as Pt and Mn (which are known the catalytic component of $V_2O_5/TiO_2$ was investigated. The $V_2O_5-WO_3$ catalytic filter exhibited high activity and selectivity at $250{\sim}320^{\circ}C$ showing more than 95% NO conversion for the treatment of 600 ppm NO at face velocity 2 cm/s. The Pt-$V_2O_5-WO_3$ catalytic filter shifted the optimum working temperature towards the lower temperature ($170{\sim}200^{\circ}C$). And NO conversion was 100% and higher than that of $V_2O_5-WO_3$ catalyst at $250{\sim}320^{\circ}C$. The $MnO_X-V_2O_5-WO_3$ catalytic filter showed the wide temperature range of $220{\sim}330^{\circ}C$ for more than 95% NO conversion. This is a remarkable advantage when considered the $MnO_X$ catalytic filter presents the maximum activity at $150{\sim}250^{\circ}C$ and $V_2O_5-WO_3$ catalytic filter shows the maximum activity at $250{\sim}320^{\circ}C$.

  • PDF

Measurement of Leukocyte Motions in a Microvessel Using Spatiotemporal Image Analysis

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.315-319
    • /
    • 2008
  • This paper describes a method for recognizing and measuring the motion of each individual leukocyte in microvessel from a sequence of images. A spatiotemporal image is generated whose spatial axes are parallel and vertical to vessel region contours. In order to enhance and extract only leukocyte traces with a turned velocity range even under noisy background, we use a combination of a filtering process using Gabor filters with sharp orientation selectivity and a subsequent 3D spatiotemporal grouping process. The proposed method is shown to be effective by experiments using image sequences of two kinds of microcirculation, rat mesentery microvessels and human retinal capillaries.

A Fabrication of IR $CO_2$ Sensor based on the MEMS and Characteristic Evaluation (MEMS 기반의 IR $CO_2$ 센서 제작 및 특성 평가)

  • Kim Shin-Keun;Han Yong-Hee;Moon Sung-Wook
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.232-237
    • /
    • 2005
  • In this paper, we fabricated $CO_2$ gas sensor based on the MEMS infrared sensor and characterized its electrical and $CO_2$-sensing properties. The fabricated $CO_2$ gas sensor by MEMS technique has many advanges over NDIR(nondispersive) $CO_2$ sensor such as monolithic fabrication, very high selectivity on $CO_2$, low power consumption and compact system. Microbolometer by surface micromachining was fabricated for gas detector and $CO_2$ filter chip by bulk micromachining was fabricated for signal referencing. By using the proposed and fabricated gas sensor, we are expected to measure $CO_2$ concentration more accurately with high reliability.

Development of an Externally Amplitude-and-Delay Equalized Narrow-Bandpass Filter for the Engineering Model Level Ka-band Input Demultiplexer (Engineering Model 급 Ka 대역 입력 Demultiplexer 용의 진폭 및 군지연 등화된 협대역 여파기의 개발)

  • 강승택;엄만석;이주섭;염인복;이성팔
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.347-351
    • /
    • 2002
  • 본 논문에서는, 위성 중계기 Engineering Model(EM)급 Ka 대역 입력 Demultiplexer (IMUX)의 진폭 및 군지연 등화된 채널 협대역 여파기의 개발/결과가 제시된다. 여파기는 큰 선택성(selectivity)과 작은 대역내 손실로써 동작하기 위해, 8차의 타원적분형 응답특성의 이중모드 결합구조의 특성을 가진다. 그리고 여파기 출력이 가지는 급한 변화의 군지연과 대역내 진폭은 2극(Pole) 등화기에 의해 평탄하게 된다. 튜닝 및 측정 결과는 요구규격사항을 잘 만족함을 보여준다.

  • PDF

Gabor Filter-based Feature Extraction for Human Activity Recognition (인간의 활동 인정 가보 필터 기반의 특징 추출)

  • AnhTu, Nguyen;Lee, Young-Koo;Lee, Sung-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06c
    • /
    • pp.429-432
    • /
    • 2011
  • Recognizing human activities from image sequences is an active area of research in computer vision. Most of the previous work on activity recognition focuses on recognition from a single view and ignores the issue of view invariance. In this paper, we present an independent Gabor features (IGFs) method comes from the derivation of independent Gabor features in the feature extraction stage. The Gabor transformed human image exhibit strong characteristics of spatial locality, scale and orientation selectivity.