• Title/Summary/Keyword: Selective recovery

Search Result 265, Processing Time 0.031 seconds

Selective adsorption of ammonium ion via cobalt-based Prussian blue analogue (코발트 기반 프러시안블루 유사체를 이용한 수중 암모늄 이온의 선택적 흡착)

  • Tae Hwan Kim;Narges Dehbashi Nia;Yeo-Myeong Yun;Tae-Hyun Kim;Yuhoon Hwang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.2
    • /
    • pp.95-107
    • /
    • 2024
  • This study proposes the use of a cobalt-based Prussian blue analogue (Co-PBA; potassium cobalt hexacyanoferrate), as an adsorbent for the cost-effective recovery of aqueous ammonium ions. The characterization of Co-PBA involved various techniques, including Fourier-transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, nitrogen adsorption-desorption analysis, and zeta potential. The prepared Co-PBA reached an adsorption equilibrium for ammonium ions within approximately 480 min, which involved both surface adsorption and subsequent diffusion into the interior. The isotherm experiment revealed a maximum adsorption capacity of 37.29 mg/g, with the Langmuir model indicating a predominance of chemical monolayer adsorption. Furthermore, the material consistently demonstrated adsorption efficiency across a range of pH conditions. Notably, adsorption was observed even when competing cations were present. Co-PBA emerges as a readily synthesized adsorbent, underscoring its efficacy in ammonium removal and selectivity toward ammonium.

Multi-stage Process Study of PEI-PDMS Hollow Fiber Composite Membrane Modules for $H_2/CO_2$ Mixed Gas Separation ($H_2/CO_2$ 혼합기체의 분리를 위한 PEI-PDMS 중공사 복합막 모듈의 다단 공정 연구)

  • Lee, Chung Seop;Cho, Eun Hye;Ha, Seong Yong;Chung, Jong Tae;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Poly(ether imide) (PEI)-poly(dimethylsioxane) (PDMS) composite membranes and their modules were prepared, which are capable of selective $CO_2$ separation from the mixture gas. The gas flow rate, concentration, recovery ratio of $H_2$ and removal ratio of $CO_2$ outflowing by stage-cut were characterized at $25^{\circ}C$ and the constant pressure. In addition, to increase the recovery ratio of $H_2$, one stage, two stage series connection, and three stages series + parallel connection tests were carried out. When the stage-cut was 0.32 for the three stages connection operation, the concentration $H_2$ of the produced gas and the recovery ratio of $H_2$ was 97% and 85%, respectively. And also the removal ratio of $CO_2$ was 90% was obtained and the recycled gas concentration was similar with that of the feed gases.

Selective Contralateral Exploration in Pediatric Inguinal Hernia (소아서혜부탈장의 선택적 편대측 시험절개)

  • Lee, Myung-Duk
    • Advances in pediatric surgery
    • /
    • v.1 no.1
    • /
    • pp.18-26
    • /
    • 1995
  • For the prevention of later contralateral hernia as well as unnecessary contralateral exploration in pediatric patients with unilateral inguinal hernias, a reasonable indication of contralateral exploration is required. To examine the contralateral positivity, a prospective selective contralateral exploration has been performed by the author from Sept. 1985 to Dec. 1993, at Pediatric Surgical Section of the Department of Surgery, Kangnam St. Mary's Hospital, Catholic University Medical College. Among the total 1200 cases of pediatric inguinal hernias, 580 cases of contralateral side were explored at hernia operations, by the indications as; male with infant onset, 2)female of all age, 3)prematurity, 4)profuse ascites due to cirrhosis, nephrotic syndrome, and ventriculoperitoneal shunt, and 5)remarkable silk sign. Overall positive rate was 71.4%, and positive rates of each indication were 80.7%, 70.4%, 73.1%, 66.7%, and 72.0%, respectively. Right side hernia showed 67.0%, left s ide 75.7%, and positive familial history 71.8% of contralateral positivities. In male, getting older revealed lower positive rates and the rate suddenly dropped after 12 years of age. Birth order, mother's age at delivery, postmaturity did not show any significant differences between the rates. Recurrence was seen in 3(0.5%) ipsilateral and 2(0.3%) contralateral, both of which were negative esplorations on previons operations. Overall complication rate was 3.8%, including 1 infection, 14 fluid or blood accumulation, 5 edemas, 3 temporary testicular edemas, 2 persisting fevers, 2 enures is and one delayed recovery from anesthesia. Among 38 cases with contralateral hernias developed after unilateral surgery by authors(6 cases) or surgeons in other institutions, 14 were males with infant onset, 4 were prematurities and 9 were females. Therefore, 27(71.7%) cases were originally under the contralateral exploration indications. The primary site of the hermia was right in 25 and left in 13. With above results, the following indications for contralateral exploration could be suggested ; 1)under one year of age, both sex, 2)prematurity, 3) remarkable silk sign, 4)in the double checked suspicions among males with infant onset, all age females, ascites, left hernia and familial history. After 12 years of age, exploration is not required. Considering complications, contralateral explorations could be considered only in the following situations; 1)expert, experienced pediatric surgeon, 2)experienced pediatric anesthesiologist, 3)operations could be done smoothly in an hour, 4)good general condition of the patient.

