• Title/Summary/Keyword: Segmental joint

Search Result 93, Processing Time 0.027 seconds

The Role of Speech Factors in Speech Intelligibility: A Review (언어장애인의 명료도에 영향을 미치는 말요인: 문헌연구)

  • Kim Soo-Jin
    • MALSORI
    • /
    • no.43
    • /
    • pp.25-44
    • /
    • 2002
  • The intelligibility of a spoken message is influenced by a number of factors. Intelligibility is a joint product of a speaker and a listener. In addition, intelligibility varies with the nature of the language context and the context of communication. Thus a single intelligibility score can not be ascribed to a given individual apart from listener and listening situation. But there is a clinical and research need to develop assessment measures of intelligibility that are quantitative and analytic. Before developing the index of intelligibility, the crucial factors need to be examined. Among them, the most significant in intelligibility is the speech factors of speakers. The following section reviews the literature dealing with the contribution of segmental and suprasegmental factors in speech intelligibility regarding the hearing impaired, alaryngeal, and motor disorders.

  • PDF

Mechanical Failure of Kotz Prosthetic Replacement for Osteosarcoma - A Case Report - (골육종에 시행한 Kotz prosthesis의 역학적 실패 - 증례 보고 -)

  • Cho, Duck-Yun;Kim, Hee-Chun;Shim, Myoun-Bo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.101-105
    • /
    • 1996
  • Prosthetic reconstruction of musculoskeletal defects about the knee for tumor has many advantages, particularly the maintenance of motion and immediate functional restoration. But, prosthetic reconstruction has inherent limitations in terms of long-term durability. The authors have reported here a patient who had mechanical failure at 61 months later following use of a modular resection system to reconstruct the segmental defect of proximal tibia in osteosarcoma. In this case, another technique of extensor mechanism reconstruction using Achilles tendon allograft was attempted. Because of the concerns involving durability of tumor prosthesis, increased emphasis has to be placed on innovation in prosthetic design.

  • PDF

Review of Somato Sensory Evoke Potential Test (체성감각유발전위검사에 대한 고찰)

  • Kim Myung-Chul;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.64-74
    • /
    • 2002
  • The SSEP(SomatoSensory Evoke Potentials) test is a valid and repeatable technique which correlates with clinically assessed joint position & vibration sense, skin touch & pressure sense. Also SSEP study is a simple and quantitative test, and has been used to evaluate the sensoty system along the somatosensory pathway from peripheral sensory receptor to the cortex. The ascending pathway of SSEP has been know to be posterior column-lemniscal pathway, but not without controversy. There are two kind of test mathods : one of test is median nerve SSEP and other test is posterior tibial nerve SSEP. Recently, SSEP used to performed to evaluate the usefulness of dermatomal SSEP(D-SSEP) and segmental SSEP(5-SSEP) for the diagnosis of lumbasacral radiculopathy, and it can be measure of ingual ahd palatine evoked potentials & indicator of medullary function useful for the diagnosis of brain death.

  • PDF

An Experimental Study on the Behavior of Precast Concrete Shear Keys (프리캐스트 콘크리트 전단키의 역학적 거동에 관한 실험연구)

  • 오병환;이준서;이형준;임동환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.04a
    • /
    • pp.86-89
    • /
    • 1992
  • In the precast segmental method of construction, segments of a structure are precast, assembled, and tied together by post-tensioning to form the structure. Shear strength and behavior of points in precast concrete structures are important problems in the design of these structures. An experimental program was set up study the shear behavior of precast concrete shear keys. experimental models of keyed joints include a single key, representing one of a series include the shear key shape, d/h ratio(1/4, 1/5, 1/7), and inclined angle (45。 60。 75。). Two different types of joints, i.e., epoxied joint and dry joints were studied. From the present tests, it is found that epoxied joints have higher shear strength than those of dry joints, and that high d/h ratio keys have higher shear strength than those of low d/h ratio keys. The keys with 60。-inclined angle shows the highest shear strength among various angles.

