• 제목/요약/키워드: Seismic tests

검색결과 965건 처리시간 0.031초

액체금속로 면진 시험구조물의 해석모델링 개발 및 지진응답비교 (Development of Analysis Model and Comparison of Seismic Analysis Responses with Test Results for an Isolated Test Structure for Liquid Reactor)

  • 유봉;이재한;구경회
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.411-418
    • /
    • 2001
  • The initial analysis frequencies of the isolated test structure for seismic excitation tests give quite higher values to the actual modal test results. This large difference was redulted from some uncertainties in analysis modeling of several connection regions between column and upper beam, cross bars of the isolated structure. A modified simple analysis model is developed representing the actual dynamic behaviors of the test model, and the seismic analysis responses of the simple model are compared with those of the seismic tests.

  • PDF

사용후 연료 건식저장요기 1/8 규모 축소모형 지진응답시험 (Seismic Response Tests of 1/8 Scale Model for a Spent Fuel Dry Storage Cask)

  • 이재한;구경희;서기석;이흥영;최병일;염성호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.55-61
    • /
    • 2005
  • The seismic response tests of a spent fuel dry storage cask model of 1/8 scale are performed for an typical 1940 Elcentro earthquake. This paper focuses on the seismic response test data generation to check the overturing possibility of a storage cask and the slipping displacement on concrete slab bed. A simplified cask model is used to take into account the variations in seismic load magnitude and cask/bed interface friction. The test results show that the model gives an overturning response for an extreme condition.

  • PDF

MODEL TESTS ON LEVEES REINFORCED WITH SHEET PILES UNDER HIGH WATER CONDITIONS WITH/WITHOUT SEISMIC LOADING HISTORY

  • Koseki, Junichi;Tanaka, Hiroyuki;Otsushi, Kazutaka;Nagao, Naoya;Kaneko, Masaru
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 3차
    • /
    • pp.49-54
    • /
    • 2010
  • In order to study the performance of levees reinforced with steel sheet piles under high water condition, a series of model tests was conducted by simulating the high water condition before and after applying severe seismic loading history. As a result, the seepage behavior through the subsoil layers underlying the levee was not significantly affected by the seismic loading history. It was also verified that, irrespective of the seismic loading history, the sheet piles installed at the levee crest or shoulder are effective in preventing the breakage of levees caused by overflow. In addition, applicability of drainage works at the foot of the levee in preventing the seepage failure was confirmed.

  • PDF

강재 접합용 고전단 링앵커의 형상 개발과 전단실험 (Shape Decision and Shear Experiment of High-Shear Ring Anchor for Steel-Concrete Connection)

  • 전상현;김문길
    • 도시과학
    • /
    • 제7권2호
    • /
    • pp.29-36
    • /
    • 2018
  • The demand for reinforcement in accordance with remodeling, seismic retrofit, and change of use of the existing structure is increasing. Originally, shear wall new and extension method has been adopted a lot as seismic retrofit methods. Recently, dry seismic retrofit method that uses structural steel is mostly adopted in order to minimize spatiotemporal aspect and underpinning that occurs when a construct shear wall. We redesigned the form of old and new concrete joint high-shear ring anchor that was developed according to recent reinforcement method and determined construction method. Shear tests were performed on High-Shear Ring Anchor for steel-concrete connection. Comparison with 4 tests shows that the average of test-to-prediction ratios is 1.01.

Experimental investigations on seismic response of riser in touchdown zone

  • Dai, Yunyun;Zhou, Jing
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권3호
    • /
    • pp.348-359
    • /
    • 2018
  • A series of indoor simulation tests on a large-sized shaking table was performed, which was used to simulate the earthquake ground motion for the pipe-soil interaction system to be tested. The purpose of this study is to examine the dynamic characteristic and seismic response of a length of PVC pipeline lay on a clay seabed under seismic load. The pipeline was fully instrumented to provide strain and acceleration responses in both transverse and in-line. Dynamical modal tests show that corresponding mode shapes vertically and horizontally are basically the same. But the absolute values of the natural frequencies vertically are all higher than those corresponding values in transverse. It turned out that the geometry configuration of riser affects its stiffness. Seismic response of pipeline depends significantly on the waveform, and Peak Ground Acceleration (PGA). As the seismic loading progressed, the strain response was severe around both TDZ and catenary zone. Additionally, strain responses in top and bottom positions were more severe than the result in left or right side of the pipeline in the same section.

Seismic behavior of structures isolated with a hybrid system of rubber bearings

  • Chen, Bo-Jen;Tsai, C.S.;Chung, L.L.;Chiang, Tsu-Cheng
    • Structural Engineering and Mechanics
    • /
    • 제22권6호
    • /
    • pp.761-783
    • /
    • 2006
  • The enlargement of interest in base isolators as an earthquake-proof design strategy has dramatically accelerated experimental studies of elastomeric bearings worldwide. In this paper, a new base isolator concept that is a hybrid system of rubber bearings is proposed. Uniaxial, biaxial, and triaxial shaking table tests are also performed to study the seismic behavior of a 0.4-scale three-story isolated steel structure in the National Center for Research on Earthquake Engineering in Taiwan. Experimental results demonstrate that structures with a hybrid system of rubber bearings composed of stirruped rubber bearings and laminated rubber bearings can actually decrease the seismic responses of the superstructure. It has been proved through the shaking table tests that the proposed hybrid system of rubber bearings is a very promising tool to enhance the seismic resistance of structures. Moreover, it is demonstrated that the proposed analytical model in this paper can predict the mechanical behavior of the hybrid system of rubber bearings and seismic responses of the base-isolated structures.

