• Title/Summary/Keyword: Selective testing

Search Result 60, Processing Time 0.024 seconds

A Hybrid Shadow Testing Scheme During Ray Tracing (광선추적 수행중 혼합 음영검사에 관한 연구)

  • Eo, Kil-Su;Kyung, Chong-Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.3
    • /
    • pp.95-104
    • /
    • 1989
  • This paper presents a new shadow testing acceleration scheme for ray tracing called Hybrid Shadow Testing (HST) based on a conditional switching between the conventinal shadow testing method and Crow's shadow volume method, where the shadow polygons as well as the object polygons are registered onto the corresponding cells under the 3-D space subdivision environment. Despite the preprocessing time for the generation and registration of the shadow polygons, the total shadow testing time of the proposed algorithm, HST was approximately 50% of that of the conventional shadow testing method for several examples while the total ray tracing time was typically reduced by 30% from the conventional approach. This due to the selective use of the shadow volume method with a compromise between the maximal utilisation of shadow's spatial coherency and minimising the computational overhead for checking ray intersections with the shadow polygons. A parameter, $N_{th}$ denoting the critical number of shadow polygons between successive reflection points was used as a guideline for switching the shadow testing scheme between the conventional method and shadow volume method. A method for calculating $N_{th}$ from such statistical data as the number of object polygons, average polygon size average peripheral length of the polygons was proposed, resulting in good agreement with the experimental results.

  • PDF

Magnetic field distribution in steel objects with different properties of hardened layer

  • Byzov, A.V.;Ksenofontov, D.G.;Kostin, V.N.;Vasilenko, O.N.
    • Advances in Computational Design
    • /
    • v.7 no.1
    • /
    • pp.57-68
    • /
    • 2022
  • A simulation study of the distribution of magnetic flux induced by a U-shaped electromagnet into a two-layer massive object with variations in the depth and properties of the surface layer has been carried out. It has been established that the hardened surface layer "pushes" the magnetic flux into the bulk of the magnetized object and the magnetic flux penetration depth monotonically increases with increasing thickness of the hardened layer. A change in the thickness and magnetic properties of the surface layer leads to a redistribution of magnetic fluxes passing between the poles of the electromagnet along with the layer and the bulk of the steel object. In this case, the change in the layer thickness significantly affects the magnitude of the tangential component of the field on the surface of the object in the interpolar space, and the change in the properties of the layer affects the magnitude of the magnetic flux in the magnetic "transducer-object" circuit. This difference in magnetic parameters can be used for selective testing of the surface hardening quality. It has been shown that the hardened layer pushes the magnetic flux into the depth of the magnetized object. The nominal depth of penetration of the flow monotonically increases with an increase in the thickness of the hardened layer.

Evaluation of Reliability for Welded thick steel joint (후판 강용접부의 신뢰성 평가)

  • 최원두;이영호;길두송;박상기
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.327-329
    • /
    • 2004
  • Reliability evaluation of the welded structure for industrial structures/facilities such as power plant and petro-chemical refinery facilities is very important, and especially the reliability diagnosis of the structure is based on the exact evaluation of materials properties. But, the conventional Pre-Qualification test had the difficulty of evaluating the real material properties in the field because the test was made on the specimen with the simulated welding for the in-field welding condition. Therefore, a continuous indentation technique was proposed for simple and non-destructive testing of in-field structures and for selective testing of local range such as heat affected zone and weldment.

  • PDF

A Dynamic Approach to Estimate Change Impact using Type of Change Propagation

  • Gupta, Chetna;Singh, Yogesh;Chauhan, Durg Singh
    • Journal of Information Processing Systems
    • /
    • v.6 no.4
    • /
    • pp.597-608
    • /
    • 2010
  • Software evolution is an ongoing process carried out with the aim of extending base applications either for adding new functionalities or for adapting software to changing environments. This brings about the need for estimating and determining the overall impact of changes to a software system. In the last few decades many such change/impact analysis techniques have been developed to identify consequences of making changes to software systems. In this paper we propose a new approach of estimating change/impact analysis by classifying change based on type of change classification e.g. (a) nature and (b) extent of change propagation. The impact set produced consists of two dimensions of information: (a) statements affected by change propagation and (b) percentage i.e. statements affected in each category and involving the overall system. We also propose an algorithm for classifying the type of change. To establish confidence in effectiveness and efficiency we illustrate this technique with the help of an example. Results of our analysis are promising towards achieving the aim of the proposed endeavor to enhance change classification. The proposed dynamic technique for estimating impact sets and their percentage of impact will help software maintainers in performing selective regression testing by analyzing impact sets regarding the nature of change and change dependency.

