• Title/Summary/Keyword: Sealing-Pad

Search Result 11, Processing Time 0.021 seconds

A Stress Analysis on the Split-sleeve of Quick Pipe Coupling (파이프 신속결합장치 틈-슬리브에 미치는 응력분포 연구)

  • Pyo, Jin-Soo;Kang, Jin-Woo;Choi, Kwang-Suk;Kim, Youn-Jea
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.502-505
    • /
    • 2008
  • Due to continuous difficulty of human power supply, it is necessary to develop an equipment which is good to saving cost and time at a construction site. A quick pipe coupling method is the kind of mechanical joint system using split-sleeve and sealing-pad at pipe groove without welding. In hence, it provides restrained pipe joint which is simple, safe, and dependable without environmental pollutions. It is more useful scheme than the other ones. The purpose of this study is to find out the main design factors and the optimum shape of split-sleeve. The stress analyses were carried out under various shapes of pipe groove configuration, materials and internal pressures with a commercial software, ANSYS workbench which uses FEM(finite element method). Results are graphically depicted with various parameters.

  • PDF

Fabrication of a high performance microvalve using a multilayer piezoelectric actuator and its characteristics (적층형 압전 엑츄에이터를 이용한 고성능 마이크로 밸브의 제작과 그 특성)

  • Seo, Jung-Ho;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.390-391
    • /
    • 2006
  • This paper describes the design, fabrication and characteristics of a micromachined piezoelectric valve utilizing a multilayer ceramic actuator (MCA). The micromachined MCA valve, which uses a buckling effect, consists of three separate structures: the MCA, the valve actuator die and the seat die. The valve seat die with 6 trenches was made, and the actuator die, which is driven by the MCA under optimized conditions, was also fabricated. After Si wafer direct bonding between the seat die and the actuator die, the MCA was also anodically bonded to the seat/actuator die structure. A polydimethylsiloxane (PDMS) sealing pad was fabricated to minimize the leak rate. Finally, the PDMS sealing pad was also bonded to the seat die and the stainless steel package. The MCA valve shows a flow rate of 9.13 sccm at an applied DC voltage of 100 V with a 50% duty cycle and a maximum non-linearity of 2.24% FS. Therefore, the fabricated MCA valve is suitable for a variety of flow control equipment, as a medical bio-system and in the automobile industry.

  • PDF

Control of Particle Contamination and Heat Build-Up for Noble Design of an Optical Disk Drive (광디스크 드라이브의 입자 오염 및 열축적 제어를 위한 설계 제안)

  • Oh, Seo-Young;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.1
    • /
    • pp.25-31
    • /
    • 2003
  • Airborne contaminant particles are intruded into optical disk drives(ODD) due to the flow caused by disk rotation and can be adhered to lens or disk surfaces, which causes decrease of laser power and increase of read/write errors. Such a phenomenon can be more serious as the space between the disk and the lens is reduced fur high-density storage devices. The purpose of this paper is to understand design parameters to reduce the particle intrusion into an ODD. Suggestions are made to prevent the particle intrusion that can decrease the stability of an ODD and also prevent the potential heat build-up problem. The sealing effect of drive and the forced injection of clean air (using HEPA filter) into the drive minimizes intrusion of the outside air and dusts in an ODD remarkably. Moreover it is proved by experiments that the installation of a heatproof pad to isolate heat generation part (PCB) from information read/write sections and the forced injection of dust-free air reduce the gas temperature inside the drive as well as the amount of particles intruded.

Wall-Suction Assisted Vacuum Sealing for Treatment of Infected Diabetic Foot Ulcer (벽매립형 중앙 흡인장치를 이용한 감염성 당뇨병성 족부 궤양의 밀봉 치료)

  • Bae, Su-Young;Lee, Chang-Wook;Seo, In-Seock
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.26-30
    • /
    • 2004
  • Purpose: The infected diabetic foot patients were reviewed to analyze the result of new dressing methods using a wall-suction instruments. Materials and Methods: Eighteen patients treated with wall-suction assisted vacuum dressing were included. After debridement under local anesthesia, a sponge pad, a drain, and a surgical drape were used to seal the wound. Negative pressure applied by the wall-suction at around 200 mmHg and dressing were repeated in every two to three days. The results of repeated wound cultures, growth of granulation tissues, and CRP level were closely observed on the regular basis. Results: Rapid growth of granulation tissues was noticed around the wound in 16 cases. No organism was obtained in an average 5 days and wound coverage was possible in an average 18 days. The CRP level returned to normal in an average 4 weeks. Two patients with end stage renal disease, who were regularly hemodialised, underwent major amputation. Conclusion: New dressing method has the following advantages: a rapid wound improvement in the patients with infected diabetic foot, less expensive, less painful, impediment of bacterial contamination in the hospital room. However, further study will be needed for the end stage renal disease patients.

  • PDF

Fabrication of a Micro Multilayer Piezo Actuator Valve and Its Characteristics (마이크로 적층형 압전밸브의 제작과 그 특성)

  • Chung, Gwiy-Sang;Kimm, Jae-Min;Cho, Sang-Bock
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.913-916
    • /
    • 2005
  • This paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramic actuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuator die and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement, respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimized conditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was also bonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 sccm at a supplied voltage of 100 V with a 50 % duty cycle, maximum non-linearity was 2.24 % FS and leak rate was $3.03{\times}10^{-8}pa$. $m^3/cm^2$.

