• Title/Summary/Keyword: Sectional measurement

Search Result 406, Processing Time 0.031 seconds

Measurement of Cross-sectional Temperature Distribution in Micro-scale Gap Fluid Using LIF Technique in Combination with CLSM (LIF 및 CLSM을 결합한 미소 간극 내 유체의 단면 온도 분포 측정 기법)

  • Jeong, Dong-Woon;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.834-841
    • /
    • 2006
  • In the present wort the Laser-induced Fluorescence (LIF) technique and Confocal Laser Scanning Microscopy (CLSM) have been combined to measure the temperature distribution across a micro-scale liquid layer as a direct and non-invasive method. Only the fluorescent light emitted from a very thin volume around a focal plane can be selectively detected, and it enables us to measure the liquid temperatures even at the close vicinity of the walls. As an experimental verification, a test section consists of two flat plates (for heating and cooling, respectively) separated by about 240 microns was made, and the methanol mixed with a temperature-sensitive dye, Rhodamine B, was filled in the gap between them. The measured temperature distribution across the gap showed good linearity, which is a typical characteristic of conduction heat transfer through a thin liquid layer. In result, the CLSM-LIF technique proposed in the present study was found to be a promising method to measure the local temperatures in the liquid flow field in microfluidic devices.

Characterization of the SnAg Electrodeposits according to the Current Density and Cross-sectional Microstructure Analysis in the Cu Pillar Solder Bump (전류밀도에 따른 SnAg 도금층의 특성 및 Cu 필라 솔더 범프의 단면 미세구조 측정)

  • Kim, Sang-Hyuk;Hong, Seong-Ki;Yim, Hyunho;Lee, Hyo-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.4
    • /
    • pp.131-135
    • /
    • 2015
  • We investigated the surface morphology and the change of Ag concentration for SnAg electrodeposits according to the current density using labmade and commercial plating solutions. The concentration of Ag in the SnAg electrodeposits decreased with increasing the current density. The Ag concentrations at the conditions of over $50mA/cm^2$ were below 3 wt% and the surface was relatively smooth. Cu pillar bump was fabricated by using SnAg electroplating, and it was reflowed at $240^{\circ}C$ for 90 sec. The cross-sectional microstructure was investigated by using EBSD measurement and it was found that the grain size of SnAg became smaller by increasing the number of reflow treatments.

Out-line Space-shape Variation of Clothing Fitness with Somatotype (체형유형에 따른 의복의 착의 공간 형상 변화)

  • 이수정
    • Korean Journal of Human Ecology
    • /
    • v.1 no.2
    • /
    • pp.113-118
    • /
    • 1998
  • Clothing shape is principally described in seven factors that are composed of clothing design, clothing material, clothing size, pattern design, sewing method and body motion etc.. The aims of this study was to measurement out-line space-shape variation of clothing fitness with somato type by using the image processing. The subjects for direct anthropometric measurements were 248 female college students aged from 19 to 22. The data were statistically analyzed by principal analysis and cluster analysis. The results were obtained three somato type. Also I made skirts in order to analyzed to the out-line space-shape variation of clothing fitness with body. The effect of somato type on the shape of flare skirts was determined by the out-line space-shape variation of clothing fitness with body. The out-line space-shape variation of clothing fitness with body was observed between the node number and amplitudes of clothing wave form and node number was determined at the maxim of space-shape amplitude, and the space-shape amplitudes have related with aspect ratio of cross-sectional shape. Results for flare skirts show changes in amplitude and mean with fabrics, somato type. therefore gray-level histogram are correlated with changes out-line space-shape, differences in drape spacing and related fabric properties and their somato type. (Korean J Human Ecology 1(2):113∼110 1998)