  • PDF

Site-selective Photoluminescence Spectroscopy of Er-implanted Wurtzite GaN under Various Annealing Condition

  • Kim, Sangsig;Sung, Man Young;Hong, Jinki;Lee, Moon-Sook
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.1
    • /
    • pp.26-31
    • /
    • 2000
  • The ~1540 nm $^4$ $I_{13}$ 2/ longrightarro $w^4$ $I_{15}$ 2/ emissions of E $r^{3+}$ in Er-implanted GaN annealed at temperatures in the 400 to 100$0^{\circ}C$ range were investigated to gain a better understanding of the formation and dissociation processes of the various E $r^{3+}$ sites and the recovery of damage caused by the implantation with increasing annealing temperature ( $T_{A}$).The monotonic increase in the intensity of the broad defect photoluminescence(PL) bands with incresing $T_{A}$ proves that these are stable radiative recombination centers introduced by the implantation and annealing process. Theser centers cannot be attributed to implantation-induced damage that is removed by post-implantation annealing. Selective wavelength pumpling of PL spectra at 6K reveals the existence of at least nine different E $r^{3+}$ sites in this Er-implanted semiconductor. Most pf these E $r^{3+}$ PL centers are attributed to complexed of Er atoms with defects and impurities which are thermally activated at different $T_{A}$. Only one of the nine observed E $r^{3+}$ PL centers can be pumped by direct 4f absorption and this indicates that it is highest concentration E $r^{3+}$ center and it represents most of the optically active E $r^{3+}$ in the implanted sample. The fact that this E $r^{3+}$ center cannot be strongly pumped by above-gap light or broad band below-gap absorption indicates that it is an isolated center, i.e not complexed with defects or impurities, The 4f-pumped P: spectrum appears at annealing temperatures as low as 40$0^{\circ}C$, and although its intensity increase monotonically with increasing $T_{A}$ the wavelengths and linewidths of its characteristic peaks asre unaltered. The observation of this high quality E $r_{3+}$PL spectrum at low annealing temperatures illustrates that the crystalline structure of GaN is not rendered amorphous by the ion implantation. The increase of the PL intensities of the various E $R_{3+}$sites with increasing $T_{A}$is due to the removal of competing nonradiative channels with annealing. with annealing.annealing.

  • PDF

Condensable Gas Separation using Phenol! Alumina Composite Activated Carbon Hollow Fiber Membranes (페놀수지/알루미나 복합 활성탄소중공사막을 이용한 응축성 기체 분리)

  • Shin, Kyung-Yong;Park, You-In;Kim, Beom-Sik;Koo, Kee-Kahb
    • Membrane Journal
    • /
    • v.20 no.4
    • /
    • pp.312-319
    • /
    • 2010
  • Carbon membrane materials have received considerable attention for the gas separation including hydrocarbon mixture of ingredients of the volatile organic compounds(VOCs) because they possess their higher selectivity, permeability, and thermal stability than the polymeric membranes. The use of activated carbon membranes makes it possible to separate continuously the VOCs mixture by the selective adsorption-diffusion mechanism which the condensable components are preferentially adsorbed in to the micropores of the membrane. The activated carbon hollow fiber membranes with uniform adsorptive micropores on the wall of open pores and the surface of the membranes have been fabricated by the carbonization of a thin film of phenolic resin deposited on porous alumina hollow fiber membrane. Oxidation, carbonization, and activation processing variables were controlled under different conditions in order to improve the separation characteristics of the activated carbon membrane. Properties of activated carbon hollow fiber membranes and the characterization of a gas permeation by pyrolysis conditions were studied. As the result, the activated carbon hollow fiber membranes with good separation capabilities by the molecular size mechanism as well as selective adsorption on the pores surface followed by surface diffusion effective in the recovery hydrocarbons have been obtained. Therefore, these activated carbon membranes prepared in this study are shown as promising candidate membrane for separation of VOCs.

