• 제목/요약/키워드: Seismic Margin

검색결과 120건 처리시간 0.022초

Architecture of Continental Rifting in the South Korea Plateou: Constraints to the Evolution of the Eastern Korea Margin and the Opening of the East Sea (Japan Sea)

  • 김한준;주형태;유해수
    • 지구물리
    • /
    • 제9권3호
    • /
    • pp.189-197
    • /
    • 2006
  • The Korea Plateau is a continental fragment rifted and partially segmented from the Korean Peninsulaat the initial stage of the opening of the East Sea (Japan Sea). We interpreted marine seismic profiles from the South Korea Plateau in conjunction with swath bathymetric to investigate processes of con-tjnental rifting and separation of the southwestern Japan Arc. The SouU-i Korea Plateau preserves funda-mental elements of rift architecture comprising a seaward succession of a rift basin and an uplifted rift flank passing into the slope, typical of a passive continental margin. Two distinguished rift basins (Onnuri and Bandal Basins) in the South Korea Plateau are bounded by major synthetic and smaller antithetic faults, creating wide and symmetric profiles. The large-offset border fault zones of these basins have convex dip slopes and demonstrate a zig-zag arrangement along strike. Rifting was primarily controlled by normal faulting resulting from extension orthogonal to the inferred line of breakup along the base ofthe slope rather U-ian strike-slip deformation. Two extension direcdons for rifdng are recog-nized; U-ie Onnuri Basin was rifted in U-ie EW direction; U-ie Bandal Basin in U-ie EW and NW-SE directions, suggesting two rift stages. We interpret that the E-W direction represents initial rifting at the inner margin; while the Japan Basin widened, rifting propagated repeatedly from the Japan Basin to the southeast toward the Korean margin but could not penetrate the strong continental lithosphere of the Korean Shield and changed direction to the south, resulting in E-W extension to create the rift basins at the Korean margin. The Hupo Basin to the south of the Korea Plateau is estimated to have formed in this process. The NW-SE direction probably represents the direction of rifting orthogonal to the inferred line of breakup along the base of the slope of the South Korea Plateau; after breakup the southwestern Japan Arc separated in the SE direction, indicating a response to tensional tectonics associated with the subduction of the Pacific Plate in the NE direction. We suggest that structural evolution of the eastern Korean margin can be explained by the processes occurring at the passive continental margin.

  • PDF

Collapse response assessment of low-rise buildings with irregularities in plan

  • Manie, Salar;Moghadam, Abdoreza S.;Ghafory-Ashtiany, Mohsen
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.49-71
    • /
    • 2015
  • The present paper aims at evaluating damage and collapse behavior of low-rise buildings with unidirectional mass irregularities in plan (torsional buildings). In previous earthquake events, such buildings have been exposed to extensive damages and even total collapse in some cases. To investigate the performance and collapse behavior of such buildings from probabilistic points of view, three-dimensional three and six-story reinforced concrete models with unidirectional mass eccentricities ranging from 0% to 30% and designed with modern seismic design code provisions specific to intermediate ductility class were subjected to nonlinear static as well as extensive nonlinear incremental dynamic analysis (IDA) under a set of far-field real ground motions containing 21 two-component records. Performance of each model was then examined by means of calculating conventional seismic design parameters including the response reduction (R), structural overstrength (${\Omega}$) and structural ductility (${\mu}$) factors, calculation of probability distribution of maximum inter-story drift responses in two orthogonal directions and calculation collapse margin ratio (CMR) as an indicator of performance. Results demonstrate that substantial differences exist between the behavior of regular and irregular buildings in terms of lateral load capacity and collapse margin ratio. Also, results indicate that current seismic design parameters could be non-conservative for buildings with high levels of plan eccentricity and such structures do not meet the target "life safety" performance level based on safety margin against collapse. The adverse effects of plan irregularity on collapse safety of structures are more pronounced as the number of stories increases.