Performance evaluation of nitrate removal in high TDS wet scrubber wastewater by ion exchange resin with dissolved air flotation (DAF) process

  • Kim, Bongchul;Yeo, Inseol;Park, Chan-gyu
    • Membrane and Water Treatment
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • The regulations of the International Maritime Organization (IMO) have been steadily strengthened in ship emissions. Accordingly, there is a growing need for development of related technologies for the removal of contaminants that may occur during the treatment of SOx and NOx using a wet scrubber. However, this system also leads to wastewater production when the exhaust gas is scrubbed. In this research, we evaluated the performance of an ion selective resin process in accordance with scrubber wastewater discharge regulations, specifically nitrate discharge, by the IMO. Accelerated real and synthetic wastewater of wet scrubbers, contained high amounts of TDS with high nitrate, is used as feed water in lab scale systems. Furthermore, a pilot scale dissolved air flotation (DAF) using microbubble generator with ion exchange resin process was combined and developed in order to apply for the treatment of wet scrubber wastewater. The results of the present study revealed that operating conditions, such as resin property, bed volume (BV), and inlet wastewater flow rate, significantly affect the removal performance. Finally, through a pilot test, DAF with ion exchange resin process showed a noticeable improvement of the nitrate removal rate compared to the single DAF process.

Comparison of In-Field Measurements of Nitrogen and Other Soil Properties with Core Samples (코어샘플을 이용한 질소 등 토양성분 현장 측정방법의 비교평가)

  • Kweon, Gi-Young;Lund, Eric;Maxton, Chase;Kenton, Dreiling
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.96-108
    • /
    • 2011
  • Several methods of in-field measurements of Nitrogen and other soil properties using cores extracted by a hydraulic soil sampler were evaluated. A prototype core scanner was built to accommodate Veris Technologies commercial Vis-NIRS equipment. The testing result for pH, P and Mg were close to RPD (Ratio of Prediction to Deviation = Standard deviation/RMSE) of 2, however the scanner could not achieve the goal of RPD of 2 on some other properties, especially on nitrate nitrogen ($NO_3$) and potassium (K). In situ NIRS/EC probe showed similar results to the core scanner; pH, P and Mg were close to RPD of 2, while $NO_3$ and K were RPD of 1.5 and 1.2, respectively. Correlations between estimations using the probe and the core scanner were strong, with $r^2$ > 0.7 for P, Mg, Total N, Total C and CEC. Preliminary results for mid-IR spectroscopy showed an $r^2$ of 0.068 and an RMSE for nitrate (N) of 18 ppm, even after the removal of calcareous samples and possible N outlier. After removal of calcareous samples on a larger sample set, results improved considerably with an $r^2$ of 0.64 and RMSE of 6 ppm. However, this was only possible after carbonate samples were detected and eliminated, which would not be feasible under in-field measurements. Testing of $NO_3$ and K ion-selective electrodes (ISEs) revealed promising results, with acceptable errors measuring soil solutions containing nitrate and potassium levels that are typical of production agriculture fields.

A Study on Safety, Performance and Clinical effectiveness Test Guideline of Versatile Ophthalmic Laser System (다목적 안과용 레이저 시스템 안전성 성능평가 및 임상적 유효성평가 가이드라인 수립을 위한 연구)

  • Kim, You Rim;Yu, Woo Jin;Park, Ho Joon;Jang, Won Seuk
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.250-259
    • /
    • 2019
  • Ophthalmic Laser System is widely used in Selective Laser Trabeculoplasty of Open Angle Glaucoma and Ocular Hypertension. Versatile ophthalmic laser system is a medical device with technology that checks the condition of the treatment area by irradiating a continuous laser pulse on the treatment area, and monitoring the microbubble reaction caused by the temperature increase of the melanosome through the ultrasonic signal and the optical signal sensor. It performs selective laser treatment without damaging the photoreceptor by controlling the wavelength of the laser when microbubbles are detected. This study aims to suggest a guideline for evaluating safety, performance and clinical effectiveness of Versatile Ophthalmic Laser System in accordance with the growing technology. International Standards, Regulations, and Clinical Trial Protocols were investigated and analyzed for this study. As a result of this study, the safety, performance and clinical effectiveness test guideline for Versatile Ophthalmic Laser System were proposed. This guideline will ensure the safety and efficacy of Medical device, and furthermore it is expected to be able to promote the development of technology development by supporting a clinical trial plan.

