• 제목/요약/키워드: Seismic Design Guideline

검색결과 41건 처리시간 0.023초

시설물별 지진응답계측기 설치 운영에 관한 기준 및 지침 (Standard and Guideline for Installation and Management of Earthquake Instruments for Each Facilities)

  • 김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.458-467
    • /
    • 2000
  • The standard of performance-based seismic design accepted by Ministry of Construction and Transport requires to install and manage earthquake instruments for the facilities of seismic category I and to acquire earthquake response data of these facilities at earthquake events. So detailed standard and guideline for installation and management of earthquake instruments for each facilities according to the seismic design standard are getting ready. This paper presents the part of installation locations of sensors in that detaile standard and guideline.

  • PDF

액체금속로 면진설계를 위한 지침서 개발 (Development of Guidelines for seismic isolation Design of LMR)

  • 유봉;구경회;이재한
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.147-154
    • /
    • 1998
  • The purpose of this paper is to propose the draft guidelines of seismic isolation design of Liquid Metal Reactor (LMR) using high damping laminated rubber bearings. The scopes of guidelines include design requirements of a seismically isolated system and components, seismic isolator, isolation system, interface system between seismic isolation and non-seismic isolation part, qualification and acceptance tests of seismic isolator, seismic isolation reliability, and seismic safety and monitoring system. Proposed guidelines shall be revised to extend to general design guideline for nuclear facilities by further research and discussions.

  • PDF

변전설비 내진설계를 위한 유사공진법의 적용성 검증 (Validation of Practical Applicability of Pseudo-resonance Method for Seismic Design of Substation Equipment)

  • 조양희;조성국;박형기;권경일
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.49-57
    • /
    • 2003
  • Lately, a guideline for seismic design of electric substation facilities has been newly prepared and issued. The guideline adopts a new simplified dynamic analysis technique called "pseudo-resonance method" from the design code of Japan. The method can effectively consider resonance effect of structural system during earthquake motion. However, reliability and practical applicability of the method have not been fully guaranteed under the different seismic and engineering situations in Korea. This paper presents a validation study of the pseudo-resonance method for practical seismic analysis. For this purpose, various parametric studies have been performed using recorded earthquake motions and idealized substation equipment models. The results showed that the pseudo-resonance method can be effectively used for the practical seismic design of substation facilities in Korea.

  • PDF

KDS 41 17 00에 따라 설계된 저층 필로티 건물의 지진 취약도 (Seismic Fragility of Low-rise Piloti Buildings Designed According to KDS 41 17 00)

  • 주창혁;김태완
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.49-58
    • /
    • 2022
  • The 2017 Pohang earthquake caused severe damage to low-rise piloti buildings. The damage was caused mainly by column shear failure, and some core walls were as well. The damaged piloti buildings in Pohang City could be relieved if they were designed correctly according to the standards at that time. However, the post-earthquake investigation revealed design, construction, and permission problems. To solve the problems, the Piloti Building Structure Design Guidelines that include strict specifications were published in 2018. Separately, KDS 41 17 00, the seismic design standard for buildings, was enacted in 2019 and it included the guideline contents. Therefore, at least after the publication of the guidelines, piloti buildings, designed by the standard and guidelines, can be expected to possess better seismic performance than existing piloti buildings. To confirm this, the probability of exceedance for several damage state thresholds was estimated for existing and designed piloti buildings. As a result, the probability of damage of designed piloti buildings was very low compared to existing ones. Consequently, it was confirmed that the guideline and standard adequately supplement the structural fragility of existing piloti buildings.

블록식 보강토 옹벽의 내진설계에 관한 비교연구 (Comparative Study on Seismic Design of Soil-Reinforced Segmental Retaining Walls)

  • 유충식
    • 한국지반공학회논문집
    • /
    • 제16권4호
    • /
    • pp.51-61
    • /
    • 2000
  • 본 논문에서는 블록식 보강토 옹벽의 내진 설계/해석 개념을 고찰하고 현재 적용되고 있는 대표적인 설계기준이라고 할 수 있는 NCMA 및 FHWA 설계기준을 비교.분석하였다. 그 결과 NCMA와 FHWA 설계기준은 동일한 외적안정성 검토모형을 적용함에도 불구하고 지진계수 산정 기준의 차이로 인해 외적안정성 검토결과가 상이하게 나타나며, 전반적으로 FHWA 설계기준이 다소 보수적인 결과를 주는 것으로 나타났다. 한편, NCMA 설계기준에서 채택하고 있는 내적안정성 검토방법에 의하면 지진하중으로 인한 유발인장력의 증가 정도가 벽체 상단부로 갈수록 현저히 크게 나타나므로 상단부에서의 보강재 수를 증가시켜야할 뿐만 아니라 충분한 인발저항력 확보를 위해 정착길이를 증가시켜야 하나 FHWA 설계기준은 하단부 보강재에 동적하중을 재분배하는 모형을 채택하고 있으므로 NCMA 설계기준과는 상반된 결과를 도출하는 것으로 나타났다. 본 연구의 결과는 효율적인 설계기준의 개발을 위해 보다 종합적이고 체계적인 연구의 필요성을 제시하고 있다.

