• Title/Summary/Keyword: Secondary radiation

Search Result 320, Processing Time 0.024 seconds

The Radiopharmaceutical Therapy for Multiple Bone Metastases of Cancer (암의 다발성 뼈 전이의 방사성동위원소 치료)

  • Choi, Sang Gyu
    • Journal of Hospice and Palliative Care
    • /
    • v.17 no.4
    • /
    • pp.207-215
    • /
    • 2014
  • Multiple bone metastases are common manifestation of many malignant tumors such as lung cancer, breast cancer, prostate cancer and renal cell carcinoma. Bone metastasis is secondary cancer in the bone, and it can lead to bone pain, fracture, and instability of the weight bearing bones, all of which may profoundly reduce physical activity and life quality. Treatment for bone metastasis is determined by multiple factors including pathology, performance status, involved site, and neurologic status. Treatment strategies for bone metastasis are analgesics, surgery, chemotherapy and radiotherapy. External beam radiotherapy has traditionally been an effective palliative treatment for localized painful bone metastasis. However, in some cases such as multiple bone metastases, especially osteoblastic bone metastasis originated from breast or prostate cancer, the radiopharmaceutical therapy using $^{89}Sr$, $^{186}Re$, $^{188}Re$, $^{153}Sm$ and $^{117m}Sn$ are also useful treatment option because of administrative simplicity (injection), few side effects, low risk of radiation exposure and high response rate. This article offers a concise explanation of the radiopharmaceutical therapy for multiple bone metastases.

Analysis of Very High Resolution Solar Energy Based on Solar-Meteorological Resources Map with 1km Spatial Resolution (1km 해상도 태양-기상자원지도 기반의 초고해상도 태양 에너지 분석)

  • Jee, JoonBum;Zo, Ilsung;Lee, Chaeyon;Choi, Youngjean;Kim, Kyurang;Lee, KyuTae
    • New & Renewable Energy
    • /
    • v.9 no.2
    • /
    • pp.15-22
    • /
    • 2013
  • The solar energy are an infinite source of energy and a clean energy without secondary pollution. The global solar energy reaching the earth's surface can be calculated easily according to the change of latitude, altitude, and sloped surface depending on the amount of the actual state of the atmosphere and clouds. The high-resolution solar-meteorological resource map with 1km resolution was developed in 2011 based on GWNU (Gangneung-Wonju National University) solar radiation model with complex terrain. The very high resolution solar energy map can be calculated and analyzed in Seoul and Eunpyung with topological effect using by 1km solar-meteorological resources map, respectively. Seoul DEM (Digital Elevation Model) have 10m resolution from NGII (National Geographic Information Institute) and Eunpyeong new town DSM (Digital Surface Model) have 1m spatial resolution from lidar observations. The solar energy have small differences according to the local mountainous terrain and residential area. The maximum bias have up to 20% and 16% in Seoul and Eunpyung new town, respectively. Small differences are that limited area with resolutions. As a result, the solar energy can calculate precisely using solar radiation model with topological effect by digital elevation data and its results can be used as the basis data for the photovoltaic and solar thermal generation.

Intramedullary Spinal Cord Metastasis : A Report of Two Cases and a Review of the Literature (척수내 전이암 - 2례 보고 및 문헌고찰 -)

  • Oh, Yoon-Kyeong;Park, Hee-Chul
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.353-358
    • /
    • 2001
  • Intramedullary spinal cord metastases (ISCM) account for only $3.4\%$ of symptomatic metastases to the spinal cord. The survival of patients with ISCM is characteristically short, often no longer than 2 months, due to a rapid neurologic deterioration and the presence of widespread metastases, Including metastases to the brain. We report two cases of ISCM arising from primary sphenoid sinus carcinoma and primary lung cancer along with a review of the literature. The case of ISCM from the primary sphenoid sinus is the third case of secondary syringomyelia due to ISCM In the world literature, and ISCM from the primary lung cancer is the first case reported in Korea. One case showed a slow progression of symptoms and a longer survival (26 months after the radiotherapy to the spine), and the other showed a rapid deterioration of symptoms with a shorter survival. More effective palliation can be achieved if the disease is diagnosed at an early stage when the neurologic deficits are still reversible.

