• Title/Summary/Keyword: Seasonal performance factor

검색결과 34건 처리시간 0.018초

부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구 (An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions)

  • 최성경;이상헌;김선재;김용찬
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.

공급사슬에서 계절적 수요를 고려한 채찍효과 측도의 개발 (Quantifying the Bullwhip Effect in a Supply Chain Considering Seasonal Demand)

  • 조동원;이영해
    • 대한산업공학회지
    • /
    • 제35권3호
    • /
    • pp.203-212
    • /
    • 2009
  • The bullwhip effect refers to the phenomenon where demand variability is amplified when one moves upward a supply chain. In this paper, we exactly quantify the bullwhip effect for cases of seasonal demand processes in a two-echelon supply chain with a single retailer and a single supplier. In most of the previous research, some measures of performance for the bullwhip effect are developed for cases of non-seasonal demand processes. The retailer performs demand forecast with a multiplicative seasonal mixed model by using the minimum mean square error forecasting technique and employs a base stock policy. With the developed bullwhip effect measure, we investigate the impact of seasonal factor on the bullwhip effect. Then, we prove that seasonal factor plays an important role on the occurrence of the bullwhip effect.

인버터 압축기의 저속과 고속운전범위가 계절성능에 미치는 영향 (The effect on the seasonal performance of an inverter compressor with higher and lower operating range)

  • 박윤철;하도용;민만기
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.173-179
    • /
    • 1998
  • An experimental study was conducted on the effect of compressor capacity control range of heat pump on the seasonal energy efficiency ratio with variation of the maximum and minimum compressor input frequencies. To obtain seasonal energy efficiency ratio, steady state test at the maximum, minimum and intermediate compressor speed and cyclic test at the minimum compressor speed should be conducted. Maximum input frequency was varied to 95Hz, 105Hz, and 115Hz, and the minimum input frequency was varied to 35Hz, 45Hz, and 55Hz. The seasonal energy efficiency ratio increased as the input frequency of the compressor decreased. The maximum input frequency had only slight effects on the SEER.

  • PDF

스펙트럼 분석과 계절성 선형 모델을 이용한 Intra-Day 콜센터 통화량예측 (Spectral Analysis Accompanied with Seasonal Linear Model as Applied to Intra-Day Call Prediction)

  • 신택수;김명석
    • 응용통계연구
    • /
    • 제24권2호
    • /
    • pp.217-225
    • /
    • 2011
  • 본 논문에서는 스펙트럼 분석과 계절성 선형 모델을 이용하여 intra,-day 콜센터 통화량 예측에 필요한 계절성 변수를 찾아내는 방법을 제시한다. 제시한 방법을 북미 지역의 어느 은행의 5분 단위 콜센터 통화량에 실증 적용하여 기존의 통계적 방법으로는 입증할 수 없었던 월 단위 계절성 변수가 유의함을 보인다. 새로이 찾아진 연수가 intra-day 콜센터 통화량 예측능력을 향상시키는지 확인하기 위해서 새로운 변수를 포함하는 계절성 선형 모델과 이 변수를 포함하지 않은 계절성 선형 모델의 익일 통화량 예측능력을 비교 평가한다. 평가결과 새로운 변수를 포함한 모델이 우수하다는 결과를 얻었다.

주거용 건물에서의 히트펌프 시스템 연성능 평가에 관한 연구 (Analysis Study of Seasonal Performance Factor for Residential Building Integrated Heat Pump System)

  • 강은철;민경천;이광섭;이의준
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.3-10
    • /
    • 2016
  • 국내 히트펌프 유닛에 대한 성능 기준은 KS C 9306에서 제시하는 표준조건에서의 COP로 표현된다. 그러나 히트펌프 시스템이 실제 건물에 적용될 경우에는 표준조건에서 운전되는 것이 아니기 때문에 현장의 기후 조건, 건물의 특성에 따라 히트펌프 시스템의 성능은 다르게 나타난다. 본 논문에서는 주거건물을 대상으로 국내 주요 도시의 기후 조건에 따른 공기 대 공기 히트펌프 시스템의 연성능을 평가하여 기존의 BIN 데이터를 활용한 연성능 평가 결과와 정량적으로 비교 분석하였다. 연성능 평가도구로는 IPMVP 4.4.2에서 제시한 국제호환형 프로그램인 TRNSYS를 사용하였다. 공기 대 공기 히트펌프 유닛의 멀티 성능 데이터를 적용한 경우, 연성능 평가 기준인 APF는 BIN 데이터를 적용했을 때보다 전체적으로 높았으며, 부산이 2.36으로 가장 높았고, 대전이 2.29로 가장 낮았다.