Global seismic performance of a new precast CFST column to RC beam braced frame: Shake table test and numerical study

  • Xu, S.Y.;Li, Z.L.;Liu, H.J.
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.805-827
    • /
    • 2016
  • A new type of precast CFST column to RC beam braced frame is proposed in this paper. A series of shake table tests were conducted to excite a one-third scale six-story model for investigating the global seismic performance of this type of structure against earthquake actions. Particular emphasis was given to its dynamic property, global seismic responses and failure path. Correspondingly, a numerical model built on the basis of fiber-beam-element model, multi-layer shell model and element-deactivation method was developed to simulate the seismic performance of the prototype structure. Numerical results were compared with the measured values from shake table tests to verify the validity and reliability of the numerical model. The results demonstrated that the proposed novel precast CFST column to RC beam braced frame performs excellently under strong earthquake excitations; the "strong CFST column-weak RC beam" and "strong connection-weak member" anti-seismic design principles can be easily achieved; the maximum deflections of precast CFSTC-RCB braced frame satisfied the deflection limitations proposed in national code; the numerical model can properly simulate the dynamic property and responses of the precast CFSTC-RCB braced frame that are highly concerned in engineering practice.

JRTR 제어봉구동장치의 내진시험 (Seismic Test of the Control Rod Drive Mechanism for JRTR)

  • 최명환;김경호;선종오;조영갑
    • 한국소음진동공학회논문집
    • /
    • 제26권5호
    • /
    • pp.552-558
    • /
    • 2016
  • A control rod drive mechanism(CRDM) is a reactor regulating system, which inserts, withdraws or maintains a control rod within a reactor core to control the reactivity of the core. The CRDM for Jordan Research and Training Reactor with 5MW power has been designed and fabricated based on the HANARO’s experience through KAERI and DAEWOO consortium. This paper describes the seismic test results to demonstrate the operability, the drop performance and the structural integrity of CRDM during or after seismic excitations. The seismic tests are carried out under 5 OBE and 1 SSE loads at three Test Rigs simulating the reactor structure and the pool top. From the tests, the CRDM is smoothly driven without a malfunction of stepping motor under OBE load. The pure drop time under OBE and SSE loads is measured as 1.169s and 1.855s to meet the design requirement. Also, it is found that the CRDM maintains the structural integrity without a change of the function and natural frequency before and after seismic loads.

대형 지진하중에 대한 시편의 변형률기반 손상평가 (Strain-based Damage Evaluation of Specimens under Large Seismic Loads)

  • 권형도;허은주;이종민;김진원
    • 한국압력기기공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.24-31
    • /
    • 2018
  • In this paper, specimen tests with simulated large seismic conditions have been carried out to investigate damage characteristics such as structural deformation and crack initiation under seismic loading. The mechanical behavior of the specimens is predicted by numerical simulations and the strain-based damage evaluations are performed. Finite element analyses of the specimens under the simulated seismic loading at room and operating temperatures were carried out for low alloy steel and stainless steel materials. Peak strain amplitude, cumulative fatigue damage and cumulative strain limit damage are calculated considering the nature of cyclic loading. In all cases, the allowable damage criteria are exceeded at the time of observing cracks visually in the tests. Therefore, it is confirmed that the material behavior due to the large seismic loads can be predicted by the numerical method and the structural damage of the materials can be evaluated conservatively based on the strain criteria.

Pseudo-dynamic and cyclic loading tests on a steel-concrete vertical hybrid structure

  • Wang, Bo;Wu, Tao;Dai, Huijuan;Bai, Guoliang;Wu, Jian
    • Earthquakes and Structures
    • /
    • 제17권4호
    • /
    • pp.399-409
    • /
    • 2019
  • This paper presents the experimental investigations on the seismic performance of a peculiar steel-concrete vertical hybrid structural system referred to as steel truss-RC tubular column hybrid structure. It is typically applied as the supporting structural system to house air-cooled condensers in thermal power plants (TPPs). Firstly, pseudo-dynamic tests (PDTs) are performed on a scaled substructure to investigate the seismic performance of this hybrid structure under different hazard levels. The deformation performance, deterioration behavior and energy dissipation characteristics are analyzed. Then, a cyclic loading test is conducted after the final loading case of PDTs to verify the ultimate seismic resistant capacity of this hybrid structure. Finally, the failure mechanism is discussed through mechanical analysis based on the test results. The research results indicate that the steel truss-RC tubular column hybrid structure is an anti-seismic structural system with single-fortification line. RC tubular columns are the main energy dissipated components. The truss-to-column connections are the structural weak parts. In general, it has good ductile performance to satisfy the seismic design requirements in high-intensity earthquake regions.