  • PDF

학교 건축물 내진보강 시공현장 관리를 위한 가이드라인 개발 및 적용에 관한 연구 (Development and Application of Guideline for Construction Management of School Building Seismic Retrofit)

  • 황은아;이병호;박구병
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.36-37
    • /
    • 2020
  • The government seismic retrofit project for educational facilities is progressing more actively due to the 2018 Pohang earthquake. It is most important that seismic retrofit constructions are conformed to seismic design to achieve the desired purpose of the project as reduce direct damage caused by earthquake. However, the construction supervision system is not mandatory for the retrofit construction site of small buildings including school buildings according to applicable laws and regulations. The purpose of this study was to develop a guide for constructions management of school building seismic retrofit. In order to achieve this goal, the survey on the construction site was conducted and various problems related to the construction site of school building seismic retrofit was derived Additionally, the systematic checklist was presented according to the user and seismic reinforcement method.

  • PDF

소방설비 내진설계에 관한 각국 기준 비교 연구 (Review of Code Provisions on Seismic Design of Fire Protection System)

  • 이현진;신이철;이재영;서동구;한병찬;김재환;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.238-241
    • /
    • 2008
  • In this paper, provisions related with the seismic design and equipments of fire protection system are being considered. The provisions from various international codes on seismic design fire protection system were reviewed. The codes, reviewed are, Japanese code, NFPA guideline and Korean code. It is noted that all the codes excepted to korean code consider earthquake effect to evaluate seismic forces and behaviors. But, korean provision are not covered in seismic response in all. A brief description on limitations in korean code is also presented.

  • PDF

차세대 내진 설계 규준을 위한 계수 결정 방법 (Method of Determination of Seismic Design Parameters for the Next Generation of Design Provisions)

  • 한상환;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.88-96
    • /
    • 1995
  • Seismic design provisions in Korea has developed based on seismic provisions in United States (e.g., ATC 3-06). Current seismic design provisions in U .S. is moving toward adopting enhanced concept for design. Federal Emergence Management Agency (FEMA) Provides the NEHRP recommended Provisions for the Development of Seismic Regulations for New Buildings which can be used as a source document for use by any interested members of the building community. Current seismic design provisions in U .S. generally use a uni-level force. These provisions can not be satisfied if the limit state design is concerned. Limit state can be defined as a state causing undesirable performance o( a structure (e .g., serviceability, ultimate, buckling, etc.). Even if there are provision for controlling drift by two levels, it is still difficult to satisfy limit states using uni-level force. Architectural Institute of Japan (AIJ) uses a hi-level forces Int seismic loadings which can satisfy serviceability and ultimate limit state. However, the seismic parameters used in AIJ guideline are basically determined by subjective manner of code committee member and professions. These parameters need to be determined based on target quantities (target reliability, target energy dissipation, target displacement, target stress level, etc.). This study develops the method to determine the sesmic design parameters based on a certain taget level. Reliability is used as a target level and load factors in ANSI/ASCE 7-88 are selected as design parameters to be determined.

  • PDF

미국의 차세대 내진설계 개념의 발전 동향 (Development of Performance-Based Seismic Design in U.S.A)

  • 이한선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.44-53
    • /
    • 1998
  • The objective of this paper is to review the current state of practice in the seismic codes in the U.S.A. and to investigate its trend in the development of performance-based seismic design for the 21st century. This study is supposed to be eventually utilized as a basis material to establish the new seismic code appropriate in our country having the moderate seismic hazard. To do this, the history of the seismic codes in U.S.A. is first briefly investigated and then the critical review on the recent codes is made. Finally, the conceptual framework of the performance-based seismic design and the development of the guideline documents to implement this to the rehabilitation of existing building structures are introduced.

  • PDF

전단벽 구조시스템의 내진성능평가 지표 산정 (Calculation of Seismic Capacity Evaluation Index of Shear Wall System)

  • 박태원;나승욱;우운택;정란
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.223-230
    • /
    • 2002
  • Earthquake resistance design has been developed many countries like Japan, USA, Mexico, New Zealand etc., which countries have experienced many earthquakes. Nowadays, earthquake resistance design has come into worldwide use. In Korea, the seismic design regulations have been established since 1988 in order to minimize the economic losses. Recently performance based design method has been adopted as a new Earthquake resistance design method. These regulations, however, are targeted for newly constructed buildings, In Korea, there are no regulations for existing buildings that built before 1988. On the other hand, in Japan and USA, the seismic performance evaluation is coded. In Japan, the evaluation index which can measure seismic performance has been made. So, we need to prepare the regulations that evaluate the seismic performance, furthermore proper retrofitting design guideline needs to be proposed when remodeling old buildings. In this research, various seismic performance evaluation methods which are being used in Japan and USA are reviewed in order to establish seismic performance evaluation index for those existing old structures in Korea.

  • PDF