Seismic Retrofit Assessment of Different Bracing Systems

  • Sudipta Chakraborty;Md. Rajibul Islam;Dookie Kim;Jeong Young Lee
    • Architectural research
    • /
    • 제25권1호
    • /
    • pp.1-9
    • /
    • 2023
  • Structural ageing influences the structural performance in a negative way by reducing the seismic resilience of the structure which makes it a major concern around the world. Retrofitting is considered to be a pragmatic and feasible solution to address this issue. Numerous retrofitting techniques are devised by researchers over the years. The viability of using steel bracings as retrofitting component is evaluated on a G+30 storied building model designed according to ACI318-14 and ASCE 7-16. Four different types of steel bracing arrangements (V, Inverted V/ Chevron, Cross/ X, Diagonal) are assessed in the model developed in commercial nu-merical analysis software while considering both material and geometric nonlinearities. Reducing displacement and cost in the structures indicates that the design is safe and economical. Therefore, the purpose of this article is to find the best bracing system that causes minimum displacement, which indicates maximum lateral stiffness. To evaluate the seismic vulnerability of each system, incremental dynamic analysis was conducted to develop fragility curves, followed by the formation of collapse margin ratio (CMR) as stipulated in FEMA P695 and finally, a cost estimation was made for each system. The outcomes revealed that the effects of ge-ometric nonlinearity tend to evoke hazardous consequences if not considered in the structural design. Probabilistic seismic and economic probes indicated the superior performance of V braced frame system and its competency to be a germane technique for retrofitting.

비선형 증분동적해석을 통한 철골 중간모멘트 골조의 붕괴성능 평가 (Collapse Capacity Evaluation of Steel Intermediate Moment Frames Using Incremental Dynamic Analysis)

  • 신동현;김형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권2호
    • /
    • pp.9-20
    • /
    • 2014
  • 철골 중간모멘트골조는 강한 지반운동에 대하여 적합한 저항능력을 확보하기 위한 지진력저항시스템으로서 일반적으로 사용되고 있다. 하지만 국내의 대다수 중 저층 철골건축물은 내진설계가 도입되기 이전에 건설되었거나 현재의 내진설계기준의 요구조건을 준수하지 않은 것들로, 이러한 건물들이 가지는 내진성능에는 의문점이 존재한다. 이와 같은 문제점의 인식에 기반하여 본 연구에서는 국내 철골 중간 모멘트골조의 내진성능에 대한 정량적 제시를 목표로 우선 층수 종류, 지진에 대한 보유내력, 부재 연성도, 제진장치의 유무를 변수로 하여 표본 건물을 설계하였다. 표본 건물의 내진 성능과 붕괴 매커니즘은 비선형 정적해석과 증분동적해석으로부터 획득한 붕괴여유비와 붕괴확률을 이용하여 분석하였다. 해석결과를 통하여 현행 국내기준에 따라 내진설계된 신축건물은 설계지진에 대해 충분한 내진성능을 가졌으며, 이에 반해 구조부재의 연성저감이 발생하거나 낮은 설계 밑면전단력에 대한 저항력을 가진 기존건물의 경우에는 높은 붕괴확률을 가지며 목표로 한 내진성능을 만족시키지 못하는 것으로 나타났다. 이와 같은 내진성능을 충족시키지 못하는 내진설계 도입 이전의 건물에 대해서 에너지 소산장치를 통해 보강하게 되면 장치의 에너지 소산능력뿐만 아니라 소성힌지의 재분배를 통해 붕괴확률 및 내진성능이 신축건물 수준으로 향상되었다.

Seismic performance assessment of the precast concrete buildings using FEMA P-695 methodology

  • Adibi, Mahdi;Talebkhah, Roozbeh
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.55-67
    • /
    • 2022
  • The precast reinforced concrete frame system is a method for industrialization of construction. However, the seismic performance factor of this structural system is not explicitly clarified in some existing building codes. In this paper, the seismic performance factor for the existing precast concrete building frame systems with cast-in-situ reinforced shear walls were evaluated. Nonlinear behavior of the precast beam-column joints and cast-in-situ reinforced shear walls were considered in the modeling of the structures. The ATC-19's coefficient method was used for calculating the seismic performance factor and the FEMA P-695's approach was adopted for evaluating the accuracy of the computed seismic performance factor. The results showed that the over-strength factor varies from 2 to 2.63 and the seismic performance factor (R factor) varies from 5.1 to 8.95 concerning the height of the structure. Also, it was proved that all of the examined buildings have adequate safety against the collapse at the MCE level of earthquake, so the validity of R factors was confirmed. The obtained incremental dynamic analysis (IDA) results indicated that the minimum adjusted collapse margin ratio (ACMR) of the precast buildings representing the seismic vulnerability of the structures approximately equaled to 2.7, and pass the requirements of FEMA P-695.

