• Title/Summary/Keyword: Second Harmonic Signal

Search Result 88, Processing Time 0.021 seconds

Ultrasound Harmonic Imaging Method based on Harmonic Quadrature Demodulation (하모닉 직교 방식의 초음파 고조파 영상화 기법)

  • Kim, Sang-Min;Song, Jae-Hee;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.79-88
    • /
    • 2009
  • A harmonic quadrature demodulation method to extract the second harmonic component from focused ultrasound signals after a single transmit-receive event is proposed. In the proposed method, the focused ultrasound signal is converted into baseband inphase and quadrature components by multiplying with sine and cosine signals both having twice the center frequency of the transmitted signal and filtering the two modulated signals. The quadrature component is then passed through a Hilbert filter to be added to the inphase component, which leaves only the envelope of the second harmonic component. A novel phase estimation technique is employed in the proposed method to avoid the phase mismatch between the focused signal and the two modulating signals. The proposed method is verified through both theoretical analysis and computer simulations. It is shown that compared to the pulse inversion scheme the proposed method provides almost the same results for stationary targets and significantly improved harmonic to fundamental ratio for moving targets.

Precursor and Substituent Effects on the Alternate Adsorption of Polycation and Anionic Dyes as Studied by Second Harmonic Generation and Absorption Spectroscopies

  • Yamada, Sunao;Niidome, Yasuro;Hinoguchi, Takeshi
    • Journal of Photoscience
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2000
  • An alternately assembled polycation-anionic dye film was prepared on a precursor assembly of poly(allylamine)hydrochloride (PAH) and poly(sodium styrenesulfonate) (PSS) or of poly (djallyldimethyl)ammonium chloride (PDDA) and PSS. The (PAH/PSS) precursor assembly gave better adsorptivity to the anionic dye than the (PDDA/PSS) one. Four kinds of anionic dyes (EB-T, AR-17 AR-18, AR-27) with different numbers of sulfonate substituents were compared. The extent of dye assembling was higher for the dye with a smaller number of sufonate substituents. Second harmonic generation (SHG) was clearly observed from the films. The SHG signal and the absorption intensity correlated well up to four polycation/dye bilayers, while further assembly did not increase the SHG signal appreciably. Second order nonlinear coefficients for ten bilayer assemblies were the order of pm/V.

  • PDF

Nonlinear Time Reversal Focusing and Detection of Fatigue Crack

  • Jeong, Hyun-Jo;Barnard, Dan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.355-361
    • /
    • 2012
  • This paper presents an experimental study on the detection and location of nonlinear scattering source due to the presence of fatigue crack in a laboratory specimen. The proposed technique is based on a combination of nonlinear elastic wave spectroscopy(NEWS) and time reversal(TR) focusing approach. In order to focus on the nonlinear scattering position due to the fatigue crack, we employed only one transmitting transducer and one receiving transducer, taking advantage of long duration of reception signal that includes multiple linear scattering such as mode conversion and boundary reflections. NEWS technique was then used as a pre-treatment of TR for spatial focusing of reemitted second harmonic signal. The robustness of this approach was demonstrated on a cracked specimen and the nonlinear TR focusing behavior is observed on the crack interface from which the second harmonic signal was originated.

A Design of Predistortion Linearizer Using Second Harmonic Signals (2차 고조파 신호를 이용한 전치 왜곡 선형화기 설계)

  • Kim Sung-Yong;Kim Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.12 s.103
    • /
    • pp.1239-1245
    • /
    • 2005
  • In this paper, a new predistortion linearizer using second harmonic components feedforwarding is proposed. The harmonic generator of the proposed predistorter that consists of a small signal amplifier extracts second harmonic signals. A vector modulator that modulate fundamental signal with second harmonic signals, generates the inverse third order intermodulation distortion signals and controls amplitude/phase of them with modulation factors. As a result, this linearizer is suppressed IMD3 signals of power amplifier effectively. The test results show that the third order IMD of power amplifier is suppressed more than 20 dB for CW two-tone signals. Also, it's improved the adjacent channel power ratio(ACPR) more than 5 dB for CDMA(IS-95) 4FA signals.

The Second Harmonic Current Characteristic of PZT Thin Film Capacitor (PZT 박막 캐패시터의 2차 고조파 전류특성)

  • 김동철;박봉태;고중혁;문병무
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.8
    • /
    • pp.596-600
    • /
    • 1998
  • A method for the nondestructive read-out of the memory in ferroelectric thin films is demonstrated using the detection second harmonic currents introduced in the ferrolelectric capacitor as a response to an ac signal. The sign and phase of the second harmonic current depends on the polarized state +$P_r or -P_r$, The studied ferroelectric PZT thin film is found to have desirable features for the use as a memory element. This method and material seems as a promising approach for the nonvolatile memory storage.

