• 제목/요약/키워드: Selective testing

검색결과 60건 처리시간 0.027초

DC 비접지 급전계통 선택차단형 통합보호계전기 시뮬레이터 개발 및 알고리즘 테스트 (Development of a Simulator and Algorithm Test for Selective-breaking Integrated Protective Relay for Ungrounded DC Traction Power Supply System)

  • 안태풍;윤준석;정태영;김인웅;정호성
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.899-904
    • /
    • 2012
  • In recent years, a lot of research was done for earth fault protection in ungrounded dc power supply system. As a result, selective-breaking integrated protective relaying system is developed in progress and is currently field-testing are planned. Algorithm on a PC using PSCAD done a lot of testing before performing field tests, but in this study developed algorithms and functions needed to determine whether they were operating normally. Therefore, simulated system is similar to the actual situation was required and made. selective-breaking algorithm verification and validation was performed with simulator.

차별화된 소프트웨어 시험을 위한 시험항목 우선순위 조정 (Test Item Prioritizing Metrics for a Selective Software Testing)

  • 이재기;이재정
    • 한국통신학회논문지
    • /
    • 제33권1B호
    • /
    • pp.38-47
    • /
    • 2008
  • 다양한 소프트웨어 기능들에 대해서 활발한 시장의 요구사항에 부응하기 위해서는 주어진 납기에 시스템시험을 마쳐야 한다. 특히, 사용자나 개발목표 시스템의 주요 핵심기능과 밀접한 주요 고장들은 시스템시험에서 반드시 검출, 제거되어야 한다. 대부분 제안되고 있는 시스템시험 방법은 효율적이고 가격 경쟁력을 갖춘 선택적인 시험 방법이 아닌 일상적인 방법이다. 이러한 방법들은 시스템 개발 초기나 단기간(short-term)의 효과적인 시험에 응용할 수 없으며, 새로운 기능의 추가에 따른 시험 준비에 많은 비용이 수반되므로 효과적인 시험이 되지 못한다. 이러한 문제를 극복하기 위한 새로운 시험방법으로 시험수행의 핵심적인 역할을 수행하는 선택적인 소프트웨어 시험이 필요하다. 선택적인 시험방법은 3가지 정보를 조합하여 시험항목 순위를 결정하는데 즉, 사용빈도, 시나리오 복잡도, 고장강도 등이다. 이 정보를 사용하여 시험을 수행함으로써 시스템의 치명적인 고장을 찾는데 활용함으로써 보다 효율적인 시스템 시험을 수행할 수 있다. 본 논문에서는 주요기능과 관련된 심각한 오류와 시스템의 치명적인 결함을 찾는 선택적인 소프트웨어 시험 방법에 대해 제안된 방법을 적용, 그 결과를 검증한다.

Quality Variable Prediction for Dynamic Process Based on Adaptive Principal Component Regression with Selective Integration of Multiple Local Models

  • Tian, Ying;Zhu, Yuting
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권4호
    • /
    • pp.1193-1215
    • /
    • 2021
  • The measurement of the key product quality index plays an important role in improving the production efficiency and ensuring the safety of the enterprise. Since the actual working conditions and parameters will inevitably change to some extent with time, such as drift of working point, wear of equipment and temperature change, etc., these will lead to the degradation of the quality variable prediction model. To deal with this problem, the selective integrated moving windows based principal component regression (SIMV-PCR) is proposed in this study. In the algorithm of traditional moving window, only the latest local process information is used, and the global process information will not be enough. In order to make full use of the process information contained in the past windows, a set of local models with differences are selected through hypothesis testing theory. The significance levels of both T - test and χ2 - test are used to judge whether there is identity between two local models. Then the models are integrated by Bayesian quality estimation to improve the accuracy of quality variable prediction. The effectiveness of the proposed adaptive soft measurement method is verified by a numerical example and a practical industrial process.

