• 제목/요약/키워드: Seismic evaluation

검색결과 1,599건 처리시간 0.164초

내진성능평가에 따른 정밀안전진단 및 내진 보수보강 조치의 개선방안 연구 (A study on the improvement plan for precision safety diagnosis and seismic repair and reinforcement measures according to seismic performance evaluation)

  • 김장욱
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2022
  • For an earthquake-safe urban environment, the Republic of Korea conducts seismic performance evaluation in accordance with laws and guidelines to assign safety ratings and implement necessary management measures such as repairs and reinforcements. In the seismic performance evaluation result, structures lacking in preparation for earthquakes are prioritized and classified into measures such as repair, reinforcement, or careful observation to respond to physical risks such as earthquakes. Such repair and reinforcement work is not a one-time thing, but it is necessary to further enhance the effect through continuous follow-up observation. In this study, the location of the vertical and horizontal displacement measuring part of the construction part is displayed so that the post-construction status of the reinforcement construction part can be visually checked by identifying the problems in the process of post-monitoring in 2022 for the maintenance and reinforcement work of local governments' public facilities carried out in 2021. We propose a plan to institutionalize the installation of, inspection tools, and crack gauges at certain locations in the construction department, and to have facility managers periodically inspect and manage them with a smartphone program or the 'Facility Autonomous Safety Inspection' app.

  • PDF

마찰진자시스템의 강성중심 변화에 따른 면진된 원전 구조물의 지진응답평가 (Seismic Response Evaluation of Seismically Isolated Nuclear Power Plant with Stiffness Center Change of Friction Pendulum Systems)

  • 석철근;송종걸
    • 한국지진공학회논문집
    • /
    • 제21권6호
    • /
    • pp.265-275
    • /
    • 2017
  • In order to improve the seismic performance of structures, friction pendulum system (FPS) is the most commonly used seismic isolation device in addition to lead rubber bearing (LRB) in high seismicity area. In a nuclear power plant (NPP) with a large self weight, it is necessary to install a large number of seismic isolation devices, and the position of the center of rigidity varies depending on the arrangement of the seismic isolation devices. Due to the increase in the eccentricity, which is the difference between the center of gravity of the nuclear structure and the center of stiffness of the seismic isolators, an excessive seismic response may occur which could not be considered at the design stage. Three different types of eccentricity models (CASE 1, CASE 2, and CASE 3) were used for seismic response evaluation of seismically isolated NPP due to the increase of eccentricity (0%, 5%, 10%, 15%). The analytical model of the seismic isolation system was compared using the equivalent linear model and the bilinear model. From the results of the seismic response of the seismically isolated NPP with increasing eccentricity, it can be observed that the effect of eccentricity on the seismic response for the equivalent linear model is larger than that for the bilinear model.

국내 학교시설 천장재의 내진성능 분석 (Analysis on the Seismic Performance of Ceiling System in School Buildings)

  • 박성철;조진일;정태환
    • 교육녹색환경연구
    • /
    • 제15권1호
    • /
    • pp.11-18
    • /
    • 2016
  • 본 연구는 학교현장의 안전교육 과정에서 학교시설 비구조재 중 위험도가 상대적으로 높은 천장재의 내진성능을 평가하고 대책방안을 제시하는 것이다. 평가도구의 개발을 위하여 본 연구는 다음과 같은 4단계로 진행되었다. 첫 단계에서는 국내 외의 내진성능평가 가이드라인들을 분석하여 주요 천장재의 구성품목과 각 품목별 평가방법들을 조사하고, 두 번째 단계에서는 문헌조사의 결과를 기반으로 주요 품목들의 내진성능 실태를 면밀하게 조사하였다. 세 번째 단계에서는 조사된 천장재 구조를 정량적으로 평가하여 지반 및 지진의 유형에 따른 적정성을 평가하였다. 마지막으로 국내 학교시설 천장재에서 우선적으로 고려되어야 할 내진성능보강 대책방안을 제시하였다.

GIS를 이용한 항만구조물의 내진성능 평가기법 (Evaluation on the Seismic Performance of Port Structures using GIS)

  • 김나영;강인준;최현;김태효
    • 대한공간정보학회지
    • /
    • 제22권4호
    • /
    • pp.31-38
    • /
    • 2014
  • 한반도의 지진은 1,900여회에 달할 정도로 심각하다. 최근 세계적으로 발생하는 지진으로 인해 지반 및 구조물에 대해 내진설계에 대한 투자가 국민의 소중한 생명과 재산을 지키는 수단으로 대두된다. 본 연구에서는 기존항만시설물 중에서 내진설계가 적용되지 않은 시설물을 대상으로 지진발생시 설계기준이상의 내진성능을 갖추었는지를 평가하였다. 그 결과를 중심으로 액상화 우려 지역을 분류하고, 내진안정검토 평가 및 분석을 지리정보시스템(GIS)을 이용하여 지진에 따른 액상화 재해 위험성과 구조적인 내진성능에 따른 내진성능 평가도를 작성하였다. 액상화 평가와 내진성능검토를 통한 정량적이고 구체적인 입력데이터베이스를 구축하고 분석된 모든 지진관련 자료들은 지진발생 우려지역의 보수 보강에 평가 자료로 직접적으로 사용 될 수 있었다.