수평형 지열 히트펌프 시스템의 냉난방 성능 분석 (Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger)

  • 손병후
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.230-239
    • /
    • 2012
  • Ground-coupled heat pump (GCHP) systems utilize the immense renewable storage capacity of the ground as a heat source or sink to provide space heating, cooling, and domestic hot water. The main objective of the present study is to investigate the cooling and heating performance of a small scale GCHP system with horizontal ground heat exchanger (HGHE). In order to evaluate the performance, a water-to-air ground-source heat pump unit connected to a test room with a net floor area of 18.4 m2 and a volume of 64.4 m3 in the Korea Institute of Construction Technology ($37^{\circ}39'N$, $126^{\circ}48'E$) was designed and constructed. This GCHP system mainly consisted of slinky-type HGHE with a total length of 400 m, indoor heat pump, and measuring devices. The peak cooling and heating loads of the test room were 5.07 kW and 4.12 kW, respectively. The experimental results were obtained from March 15, 2011 to August 31, 2011 and the performance coefficients of the system were determined from the measured data. The overall seasonal performance factor (SPF) for cooling was 3.31 while the system delivered heating at a daily average performance coefficients of 2.82.

인공신경망을 이용한 지하수위 예측과 계절효과 반영을 위한 입력치의 영향 (The Effect of Seasonal Input on Predicting Groundwater Level Using Artificial Neural Network)

  • 김인철;이준환
    • Ecology and Resilient Infrastructure
    • /
    • 제5권3호
    • /
    • pp.125-133
    • /
    • 2018
  • 인공신경망 (Artificial neural network, ANN)은 간편히 시계열 데이터를 예측할 수 있는 모델 중에 하나로 지하수위를 예측하는데 빈번히 사용되었으며, 많은 연구자들이 ANN으로 지하수위 예측에 있어서 높은 예측 신뢰성을 얻기 위하여 노력해 왔다. 본 연구에서는 ANN를 이용한 지하수위 예측 시 계절 효과를 반영하기 위한 input으로 사용되는 Dummy가 지하수위 예측 결과에 미치는 영향에 대하여 분석하였다. 정성적 및 정량적인 분석을 위하여 도해법과 상관계수, 에러 지수를 이용하였다. 분석결과 하천변 도심지역에서는 ANN의 input으로 사용된 Dummy가 오히려 예측 신뢰성을 떨어뜨리는 결과를 보였다.

히트펌프 성능 평가 동향과 국내 지열원 히트펌프 성능 평가 규격 및 제도 분석 (Analysis on the Performance Evaluation Trends of Heat Pumps and the Test Standards of a Geothermal Heat Pump in Korea)

  • 강신형;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.31-38
    • /
    • 2017
  • The heating and cooling air conditioning field has been increasing the problems of energy consumption and global warming in the world. A geothermal heat pump has been known as one of the highest efficient heating and cooling system. In this study, the analysis about the test standards of the geothermal heat pump of the Republic of Korea was executed. From the research, the following results were given. It is needed to address the domestic test standard for direct heat exchange geothermal heat pump. Water to air multi geothermal heat pump test standard was only developed in Korea. The test standard to calculate a seasonal energy efficiency ratio for cooling period and heat seasonal performance factor for heating period should be newly developed to estimate actual annual energy consumption and $CO_2$ emission.

에어컨의 냉방기간 에너지 효율 산출을 위한 실험적 연구 (Experimental Study on the Cooling seasonal Performance Factor of Room Air-conditioner)

  • 이홍원;문정호;배영돈;박종철
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.204-216
    • /
    • 1992
  • In most cases, EER(Energy Efficiency Ratio) is available to present energy efficiency of air-conditioners. But, EER is not adapt to measure energy efficiency at actual life environment because it is based on fixed temperature and humidity contditions. To overcome this disadvantage, there is need to introduce SEER(Seasonal Energy Efficiency Ratio) established at time varient temperature and humidity conditions. In this paper, SEER measurement method and conditions based on actual life environment of the country is introduced, and discussed SEER value about two air-conditioner type, that is, non inverter air-conditioner and inverter air-conditioner. As a result of, inverter air-conditioner was superior to non inverter air-conditioner at cooling seasonal energy efficiency.

  • PDF

가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구 (An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System)

  • 공형진;강성재;윤경식;임효재
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.