  • PDF

Estimated Risk of Radiation Induced Contra Lateral Breast Cancer Following Chest Wall Irradiation by Conformal Wedge Field and Forward Intensity Modulated Radiotherapy Technique for Post-Mastectomy Breast Cancer Patients

  • Athiyaman, Hemalatha;M, Athiyaman;Chougule, Arun;Kumar, HS
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5107-5111
    • /
    • 2016
  • Background: Epidemiological studies have indicated an increasing incidence of radiation induced secondary cancer (SC) in breast cancer patients after radiotherapy (RT), most commonly in the contra-lateral breast (CLB). The present study was conducted to estimate the SC risk in the CLB following 3D conformal radiotherapy techniques (3DCRT) including wedge field and forward intensity modulated radiotherapy (fIMRT) based on the organ equivalent dose (OED). Material and Methods: RT plans treating the chest wall with conformal wedge field and fIMRT plans were created for 30 breast cancer patients. The risks of radiation induced cancer were estimated for the CLB using dose-response models: a linear model, a linear-plateau model and a bell-shaped model with full dose response accounting for fractionated RT on the basis of OED. Results: The plans were found to be ranked quite differently according to the choice of model; calculations based on a linear dose response model fIMRT predict statistically significant lower risk compared to the enhanced dynamic wedge (EDW) technique (p-0.0089) and a non-significant difference between fIMRT and physical wedge (PW) techniques (p-0.054). The widely used plateau dose response model based estimation showed significantly lower SC risk associated with fIMRT technique compared to both wedge field techniques (fIMRT vs EDW p-0.013, fIMRT vs PW p-0.04). The full dose response model showed a non-significant difference between all three techniques in the view of second CLB cancer. Finally the bell shaped model predicted interestingly that PW is associated with significantly higher risk compared to both fIMRT and EDW techniques (fIMRT vs PW p-0.0003, EDW vs PW p-0.0032). Conclusion: In conclusion, the SC risk estimations of the CLB revealed that there is a clear relation between risk associated with wedge field and fIMRT technique depending on the choice of model selected for risk comparison.

Alarm Setpoint Determination Method of Gaseous Effluent Radiation Monitoring Systems Using Dose Factors Based on ICRP-60 Recommendations (선량환산인자를 이용한 기체유출물 RMS 경보설정 개선방안)

  • 박규준;김희근;하각현;엄희문
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.491-496
    • /
    • 2003
  • In Korea, the dose limits to the public were reduced according to ICRP-60 recommendations. The secondary quantities, Effluent Concentration Limits (ECLs) were derived and enacted to Korean Atomic Laws based on ICRP-60 recommendations. The Korea atomic laws require assurance that radioactive materials within gaseous effluents do not exceed dose limits and ECLs. This simply means that any effluent that would possibly contain radioactivity must be monitored. There are various methods to monitor the radioactivity of effluent monitor to satisfy the dose limits and the ECLs for gaseous effluents. The many factors (safety margin) should be considered in determining of the setpoint of effluent monitor, following these limits. In this study, we studied the determination method of alarm setpoint for gaseous effluent Radiation Monitoring Systems using dose factors considered the main pathway of radionuclides to compare the preceding determination method of alarm setpoint for gaseous effluent RMSs using dose assessment program considered all the practicable pathways of radionuclides.