A Proposal for Optical Diagnostics Through the Enhancement of Diffraction Patterns Using Thin-film Interference Filters

  • Stefanita Carmen Gabriela;Shao Yun Feng
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.428-434
    • /
    • 2004
  • Coarse clumping of solid materials within diseased biological cells can have a marked influence on the light scattering pattern. Perturbations in refractive index lead to distinct varia­tions in the cytometric signature, especially apparent over wide scattering angles. The large dynamic range of scattering intensities restricts collection of data to narrow angular intervals be­lieved to have the highest potential for medical diagnosis. We propose the use of an interfer­ence filter to reduce the dynamic range. Selective attenuation of scattering intensity levels is expected to allow simultaneous data collection over a wide angular interval. The calculated angu­lar transmittance of a commercial shortwave-pass filter of cut-off wavelength 580 nm indicates significant attenuation of scattering peaks below ${\~}\;10^{circ}$, and reasonable peak equalization at higher angles. For the three-dimensional calculation of laser light scattered by cells we use a spectral method code that models cells as spatially varying dielectrics, stationary in time. How­ever, we perform preliminary experimental testing with the interference filter on polystyrene microspheres instead of biological cells. A microfluidic toolkit is used for the manipulation of the microspheres. The paper intends to illustrate the principle of a light scattering detection system incorporating an interference filter for selective attenuation of scattering peaks.

New Phenylaminopyrimidine (PAP) Anticancer Lead Compound with High Efficacy: Design, Synthesis, and in vitro Screening

  • El-Deeb, Ibrahim Mustafa;Han, Dong-Keun;Kim, In-Tae;Lee, So-Ha
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1848-1858
    • /
    • 2010
  • Phenylaminopyrimidines represent a large group of new selective anticancer agents, the majority of which exert their action through the inhibition of specific kinases. In this study, a new series of N-substituted-2-aminopyrimidines has been designed and synthesized. A selected group of the synthesized derivatives was screened at a single dose concentration of 10 ${\mu}M$ over a panel of 60 cancer cell-lines. Compound 12e has showed great inhibitory and strong lethal effect over almost all of the 60 cell-lines and accordingly was further tested in a 5-dose testing mode to determine its $IC_{50}$ values, where it showed great efficacies with intermediate potencies over the tested cell-lines. The compound was also tested over a panel of 52 kinases to explore its kinase inhibitory profile, and was found to be a selective but moderate inhibitor over FLT3 kinase.

Selective interaction testing for software (소프트웨어의 선택적 교호작용 테스팅)

  • Ko Byunggak;Lee Sanyong;Jang Jungsoon;Choi Hyunghee;Park Seung-Kyu;Chung Kihyun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11b
    • /
    • pp.382-384
    • /
    • 2005
  • 소프트웨어 테스팅에서 테스트 스위트(suite)의 수를 줄이면서도 테스트 커버리지나 오류검출에 있어서 효과적인 방법을 찾기 위한 많은 연구가 시도되어 왔다. 안정성이 높은 설계가 되도록 설계 조건을 결정하기 위하여 제어인자들의 직교 배열을 사용하는 시험방법인 교호작용 테스팅 기법이 소프트웨어의 테스트에서도 효과가 매우 높다는 것이 실험으로 증명되고 있다. 소프트웨어는 상대적으로 몇 안 되는 조건들의 조합들로 오류가 발생할 가능성이 높다는 특징을 가지고 있다. 따라서, 파라미터 간 교호작용 강도 t를 갖는 t-way 테스팅을 통해 효과적으로 테스트 스위트를 줄이면서 많은 오류를 검출할 수 있다. 그러나 t값을 증가시키면 테스트 스위트의 수가 늘어난다는 단점이 발생한다. 또한, 어떠한 파라미터들이 서로 교호작용을 일으키는 것인지 알수 없는 상황을 가정한 단순한 교호작용 테스팅은 자칫 서로 관련 없는 파라미터들도 교호작용 테스팅에 참여하기 때문에 테스트의 낭비가 있을 수 있다는 단점이 있다. 이에, 본 논문에서는 소프트웨어의 입력과 출력간의 관계를 바탕으로 시스템 I-O관계도를 작성한 후, 이를 바탕으로 각 출력에 대한 교호작용을 일으킬 수 있는 파라미터를 중심으로 테스트 스위트를 생성하는 Selective Covering Array를 제안한다.

  • PDF