• 제목/요약/키워드: Sealing surface

검색결과 242건 처리시간 0.024초

근관충전방법에 따른 내흡수 치근의 근관충전 효율성 비교 (COMPARISON OF CANAL FILLING EFFICIENCY ON THE INTERNALLY RESORBED ROOT ACCORDING TO CANAL FILLING TEHNIQUES)

  • 하상윤;신동훈;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.789-801
    • /
    • 1995
  • Canals with artificially made internal resorption were filled with 4 techniques(Lateral condensation, Ultrafil, Obtura II, Thermafil) to compare the efficacy of canal filling according to the filling techniques. After canal filling, radiographic examination, dye penetration through the apical portion and percentage of G-P filled area on the internal resorption area were evaluated. To examine the degree of crystal-like structure and the interface between filled G-P and canal wall, SM and SEM images were taken too. The results were as follows : 1. There was no statistically significant difference in apical microleakage among the 4 root canal filling techniques. 2. As a result of radiographic examination, Ultrafil was the best and Obtura II was acceptable but Lateral condensation and Thermafil showed unfavorable canal filling pattern similarly. 3. Ultrafil filled most of artificially made internal resorption area and Obtura II, Lateral condensation, Thermafil in that order filled unfavorably. 4. Degree of crystal like structure was the highest in the group filled with Ultrafil and those of Obtura II and Thermafil were similar and that of gutta percha used in Lateral condensation showed the lowest value. 5. Penetration of gutta percha into the dentinal tubules couldn't be seen in all groups. In the contact surface between the filled G-P and the canal wall, Lateral condensation showed relatively close sealing, Obtura II and Thermafil had irregular contact surface and Ultrafil showed regular filling pattern. 6. Contact surface between the core of Thermafil and the gutta percha showed close relationship without gap formation.

  • PDF

전단접착강도와 탈락양상을 고려한 브라켓-접착제의 선택 (A Study on Bracket-Adhesive Combinations in Aspect of Shear Bond Strength and Bond Failure)

  • 한재익;손우성
    • 대한치과교정학회지
    • /
    • 제28권6호
    • /
    • pp.955-974
    • /
    • 1998
  • 적절한 전단접착강도를 가지면서 법랑질손상과 브라켓파절을 적게 일으키는 브라켓-접착제의 그룹을 찾아내기 위하여 전단접착강도, 법랑질손상, 브라켓탈락양상, 브라켓 주위의 밀봉과 법랑질-접착제-브라켓 사이의 긴밀도를 연구하였다. 교정치료 목적으로 발치한 240개의 치아를 각각 10개씩 24개의 군으로 나누어서 브라켓을 접착한 후 48시간 후에 전단접착강도를 측정하고 브라켓 탈락 양상을 조사하였다. 또한 브라켓 주위의 밀봉과 법랑질-접착제-브라켓 사이의 긴밀도를 평가하기 위하여 브라켓이 접착된 치아를 반으로 자른 후 주사전자현미경상에서 관찰하였다. 6종류의 브라켓과 4종류의 접착제가 사용되었으며 브라켓은 Image, Plastic, Crystaline, Fascination, Transcend, metal bracket을 사용하였으며 접착제로는 No-mix, Light-Bond, OrthoLC, Superbond C&B가 사용되었다. 이와같은 연구로부터 다음과 같은 결론을 내렸다. 1. 전단접착강도는 Fascination-Light Bond 군에서 36.58 Kg(410.07 Kg/$cm^2$)으로 가장 높았으며 Image-OrthoLC 군에 서 8.93 B◎ (75.51 Kg/$cm^2$)으로 가장 낮았다. OrthoLC를 접착제로 사용하였을 때 전단접착강도는 다른 접착제를 사용하였을 때 보다 비교적 낮았다. 2. 접착제의 종류에 관계없이 Fascination bracket의 전단접착강도는 비교적 높았으며 Image, Plastic bracket의 전단접착강도는 비교적 낮았다. Crystaline, Transcend bracket의 전단접착강도는 metal bracket의 전단접착강도와 비슷하거나 낮았다. 3. 전단접착강도와 법랑질 파절, 브라켓 파절은 상관관계가 있었으며, 접착강도가 증가할수록 법랑질 파절과 브라켓 파절은 증가하였다. 4. OrthoLC를 접착제로 사용하였을 때 법랑질 파절과 브라켓 파절은 일어나지 않았으나 Superbond C&B를 접착제로 사용하였을 때는 법랑질 파절과 브라켓 파절의 빈도가 높았다. 5. No-mix, Light-Bond를 접착제로 사용하였을 때 브라켓 주위의 밀봉과 법랑질-접착제-브라켓의 긴밀도는 양호하였다. 접착제의 종류에 관계없이 Ceramic bracket에서 접착제-브라켓의 긴밀도는 양호하였다. 6. 적절한 전단접착강도를 가지면서 법랑질 파절과 브라켓 파절을 일으키지 않는 군은 Crystaline-No mix, Crystaline Light Bond, Crystaline-OrthoLC, metal-No mix, metal-Light Bond, metal-OrthoLC군이였다.

