• Title/Summary/Keyword: Selected ion monitoring

Search Result 161, Processing Time 0.036 seconds

Assessment of correlation between markers of ambient monitoring and biological monitoring of dimethylformamide for workers in synthetic leather manufacturing factories in Korea (국내 합성피혁제조업 근로자에 대한 디메틸포름아미드의 공기중 농도와 생물학적 노출지표간의 상관성 평가)

  • Hwang, Yang In;Lee, Mi-Young;Chung, Yun Kyung;Kim, Eun A
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.315-325
    • /
    • 2013
  • The possibility of acute hepatotoxicity caused by dimethylformamide (DMF) requires regular monitoring of the workers who are using DMF to prevent the occupational disease. The authors performed ambient and biological monitoring of workers involved in synthetic leather manufacturing processes using DMF to assess the correlation between the markers of ambient and biological monitoring of DMF. The authors monitored 142 workers occupationally exposed to DMF from 19 workshops in the synthetic leather and ink manufacturing industries located in northern region of Gyeonggi-do. The subjects answered questionnaire on work procedure and use of personal protective equipment to be classified by exposure type. DMF in air samples collected using personal air samplers, diffusive and active sampler, was analysed using gas chromatograph-flame ionization detector (GC-FID) with DB-FFAP column (length 30 m, i.d. 0.25 mm, film thickness 0.25 ${\mu}m$). Urinary N-methylformamide (NMF) was analysed using gas chromatograph-mass selective detector (GC-MSD) at selected ion monitoring (SIM) mode with DB-624 column (length 60 m, i.d. 0.25 mm, film thickness 1.40 ${\mu}m$). Geometric mean (GM) and geometric standard deviation (GSD) of the ambient DMF was $6.85{\pm}3.43$ ppm, and GM and GSD of urinary NMF was $42.3{\pm}2.7$ mg/L. The ratio of subjects with DMF level over 10 ppm was 44%, and those with urinary NMF over 15 mg/L was 87%. NMF in urine adjusted by DMF in air was $4.61{\pm}2.57$ mg/L/ppm and $9.50{\pm}2.41$ mg/L/ppm, respectively, with or without respirator. There was seasonal differences of NMF in urine adjusted by DMF in air, $7.63{\pm}2.74$ mg/L/ppm in summer and $4.53{\pm}2.29$ mg/L/ppm in winter. The urinary NMF concentration which corresponds to 10 ppm of ambient DMF was 52.7 mg/L (r=0.650, n=128). Considering the difference of the route of exposure which resulted from the compliance of wearing personal protective equipment, the estimated contribution of respiratory and dermal exposure route for DMF was 48.5% vs. 51.5%.

Keratanase II Digestion Accompanied with a Liquid Chromatography/Tandem Mass Spectrometry for Urinary Keratan Sulfate Quantitative Analysis

  • Chuang, Chih-Kuang;Lin, Hsiang-Yu;Wang, Tuen-Jen;Huang, Sung-Fa;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.3 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: Mucopolysaccharidosis IV (MPS IV) is a disease characterized by deficient activity of N-acetylgalactosamine-6-sulfatase (GALNS) causing excessive lysosomal storage of keratan sulfate (KS). The identification of the relevant disaccharide units of KS after keratanase II digestion followed by liquid chromatography/tandem mass spectrometry detection (LC-MS/MS) is validated and applicable for the preliminary diagnosis of MPS IV. Methods: A total of 67 urine samples were collected and analyzed from 11 MPS IV patients comprising 10 MPS IVA and one MPS IVB patients, and 56 normal controls. Urinary glycosaminoglycan was first precipitated by the Alcian blue method followed by a digestion of keratanase II. The protonated species of the digested disaccharide products were detected by using multiple reaction monitoring experiment. Results: One particular disaccharide of KS was selected. The transition mass-to-charge (m/z) of the parent ion and its daughter ion after collision was $462.0{\rightarrow}97.0$, whereas the chondrosine used as an internal standard in this assay was m/z $353.9{\rightarrow}73.0$. The results corresponded well with the two-dimensional electrophoresis method. The quantities of urinary KS were significantly raised in confirmed MPS IV patients when comparing with those of normal controls ($170.2{\pm}81.1$ vs. $4.06{\pm}1.92{\mu}g/mL$). Conclusion: The LC-MS/MS method for MPS IVA determination is specific, sensitive, validated, and applicable for urinary KS quantification. This method can be used not only as a first-line biochemistry examination of MPS IVA, but also as an outcome survey after enzyme replacement therapy.