  • PDF

Measurement of Neutron Production Double-differential Cross-sections on Carbon Bombarded with 430 MeV/Nucleon Carbon Ions

  • Itashiki, Yutaro;Imahayashi, Youichi;Shigyo, Nobuhiro;Uozumi, Yusuke;Satoh, Daiki;Kajimoto, Tsuyoshi;Sanami, Toshiya;Koba, Yusuke;Matsufuji, Naruhiro
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.344-349
    • /
    • 2016
  • Background: Carbon ion therapy has achieved satisfactory results. However, patients have a risk to get a secondary cancer. In order to estimate the risk, it is essential to understand particle transportation and nuclear reactions in the patient's body. The particle transport Monte Carlo simulation code is a useful tool to understand them. Since the code validation for heavy ion incident reactions is not enough, the experimental data of the elementary reaction processes are needed. Materials and Methods: We measured neutron production double-differential cross-sections (DDXs) on a carbon bombarded with 430 MeV/nucleon carbon beam at PH2 beam line of HIMAC facility in NIRS. Neutrons produced in the target were measured with NE213 liquid organic scintillators located at six angles of 15, 30, 45, 60, 75, and $90^{\circ}$. Results and Discussion: Neutron production double-differential cross-sections for carbon bombarded with 430 MeV/nucleon carbon ions were measured by the time-of-flight method with NE213 liquid organic scintillators at six angles of 15, 30, 45, 60, 75, and $90^{\circ}$. The cross sections were obtained from 1 MeV to several hundred MeV. The experimental data were compared with calculated results obtained by Monte Carlo simulation codes PHITS, Geant4, and FLUKA. Conclusion: PHITS was able to reproduce neutron production for elementary processes of carbon-carbon reaction precisely the best of three codes.

Evaluation of dose distribution from 12C ion in radiation therapy by FLUKA code

  • Soltani-Nabipour, Jamshid;Khorshidi, Abdollah;Shojai, Faezeh;Khorami, Khazar
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2410-2414
    • /
    • 2020
  • Heavy ions have a high potential for destroying deep tumors that carry the highest dose at the peak of Bragg. The peak caused by a single-energy carbon beam is too narrow, which requires special measures for improvement. Here, carbon-12 (12C) ion with different energies has been used as a source for calculating the dose distribution in the water phantom, soft tissue and bone by the code of Monte Carlobased FLUKA code. By increasing the energy of the initial beam, the amount of absorbed dose at Bragg peak in all three targets decreased, but the trend for this reduction was less severe in bone. While the maximum absorbed dose per bone-mass unit in energy of 200 MeV/u was about 30% less than the maximum absorbed dose per unit mass of water or soft tissue, it was merely 2.4% less than soft tissue in 400 MeV/u. The simulation result showed a good agreement with experimental data at GSI Darmstadt facility of biophysics group by 0.15 cm average accuracy in Bragg peak positioning. From 200 to 400 MeV/u incident energy, the Bragg peak location increased about 18 cm in soft tissue. Correspondingly, the bone and soft tissue revealed a reduction dose ratio by 2.9 and 1.9. Induced neutrons did not contribute more than 1.8% to the total energy deposited in the water phantom. Also during 12C ion bombardment, secondary fragments showed 76% and 24% of primary 200 and 400 MeV/u, respectively, were present at the Bragg-peak position. The combined treatment of carbon ions with neutron or electron beams may be more effective in local dose delivery and also treating malignant tumors.

Effect of High Protein Diet and Resveratrol Supplementation on the Nutritional Status and Immunoreactivity in the Irradiation-induced Inflammatory Rats (방사선 조사된 흰쥐에서 고단백식이와 레스베라트롤 첨가가 영양상태 및 면역기능 증진에 미치는 효과)