  • PDF

The phenomenology of pain in Parkinson's disease

  • Camacho-Conde, Jose Antonio;Campos-Arillo, Victor Manuel
    • The Korean Journal of Pain
    • /
    • v.33 no.1
    • /
    • pp.90-96
    • /
    • 2020
  • Background: Parkinson's disease (PD) is a neurodegenerative disorder that is the second most common disorder after Alzheimer's disease. PD includes both "motor" and "non-motor" symptoms, one of which is pain. The aim of this study was to investigate the clinical characteristics of pain in patients with PD. Methods: This cross-sectional study included 250 patients diagnosed with PD, 70% of which had mild to moderate PD (stages 2/3 of Hoehn and Yahr scale). The average age was 67.4 years, and the average duration since PD diagnosis was 7.1 years. Relevant data collected from PD patients were obtained from their personal medical history. Results: The prevalence of pain was found to be high (82%), with most patients (79.2%) relating their pain to PD. Disease duration was correlated with the frequency of intense pain (R: 0.393; P < 0.05). PD pain is most frequently perceived as an electrical current (64%), and two pain varieties were most prevalent (2.60 ± 0.63). Our findings confirm links between pain, its evolution over time, its multi-modal character, the wide variety of symptoms of PD, and the female sex. Conclusions: Our results demonstrated that the pain felt by PD patients is mainly felt as an electrical current, which contrasts with other studies where the pain is described as burning and itching. Our classification is innovative because it is based on anatomy, whereas those of other authors were based on syndromes.

Characteristics of Semiconductor-Atomic Superlattice for SOI Applications (SOI 응용을 위한 반도체-원자 초격자 구조의 특성)

  • Seo, Yong-Jin;Park, Sung-Woo;Lee, Kyoung-Jin;Kim, Gi-Uk;Park, Chang-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.180-183
    • /
    • 2003
  • The monolayer of oxygen atoms sandwitched between the adjacent nanocrystalline silicon layers was formed by ultra high vacuum-chemical vapor deposition (UHV-CVD). This multi-layer Si-O structure forms a new type of superlattice, semiconductor-atomic superattice (SAS). According to the experimental results, high-resolution cross-sectional transmission electron microscopy (HRTEM) shows epitaxial system. Also, the current-voltage (I-V) measurement results show the stable and good insulating behavior with high breakdown voltage. It is apparent that the system may form an epitaxially grown insulating layer as possible replacement of silicon-on-insulator (SOI), a scheme investigated as future generation of high efficient and high density CMOS on SOI.

  • PDF

Wind tunnel study of plume dispersion with varying source emission configurations

  • Wittwer, Adrian R.;Loredo-Souza, Acir M.;Schettini, Edith B. Camano;Castro, Hugo G.
    • Wind and Structures
    • /
    • v.27 no.6
    • /
    • pp.417-430
    • /
    • 2018
  • The concentration fields in the proximities of a local gas emission source are experimentally analyzed in several combinations of wind incidences and source emissions. These conditions are determined by the plume buoyancy, emission velocity and incident flow wind speed. Concentration measurements are performed by an aspirating probe in a boundary layer wind tunnel. The analysis included the mean concentration values and the intensity of concentration fluctuations in a neutral atmospheric boundary layer flow. Different configurations are tested: an isolated stack in a homogeneous terrain and a stack with a bluff body in close proximity, located windward and leeward from the emission source. The experimental mean concentration values are contrasted with Gaussian profiles and the dilution factor is analyzed with respect to the empirical curves of the minimum dilution. Finally, a study on the plume intermittency is performed in a cross-sectional plane near the emission source. It is possible to highlight the following observations: a) plume vertical asymmetry in the case of an isolated emission source, b) significant differences in the dispersion process related to the relative location of the emission source and bluff body effects, and c) different probabilistic behavior of the concentration fluctuation data in a cross-sectional measurement plane inside the plume.

