• Title/Summary/Keyword: Section loss

Search Result 563, Processing Time 0.028 seconds

STUDIES ON AVIAN INFECTIOUS DIARRHEA CLINICAL, HEMATOLOGIC, AND HISTOPATHOLOGICAL OBSERVATION (닭의 전염성하리에 관한 연구 - 임상, 혈액상 및 조직소견)

  • Lee Ki Poong;Lee Joon Sup
    • Journal of the korean veterinary medical association
    • /
    • v.7 no.6
    • /
    • pp.3-13
    • /
    • 1963
  • A large Proportion of an apparently healthy flock showed symptomes characterized by depression, loss of appetite, and watery diarrhea, and distention of the croup with sour-smelling contents, presenting severe cyanosis of comb. Laying flock revealed sever

  • PDF

A Review on Fluorescent Lamps Having Noncircular Cross-sections

  • Ko, Jae-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1165-1168
    • /
    • 2005
  • We review discharge characteristics of fluorescent lamps having noncircular cross sections. The developmental and theoretical history of noncircular cross-section lamps is summarized chronologically. In particular, discharge characteristics of noncircular cross-section lamps will be summarized and analyzed including plasma contraction, electron temperature, and ambipolar diffusion loss, which might give us some insights into the way to develop more efficient and uniform flat fluorescent lamps, which have recently arisen as a new light source of large-size backlight units for LCD TV applications.

  • PDF

Enthalpy Flow Loss by Steady Mass Streaming in Pulse Tube Refrigerators (맥동관냉동기의 정상상태 질량흐름에 의한 엔탈피손실)

  • 백상호;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.623-631
    • /
    • 2000
  • Effects of the taper angle and the angular velocity of a pulse tube on the enthalpy flow loss associated with the steady mass streaming were analysis by two-dimensional analysis of a pulse tube with variable cross-section. It was shown that the steady mass flux can lead to a large steady second-order temperature. The enthalpy flow loss associated with the steady mass streaming increases as the angular velocity increases. For a pulse tube where the viscous penetration depth is far thinner than the inner radius, the enthalpy flow loss can be significantly reduced by tapering the pulse tube since both the steady mass flux and the steady second-order temperature decrease as the taper angle increase.

  • PDF

An Experimental Study on The Frictional Loss of Stress in The Prestressing Tendons (PS 긴장재의 마찰손실량에 관한 실험적 연구)

  • 정배근;한경봉;박선규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.417-422
    • /
    • 2000
  • In prestressed concrete structures, determining serviceability and safety it is important to exactly calculate effective prestress force acting on structures. for the determination of effective prestress force, friction loss of the prestressing tendon should be decided exactly, but it is very difficult to measure the exact prestress force on the site and there is no actual field data. Therefore the friction loss coefficient recommended by the specification is not verified. in this paper, the friction loss standard PSC-Beam will be investigated, and is will be found what kind of relationship between the specification and the site. The results from this study can be summarized as follows. For jacking at both ends, actual intial prestress force in the center section of PCS-Beam was about 1.61% larger than theoretical initial prestress force and for hacking at one end, actual initial prestress force was approximate 4.9% lower than theoretical initial prestress force. Thus, for the exact calculation of friction loss, friction coefficient should be modified according to jacking methods.

  • PDF

A Study on the Temperature Characteristics Analysis in Tunnel using Loss Factor (손실율을 이용한 전력구내 온도특성 해석)

  • Lee, Sang-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.107-112
    • /
    • 2014
  • To cope with the ever increasing electric power demands in metropolitan areas, a greater underground cable transmission capacity is required. In general, it must be determined whether the temperature in the tunnel maintains the maximum allowable temperature. In order to improve this point, it is used to the loss factor. But, for economic cooling, it is problem to use such loss factor in this country. In this study, based on the load factor in this country, technique for calculating the loss factor has been presents. The suggested method has been tested in a sample section using the computer and the results have shown the usefullness of the suggested method.

Modification of the Existing Binders for Highly-Shattering, Short-Stem Rice Varieties (I) (탈립성(脱粒性), 단간종(短稈種)인 통일계품종(統一系品種)에 적합(適合)한 바인더의 개량(改良) 개발(開發)에 관(關)한 연구(硏究)(I))

  • Choi, Hee Seung;Chung, Chang Joo
    • Journal of Biosystems Engineering
    • /
    • v.7 no.1
    • /
    • pp.17-32
    • /
    • 1982
  • The binders introduced in Korea were originally designed to be used for Japonica-type varieties which have relatively long stem and are highly resistant to shattering. In order to use it for Tongil varieties which are short and easy to be shattered, mechanical modifications are necessary to reduce a grain loss incurred during binder operation. This study was intended to investigate analytically and experimentally the major sources of grain losses caused by three kinds of binders now introduced in Korea. Actual modification for each of three binders was done and experimentally compared to see if any improvement on grain loss was achieved. The results obtained in this study are summarized as follows; 1. It was required that the power transmission of binder should have a shifting mechanism so that velocities of pick-up and traveling units could be changed independently as desired according to the Japonica-type and Tongil varieties. In other words, the desired velocity of traveling unit should be obtained by shifting the transmission and the velocity of pick-up unit should be selected by reaping clutch according to the variety independent of the velocity of traveling unit as shown in Fig. 6. 2. To reduce grain loss it was desired that the moving parts of the pick-up unit should have the lowest possible velocities in harvesting Tongil varieties, unless the reduction of the speed be hindered the conveyance of the material. Based on the study, it was concluded that the velocities of pick-up unit be reduced by about 35% of those of the existing units. 3. It was found that the lug at the upper rotating section of pick-up case gave a severe impact on the ears of rice to increase grain loss. The optimum design of pick-up case to protect the ears from the protruding part of the lug was recommended by the result of analysis of the trajectory of the end-point of lug at the position. 4. It was proved analytically and experimentally that pick-up unit at the lower-rotating part was the other important source of grain loss in pick-up and divider assembly. In order to reduce a grain loss incurred by lugs at their lower-rotating section, it was suggested to improve it by (1) widening the space between right and left lower-rotating section, (2) shortening the length of lugs, (3) enlargement of the angle between the pick-up case and ground-level, and (4) attaching guard to right and left dividers so that the rotating lug could not give a high impact to the paddy hill. 5. Pick-up and divider assembly of the original binder of three models studied was modified according to the suggestions that were given by the preliminary study. Field test showed that the modified binders were able to reduce grain losses by about 0.4-0.7 percentage points compared to those without modification.

