• 제목/요약/키워드: Seismic Integrity

검색결과 143건 처리시간 0.027초

합벽구간 및 지하구조물 외벽에 사용되는 방수재료 내진 성능실험방법 (Anti-Seismic Evaluation of Waterproofing Materials for Positive-Side wall and pile wall of Underground Concrete Structures)

  • 오규환;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.210-211
    • /
    • 2021
  • This study introduces and demonstrates the application of an experimental regime for anti-seismic performance evaluation of waterproofing materials to used for concrete pile walls. Concrete pile walls are subject to high degree of seismic load, and the occurring stress can affect the waterproofing integrity of the structure, but there is currently no existing methodology or standard for evaluating this property of waterproofing materials. To propose and conduct this evaluation, a new testing apparatus was designed and manufactured intended to be able to test an installed waterproofing material's seismic resistance performance.

  • PDF

2400MPa 긴장재가 적용된 포스트텐션 프리캐스트 콘크리트 보-기둥 접합부의 반복가력실험 (Reversed Cyclic Loading Test of Post-Tensioned Precast Concrete Beam-Column Connections with 2400MPa Prestressing Strands)

  • 황진하;최승호;이득행;김강수;우운택
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.45-52
    • /
    • 2017
  • The precast concrete (PC) method has many advantages in fast construction, quality control, etc. In domestic construction market, however, its application has been quite limited because of the concerns about structural integrity and seismic performances due to the discrete connections between precast concrete members. By applying the post-tensioning method, the precast beam-column connection can be well tightened, allowing improved structural integrity, and proper seismic performances can be also achieved. In this study, reversed cyclic tests have been conducted on the beam-column connection specimens, where the test variables included the compressive strength of grouting mortar and the tensile strengths of prestressing strands, based on which their seismic performances have been examined in detail. The post-tensioned PC beam-column connections showed good seismic performances comparable to that of the monolithic reinforced concrete connection specimen. When 2400 MPa prestressing strands are applied to the beam-column connection, it is preferable to adjust the prestress level similar to that applied for the 1860 MPa prestressing strands to avoid premature local crushing failures at the beam-column connections.

원자력발전소 보호시스템 캐비넷의 내진검증 (Seismic Qualification of Plant Protection System Cabinet for Nuclear Power Plant)

  • 정명조;박근배;황원걸
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.148-155
    • /
    • 1992
  • A method to verify seismic qualification of the plant protection system cabinet for a nuclear power plant is presented. A finite element model of the cabinet is developed and correlated to the dynamic properties observed during in-situ vibration test of the actual structure. The results of the modal analysis provide insight into the fundamental dynamic properties of the structure. Techniques for verifying structural integrity and operability are exemplified by summarizing response spectrum and time history analyses of the structure.

  • PDF

KALIMER-600 지진해석모델 개발 및 시간이력 지진응답해석 (Development of Seismic Analysis Model and Time History Analysis for KALIMER-600)

  • 구경회;이재한
    • 한국지진공학회논문집
    • /
    • 제11권3호
    • /
    • pp.73-86
    • /
    • 2007
  • 본 논문에서는 제4세대 소듐냉각고속로(Sodium-Cooled Fast Reactor)의 후보 노형으로 선정된 KALIMER-600에 대한 단순 지진해석모델을 개발하고 시간이력 지진응답해석을 수행하여 수평 면진설계(Seismic Isolation) 기술이 적용된 원자로건물의 주요기기 및 구조물에서의 지진응답 성능을 분석하였다. 개발된 단순 지진해석모델은 원자로건물, 원자로시스템, 주요 기기, 중간 열전달계통 배관, 그리고 면진장치를 포함하며 각각은 상세 유한요소해석을 통한 동특성 비교검증을 통하여 정확성을 검증하였다. 안전정지기준 0.3g의 설계인공지진 하중에 대한 시간이력 지진응답해석을 수행하여 면진설계와 비면진 설계조건에 따른 원자로 주요 부위에서의 층응답스펙트럼을 비교분석한 결과 KALIMER-600의 면진성능이 우수한 것으로 나타났다.

원자력 발전소용 펌프의 내지진해석에 관한 연구 (A Study on the Seismic Analysis of Nuclear Power Plant Pumps)

  • 서영수;손효석;전형식;정희택
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.13-18
    • /
    • 1999
  • The pump safety related to the functions in nuclear power plants must be designed to meet load conditions considering seismic requirements. In order to satisfy both structural integrity and operability of these pumps, the initial step in the seismic qualification is to establish the resonant frequencies of the structure. Applications we made to the design of the vertical and horizontal type pump. Computational results are analyzed with respect to the dynamic characteristics and are compared to the expected design requirements.