A Study on Contents of Anti-impotence drug/drug-like compounds in Food (식품중 발기부전 치료제 및 유사물질 함량에 관한 조사연구)

  • Hong, Hae-Geun;Bang, Seon-Jae;Park, Kwang-Hee;Lee, In-Sook;Park, In-Jung;Park, Jeung-Hwa;Kim, Jong-Chan
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.89-96
    • /
    • 2007
  • To determine 8 anti-impotence drug/drug-like compounds such as sildenafil, vardenafil, tadalafil, homosildenafil, hydroxyhomosildenafil, aminotadalafil, pseudovardenafil and hongdenafil in foods, simultaneously, high performance liquid chromatography(HPLC) and liquid chromatography-mass spectrometry (LC/MS) were used. The HPLC/UV analysis was performed on a column of capcellpak $C_{18}$ with 0.1% sodium-1-hexansulfonate in 0.2M ammonium formate/acetonitrile as a mobile phase. Mass spectra of the compounds by LC/MS were investigated with SCAN mode(Mass range and Fragment voltage) and SIM(Selected Ion Monitoring) mode (Ion target and Fragment voltage). The results follow as; 1. The HPLC/UV analysis was detected from 5 out of 63 samples. The content of sildenafil was in the range of 32.80 ppm ${\sim}$ 60.13 ppm from 4 out of 5 samples. The contents of sildenafil, vardenafil, homosildenafil were in the range 47.14 ppm from 1 out of 5 samples. 2. The conformed result of LC/MS was equal of detected from 5 out of 63 samples in HPLC/UV analysis. An easily available, simultaneous determination of 8 standards in adulterated health related foods was established by using a combination of LC/MS methods.

Determination of Radiolysis Produce of DHOA by GC/MS (GC/MS를 이용한 DHOA의 방사선 분해생성물 분석)

  • Yang, Han-Beom;Lee, Eil-Hee;Lim, Jae-Kwan;Chung, Dong-Yong;Kim, Kwang-Wook;Kim, Jong-Seung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • Dihexyloctanamide(DHOA) was used as an extractant or phase modifier with the diamide extractants in a solvent extraction process for a radioactive liquid waste treatment. The degradation compounds of the DHOA extractant, irradiated with $^{60}Co$ gamma ray, were octanoic acid and dihexylamine which are identified by a Fourier transform infrared(FT-IR) and gas chromatograph/mass spectrometer(GC/MS) analysis, and determined by the GC/MS with selected ion monitoring(SIM) mode. Retention behavior of octanoic acid, tridecane (internal standard) and dihexylamine in total ion chromatogram (TIC) were 8.65 min., 9.79 min., and 10.27 min., respectively. With increasing the absorbed dose of the $\gamma$-ray irradiated DHOA, the concentration of octanoic acid was decreased and that of dihexylamine was increased.

  • PDF

Analysis of Amineptine and its Metabolites in Human Urine by Gas Chromatography/Mass Spectrometry (Gas Chromatography/Mass Spectrometry를 이용한 뇨중 Amineptine과 그 대사체 분석방법에 관한 연구)

  • Lee, Jeong Ae;Kim, Younglim;Lho, Dong-Seok
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.385-393
    • /
    • 2000
  • A gas chromatography-mass spectrometric (GC/MS) procedure for the determination of amineptine (dihydro-10, 11-dibenzo[a, d] cycloheptenyl-5-amino-7-heptanoic acid) and its main metabolites in human urine was described. Amineptine has been known to be extensively metabolized by the ${\beta}$-oxidation of the heptanoic side chain with formation of pentanoic side chain metabolite ($C_5$-metabolite), and lactamizarion by internal dehydration of (${\beta}$-oxidized metabolite (${\delta}$-lactam). The detection of these compounds was based on acid hydrolysis, liquid-liquid extraction and trimethylsilylated derivatization of the carboxylic acid group. For the determination of amineptine and its metabolites in biological fluids, selected ions at the m/ 192, molecular ion and one of the characteristic ions were monitored by GC/MS. On the excretion study of amineptine in human urine, 70-90% of amineptine, ${\delta}$-lactam, and $C_5$-metabolite were found to be excreted within 4 hours and their excretion completed within 20 hours.

  • PDF

Simultaneous Determination of Various Pesticides : Analysis Utilizing GC/MSD (SIM mode) (잔류농약 다성분 동시분석법 : GC-MSD (SIM mode)를 사용한 분석)

  • Rho, Kyoung-Ah;Kim, Hyeon-Wee;Lee, Yoon-Kyoung
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.721-727
    • /
    • 1998
  • An analytical method for simultaneous and rapid determination of organophosphorus, organochlorine, carbamate, and pyrethroid pesticides in polished rice was developed. The analysis is performed by gas chromatograph with mass selective detector (GC/MSD) in selected ion monitoring (SIM) mode. Pesticides were extracted from samples with acetone by automated Soxhlet apparatus and this extract was evaporated to dryness for the analysis. The residue was dissolved in hexane, followed by a treatment with a Sep-Pak florisil catridge. Pesticides were positively confirmed by GC/MS, retention times, and ion ratios. This analytical method allows a rapid, reliable, and a good recovery of hydrophilic pesticides. Except far captafol, captan, dichlofluanid and dichlorvos, recoveries of 42 pesticides were over 70%.

