• Title/Summary/Keyword: Seismic analysis of pile

Search Result 98, Processing Time 0.023 seconds

Numerical Analysis on the Behavior of Revetment Reinforced by Sand Compaction Pile According to Area Replacement Ratio (수치해석을 이용한 모래다짐말뚝 치환율에 따른 호안 구조물의 거동 분석)

  • Kim, Byoung-Il;Bong, Tae-Ho;Han, Jin-Tae;Jang, Young-Eun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • Sand compaction pile (SCP) is a ground improvement method which is used to secure the stability of the soft ground by using a type of replacement pile filled with coarse grained material. The behavior characteristics of the SCP, which is frequently used for improving both the onshore and offshore ground, is governed by the ground condition, the installation method, and replacement ratio. Therefore, the stability of the SCP in terms of the bearing capacity and displacement needs to be evaluated considering both the design values and in-situ conditions of construction site. In this study, numerical analysis is carried out based on the conditions of 00 revetment construction site in South Korea where unexpected displacement occurred during construction of SCP. Based on the analysis results, the displacement of the revetment structure according to the replacement ratio of the SCP was compared to the result calculated from design formulas. The results showed that the lateral displacement can be exceeded the reference value from proposed criteria regardless of increased replacement ratio of SPC. It is also confirmed that the behavior of the structure according to the replacement ratio of SPC in not reflected in the existing calculation methods. Therefore, the stability of the SCP composite ground should be examined through the site inspection after the SCP construction.

3-D Numerical Analysis for the Verification of Bearing Mechanism and Bearing Capacity Enhancement Effect on the Base Expansion Micropile (선단 확장형 마이크로파일의 3차원 수치해석을 통한 지지 메커니즘 및 지지력 증대효과 검증)

  • Lee, Seokhyung;Han, Jin-Tae;Jin, Hyun-Sik;Kim, Seok-Jung
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.2
    • /
    • pp.19-31
    • /
    • 2021
  • Micropiles are cast-in-place piles with small diameters. The advantage of micropile is low construction expense and simple procedures, so it is widely applied to existing buildings and structures for the reinforcement of foundation and seismic performances. The base expansion structure has been developed following the original mechanism of horizontal expansion steps under compressive loading. This kind of structure can be installed at the pile end to improve the bearing capacity by tip area enlargement and horizontal force increment to the pile surface area. However, 'Micropile with base expansion structure' cannot be put into practical use, because detailed verification for the developed technique has not been conducted so far. In this research, 3-D numerical analysis was conducted to figure out the bearing mechanism of base expansion micropile and to verify the bearing capacity improvement compared to the general micropiles. 3-D modelling of micropile with base expansion structure was carried out and input parameter was determined. Bearing mechanism induced by base expansion structure was analyzed by lab-scale modelling, and bearing capacity improvement was verified by field-scale analysis.

A Study on the Inner tank Seismic Analysis Model for Calculation of Seismic Forces of LNG Storage Tank (LNG저장탱크 지진력 산정을 위한 내부탱크 지진해석 모델에 관한 연구)

  • Kim, Miseung;Lee, Kangwon;Kim, Junhwi;Yoon, Ihnsoo
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.58-63
    • /
    • 2013
  • LNG(Liquefied Natural Gas) has been considered as the green energy. Thus, the demand of natural gas is keep increasing around the world, and various studies are actively under progress about the LNG storage tank. To calculate the seismic forces of actual LNG storage tank, FEM model has to include inner tank, outer tank, pile and soil to implement the interaction between structure and ground. So, this paper is represent the study about inner tank model of three cases using Malhotra method in EN 1998-4(European Standard). The results of calculation were compared, and the most suitable to inner tank model was suggested.

Assessment of Response Spectrum by Dynamic Centrifuge Test for the Pile Foundation into the Sand (동적 원심모형실험에 의한 사질토에 근입된 말뚝지지 기초의 응답 스펙트럼 분석)

  • Park, Yong-Boo;Park, Jong-Bae;Kim, Sang-Yeon;Kim, Dong-Soo
    • Land and Housing Review
    • /
    • v.5 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • Site coefficient and amplification factor of current domestic Seismic Design Code (KBC-2009) have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. Accordingly, in this study dynamic centrifugal test and analysis for pile foundation into sand and upper structure were achieved. and the response spectrums of free surface and basement were compared with each other. Within the period 1 sec., the measured spectral acceleration of free surface and basement was bigger than the design spectral acceleration of SC and SD site. However the measured spectral acceleration of free surface and basement for the period over 1.5 sec. was smaller than the design spectral acceleration of SC site. There was no severe difference of spectral acceleration according to the upper structure, embedded depth of foundation and free surface conditions. Consequently, normal domestic apartment housing for the period range over 1.5sec. could be design more economically applying these test result.