CARIES-RELATED MICROBIOLOGICAL SCREENING IN CHILDREN UNDER THREE YEARS OF AGE (3세이하의 어린이의 치아우식증과 관련된 미생물학적 선별검사)

  • Park, Jae-Hong;Lee, Keung-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.728-737
    • /
    • 2003
  • To evaluate microbial data and salivary measurements from clinically compatible, culture-based screening procedures employed with children younger than 36 months old. Plaque and stimulated saliva specimens were collected from 87 children. The pH of each saliva sample was measured before and after 0.94% lactic acid was added. Specimens were diluted and plated on selective media and non-selective media. Data collected were counts of mutans streptococci (MS) and lactobacilli (LB). In addition, total viable counts (TVC) of specimens, salivary pH and buffering capacity were also assessed. Each variable was compared to caries status of subjects. According to this study, the results were as followed: 1. Highly significant correlation with caries rates were found for counts of MS and LB. 2. The specific counts/ml saliva or plaque above which caries is predicted, or below which caries is not predicted were as follows: 1) Saliva MS; $10^5$ 2) Plaque MS; $2{\times}10^5$ 3) Saliva LB; $10^3$ 4) Plaque LB; $10^3$. 3. Salivary pH and buffering capacity versus caries status were not significant. 4. Microbial screening methods based on mutans streptococci had higher predictive values and odds ratios than methods for lactobacilli. 5. MS counts were clearly the best indicators of caries status in young children. This measurement can easily be obtained in a dental clinical setting both by conventional culture techniques, or commercial kits for MS recovery.

  • PDF

Comparison of Four Different Isolation Media for Staphylococcus aureus (황색포도상구균 분리배지 비교)

  • Oh, Min-Hee;Kang, Seong-Il;Hong, Sang-Phil;Oh, Se-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.5
    • /
    • pp.606-611
    • /
    • 2009
  • Performance test was carried out between selective media which are generally used in Staphylococcus aureus isolation from food. Sensitivity, determined according to the appearance of characteristic colonies when 30 different S. aureus strains were tested, resulted as Baird-Parker agar (RPF)> $Petrifilm^{TM}$ Staph Express plate> Baird-Parker agar> Mannitol salt agar. Also, the four different media showed the same selectivity because all tested media did not produce the false positive colonies. Recovery efficiency from the artificially inoculated foodstuff was almost the same for the tested media. Presumptive colonies were collected from the dried fishery product using Mannitol salt agar and collected strains were tested on 4 different selective agar. Almost presumptive strains did not show the false positive colonies except for S. carnosus ssp carnosus. This strain was identified as false positive colonies on Mannitol salt agar, Baird-Parker agar and $Petrifilm^{TM}$ Staph Express plate. But Baird-Parker agar (RPF) did not show the false positive colonies with the same strains. So, it was concluded that the Baird-Parker agar (RPF) has more higher selectivity than other tested media in this experiment.

Efficiency of PetrifilmTM Staph Express Count Plate for the Enumeration of Staphylococcus aureus in Meat, Fishery Product, and Korean Traditional Foods (축·수산·전통식품 중 황색포도상 구균의 정량적 분석을 위한 PetrifilmTM Staph Express Count Plate의 성능 평가)

  • Yoo, Yoonjeong;Choi, Yuna;Choi, Seungho;Bang, Hyunjo;Yoon, Yohan;Ha, Jimyeong;Lee, Soomin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.309-315
    • /
    • 2019
  • To enumerate Staphylococcus aureus in food, Baird-Parker Agar (BPA) is usually used in the conventional method, However it requires time and space for the preparation and plating, and incubation. Thus, use of the $3M^{TM}$ $Petrifilm^{TM}$ Staph Express Count Plate (STX Petrifilm) might be appropriate to solve these challenging problems. The purpose of this study was to compare the efficiency of STX Petrifilm with BPA for enumeration of S. aureus in various foods. A mixture of S. aureus strains ATCC29213, ATCC25923, and ATCC13565 was inoculated on marinated pork chop, beef (chuck tender), dried filefish, semi-dried squid, rice cake, and Japchae (stir-fried glass noodles) at 2, 3, 5, and 7 Log CFU/g. S. aureus cell counts were enumerated by spread-plating on STX Petrifilm and BPA after 0 and 24 hours at $4^{\circ}C$ (marinated pork chop, beef, semi-dried squid, and stir-fried glass noodles) and $25^{\circ}C$ (dried filefish and rice cake). Recovery of STX Petrifilm for S. aureus from various food samples was compared with BPA, and the results showed that there were no significant differences between two selective media in all cases. The results indicated that STX Petrifilm had enough efficiency to recover S. aureus from various foods as well as saving time and space.