  • PDF

Performance assessment of precast concrete pier cap system

  • Kim, T.H.;Kim, Y.J.;Shin, H.M.
    • Computers and Concrete
    • /
    • v.13 no.4
    • /
    • pp.501-516
    • /
    • 2014
  • The purpose of this study was to investigate the performance of precast concrete pier cap system. The proposed precast pier cap provides an alternative to current cast-in-place systems, particularly for projects in which a reduced construction time is desired. Five large-scale pier cap specimens were constructed and tested under quasistatic monotonic loading. The computer program, RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology) was used for the analysis of reinforced concrete structures. A bonded tendon element is used based on the finite element method, and can represent the interaction between the tendon and concrete of a prestressed concrete member. A joint element is used in order to predict the inelastic behaviors of segmental joints with a shear key. This study documents the testing of the precast concrete pier cap system under monotonic loading and presents conclusions and design recommendations based on the experimental and analytical findings. Additional full-scale experimental research is needed to refine and confirm design details, especially for actual detailing employed in the field.

Development of Multibody Dynamic Model of Cervical Spine for Virtual In Vitro Cadaveric Experiment (가상 생체외 사체 실험용 경추 다물체 동역학 모델 개발)

  • Lim, Dae Seop;Lee, Ki Seok;Kim, Yoon Hyuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.953-959
    • /
    • 2013
  • In this study, a multibody dynamic model of the cervical spine was developed for a virtual in-vitro cadaveric experiment. The dynamic cervical spine model was reconstructed based on Korean CT images and the material properties of joints and soft tissue obtained from in-vitro experimental literature. The model was validated by comparing the inter-segmental rotation, multi-segmental rotations, load-displacement behavior, ligament force, and facet contact force with the published in-vitro experimental data. The results from the model were similar to published experimental data. The developed dynamic model of the cervical spine can be useful for injury analysis to predict the loads and deformations of the individual soft-tissue elements as well as for virtual in-vitro cadaveric experiments.

Biomechanical Analysis of a Bowling Swing (볼링 투구동작의 운동역학적 연구)

  • Lee, Hae-Myeong;Lee, Sang-Cheol;Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.53-63
    • /
    • 2006
  • The general objective of this study was to investigate biomechanical characteristics of bowling swing using three-dimensional cinematography. This study focused specifically on movements of the upper body segments during a bowling swing. Eight elite female bowling players participated in this study. Subjects performed bowling swing and their performance was sampled at 60 frame/sec using two high-speed video cameras with a synchronizer. After digitizing images from two cameras, the two-dimensional coordinates were used to produce three-dimensional coordinates of the 12 body segments (20 joint reference makers). The obtained three-dimensional coordinates were fed to a custom-written kinematic and kinetic analyses program (LabView 6.1, National Instrument, Austin, TX, USA). The analyses determined the linear and angular kinematic variables of the body segments with which joint force and torque of the lower and upper trunks and the shoulder were estimated based on the Newton-Euler equations. It was found that during the bowling swing the peak linear velocities of the body segments were reached in sequence the trunk, the shoulder, the elbow, the wrist, and the bowl. This result indicates that linear momentum of the lower body and the trunk transmits to the arm segment during the bowling swing. The joint torques of the torso and the arm occurred almost simultaneously, indicating that bowling swing seem to be a push-like motion, rather than a proximal-distal sequence motion in which many of throwing motions are categorized. The ultimate objective of the bowling swing is to release a heavy-weight bowl with power and consistency. Therefore, the bowling swing observed in this study well agrees with that bowlers use the stepping to increase the linear velocity of the bowl, the simple pendulum system and the push-like segmental motion in the torso and the arm segment to enhance the power at the release of the bowl.