  • PDF

Controller design for compensation of nonlinear harmonic distortion in direct-radiator loudspeakers (직접 방사형 스피커의 비선형 고조파 왜곡 보상 제어기의 설계)

  • 김윤선;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.399-402
    • /
    • 1996
  • The electrodynamic loudspeakers should have a wide dynamic range to reproduce various sound levels. When the input signal is small, the radiated sound from the loudspeaker is not so much distorted. However, for large input signal with low frequency component the radiated sound is significantly distorted due to the nonlinearities of the loudspeaker. The suspension, damping, and magnetic flux of loudspeaker are the main sources of the nonlinearity. Such electromechanical parameters related to harmonic distortion have been represented by a polynomial model for diaphragm displacement, while each of the polynomial coefficient is evaluated by using the principle of harmonic balance experimentally. Based on the polynomial model, we designed a compensator for nonlinear harmonic distortion of direct radiator loudspeaker. Than observer is used to estimate the displacement of the loudspeaker diaphragm, which is rather difficult to measure directly in the conventional setting. The usefulness of the designed compensator is demonstrated by numerical simulations. Simulation results show about 30db decrease at the second and third higher harmonic distortions. We carry out an experiment on speaker to verify designed controller and nonlinear observer.

  • PDF

Experimental Study of Second Harmonic Ultrasound imaging with a Weighted Chirp Signal (가중 쳐프 신호를 사용한 초음파 고조파 영상 기법의 실험적 고찰)

  • 김동열;이종철;송태경
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.151-154
    • /
    • 2001
  • In this Paper, a new harmonic imaging technique is proposed and evaluated experimentally. In the proposed method, a weighted chin signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic (2f0) component of a transmitted chirp signal generated in a square-law system. The proposed method uses the compressed 2f0 component to form an image, for which the crosscorrelation term with f0 component should be suppressed below at least -60dB. After experiment, the 6dB pulse width and peak sidelobe level of the compressed 2f0 component were 0.7us and -60dB, respectively. This result shows that the proposed method can successfully eliminate the f0 component with a single transmit-receive event and therefore is more efficient than the conventional pulse inversion (PI) method in terms of frame rate. We also observed that the 2nd harmonic compont starts to decrease for source pressure higher than 210kPa in water, which implies that SNR of the 2nd harmonic imaging using short pulses cnanot be incresed beyond a certain limit.

  • PDF

Design of Sub-Harmonics Pumped Ring Mixer (SHP 링혼합기 설계)

  • 김갑기;박용식;최충연;최병하
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.8
    • /
    • pp.1392-1398
    • /
    • 2000
  • In this paper, Sub Harmonic Ring Mixer using Anti-Parallel Diode Pair is studied. Conventional mixers mix LO signal with RF signal and, obtain IF signal from the difference between LO and RF. Sub harmonic ring mixers using APDP mix RF signal with the second harmonic of LO signal, LO frequency needed for conventional receiver is reduced by 1/2.The produced mixer showed 12 dB conversion loss, and 1 dB compression point of IF signal, in respect to RF signal, was found at the 0 dBm RF signal. Isolation LO/IF and LO/RF is 24.6 dB and 22.5 dB respectively. Isolation RF/LO and LO/RF is 32.6 dB and 22.5 dB respectively.

  • PDF

Closed-loop fiber optic gyroscope using gated two-harmonic phase modulation (두 주파수 위상변조 및 게이트를 이용한 폐회로 광섬유 자이로스코프)

  • 오문수;정만호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.528-532
    • /
    • 1987
  • Closed-loop fiber-optic gyroscope with linear scale factor for a wide dynamic range is demonstrated using a gating process and two-harmonic phase modulation, of which the second harmonic is obtained by a frequency doubler. Also the effects of the second harmonic and duty cycle of gating signal on the linearity of scale factor are estimated theoretically and compared with the measured data. The experimental results show the best linearity of scale factor is about 0.5% within the rotation rate 90.deg./sec. The closed-loop fiber-optic gyroscope with gated two-harmonic phase modulation can be used in the application demanding less sensitive performance and modest scale factor linearity.

  • PDF

1.9-GHz CMOS Power Amplifier using Adaptive Biasing Technique at AC Ground

  • Kang, Inseong;Yoo, Jinho;Park, Changkun
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.4
    • /
    • pp.285-289
    • /
    • 2019
  • A 1.9-GHz linear CMOS power amplifier is presented. An adaptive bias circuit (ABC) that utilizes an AC ground to detect the power level of the input signal is proposed to enhance the linearity and efficiency of the power amplifier. The ABC utilizes the second harmonic component as the input to mitigate the distortion of the fundamental signal. The input power level of the ABC was detected at the AC ground located at the VDD node of the power amplifier. The output of the ABC was fed into the inputs of the power stage. The input signal distortion was mitigated by detecting the input power level at the AC ground. The power amplifier was designed using a 180 nm RFCMOS process to evaluate the feasibility of the application of the proposed ABC in the power amplifier. The measured output power and power-added efficiency were improved by 1.7 dB and 2.9%, respectively.