Analysis of the Correlation between the velocity speed of High-Speed Railways and the Suppressing Effect of lateral Displacement of retaining wall according to the Arrangement of Stabilizing Piles (억지말뚝의 배치에 따른 흙막이의 수평변위 억제효과와 고속철도의 속도와의 상관성 분석)

  • Son, Su-Won;Im, Jong-Chul;Seo, Min-Su;Hong, Seok-Woo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • In urban areas, structures are installed deep underground in the lower part of the structure to utilize space. Therefore, a retaining wall is used to prevent earth pressure from the ground when constructing a structure. Due to the development of construction technology, retaining wall applied to excavation work are used to prevent danger such as falling rocks and landslides in temporary facilities when construction or retaining walls are installed. In general, the application of a retaining wall to a temporary facility during the embankment construction is the case of expanding an existing roads or railways. Therefore, it is necessary to study the retaining wall applied to the embankment construction such as the double-track site of the high-speed railway. In this study, two types of common one row H-pile retaining wall and two types of IER retaining wall were analyzed, and the stability of the retaining wall applied to the construction of double-track of the high-speed railway was analyzed. The earth retaining wall is a construction method that combines forced pile applied to the stabilization of the slope with the wall of the earth retaining wall. As a result of the analysis, the IER retaining wall had maximum lateral displacement of 19.0% compared to the type with H-plie installed only in the front while dynamic load was applied. In addition, the slower the speed of high-speed railway, the more displacement occurred, and the results show that more caution is needed when designing the ground in low-speed sections.

Assessment of Response Spectrum by Dynamic Centrifuge Test for the Pile Foundation into the Clay (동적 원심모형실험에 의한 점성토 지반에 근입된 말뚝지지 기초의 응답 스펙트럼 분석)

  • Kim, Sang-Yeon;Park, Jong-Bae;Park, Yong-Boo;Kim, Dong-Soo
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.115-120
    • /
    • 2014
  • Site coefficient and amplification factor of current domestic Seismic Design Code (KBC-2009) have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. Accordingly, in this study dynamic centrifugal test and analysis for pile foundation into clay were achieved. and the response spectrums of free surface and basement were compared with each other. Within the period 1sec., the measured spectral acceleration of free surface and basement was bigger than the design spectral acceleration of SC and SD site. However the measured spectral acceleration of free surface and basement for the period over 1.5sec. was smaller than the design spectral acceleration of SC site. There was no severe difference of spectral acceleration according to the upper structure, embedded depth of foundation and free surface conditions. Consequently, normal domestic apartment housing for the period range over 1.5sec. could be design more economically applying these test result.

Calculation of the Earthquake Vulnerability of the Bridge Foundation Considering the Characteristics of the Ground (지반의 특성을 고려한 교량기초의 지진취약도 산정)

  • Lee, Donggun;Song, Kiil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.2
    • /
    • pp.13-23
    • /
    • 2022
  • The ground-structure interaction of the bridge foundation has been pointed out as a major factor influencing the behavior of the bridge during earthquakes. In this study, the effect of characteristics of ground and bridge foundation on the earthquake vulnerability is investigated. From the pseudo-static analysis, it is confirmed that non-linearity becomes lesser and horizontal load becomes greater when surcharge is considered. It is also found that as the ground worsens and the size of foundation decreases, horizontal load reduces. To derive reasonable structural model for bridge foundation, fragility curve is obtained considering four conditions (fixed condition, equivalent linear condition, non-linear without surchage condition, non-linear with surcharge condition) and compared. Seismic analysis is performed on single pier with Opensees. From the earthquake vulnerability analysis, it is found that shallow foundation can be assumed as fixed condition. In conservative approach, stiffness of spring can be obtained based on Korean highway bridge design code for pile foundation which can consider the ground condition.