  • PDF

Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study

  • Kim, Sung-Beom;Kim, Young-Kyun;Kim, Su-Gwan;Oh, Ji-Su;Kim, Byung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.6
    • /
    • pp.247-252
    • /
    • 2014
  • Purpose: This study compares the prognosis (the survival rate and marginal bone loss) of resorbable blasting media (RBM) surface implants and sandblasting with large-grit and acid-etching (SLA) surface implants in the early loading. Methods: This study targeted 123 patients treated by implants installation from January 2008 to March 2010. The loading was initiated in the maxilla within three to four months and in the mandible within one to two months. The types of restoration were single crown and fixed partial prosthesis. Those functioned over one year. The implants were classified by the surface of implants as Group 1: RBM surface (GS III; OSSTEM, Busan, Korea) and, Group 2: SLA surface (Superline; Dentium, Seoul, Korea). The groups were categorized by maxilla and mandible and compared by survival rate, marginal bone loss through clinical records evaluation, and radiographic measurements. Results: The marginal bone loss in the maxilla was $0.14{\pm}0.34mm$ (Group 1) and $0.30{\pm}0.37mm$ (Group 2), a statistically significant difference (P<0.05). In the mandible those were $0.28{\pm}0.54mm$ (Group 1) and $0.20{\pm}0.33mm$ (Group 2), not significant (P>0.05). There was no significant difference of marginal bone loss between maxilla and mandible by groups. During observation there was no implant failure, a survival rate of 100%. Conclusion: Both surfaces showed an excellent survival rate, and the marginal bone loss was not substantial.

Analytical Modeling of Conventional and Miniaturization Three-Section Branch-Line Couplers

  • You, Kok Yeow;AL-AREQI, Nadera;Chong, Jaw Chung;Lee, Kim Yee;Cheng, Ee Meng;Lee, Yeng Seng
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.858-867
    • /
    • 2018
  • Analytical modeling equations are proposed for the conventional and modified three-section branch-line couplers. The analytical equations are explicit and capable of determining the characteristic impedance of each branch line for the coupler at desired coupling level as well as the suitability of broadband S-parameters analysis. In addition, a bandwidth extension and miniaturization of three-section branch-line coupler using slow-wave and meandering line structures were designed. The modified coupler, which is able to operate within frequencies from 1.5 to 3.32 GHz has been fabricated, tested and compared. A bandwidth extension of 600 MHz and 53% reduced size of the modified coupler have been achieved compared to a conventional coupler. The modified coupler has roughly insertion loss and coupling of -4 dB and -3.2 dB, while the isolation and return loss, respectively less than -14 dB with fractional bandwidth of 77 %, as well as phase imbalances less than $2^{\circ}$ over the operating bandwidth. Overall, the derived analytical model, simulation and measurement results demonstrated a good agreement.

A Study on the Power Loss Cost of Inner-Grid in the Offshore Wind Farm (해상풍력단지 내부그리드의 전력손실비용에 관한 연구)

  • Shin, Je-Seok;Kim, Sung-Yul;Bae, In-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.72-77
    • /
    • 2014
  • The cross-section area of cable in the Offshore Wind Farm (OWF) is smaller than that in the onshore wind farm. Because the power loss in OWF is large relatively, the power loss is a key element for the economic evaluation of OWF design. The availability of wind turbine in OWF and the size of OWF are larger than those of onshore wind farm. If the economic evaluation of OWF ignores the availability of wind turbines, the power loss cost of OWF is overpriced. Since there are so many wind turbines, also, the calculation of power loss should be more accurate. In this paper, a method to calculate power loss is proposed for the design of big and complex inner-grid in OWF. The 99.5MW OWF is used for case study to see what effect the proposed method have on the power loss cost.

Alveolar ridge preservation of an extraction socket using autogenous tooth bone graft material for implant site development: prospective case series

  • Kim, Young-Kyun;Yun, Pil-Young;Um, In-Woong;Lee, Hyo-Jung;Yi, Yang-Jin;Bae, Ji-Hyun;Lee, Junho
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.521-527
    • /
    • 2014
  • This case series evaluated the clinical efficacy of autogenous tooth bone graft material (AutoBT) in alveolar ridge preservation of an extraction socket. Thirteen patients who received extraction socket graft using AutoBT followed by delayed implant placements from Nov. 2008 to Aug. 2010 were evaluated. A total of fifteen implants were placed. The primary and secondary stability of the placed implants were an average of 58 ISQ and 77.9 ISQ, respectively. The average amount of crestal bone loss around the implant was 0.05 mm during an average of 22.5 months (from 12 to 34 months) of functional loading. Newly formed tissues were evident from the 3-month specimen. Within the limitations of this case, autogenous tooth bone graft material can be a favorable bone substitute for extraction socket graft due to its good bone remodeling and osteoconductivity.