Segmented Ulnar Transposition to Defect of Ipsilateral Radius in the Forearm (전완골 분절의 전위 이식술)

  • Chung, Duke-Whan;Han, Soo-Hong;Lee, Jae-Hoon;Kwon, Boo-Kyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.2
    • /
    • pp.125-132
    • /
    • 2007
  • Introduction: Ulna is nearly equal to radius in function and bony architecture and strength in forearm. But in lower extremity, fibula is 1/5 of tibia in anatomic and functional point so we can find fibula transposition is commonly used in defect of tibia. We cannot find other article about segmental forearm bone transposition in man. The purpose of this study was to report our clinical and functional result of undergoing segmented transposition of ipsilateral ulna with its own vascular supply in defect of radius in 6 cases. Material and method: From June 1994 to October 2007, 7 segmented bone transpositional grafts in forearm were performed in Kyung Hee Medical Center. The distribution of age was from 20 years old to 73 years old. There was male in 6 cases and female in 1 case. The causes of operation were giant cell tumor in 1 case and traumatic origin in 6 cases; it was nonunion in 2 cases and fracture with severe comminution in 4 cases. Ipsilaterally segmented ulna keeping its own vascular supply was transported to defect of radius in severe traumatic patients and one patient whose tumor in radius had been excised. Transported ulna was fixed to proximal and distal radius remnants by plate and screw. In one case with giant cell tumor, transported ulna was connected to radius across wrist joint as wrist joint fusion. Joint preserving procedures were performed in 6 cases with crushing injury of radius. Results: We could obtain solid bony union in all cases and good functional results. The disadvantage was relative shortening of forearm, but we could overcome this problem. Conclusion: We think that ipsilateral segmented ulna transposition keeping its own vascular supply to radius can be perfomed with one of procedures in cases with wide defect in radius.

  • PDF

Analysis on Bond Characteristics of Reinforcements for UHPC Hybrid Cable-Stayed Bridge Deck Joints (초고성능 콘크리트 하이브리드 사장교 바닥판 접합부 철근의 부착 성능에 대한 해석)

  • Seonwoo, Yoon Ho;Park, Sung Kyun;Kwahk, Im Jong;Yoon, Young Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.207-214
    • /
    • 2011
  • Ultra High Performance Concrete (UHPC), which is characterized by its high strength and advanced ductile behavior that is much superior to those of convention concrete, is a useful material to make thinner and longer bridges. The precast segmental construction method utilizing UHPC has been mainly studied because cast-in-place UHPC is very difficult and complicate to be achieved. As a part of those research, the structural performance evaluation of different types of joint connection method for hybrid cable-stayed bridge utilizing UHPC by using nonlinear analyses is performed in this study. The bond stress at joint is obtained by section force analyses for a 600 m cable-stayed bridge deck, and compared with the required bond stress at joint. Analysis results show that the U Type connection and straight type connection resist the highest ultimate load and bond strength, respectively. In addition, all considered joint connection systems satisfy the bond performances at joint required in the final stage of cable-stayed bridge utilizing UHPC.

The effects of Upper Thoracic Joint Mobilization Technique using Kaltenborn-Evjenth concept on Cervicothoracic ROM and Pain in patients with Chronic Neck Pain (Kaltenborn-Evjenth concept을 이용한 상부흉추 관절가동술이 만성 경부통증 환자의 경흉추 관절 가동범위의 변화와 통증에 미치는 영향)

  • Jun, Young Wook;So, Hyun Jeong;Jeong, Youn Do;Um, Sung Heum
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.479-486
    • /
    • 2015
  • This study was conducted to investigate the effects of upper thoracic joint mobilization technique using Kaltenborn-Evjenth concept on the range of cervical and thoracic motion and pain in patients with chronic neck pain. The subjects were divided into a thoracic joint mobilization group(n=7) and a conservative physical therapy group(n=7). Each of the groups received thoracic joint mobilization or conservative physical therapy three times a week lasted for four weeks. The measurements were performed for the range of thoracic segmental motion(SpinalMouse), the pain(visual analogue scale) and the range of cervical joint motion(Inclinometer, Dualer IQ). They were made four times: before experiment, at 2weeks, 4weeks, and 4weeks after experiment.