• 제목/요약/키워드: Seamless transfer

검색결과 86건 처리시간 0.021초

무중단 IoT 서비스 제공을 위한 IoT 로밍서비스 (IoT Roaming Service for Seamless IoT Service)

  • 안정욱;이병문
    • 한국멀티미디어학회논문지
    • /
    • 제23권10호
    • /
    • pp.1258-1269
    • /
    • 2020
  • The IoT(Internet of Things) service provides users with valuable services by collecting and analyzing data using Internet-connected IoT devices. Currently, IoT service platforms are accomplished by using edge computing to reduce the delay time required to collect data from IoT devices. However, if a user moves to another network with IoT device, the connection will be lost and IoT service will be suspended. To solve this problem, we proposes a service that automatically roaming IoT service when IoT device makes move. IoT roaming service provides a device automatic tracking management technique designed to continue receiving IoT services even if users move to other networks. To check if the proposed roaming service was effective, we implemented IoT roaming service and measured the data transfer time while move between networks along with devices while using IoT service. As a result, the average data transfer time was 124.62ms, and the average service interrupt time was 812.12ms. with this result, we can assume that the user could feel service interruption time very shortly and it will not affect the service experience. with IoT roaming service, we expect that it will present a method that stably providing IoT services even if user moves networks.

안전한 해사클라우드 환경을 위한 SH-Tree 기반의 데이터 동기화 기법 제안 (A Proposal of SH-Tree Based Data Synchronization Method for Secure Maritime Cloud)

  • 이동혁;박남제
    • 정보보호학회논문지
    • /
    • 제26권4호
    • /
    • pp.929-940
    • /
    • 2016
  • 국제해사기구(IMO)의 e-Navigation 전략에 따라, 선박 및 육지간 안전하고 정확한 정보 전달을 지원하는 통신 인프라가 필요한 상태이다. 해사클라우드는 이러한 필요성에 따른 해양 통신 인프라의 개념으로 사용되고 있으며, e-Navigation 도메인 지원에 필요한 여러 요소들을 지원하고 있다. 안전한 해양 환경을 위해서는 해사 클라우드에 대한 연구와 함께 보안의 고려가 반드시 필요하나, 아직까지 해사 클라우드 보안에 대한 연구는 초기 단계이다. 본 논문에서는 해사 클라우드 서비스의 원활한 제공에 필요한 데이터의 안전한 동기화 기법을 제안하였다. 제안한 방식은 본 논문에서 제안한 SH-Tree 기반으로 선박간 동기화가 가능하며, 동기화 과정에서 정보 노출이 없다는 장점이 있다.

비상전원 기능을 갖는 3kW급 하이브리드 ESS 개발 (Development of 3kW Hybrid ESS with Function of Emergency Power Supply)

  • 양석현;김민재;최세완;조준석
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.11-18
    • /
    • 2015
  • This paper proposes a high-efficiency 3-kW hybrid ESS with emergency power supply. The proposed system enables efficient use of power from photovoltaic (PV) cells and energy storage system (ESS). The proposed system can operate as an uninterruptible power supply (UPS) when grid fault occurs, providing seamless transfer from grid-connected mode to stand-alone mode. The LLC converter for PV achieves ZVS turn-on of switches and ZCS turn-off of diodes, and the isolated bidirectional DC-DC converter for ESS achieves ZCS turn-off regardless of load condition, resulting in high efficiency. The efficiency and performance of the proposed hybrid ESS has been verified by a 3-kW prototype.

계통연계형 배터리 에너지저장장치용 양방향 DC-DC 컨버터의 무순단 절체를 위한 조건부 적분 안티-와인드업 연구 (Improved Conditional Integrator Anti-Windup Method for Seamless Transfer of Bidirectional DC-DC Converter in Grid-Connected Battery Energy Storage System)

  • 엄준용;최성진;이홍희
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.333-342
    • /
    • 2020
  • Power exchanges between the grid and the battery through a bidirectional DC-DC converter are essential for DC microgrid systems. In general, the battery is charged when the grid is connected, and the system is powered by the battery when the grid is disconnected. In this mode transition, the saturation of the voltage controller slows down output response and produces large transient errors in DC link voltage. To solve this problem, a novel anti-windup design is proposed to improve anti-windup performance further. The proposed method stabilizes DC bus voltage through a wider range of battery voltage with faster transition compared with that of conventional methods. The proposed method is verified through an experimental setup composed of a 125 W laboratory-scale DC microgrid system.

Seamless and Secure Mobility Management with Location-Aware Service (LAS) Broker for Future Mobile Interworking Networks

  • Lee Minsoo;Kim Gwanyeon;Park Sehyun
    • Journal of Communications and Networks
    • /
    • 제7권2호
    • /
    • pp.207-221
    • /
    • 2005
  • The proliferation of wireless local area networks (WLANs) offering high data rate in hot spot area have spurred the demand for possible WLANs and third-generation (3G) cellular network integration solutions as the initiative step towards 4G systems. This paper provides a novel architecture for seamless location-aware integration of WLANs into 3G cellular networks and also an analysis for the efficient handover techniques. We introduce location as a key context in secure roaming mechanism for context-aware interworking in 4G systems. The fast secure roaming with location-aware authentication is implemented at an entity called location-aware service (LAS) broker that utilizes the concepts of direction of user and pre-warming zone. The location-ware interworking architecture supports seamless roaming services among heterogeneous wireless networks including WLANs, wireless metropolitan area networks (WMANs), and 3G cellular networks. This paper also includes a description of procedures needed to implement efficient mobility and location management. We show how the LAS broker with pre-warming and context transfer can obtain significant lower latency in the vertical handover.

