• 제목/요약/키워드: Seawater Flowing

검색결과 28건 처리시간 0.022초

Estimating the Benefits of Seawater Flowing by using Meta-Regression for Benefit Transfer - Case of Geumgang River - (메타회귀분석을 이용한 해수유통 편익추정 - 금강을 중심으로 -)

  • Shin, Chang-Seob;Cho, Wonjoo
    • Journal of Korean Society of Rural Planning
    • /
    • 제29권4호
    • /
    • pp.191-200
    • /
    • 2023
  • This study aims to estimate the value of environmental services that could be generated by seawater flowing in the Geumgang Estuary by using meta-regression for benefit transfer. The environmental services that can be generated by seawater flowing are assumed to be improved water quality, increased biodiversity, and enhanced water-friendly effect. The analysis was conducted using 122 data from 28 studies from EVIS. The results show that households in the neighborhood where seawater is distributed are willing to pay about KRW 46,918, KRW 7,752, and KRW 7,859 per year for improved water quality, increased biodiversity, and enhanced water-friendly, respectively. The WTP of the national households other than neighboring households was found to be KRW 19,401, KRW 3,206, and KRW 3,250 for the three environmental services, respectively. The WTP for water quality improvement is higher than that for biodiversity increase and water-friendly effect increase, which may be due to the fact that water quality improvement is an environmental service that is close to the use value. In addition, neighboring households have a higher WTP than national households because neighboring households are more likely to evaluate the benefits of seawater flowing as a use value, while national households are more likely to evaluate it as a non-use value.

The Effect of Annealing Heat Treatment by Anodic Polarization Impedance Experiments for Cu-10%Ni Alloy

  • Lee, Sung-Yul;Moon, Kyung-Man;Jeong, Jae-Hyun;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권5호
    • /
    • pp.536-541
    • /
    • 2015
  • Copper has been used extensively as an electric wire or as a base material in various types of machineries owing to its good electrical and thermal conductivity and good fabricating property, as well as its good corrosion resistance compared to iron. Furthermore, the copper-nickel alloy has significant corrosion resistance in severely corrosive environments. Although, cupro-nickel alloy shows better corrosion resistance than the brass and bronze series, this alloy also corroded in severely corrosive environments, including aggressive chloride ions, dissolved oxygen, and condition of fast flowing seawater. In this study, and annealing treatment at various annealing temperatures was carried out on the cupro-nickel (Cu-10%Ni) alloy, and the effects of annealing were investigated using electrochemical methods, such as measuring the polarization and impedance behaviors under flowing seawater conditions. The corrosion resistance increased by annealing compared to non heat treatment in the absence of flowing seawater. In particular, the sample annealed at $200^{\circ}C$ exhibited the best corrosion resistance. The impedance in the presence of flowing seawater showed higher values than in the absence of flowing seawater. Furthermore, the highest impedances was observed in the sample annealed at $800^{\circ}C$, irrespective of the present of flowing seawater. Consequently, the corrosion resistance of cupro-nickel (Cu-10%Ni) alloy in a severely corrosive environment can be improved somewhat by annealing.

Study on the corrosion of A/C condenser in the ship (선박용 해수 열교환방식 A/C 응축기의 부식원인)

  • Baek, S.M.;Yang, J.H.;Kim, K.J.;Moon, K.M.;Lee, M.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.283-284
    • /
    • 2006
  • The ship performs heat exchange using seawater to keep main engine and auxiliary machinery at optimum temperature. In heat exchanger, refrigerant located outside of copper tube is cooled by seawater flowing through inside of copper tube. On the other hand, seawater erosion and corrosion nay occasionally cause the corrosion of the copper tube in A/C(Air Conditioner) condenser. This corrosion of copper tube makes seawater and refrigerant mixed, seriously damaging A/C system. In this study, accordingly, the exact ive mechanism of the corrosion on the condenser entailing serious problems occasional is investigated through the electrochemical polarization experiments on the condenser's component materials. According to the experiments, the corrosive procedures on the copper tube was verified by the fact that passive film of the copper tube surface which is destroyed by the pressure of sucked seawater, is damaged by the corrosive ingredients in the seawater.