Seismic fragility analysis of base isolation reinforced concrete structure building considering performance - a case study for Indonesia

  • Faiz Sulthan;Matsutaro Seki
    • Structural Monitoring and Maintenance
    • /
    • 제10권3호
    • /
    • pp.243-260
    • /
    • 2023
  • Indonesia has had seismic codes for earthquake-resistant structures designs since 1970 and has been updated five times to the latest in 2019. In updating the Indonesian seismic codes, seismic hazard maps for design also update, and there are changes to the Peak Ground Acceleration (PGA). Indonesian seismic design uses the concept of building performance levels consisting of Immediate occupancy (IO), Life Safety (LS), and Collapse Prevention (CP). Related to this performance level, cases still found that buildings were damaged more than their performance targets after the earthquake. Based on the above issues, this study aims to analyze the performance of base isolation design on existing target buildings and analyze the seismic fragility for a case study in Indonesia. The target building is a prototype design 8-story medium-rise residential building using the reinforced concrete moment frame structure. Seismic fragility analysis uses Incremental Dynamic Analysis (IDA) with Nonlinear Time History Analysis (NLTHA) and eleven selected ground motions based on soil classification, magnitude, fault distance, and earthquake source mechanism. The comparison result of IDA shows a trend of significant performance improvement, with the same performance level target and risk category, the base isolation structure can be used at 1.46-3.20 times higher PGA than the fixed base structure. Then the fragility analysis results show that the fixed base structure has a safety margin of 30% and a base isolation structure of 62.5% from the PGA design. This result is useful for assessing existing buildings or considering a new building's performance.

포텐셜자료를 이용한 한반도 동해 대륙주변부의 지각구조에 관한 연구 (A study on the crustal structure of the continental margin in the East Sea along the Korea Peninsula using potential data)

  • 김창환;유이선;박찬홍;석동우
    • 지구물리
    • /
    • 제10권1호
    • /
    • pp.13-25
    • /
    • 2007
  • 본 연구에서는 중력, 자력자료와 기존 탄성파 연구결과를 이용한 역산 및 모델링을 통하여 모호면의 심도 변화 및 대륙붕에서 울릉분지로 이어지는 지역의 지각구조를 연구하는데 목적이 있다. 연구지역의 후리에어중력이상은 해저지형 효과를 잘 반영하며 나타나고 있다. 부게중력이상은 울릉분지 중심부로 갈수록 증가하고 있는데 이는 울릉분지 하부의 모호면이 상승되어 있다는 것을 암시한다. 자기이상의 특징은 대륙주변부를 따라서 북동방향으로 양의 자기이상이 존재하며 울릉분지로 가면서 감쇠한다. 아날니틱 신호를 보면 후포뱅크에서 소규모의 이상이 존재하고 대륙사면 지역에서는 강한 이상대가 분포되어 있다. 후포뱅크에서 나타나는 이상은 이곳이 화산관입으로 융기된 지역인 것을 암시한다. 대륙사면에서 양의 자기이상은 SDR(seaward dipping reflectors)의 존재를 지시하며 탄성파 단면에서 나타나는 SDR의 위치와 일치한다. 부게중력이상에 대한 역산과 2차원 중력 모델링 결과에서 나타난 모호면의 변화는 대륙주변부에서 울릉분지쪽으로 갈수록 모호면의 깊이가 상승하였으며 OBS 속도구조에서 나온 결과와 좋은 일치를 보인다. 2차원 중력 모델링 결과 대륙지각 하부에는 magmatic underplating zone이 존재를 암시하며 이는 이 지역에서 리프팅이 일어났을 가능성을 지시한다.