  • PDF

Synthesis of DMDBTDMA and determination of radiolysis products by GC/MS (DMDBTDMA의 합성 및 방사선 분해산물의 GC/MS 분석)

  • Yang, Han-Beom;Lee, Eil-Hee;Park, Gyo-Beom
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.403-411
    • /
    • 2008
  • Dimethyldibutyltetradecylmalonamide (DMDBTDMA) extractant was used in a solvent extraction process for a radioactive liquid waste treatment. For the study of radiolysis phenomena, DMDBTDMA was synthesized and the degradation compounds (n-methylbutylamine, tetradecane, 1-tetradecanol) in the DMDBTDMA extractant, irradiated with $^{60}Co$ gamma ray, were identified and determined as radiolysis products by a Fourier transform infrared (FT-IR), gas chromatograph/mass spectrometer (GC/MS) analysis and GC/MS with selected ion monitoring (SIM) mode. Retention behavior of n-methylbutylamine, n-dodecane, tetradecane and 1-tetradecanol in the total ion chromatogram with the standard materials and n-dodecane as the internal standard (ISTD) were 2.35 min., 8.83 min., 10.68 min. and 12.75 min., respectively. In the case of tetradecane, there was a linear relationship between the concentration of the tetradecane and the absorbed dose of the ${\gamma}$-ray irradiated DMDBTDMA.

Effects of Gastric Acidity on the Bioavailability of Scopolamine Hydrobromode and ${\ell}$-Hyoscyamine in Rabbits (Scopolamine Hydrobromide 및 $\ell$-Hyoscyamine의 생체이용성에 미치는 위산도의 영향)

  • Kim, C. Y.;Ham, S. H.;Han, S. S.;Sohn, D. H.;Ko, G. I.;Kim, J. B.
    • Korean Journal of Clinical Pharmacy
    • /
    • v.3 no.2
    • /
    • pp.131-137
    • /
    • 1993
  • The effects of gastric acidity on the bioavailability of scopolamine hydrobromide and ${\ell}$-hyoscya-mine were studied in rabbits. Each drug was administered orally at dose of 0.2mg/kg to gastric acidity controlled rabbits. The plasma concentration of scopolamine and ${\ell}$-hyoscyamine were determined by selected ion monitoring in GC/MSCScopolamine; m/Z= 138, ${\ell}$-Hyoscyamine; m/z= 124). Rabbits with hypoacidity showed significantly higher Cp and AVC than rabbits with hyperacidity after oral administration of each drug. From the results of this experiment, it is desirable that dosage regimen of dose of scopolamine and hyoscyamine should be adjusted when the drugs should be administered with antacids in clinical practice.

  • PDF

A study on the determination of residual Antibiotics and Synthetic Antibacterial Agents in Meat(III) Simultaneous Gas Chromatography/Mass Spectrometry Analysis of Erythromycin and Tylosin (식육중의 잔류 항생.항균제의 검정에 관한 연구(III) Macrolide계 항생물질인 Erythromycin과 Tylosin의 Gas Chromatography/Mass Spectrometry 동시분석)

  • 류재천;송윤선;양종순;서지원;김명수;박종세
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.1
    • /
    • pp.17-23
    • /
    • 1993
  • In an attempt to quantitate and qualitate residual antibiotics and antibacterial agents n meat simultaneously, we studied a gas chromatogrphy-mass spectrometry (GC/MS) analysis. For a simultaneous analysis of macrolide antibiotics such as erythromycin and tylosin in meat, the homogenization with MeOH, defatting with n-hexane, extraction with CHCl3, elution with CHCl3 : MeOH=2:1 from Sep-Pak silica cartridge, acid gydrolysis, back extraction with CHCl3, and quantitation by selected ion monitoring(SIM) mode after trimethylsilyl derivatization were performed. The recoveries of erythromycin and tylosin (CV,%) at 10 ppm fortification level were 90.59(4.89) and 45.91(0.20) , and the detection limits of those were 0.02 and 2.0 $\mu\textrm{g}$/g beef, respectively. From these results, the developed analytical method using GC/MS-SIM mode allows excellent detection and quantitation of residual macrolide antibiotics in meats, using complementary method with bio-assay.

  • PDF

Analytical Method of Epichlorohydrin in Canned Beverages by Purge-and- Trap/GC

  • Lee Kwang-Ho;Kwak In-Shin;Kim Dyoung-Il;Choi Byoung-Hee;Kim Guy-Joung;Lee Chul-Won
    • Proceedings of the Korean Society of Food Hygiene and Safety Conference
    • /
    • 2001.10a
    • /
    • pp.140-140
    • /
    • 2001
  • A sensitive analytical method based on gas chromatograpy-mass spectrometry with a selected ion monitoring (GC/MS-SIM) with the purge-and-trap concentration and with headspace method (in limited applications) was developed for determining of epichlorohydrin in canned beverages coated with epoxy resin. The calibration curve in the range of $0.5\sim50ng$ had correlation coefficient greater than 0.998 and a detection limit of $0.l\mug/L$ was obtained using a sample volume of 20ml. The predominant ions of epichlorohydrin produced in MSD using electron ionization(EI) were m/z 57 ([M-CI]+) and 62/64 $([M-CH_2O]+)$. In survey of epichlorohydrin in thirty commercial canned beverage samples, none of them was detected.

  • PDF