  • PDF

구형 면진유체저장조의 지진시 거동해석 (Seismic Response Analysis of Rectangular Tank with Base-Isolation System)

  • 전영선;최인길;황신일;김진웅
    • 전산구조공학
    • /
    • 제8권1호
    • /
    • pp.107-113
    • /
    • 1995
  • 사용후핵연료 저장조는 지진하중에 대하여 운영기간중 자체의 구조적 건전성 및 저장된 사용후핵료의 안전성을 확보할 수 있어야 한다. 본 연구에서는 LRB 면진장치를 설치한 사용후핵연료 면진저장조의 지진시 거동특성을 파악하기 위하여 서로 다른 특성을 갖는 두종류의 지진에 대하여 지진해석을 하여 그 결과를 비면진 저장조에서의 응답과 비교하였다. 면진장치를 사용함으로써 지진시 상부구조로 전달되는 지진력과 응답을 크게 감소시켜 저장조와 저장된 사용후액연료의 안전성 확보에 유리한 것으로 나타났다.

  • PDF

발전소 배관계의 내진해석 (Seismic Analysis of Power Plant Piping System)

  • 김정현;이영신;김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.480-485
    • /
    • 2011
  • In this study, the seismic analysis of power plant piping system was performed using finite element model. This study was performed by ANSYS 12.1. For qualification of power plant piping system, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. The maximum stresses of power plant piping system were 166 MPa under OBE condition and 281 MPa under SSE condition. Thus, it can shown that the structural integrity of tpower plant piping system has a stable structure for seismic load conditions.

  • PDF

지진 및 냉각재상실사고시의 핵연료집합체 응력해석에 관한 연구 (A Study on the Fuel Assembly Stress Analysis for Seismic and Blowdown Events)

  • Kim, Il-Kon
    • Nuclear Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.552-560
    • /
    • 1993
  • 지진 및 냉각재상시사고시 핵연료집합체의 건전성 확인은 원자로심모델의 핵연료집합체 집중질량모델을 이용하여 지지격자에 발생한 충격 해석치와 동적좌굴시험치와의 비교를 통해 사고시의 핵연료집합체 건전성을 평가하여 왔다. 그러나 이 방법은 사고시 핵연료집합체 부품별 설계 요구사항 만족여부를 평가하는데 미흡하여 본 연구에서는 지진 및 냉각재상실사고시 핵연료집합체 구조적건전성 평가를 위한 수평방향 핵연료집합체 응력해석모델을 개발하였다. 이를 위해 첫번째 단계로써 원자로심모델의 해석 결과인 각 절점에서의 변위와 회전각으로부터 응력을 계산하고 가장 큰 응력을 갖는 핵연료를 찾아내는 MAIN이라는 전산프로그램을 개발하였다. 그리고 다음단계로써 이 .프로그램에서 구한 핵연료집합체 변위와 회전각을 이용하여 핵연료집합체의 주요부품에 가해지는 응력을 계산하기 위한 핵연료집합체 응력해석모델을 개발하였다. 이 모델은 집합체주요부품인 안내관과 연료봉을 3차원보요소로, 지지격자스프링을 선형 및 회전스프링으로 각각 모델링 하였으며, MAIN 프로그램의 출력인 집합체의 변위를 구속조건으로 사용하였다. 또한, 개발된 프로그램과 응력해석모델을 이용하여 하나의 적용 예로써 임의의 지진하중하에서 16$\times$16형 핵연료집합체에 대한 응력해석을 수행하였다. 이 모델을 개발하므로써 지진 및 냉각재상실사고시 핵연료집합체 설계용구사항 만족여부를 평가할 수 있는 기틀을 마련하였다.

  • PDF

연구용 원자로 이차정지구동장치 수력시스템의 내진검증 (Seismic Qualification Test for SSDM Hydraulic System of Research Reactor)

  • 김상헌;김경호;선종오;조영갑;정택형;김정현;이관희
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.23-29
    • /
    • 2016
  • The Second Shutdown Drive Mechanism (SSDM) provides an alternate and independent means of reactor shutdown. The Second Shutdown Rods (SSRs) of SSDMs are poised at the top of the core by the hydraulic force driven from a hydraulic system during normal operation. The rods drop by gravity when a trip is commended by a Reactor Protection System, Alternate Protection System, Automatic Seismic Trip System or operator by means of power off solenoid valves of hydraulic system. This paper describes the test results of seismic qualification of a prototype SSDM hydraulic system to demonstrate that its structural integrity and operability (functionality) are maintained during and after seismic excitations, that is, an adequacy of the SSDM design. From the results, this paper shows that the SSDM hydraulic system satisfies all its design requirements without any malfunctions during and after seismic excitations.