동수압을 고려한 콘크리트 중력식 댐의 내진안전성 평가 (Seismic Safety Evaluation of Concrete Gravity Dams Considering Dynamic Fluid Pressure)

  • 김용곤
    • 한국안전학회지
    • /
    • 제21권1호
    • /
    • pp.120-132
    • /
    • 2006
  • Seismic safety evaluation of concrete gravity dams is very important because failure of concrete gravity dam may incur huge loss of life and properties around the dam as well as damage to dam structure itself. Recently, there has been growing much concerns about earthquake resistance or seismic safety of existing concrete gravity darns designed before current seismic design provisions were implemented. This research develops the dynamic fluid pressure calculation using 'added mass simulation'. The actual analysis using structural analysis package was performed. According to the analysis results, the vibration which is transverse to water flow seems to be very critical depending on the shape of the dam.

도시철도 구조물의 내진설계 및 평가 현황조사 (Current Status on Seismic Design/Evaluation of Metropolitan Rapid Transit System)

  • 김종민;김진호;임남형;강영종
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.220-223
    • /
    • 2008
  • Many structural engineers believed that RC underground structures like subway system might not be seriously damaged during earthquakes, until the Great Hanshin earthquake(a.k.a Kobe earthquake). But there is only one domestic seismic code of rapid transit system that established by Ministry of Construction & Transportation in 2005. Therefore, to investigate of current status on seismic design and evaluation method of rapid transit system is essential to estimate seismic performance of subway structural systems. In this study, comparing domestic codes and seismic evaluation methods with foreign system is performed.

  • PDF

화련 대형내진시험모델의 계측지진응답 평가 (Evaluation of Measured Seismic Responses of the Hualien LSST Model Structure)

  • 현창헌
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.249-256
    • /
    • 1997
  • This paper deals with the prediction and the evaluation of the measured seismic responses of the Hualien large-scale seismic test soil-structure system. The predicted analysis was carried out for the model structure by the computer code SASSI utilizing soil properties derived from geotechnical investigations and correlation analysis of recorded earthquake responses of soil. Utilizing the soil properties, seismic responses were predicted and compared with measured ones. The nonlinear effects of soil on structural responses were also evaluated.

  • PDF

대각보강근을 갖는 고인성 시멘트 복합체 커플링 보의 손상 평가 (Damage Evaluation for Precast HPFRCC Coupling Beams with Diagonal Reinforcement)

  • 김선우;전에스더;박완신;윤현도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.174-177
    • /
    • 2006
  • To restore an earthquake damaged community as quickly as possible, well-prepared reconstruction strategy is most essential. This paper reports experimental data on the seismic capacity of diagonal reinforced HPFRCC coupling beams with the Japanese Standard for Seismic Evaluation of Existing RC Buildings. Precast Based on the experimental results, HPFRCC specimen have more residual seismic capacity than RC specimen, but much study is necessary to improve the accuracy of the damage evaluation.

  • PDF

철근콘크리트 모멘트 골조 저층형 학교건축물의 내진성능 평가 (Seismic Performance Evaluation of Reinforced Concrete Moment Framed Low-story School buildings)

  • 황지현;박태원;한주연
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4580-4586
    • /
    • 2013
  • 대부분의 학교 건물은 내진설계기준이 적용되기 이전인 1988년 이전에 설계되었으며, 이후에 지어진 학교의 경우도 내진설계 적용대상에서 제외된 5층 이하의 건물로서 내진성능이 없을 것으로 판단된다. 건물의 특성상 많은 아이들이 밀집하여 있고, 재난 시 대피시설로 이용된다는 점에서 학교 건물의 내진성능보유는 특히 중요하다. 본 연구에서는 우리나라 학교건물의 대표적인 유형을 모델구조물로 선정하여 학교건축물에 대한 내진성능 평가를 수행하였다. 보유강도와 보유성능을 기초로 내진성능을 평가한 결과 모두 내진성능이 미흡한 것으로 나타났다.

Seismic evaluation and upgrading of RC buildings with weak open ground stories

  • Antonopoulos, T.A.;Anagnostopoulos, S.A.
    • Earthquakes and Structures
    • /
    • 제3권3_4호
    • /
    • pp.611-628
    • /
    • 2012
  • The inelastic earthquake response of existing, reinforced concrete buildings with an open ground story, designed according to the old Greek codes, is investigated before and after their seismic strengthening with steel braces restricted to the open ground stories. The seismic performance evaluation is based on Part 3 of Eurocode 8 for assessment and retrofitting of buildings. Three and five-story, symmetric and non-symmetric buildings are subjected to a set of seven pairs of synthetic accelerograms, compatible with the design spectrum, and conclusions are drawn regarding the effectiveness of the strengthening solutions. Seismic behavior of the selected models confirms results of previous work regarding the insufficient capacity of the open ground stories for design level earthquakes. It is also shown that strengthening only the weak ground story, a choice having the substantial advantage of low cost and continued usage of the building during its seismic retrofitting, can remove the inherent weakness without shifting the problem to the stories above and thus making such buildings at least as strong as those without a weak first story. This partial strengthening is possible for symmetric as well as eccentric buildings, in which torsion plays a further detrimental role.