Simultaneous quantitative determination of urinary cholesterol, desmosterol and lanosterol in pravastatin treated rats by gas chromatography/mass spectrometry (Gas Chromatography/Mass Spectrometry를 이용한 Pravastatin 투여 쥐의 뇨 중 Cholesterol, Desmosterol, Lanosterol의 동시분석법)

  • Kumar, Bhowmik Salil;Chung, Bong Chul;Lee, Young-Joo;Yi, Hong Jae;Jung, Byung Hwa
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.407-414
    • /
    • 2009
  • A simultaneous determination method for cholesterol, lanosterol and desmosterol was developed using gas chromatography/mass spectrometry. Urine was enzymatically hydrolyzed with ${\beta}$-glucuronidase/arylsulfatase. Samples were prepared using extractions with a mixture of ethyl acetate-hexane (2:3, v/v), followed by derivatization with a mixture of MSTFA/TMSI/TMCS (100:2:5 v/v/v). All analyses were performed using GC/MS in selective ion monitoring mode. Good linearities ($r^2=0.998{\sim}0.999$) in calibration curve and a satisfactory recovery (80.0%~113%) were achieved. Accuracy and precision values within ${\pm}15%$ in the concentration range of 5 to 200 ng/mL were also observed for all compounds. The developed method was applied to pravastatin-treated (70 and 250 mg/kg/day for 7 days, oral) hyperlipidemia rats. Those sterols were significantly lower in drug-treated rats compared to the controls, which justifies the drug efficacy. Therefore, these results indicate that the developed method was successfully applied to examine statin drug efficacy with urine sample.

New Analytical Methods for Separation and Identification of Heavy Metals (II). A Study on the Adsorption and Recovery of Cu(Ⅱ) ion by Amberlite XAD-7 Resins Impregnated with Chelating Agents (중금속의 분리 및 검출을 위한 분석화학적 연구 (제 2 보) 킬레이트제-Amberlite XAD-7 침윤수지에 의한 Cu(II) 이온의 흡착 및 회수에 관한 연구)

  • Dae Woon Lee;Chul Hun Eum;Tae Sung Kim;Doo-Soon Shin;Koo Soon Chung
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.4
    • /
    • pp.308-314
    • /
    • 1987
  • The adsorption behavior of some chelating agents on the Amberlite XAD-7 resin was studied to obtain the optimum conditions for the preparation of chelating agent-XAD-7 resins. The chosen chelating agents are cupferron (CP), diphenylcarbazone (DPC), salicylaldoxime (SAO), thiosalicylic acid (TSA), and dimethylglyoxime (DMG), which have been well known chelating agents to Cu(Ⅱ) and Ni (Ⅱ) ions. Among the chelating agent-XAD-7 resins, SAO-XAD-7 and DMG-XAD-7 resins were evaluated as appropriate impregnated resins by investigating their stabilities in the wide pH range and high abilities to adsorb Cu(Ⅱ) and Ni(Ⅱ) ions. The selective adsorption of Cu(Ⅱ) from Ni(Ⅱ) was possible by changing pH condition by SAO-XAD-7 resin. The adsorption capacities of SAO-XAD-7 and DMG-XAD-7 for Cu(Ⅱ) were $7{\times}10^{-3}mmol$ Cu(Ⅱ) per gram of resin and $2{\times}10^{-3}mmol$ Cu(Ⅱ) per gram of resin, respectively. The quantitative recovery of Cu(Ⅱ) adsorbed by the resin was demonstrated. The adsorption behavior of Cu(Ⅱ) and Ni(Ⅱ) by the single and mixed bed of chelating agent-XAD-7 resin was discussed.

  • PDF