  • Kim, Kyoung-Ok;Chun, Mi-Son;Kang, Seung-Hee;Kim, Hyun-Sook
    • Journal of Nutrition and Health
    • /
    • v.42 no.7
    • /
    • pp.605-614
    • /
    • 2009
  • Most cancer patients are treated with surgery, chemotherapy or radiation as anticancer therapies. Especially in the case of radiation, these treatments produce adverse effects such as vomiting, weight loss, anorexia, normal cell damage and malabsorption. The major goal of this study was to determine the effect of irradiation on the nutritional and immune status in irradiated rats. A secondary goal was to determine the effectiveness of high protein diet (HP) and resveratrol (Res) in minimizing the adverse effects of radiation. Rats were divided into four groups: normal diet (NP), HP, NP + Res and HP + Res groups. Each group was further divided into subgroups that received radiation (RT group) and one that did not (non-RT group). Each diet was supplied from $12^{th}$ day prior to irradiation treatment with irradiation dose of 17.5 Gy. The diets were continued until 10th day after radiation treatment and animals were sacrificed. The radiation treatment showed decreased body weight, serum protein and HDL levels and increased TG and LDL levels in nutritional status. HP, NP + Res and HP + Res groups reduced the level of serum LDL and TG in irradiated rats. NP + Res and HP + Res groups increased reduced albumin level of serum in RT group. In case of immune status, the radiation treat-ment showed decreased WBC, lymphocytes and increased neutrophil and eosinophil levels. The levels of serum IL-2 and IL-6 were significantly increased by radiation, however the cytokine levels decreased in all dietary treatment groups. These results showed that high protein diet and resveratrol supplementation seem to minimize the adverse effects of radiation on lipid nutritional status and inflammation response in the rat model.

Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses (흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.120-125
    • /
    • 2010
  • For the measurements of an absorbed dose using the standard dosimetry based on an absorbed dose to water the variety of factors, whether big, small, or tiny, may influence the accuracy of dosimetry. The beam quality correction factor ${\kappa}_{Q,Q_0}$ of an ionization chamber might also be one of them. The cylindrical type of ionization chamber, the PTW30013 chamber, was chosen for this work and 9 chambers of the same type were collected from several institutes where the chamber types are used for the reference dosimetry. They were calibrated from the domestic Secondary Standard Dosimetry Laboratory with the same electrometer and cable. These calibrated chambers were used to measure absorbed doses to water in the reference condition for the photon beam of 6 MV and 10 MV and the electron beam of 12 MeV from Siemens ONCOR. The biggest difference among chambers amounts to 2.4% for the 6 MV photon beam, 0.8% for the 10 MV photon beam, and 2.4% for the 12 MeV electron beam. The big deviation in the photon of 6 MV demonstrates that if there had been no problems with the process of measurements application of the same ${\kappa}_{Q,Q_0}$ to the chambers used in this study might have influenced the deviation in the photon 6 MV and that how important an external audit is.

Evaluation of Characteristics in the Reference Gamma Radiation Fields for testing of Personnel Dosimetry Performance (개인선량 평가의 성능검증을 위한 기준급 감마선장의 특성 평가)

  • Oh, Jang-Jin;Cho, Dae-Hyung;Han, Seung-Jae;Na, Seong-Ho;Lee, Dew-Hey;Lee, Byung-Soo;Jun, Jae-Shik;Chai, Ha-Seok;Yi, Chul-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.229-236
    • /
    • 1998
  • In order to establish a testing system for personnel dosimetry performance, the radiation fields from photons, beta particles and neutrons are required, in recent, Korea Institute of Nuclear Safety(KINS) established the reference radation fields except neutrons and tested a variety of their properties. As a result of the test, the reference beams were shown to meet satisfactorily not only the standards of the International Organization for Standardization(ISO), but also the standard levels of the developed countries which are intercomparable with the international traceability. This paper describes the reference beam of gamma radiation. The self-designed and established reference radiation fields were investigated and analyzed by ISO and other international standards. The secondary photon contribution and the beam uniformity of the gamma radiation field were measured and evaluated to fulfill those requirements suggested by the ISO-4037. The measured air kerma rate for the $^{137}$Cs and $^{60}$Co gamma fields was 0.1891 $\sim$ 23.4967 $\mu$Gy/s sand 0.5844 $\sim$ 15.9954 $\mu$Gy/s respectively. The uncertainty with 95 % confidence level of the measured air kerma rate was determined to be less than 2.5 % which is comparable to the international reference gamma radiation fields. It was found that the evaluated air kerma calibration factors of Exradin ionization chamber were in good agreement within 0.9 % and 0.03 % with those given by PTB and NIST, respectively. The gamma radiation fields installed at KINS can maintain traceability systems in Korea, Germany and United State.

  • PDF