  • PDF

3-Dimensional Numerical Analysis of Air Flow inside OWC Type WEC Equipped with Channel of Seawater Exchange and Wave Characteristics around Its Structure (in Case of Irregular Waves) (해수소통구를 구비한 진동수주형 파력발전구조물 내 공기흐름과 구조물 주변에서 파랑특성에 관한 3차원수치해석(불규칙파의 경우))

  • Lee, Kwang Ho;Lee, Jun Hyeong;Jeong, Ik Han;Kim, Do Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • 제30권6호
    • /
    • pp.253-262
    • /
    • 2018
  • Oscillating Water Column (OWC) Wave Energy Converters (WEC) harness electricity through a Power-Take-Off (PTO) system from the induced-airflow by seawater oscillating inside a chamber. In general, an air chamber with a relatively small cross-sectional area is required compared to seawater chamber to obtain high-velocity air in the PTO system, and in order to simulate an accurate air flow rate in the air chamber, a three-dimensional study is required. In this study, the dynamic response of OWC-WEC that is equipped with the channel of seawater exchange for the case of irregular waves has been numerically studied. The open source CFD software, OLAFLOW for the simulation of wave dynamics to the openFOAM and FOAM-extend communities, was used to simulate the interaction between the device and irregular waves. Based on the numerical simulation results, we discussed the fluctuation characteristics of three dimensional air flow in the air-chamber, wave deformation around the structure and the seawater flow inside the channel of seawater exchange. The numerical results the maximum air flow velocity in the air-chamber increases as the Ursell value of the significant wave increases, and the velocity of airflow flowing out from the inside of air chamber to the outside is greater than the speed of flowing into the air chamber from the outside.

Study on the Characteristics for Water Quality in Prearranged Saemangeum Reclaiming Area (새만금 예정수역의 수질특성 조사)

  • Lee, Kwang-Ya;Eom, Myung-Chul;Cho, Jae-Won;Jeong, Hae-Jin
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.555-558
    • /
    • 2003
  • This study carried out to analyze the characteristics of water concentration for Saemangeum reclaiming area during two seasons. Total nitrogen appeared by thing which all mean values are the biggest at two survey at ST.4 that is near with Mangyoung river. At the same time, change by range of tide was seen. Therefore, is thought that ST.4 suffers impact of river and seawater at the same time. But is thought that water of Mangyoung river exerts bigger effect than seawater because ST.4 appears that concentration is high clearly with different Sampling point. Therefore, is thought that pollution occurs better than different sampling point if ST.4's flowing deters.

  • PDF

Estimation on Corrosion of Reinforcing bar in Antiwashout Underwater Concrete (수중불분리성 콘크리트 중의 철근부식 평가)

  • 문한영;김성수;김홍삼;김종필
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.447-450
    • /
    • 2000
  • Recently, antiwashout underwater concrete has used for underwater structure such as high strength massive concrete structures. When, concrete is placed in seawater the quality and durability of concrete could be doubt to especcially because the amount of cement placed in the concrete can be diminished by flowing seawater. In this study, antiwashout underwater concrete mixed with mineral admixtures for improvement of properties was placed in air, water, and salt water. Half-cell potential and current density was of specimens which made under different conditions measured for estimating corrosion degree. The experimental results demostrate that corrosion resistantce in saltwater was little and mineral admixtures improved properties of concrete.

  • PDF

Evaluation of Cavitation Characteristics of 5083-O Al Alloy with Amplitude (5083-O 알루미늄 합금의 진폭에 따른 캐비테이션 침식 특성 평가)

  • Lee, Seung Jun;Kim, Seong Jong
    • Corrosion Science and Technology
    • /
    • 제11권5호
    • /
    • pp.205-212
    • /
    • 2012
  • With recent advances in engineering and technology, a damage on industrial machineries performing high-speed and high-power requirements has become a problem. There is an increasing possibility of cavitation damage, especially in pumps, propellers and high-speed vessels in a flowing liquid accordingly. There are several factors affecting cavitation damage on materials, including viscosity, pressure, temperature, amplitude applied. In this study, effects of cavity pressure in seawater on the damage for 5083-O aluminium alloy were evaluated by modulating amplitude. Trend of the damage with respect to time and amplitude was analyzed comparatively, and surface degradation of specimens was investigated by using Scanning Electron Microscope(SEM) and 3D microscope. The result reveals that the amount of the damage increased consistently with the increase in time and amplitude while the plastic deformation zone where no appreciable damage occurred was in less than 30 minutes.