선택적 세로토닌 재흡수차단제들이 만성 경도 스트레스 후의 백서에서 수동적 회피학습에 미치는 영향 (Effects of Selective Serotonin Reuptake Inhibitors on the Retention of Passive Avoidance Learning after Chronic Mild Stress in Rats)

  • 이기철;장환일
    • 생물정신의학
    • /
    • 제4권2호
    • /
    • pp.237-245
    • /
    • 1997
  • The study was designed to evaluate the significant roles of SSRI in rat of depression model. Chronic exposure to mild unpredictable stress has been found to depress the consumption of sweet 1% sucrose solutions in the Sprague-Dawley rats. We applied the variety of 11 types of stress regimens and identified depressive behaviours(developed by Willner) in 70 Sprague-Dawley rats. Rats in experiments were stratified into 6 groups, ie ; 3 kinds of SSRI(paroxetine, fluoxetine, sertraline), clomipramine, choline and saline control. Memory function was evaluated by passive avoidance learning and retention test. The authors determined how long memory retention would remain improved with 24 hour, 1 week, 2 weeks, 3 weeks, and 4 weeks at training-testing interval in depressive states of the Sprague-Dawley rats. The results were as follows ; 1) There were no significant differences between the 6 groups at the 24 hour training-testing interval. 2) The paroxetine treated group showed significant differences from the control group at the 1 week and 2 weeks training-testing interval. 3) The paroxetine and the fluoxetine treated groups showed singificant differences from the control group at 3 week training-testing interval. 4) The paroxetine and the choline treated groups showed significant differences from the control group at 4 week training-testing interval. In summary, paroxetine had an effect on long term memory processing from 1st week to 4th week. Also, fluoxetine(at 3rd week) and choline(at 4th week) had effect on long term memory processing. Sertraline, clomipramine were ineffective on memory processing during 4 weeks observation. Possible explanations why paroxetine had early effect on memory processing than the other selective serotonin reuptake inhibitors are rapid bioavailability, which is the characteristics of pharmacokinetics of paroxetine. In clinical situation, author carefully suggest that SSRI would be beneficial to improve the memory function caused by depressive neurochemical changes.

  • PDF

SLS에 의한 PCL/TCP 복합체 제작공정변수의 최적화 (Processing Optimization of PCL/TCP Composites Produced by Selective Laser Sintering)

  • 정하승;지해성
    • 한국CDE학회논문집
    • /
    • 제13권6호
    • /
    • pp.421-428
    • /
    • 2008
  • This article investigates the fabrication of polycaprolactone (PCL) composites filled with different volume fractions (10-30%) of tricalcium phosphate (TCP) by selective laser sintering (SLS) for tissue engineering scaffolds. Optimal processing parameters for each composition were developed by design of experiments (DOE). Specimens for compressive testing for each composition were fabricated and tested. The results showed that the compressive modulus increases as a function of TCP volume fraction. The experimentally measured compressive moduli were compared with moduli predicted by Halpin's theoretical model and were found to be in excellent agreement. This result proved that experimentally determined processing parameters for each composition were well optimized.

태양열 집열기에 사용될 선택흡수막의 성능 평가 (Performance Evaluation of Selective Coatings for Solar Thermal Collectors)

  • 이길동
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.43-50
    • /
    • 2012
  • Metal-metal oxide (M-M oxide) cermet solar selective coatings with a double cermet layer film structure were deposited on the Al-deposited glass substrate by using a directed current (DC) magnetron sputtering technology. M oxide (CrO and ZrO) was used as the ceramic component in the cermets, and Cr and Zr used as the metallic components. In addition, black Cr (Cr-$Cr_2O_3$ cermet) solar selective coatings were deposited on the Ni-plated Cu substrate by using a electroplating method for comparison. The thermal stability tests were carried out for performance evaluation of solar coatings. Reflectance measurements were used to evaluate both solar absorptance(${\alpha}$) and thermal emittance (${\epsilon}$) of the solar coatings before and after thermal testing by using a spectrometer. Optical properties of optimized cermet solar coatings were ${\alpha}{\simeq}0.94-0.96$ and ${\epsilon}{\simeq}0.1$ ($100^{\circ}C$). The results of thermal stability test of M-M oxide solar coatings showed that the Cr-CrO cermet solar selective coatings were more stable than the Zr-ZrO cermet selective coatings at temperature of both $400^{\circ}C$ in air and $450^{\circ}C$ in vacuum. The black Cr solar selective coatings were degraded in air at temperature of $400^{\circ}C$. The main optical degradation modes of these coatings were diffusion of metal atoms, and oxidation.