Design of MPLS-based micro-mobility management protocol with QoS support

  • Kim, Byung-Chul;Lee, Jae-Yong
    • 한국통신학회논문지
    • /
    • 제28권1B호
    • /
    • pp.64-70
    • /
    • 2003
  • In order to provide seamless wireless Internet service, the basic mobile IP protocol should be enhanced to solve packet loss problem from large registration latency because frequent handoffs occur in cellular networks. In this paper, we suggest a new micro-mobility management protocol based on MPLS while supporting Qos, and evaluate its performance using simulation. We use MPLS label switching techniuqe in cellular access networks to simplify location management and speed up packet transmission. We adopt context transfer procedure to minimize the delay needed to attain prior level of service after handoff Packet loss can be minimized during handoff by transmitting received packets from old BSLER to new BSLER using a spliced LSP between them. Simulation results show that the proposed MPLS-based micro-mobility management protocol provides a seamless handoff and supports QoS of user traffic.

임계점 부근에서 이산화탄소의 증발열전달 및 압력강하 특성 연구와 상관식 개발 (Characteristics of Evaporative Heat Transfer and Pressure Drop of Carbon Dioxide and Correlation Development near the Critical Point)

  • 윤석호;조은석;김민수
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.530-537
    • /
    • 2004
  • In recent years, carbon dioxide among natural refrigerants has gained consider-able attention as an alternative refrigerant due to its excellent thermophysical properties. However, few investigations have been performed to develop useful correlations of heat trans-fer coefficients and pressure drop during evaporation of carbon dioxide. This study is aiming at providing the characteristics of heat transfer and pressure drop during the evaporation process of carbon dioxide. Heat is provided by a direct heating method to the test section, which was made of a seamless stainless steel tube with an inner diameter of 7.53 mm, and a length of 5.0 m. Experiments were conducted at saturation temperatures of -4 to 2$0^{\circ}C$, heat fluxes of 12 to 20 ㎾/$m^2$ and mass fluxes of 200 to 530 kg/$m^2$s. A comparison of different heat transfer correlations applicable to evaporation of carbon dioxide has been made. Based on the experiments for evaporation heat transfer and pressure drop, new correlations were developed. The newly developed empirical correlations for the heat transfer and pressure drop show average absolute deviations of 15.3% and 16.2%, respectively.

순수 및 혼합냉매의 원관내 증발열전달 실험 (Experimental study on convective boiling heat transfer for pure refrigerants and refrigerant mixtures in a horizontal tube)

  • 신지영;김민수
    • 대한기계학회논문집B
    • /
    • 제20권2호
    • /
    • pp.730-740
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants (R22, R32, R134a, R125, R290, and R600a) and refrigerant mixtures (R32/Rl34a, R290/ R600a, and R32/R125) are measured experimentally and compared with Chen's correlation. The test section is a seamless stainless steel tube with inner diameter of 7.7mm and uniformly heated by applying electric current directly to the tube. Heat fluxes range from 10 to 30kW$^2$. Mass fluxes are set to 424 ~ 742kg/m$^{2}$s for R22, R32, R134a, R32/R134a, and R32/Rl25 ; 265 ~ 583kg/m$^{2}$s for R290, R600a, and R290/R600a. Heat transfer coefficients depend strongly on heat flux at a low quality region and become independent as quality increases. Convective boiling term in the Chen's correlation predicts experimental data of the pure refrigerants fairly well (relative error of 12.1% for the data of quality over 0.2). The correlation for pure substances overpredicts the heat transfer coefficients for nonazeotropic refrigerant mixtures.

이산화탄소의 증발열전달 특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Evaporative Heat Transfer of Carbon Dioxide)

  • 조은석;윤석호;김민수
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.38-45
    • /
    • 2002
  • Evaporative heat transfer characteristics of carbon dioxide have been investi- gated by experiment. The experiments have been carried out for a seamless stainless steel tube of the outer diameter of 9.55 mm, the inner diameter of 7.75 mm and the length of 5.0 m. Direct heating method was used for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. Experiments were conducted with$CO_2$of purity 99.99% at saturation temperatures of 0.0 to 10.5$^{\circ}C$, heat fluxes of 12 to 27kW/$m^2$s and mass fluxes of 212 to 530 kg/$m^2$s. The heat transfer coefficients of $CO_2$are decreased as the vapor quality increases and these phenomena are explained by dimensionless Weber and Bond numbers. The heat transfer coefficients of$CO_2$increase when the heat and mass fluxes increase, and the saturation temperature effects are minor in the test range of this study. The present experimental data are compared with six renowned correlations with root-mean-squared deviations ranging from 23.0 to 94.9% respectively.

에너지저장시스템에서 매끄러운 모드절환을 위한 동작알고리즘 연구 (A Seamless Mode Transfer Scheme for ESSs)

  • 변병주;서현욱;조영훈;김동진;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.425-426
    • /
    • 2013
  • 본 논문에서는 에너지저장시스템에서 계통연계모드와 독립운전 모드사이를 절환하는 부분에 있어 매끄러운 모드 절환을 위한 동작알고리즘에 대하여 연구하였다. 이는 Psim 9.0을 사용한 시뮬레이션과 실험을 통하여 검증되었다.

  • PDF