A Study on the Scale and Dimensions of member of Sectional structure for Five-Purlin Houses from Joseon Era (조선시대 민가 오량가(五樑架) 종단구성의 규모와 부재치수에 관한 연구)

  • Kim, Jae-Ung
    • Journal of architectural history
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2019
  • As a part of the research on existing structures of private homes from Joseon Era. Focusing on one hundred twenty five-purlin houses, the current study investigated the features and characteristics of the house structure from style, size, proportion and roof pitch, and measurements of key parts, and developed the following conclusions. Most are single-houses (89, 83%), and among them, there are 47 single front-terrace houses (39%), which is the highest number. The sizes of lower house structure do not differ greatly depending on the vertical structure, and single rear terrace house and double-house have relatively larger side sizes. The size of upper structure is larger in double-houses compared to other vertical structures, indicating a relatively higher roof. The cross-section measurement of major parts show that double-houses are larger than single-houses by 3cm in pillar, 3-4.5cm in crossbeam length, and 4.5cm in crossbeam width. However, Janghyeo width was consistent at 7.5 to 10.5cm, maintaining uniformity regardless of vertical structure of the houses. In addition, the cross-section measurements decreased from sixteenth to nineteenth century, with the size of pillar size decreasing the most. The result that the Janghyeo width is not related to the house structure house confirmed that the Janghyeo width was kept consistent regardless of the size of the house structure.

Revisiting the measurement of keratinized gingiva: a cross-sectional study comparing an intraoral scanner with clinical parameters

  • Ahmet Mert Nalbantoglu;Deniz Yanik
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.362-375
    • /
    • 2023
  • Purpose: The aim of this study was to investigate the relationships between gingival thickness (GT) and keratinized gingiva width (KGW), papilla height (PH), and crown ratio (CR) by employing transgingival probing and an intraoral scanner (IOS). Methods: This cross-sectional study examined 360 maxillary anterior teeth from 60 patients. GT was assessed using transgingival probing with an endodontic spreader. KGW, CR, and PH were measured using an IOS. One-way analysis of variance, the Student's t-test, and Spearman correlation coefficients were employed for statistical analysis. Results: Higher GT was significantly associated with thinner KGW in the central region (P=0.019). There was no statistically significant difference in GT between teeth (P=0.06). PH was lower in lateral teeth than in canines (P=0.047), with a PH of 2.99 mm in lateral teeth. The KGW was narrower in canines than in central teeth (P=0.007). A moderate correlation was observed between KGW and PH in the central region (P=0.01), while a weak negative correlation was found between KGW and CR (P=0.043). Conclusions: A moderate negative correlation was found between GT and KGW, as well as between PH and KGW in central teeth. In contrast, a weak negative correlation existed between CR and KGW. The PH (2.99 mm) was lower in lateral teeth than in canines. The traditional paradigm, which suggests a positive correlation between KGW and GT, was reevaluated by measuring KGW using an IOS.

A scoping review of cephalometric normative data in children

  • Tuan Khang Nguyen;Akanksha Cambala;Manuela Hrit;Elizabeth A. Zimmermann
    • The korean journal of orthodontics
    • /
    • v.54 no.4
    • /
    • pp.210-228
    • /
    • 2024
  • Objective: Understanding the orofacial characteristics and growth patterns in children is essential for both orthodontics and research on children with orofacial abnormalities. However, a concise resource of normative data on the size and relative position of these structures in different populations is not available. Our objective was to aggregate normative data to assess the growth of the orofacial skeletal structures in children with a well-balanced face and normal occlusion. Methods: The MEDLINE, Embase, and Scopus databases were searched. Inclusion criteria included longitudinal and cross-sectional studies on cephalometric measurement of skeletal tissues and a study population ≤ 18 years with a well-balanced face and normal occlusion. Key study parameters were extracted, and knowledge was synthesized. A quality appraisal was performed using a 10-point scale. Results: The final selection comprised of 12 longitudinal and 33 cross-sectional studies, the quality of which ranged from good to excellent. Our results showed that from childhood to adulthood, the length of the cranial base increased significantly while the cranial base angle remained constant; both the maxilla and mandible moved forward and downward. The profile becomes straighter with age. Conclusions: Growth patterns in children with a well-balanced face and normal occlusion follow accepted theories of growth.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.