  • PDF

내풍설계된 초고층 철골중심가새골조의 지진응답 해석 (Seismic Response Analysis of Wind-Designed Concentrically Braced Steel Highrise Buildings)

  • 이철호;김선웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.60-67
    • /
    • 2004
  • The designer of a tall building even in moderate and low seismic regions should, in finalizing the desist consider the probable impact of the design basis earthquake on the selected structural system. In this study, seismic response analysis was conducted to evaluate the seismic performance of concentrically braced steel highrise buildings which were designed only for governing wind loading under moderate seismicity. The main purpose of this analysis was to see if the wind design would create a system whose elastic capacity clearly exceeds the probable demand as suggested by the design basis earthquake. The strength demand-to-capacity study revealed that the wind-designed steel highrise buildings with the aspect ratio of larger than five can withstand the design basis earthquake elastically by a sufficient margin due to the system over-strength resulting from the wind-serviceability criterion. The maximum story drift demand from the design basis earthquake was just 0.25% (or half the limit of Immediate Occupancy performance level in FEMA 273)

  • PDF

울릉분지 남서연변부의 탄성파 시퀀스 층서분석 (Seismic Sequence Stratigraphy in the Southwestern Margin of the Ulleung Basin, East Sea)

  • 최동림
    • 한국석유지질학회지
    • /
    • 제6권1_2
    • /
    • pp.1-7
    • /
    • 1998
  • 울릉분지 남서연변부의 다중채널 탄성파단면도를 이용하여 중기에서 말기 마이오세동안의 시퀀스 층서분석을 정밀 분석 하였다. 해퇴층서는 오랜 융기되고 변형된 하부층을 기저로 한 해침층서 위에 발달하였다. 뚜렷한 응축층이 해침과 해퇴층서사이를 구분 짓는다. 해침층서는 하부의 융기되고 변형된 지층위로 상향걸침한다. 해퇴층서는 구분 가능한 저해수준, 고해수준, 그리고 해침 체계역으로 구성된 여섯 개의 전진형 퇴적 시퀀스를 포함한다. 대부분의 퇴적 시퀀스는 분지선상지, 사면선상지, 그리고 전진복합체로 이루어진 저해수준 체계역이다. 잠재적인 석유 저류층은 분지선상지의 사암, 사면 선상지의 해저수로 충진 사암과 오버뱅크의 사암, 그리고 대륙붕지역의 침식곡 충진 사암들이다. 또한 해침퇴적층서내 천해사암층도 유망하다. 성공적인 탐사활동을 위해 연구 주변지역에 대한 정밀 시퀀스 층서분석, 탄성파 자료의 재처리, 그리고 3-D탄성파 탐사의 실시를 제안한다.

  • PDF

다이아그리드 구조 시스템의 내진성능계수 평가 (Evaluation of Seismic Performance Factors of Diagrid Structural System)

  • 김경환;주영규;김상대
    • 한국강구조학회 논문집
    • /
    • 제22권3호
    • /
    • pp.229-239
    • /
    • 2010
  • 새롭게 제안된 다이아그리드 구조 시스템은 경사진 기둥을 통해 구조물의 중력하중과 횡력을 모두 저항하는 시스템이다. 하지만 현재 내진설계 기준은 새로운 구조시스템에 대한 적절한 반응수정계수가 없다. 이에 새로운 시스템의 반응수정계수를 포함한 내진설계시 고려되는 내진성능계수들을 산정하기 위해 ATC-63(안)이 새롭게 제안되었다. ATC-63(안)에서는 구조 시스템의 여러 변수에 의해 다른 값을 가지게 되는 반응수정계수를 보완하기 위해 붕괴여유비를 함께 고려하여 건물의 내진성능을 판단한다. 본 논문에서는 4층에서 36층의 서로 다른 높이의 대각가 새 구조물을 설계하여 ATC-63(안)의 방법론에 따라 비선형정적해석과 동적해석을 통해 대각가새 구조의 내진성능계수를 평가하였다.