Ameliorative Effect of a Selective Endothelin $ET_A$ Receptor Antagonist in Rat Model of L-Methionine-induced Vascular Dementia

  • Mangat, Gautamjeet S.;Jaggi, Amteshwar S.;Singh, Nirmal
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제18권3호
    • /
    • pp.201-209
    • /
    • 2014
  • The present study was designed to investigate the efficacy of selective $ET_A$ receptor antagonist, ambrisentan on hyperhomocysteinemia-induced experimental vascular dementia. L-methionine was administered for 8 weeks to induce hyperhomocysteinemia and associated vascular dementia in male rats. Ambrisentan was administered to L-methionine-treated effect rats for 4 weeks (starting from $5^{th}$ to $8^{th}$ week of L-methionine treatment). On $52^{nd}$ day onward, the animals were exposed to the Morris water maze (MWM) for testing their learning and memory abilities. Vascular endothelial function, serum nitrite/nitrate levels, brain thiobarbituric acid reactive species (TBARS), brain reduced glutathione (GSH) levels, and brain acetylcholinesterase (AChE) activity were also measured. L-methionine-treated animals showed significant learning and memory impairment, endothelial dysfunction, decrease in/serum nitrite/nitrate and brain GSH levels along with an increase in brain TBARS levels and AChE activity. Ambrisentan significantly improved hyperhomocysteinemia-induced impairment of learning, memory, endothelial dysfunction, and changes in various biochemical parameters. These effects were comparable to that of donepezil serving as positive control. It is concluded that ambrisentan, a selective $ET_A$ receptor antagonist may be considered as a potential pharmacological agent for the management of hyperhomocysteinemia-induced vascular dementia.

초음파 서모그라피를 이용한 빠른 PCB 결함 검출 (Fast Defect Detection of PCB using Ultrasound Thermography)

  • 조재완;정현규;서용칠;정승호;김승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.273-275
    • /
    • 2005
  • Active thermography is being used since several years for remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements were performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

  • PDF

Comparison of the bond strength of ceramics to Co-Cr alloys made by casting and selective laser melting

  • Lawaf, Shirin;Nasermostofi, Shahbaz;Afradeh, Mahtasadat;Azizi, Arash
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.52-56
    • /
    • 2017
  • PURPOSE. Considering the importance of metal-ceramic bond, the present study aimed to compare the bond strength of ceramics to cobalt-chrome (Co-Cr) alloys made by casting and selective laser melting (SLM). MATERIALS AND METHODS. In this in-vitro experimental study, two sample groups were prepared, with one group comprising of 10 Co-Cr metal frameworks fabricated by SLM method and the other of 10 Co-Cr metal frameworks fabricated by lost wax cast method with the dimensions of $0.5{\times}3{\times}25\;mm$ (following ISO standard 9693). Porcelain with the thickness of 1.1 mm was applied on a $3{\times}8-mm$ central rectangular area of each sample. Afterwards, bond strengths of the samples were assessed with a Universal Testing Machine. Statistical analysis was performed with Kolmogorov-Smirnov test and T-test. RESULTS. Bond strength in the conventionally cast group equaled $74.94{\times}16.06\;MPa$, while in SLM group, it equaled $69.02{\times}5.77\;MPa$. The difference was not statistically significant ($P{\leq}.05$). CONCLUSION. The results indicated that the bond strengths between ceramic and Co-Cr alloys made by casting and SLM methods were not statistically different.

Facile and Selective Synthesis of ZnO Hollow or Crumpled Spheres and Their Photocatalytic Degradation Activities

  • Choi, Yomin;Lee, Young-In
    • 한국세라믹학회지
    • /
    • 제55권3호
    • /
    • pp.261-266
    • /
    • 2018
  • Hollow or bumpy ZnO structures with micrometer-size features have been investigated as photocatalysts for water purification due to their high surface area available for reaction with harmful organic molecules and relatively large size for easy separation after finishing the photocatalytic reaction. In this study, selective synthesis of ZnO hollow or crumpled microspheres was performed using a simple and versatile ultrasonic spray pyrolysis process with various zinc precursors. The morphologies, phases, specific surface areas, and optical properties of the microspheres were characterized using X-ray diffraction, scanning electronic microscopy, nitrogen adsorption-desorption isotherms, and UV-vis spectroscopy. In addition, the mechanism underlying the formation of different morphologies and their photocatalytic activities were systematically investigated.