Condenser cooling system & effluent disposal system for steam-electric power plants: Improved techniques

  • Sankar, D.;Balachandar, M.;Anbuvanan, T.;Rajagopal, S.;Thankarathi, T.;Deepa, N.
    • Membrane and Water Treatment
    • /
    • 제8권4호
    • /
    • pp.355-367
    • /
    • 2017
  • In India, the current operation of condenser cooling system & effluent disposal system in existing power plants aims to reduce drawal of seawater and to achieve Zero Liquid Discharge to meet the demands of statutory requirements, water scarcity and ecological system. Particularly in the Steam-Electric power plants, condenser cooling system adopts Once through cooling (OTC) system which requires more drawal of seawater and effluent disposal system adopts sea outfall system which discharges hot water into sea. This paper presents an overview of closed-loop technology for condenser cooling system and to achieve Zero Liquid Discharge plant in Steam-Electric power plants making it lesser drawal of seawater and complete elimination of hot water discharges into sea. The closed-loop technology for condenser cooling system reduces the drawal of seawater by 92% and Zero Liquid Discharge plant eliminates the hot water discharges into sea by 100%. Further, the proposed modification generates revenue out of selling potable water and ZLD free flowing solids at INR 81,97,20,000 per annum (considering INR 60/Cu.m, 330 days/year and 90% availability) and INR 23,760 per annum (considering INR 100/Ton, 330 days/year and 90% availability) respectively. This proposed modification costs INR 870,00,00,000 with payback period of less than 11 years. The conventional technology can be replaced with this proposed technique in the existing and upcoming power plants.

Corrosion Property Evaluation of Copper Alloy Tubes against Sea Water

  • Pang, Beilli;Ong, Sang-Kil;Lee, Hong-Ro
    • Journal of the Korean institute of surface engineering
    • /
    • 제42권6호
    • /
    • pp.280-286
    • /
    • 2009
  • In this study, the corrosion property of copper alloy tubes in seawater has been investigated. Three copper alloys of nominal composition Cu-20Zn-2Al(Al-Brass), Cu-30Ni(CN70/30) and Cu-10Ni(CN90/10) were considered. The samples were immersed in 3%NaCl flowing solution at $90^{\circ}C$ for 30, 50 and 80 days. Corrosion rate of copper alloy tubes in 3%NaCl flowing solution was investigated by weight-loss measurements and electrochemical test. The CN70/30 showed lowest corrosion rate among three copper alloy tubes. Because of passive films formation, corrosion rates of three types of copper tubes were decrease with time. Surface characteristics of copper alloy tubes were analyzed by optical micrograph(OM), scanning electronic microscopy (SEM), energy dispersive X-ray analysis(EDAX) and X-ray diffraction patterns(XRD). CN70/30 showed partly pitting problem on the surface owing to high Fe content, even though having high resistant against corrosion. Cracks appeared on the surface of CN90/10 and CN70/30 after more than 50 days immersion, which could be derived from high nickel contents.

Principle Relations Between Biomass and Production of Phytoplankton and Physicochemical Factors in Two Eutrophic Lakes of the Mediterranean Sea

  • Kim, Ki-Tai
    • Korean Journal of Environmental Biology
    • /
    • 제22권1호
    • /
    • pp.227-232
    • /
    • 2004
  • Hydrological and biological studies on ecosystems of the lakes 'etang de Berre' and 'etang de Vaime', the four rivers flowing into these lakes, and the Mediterranean Sea are carried out during the whole two-year period. The phytoplankton population of the lakes 'etang de Berre' and 'etang de Vaine' is larger than that of the seawater or freshwater populations of four neighbouring rivers. This is due to the increasing nutriments such as phosphate, nitrate, and silicate flowing into the lakes from the four rivers. The superfluous phytoplanktons in the lakes flow into the Mediterranean Sea via the Caronte Canal. Phytoplanktons multiplicated by phosphate of lake 'etang de Berre' can produce 10,160 tons of assimilated carbon per year, and those multiplicated by nitrate produce 18,450 tons of assimilated carbon per year. According to Steeman Nielsen's primary production estimation, phytoplanktons produce about 45,000 tons of carbon per year through assimilation in lake'4tang de Berre' and 10,000 tons of carbon per year in lake 'etang de Vaime'. The amount of carbon produced by phytoplanktons and the amount of phosphate, and nitrate are different according to the sea, river, and estuary.