  • PDF

A Experimental Study on Wear Characteristics of Cu Alloy for Piston Head and Bush Material of Hydraulic Servo Cylinder (유압 서보실린더의 동합금 피스톤 헤드와 부시의 마멸특성에 관한 실험적 연구)

  • Cho, Yon-Sang;Kim, Young-Hee;Byon, Sang-Min;Park, Heung-Sik
    • Tribology and Lubricants
    • /
    • v.25 no.5
    • /
    • pp.330-334
    • /
    • 2009
  • Hydraulic servo cylinders have been used to control accurately a large machine in power plant. Especially, Piston head and bush of servo cylinder is assembled sleeve and piston head and bush made of Cu alloy and pad sealing part. A damages of sleeve and piston head, bush are caused by friction and wear. Thus, It is necessary to examine friction and wear characteristics of Cu alloys for the piston head and bush. In this study, to be reliable on the piston and cylinder parts, dry friction and wear experiments were carried out with Cu alloys of four kinds of AlBC, PBC, BC and BS using reciprocating friction tester of pin on disk type. From this study, the result was shown that the AlBC and PBC with alloy elements were excellent to resistance wear. As the sliding speed was increased, the wear loss of PBC decreased than another Cu alloy.

Fabrication of MCA Valve For MEMS (MEMS용 적층형 압전밸브의 제작)

  • Kim, Jae-Min;Yun, Jae-Young;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.129-132
    • /
    • 2004
  • This paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramic actuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuator die and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement, respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimized conditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was also bonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 sccm at a supplied voltage of 100 V with a 50 % duty cycle, maximum non-linearity was 2.24 % FS and leak rate was $3.03{\times}10^{-8}\;pa{\cdot}m^3/cm^2$. Therefore, the fabricated MCA valve is suitable for a variety of flow control equipment, a medical bio-system, automobile and air transportation industry.

  • PDF

Fabrication and Characteristics of a Piezoelectric Valve for MEMS using a Multilayer Ceramic Actuator (적층형 세라믹 엑추에이터를 이용한 MEMS용 압전밸브의 제작 및 특성)

  • 정귀상;김재민;윤석진
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.515-520
    • /
    • 2004
  • We report on the development of a Piezoelectric valvc that is designed to have a high reliability for fluid control systems, such as mass flow control, transportation and chemical analysis. The valve was fabricated using a MCA(multilayer ceramic actuator), which has a low consumption power, high resolution and accurate control. The fabricated valve is composed of MCA, a valve actuator die and an seat die. The design of the actuator dic was done by FEM(finite element method) modeling, respectively. And, the valve seat die with 6 trenches was made. and the actuator die, which possible to optimize control to MCA, was fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the scat/actuator die structure. PDMS(poly dimethylsiloxane) sealing pad was fabricated to minimize a leak-rate. It was also bonded to scat die and stainless steel package. The flow rate was 9.13 sccm at a supplied voltage of 100 V with a 50 % duty ratio and non-linearity was 2.24 % FS. From these results, the fabricated MCA valve is suitable for a variety of flow control equipments, a medical bio-system, semiconductor fabrication process, automobile and air transportation industry with low cost, batch recess and mass production.

Design, Fabrication and Characteristics of a MCA Valve (적층형 압전밸브의 설계, 제작 및 특성)

  • Chung, Gwiy-Sang;Kim, Jae-Min;Yoon, Suk-Jin;Jeong, Soon-Jong;Song, Jae-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.230-235
    • /
    • 2004
  • This paper describes the design, fabrication and characteristics of a piezoelectric valve using MCA(Multilayer ceramic actuator). The MCA valve, which has the buckling effect, consists of three separate structures; MCA, a valve actuator die and an a seat die. The design of the actuator die was done by FEM modeling and displacement measurement, respectively. The valve seat die with 6 trenches was made, and the actuator die, which is driven to MCA under optimized conditions, was also fabricated. After Si-wafer direct bonding between the seat die and the actuator die, MCA was also anodic bonded to the seat/actuator die structure. PDMS sealing pad was fabricated to minimize a leak-rate. It was also bonded to seat die and SUS package. The MCA valve shows a flow rate of 9.13 seem at a supplied voltage of 100 V with a 50% duty cycle, maximum non-linearity was 2.24% FS and leak rate was $3.03{\times}10^{-8}pa{\codt}m^{3}/cm^{2}$. Therefore, the fabricated MCA valve is suitable for a variety of flow control equipment, a medical bio-system, automobile and air transportation industry.

The study of the packaging for Ti:LiN$bO_3$optical modulator device and its electrical and optical characteristics (Ti:LiN$bO_3$ 광변조기 소자의 패키징 및 전기.광학적 특성)

  • 윤형도;김성구;이한영;윤대원
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.72-78
    • /
    • 1998
  • An optical modulator Ti:LiNbO$_3$optical waveguide and CPW electrode structure were fabricated. The optical modulator was packaged using components such as ferrules, dirmy LN block and glass, vibration and shock absorbption pad, and alumina feeder through processings of pigtailing. Au wire bonding, epoxing, SMA connecting, sealing. The electrical and optical characteristics were measured after packaging. The electrical properties of S$_{21}$ and S$_{11}$ were obtained as 9.8 GHz at -3 dB and -8.9dB at 14.4GHz, respectively. Optical waveguide prepared met requirements for a single mode at a 1550nm wavelength range. Insertion loss was 4.3dB at room temperature after packaging, and was varied 4.3~6.4dB at various temperatures, 5~45$^{\circ}C$. E-O bandwidth measurement showed 3dB optical response at 7.8GHz, which means that it is applicable for 10Gbps optical communicationon

  • PDF