  • PDF

Effects of Oxidation and Hot Corrosion on the Erosion of Silicon Nitride

  • Kim, Jong Jip
    • Corrosion Science and Technology
    • /
    • 제4권4호
    • /
    • pp.136-139
    • /
    • 2005
  • The effect of oxidation and hot corrosion on the solid particle erosion was investigated for hot-pressed silicon nitride using as-polished, pre-oxidized and pre-corroded specimens by molten sodium sulfates. Erosion tests were performed at 22, 500 and $900^{\circ}C$ using angular silicon carbide particles of mean diameter $100{\mu}m$. Experimental results show that solid particle erosion rate of silicon nitride increases with increasing temperature for as-polished or pre-oxidized specimens in consistent with the prediction of a theoretical model. Erosion rate of pre-oxidized specimens is lower than that of as-polished specimens at $22^{\circ}C$, but it is higher at $900^{\circ}C$. Lower erosion rate at $22^{\circ}C$ in the pre-oxidized specimens is attributed due to the blunting of surface flaws, and the higher erosion rate at $900^{\circ}C$ is due to brittle lateral cracking. Erosion rate of pre-corroded specimens decreases with increasing temperature. Less erosion at $900^{\circ}C$ than at $22^{\circ}C$ is associated with the liquid corrosion products sealing off pores at $900^{\circ}C$ and the absence of inter-granular crack propagation observed at $22^{\circ}C$.

중수로 냉각재 펌프용 미케니컬 페이스 실의 성능 해석 (Performance Analysis of Mechanical Face Seal Used for Primary Heat Transport Pump in Heavy Water Reactor)

  • 김정훈;김동욱;김경웅
    • Tribology and Lubricants
    • /
    • 제27권5호
    • /
    • pp.240-248
    • /
    • 2011
  • Mechanical face seal installed in primary heat transport pump used for heavy water reactor prevents leakage of working fluid using thin working fluid film between primary seal ring and mating ring. If the leakage of working fluid exceeds the allowable volume, serious accident can be happened by the trouble of primary heat transport pump. The thinner fluid film exists between primary seal ring and mating ring, the less working fluid leaks out. On the other hand, if the thickness of fluid film is not enough, the life of mechanical face seal will be reduced by friction and wear. Therefore appropriate design is necessary to maximize the performance and life of mechanical face seal. In this study, numerical analysis using finite volume method was conducted to investigate the performance of mechanical face seals which have same deep straight groove and 11 different net coning values. As results, equilibrium clearance between primary seal ring and mating ring, leakage volume of working fluid, friction torque on sealing surface and stiffness of working fluid film were obtained. With increasing net coning value, equilibrium clearance and leakage volume increase, and friction torque and stiffness of fluid film decrease.

소듐냉각 고속로의 커버가스 영역에서 열유동 해석 (ANALYSIS OF HEAT TRANSFER AND FLUID FLOW IN THE COVER GAS REGION OF SODIUM-COOLED FAST REACTOR)

  • 이태호;김성오;한도희
    • 한국전산유체공학회지
    • /
    • 제13권3호
    • /
    • pp.21-27
    • /
    • 2008
  • The reactor head of a sodium-cooled fast reactor KALIMER-600 should be cooled during the reactor operation in order to maintain the integrity of sealing material and to prevent a creep fatigue. Analyzing turbulent natural convection flow in the cover gas region of reactor vessel with the commercial CFD code CFX10.0, the cooling requirement for the reactor head and the performance of the insulation plate were assessed. The results showed that the high temperature region around reactor vessel was caused by the convective heat transfer of Helium gas flow ascending the gap between the insulation plate and the reactor vessel inner wall. The insulation plate was shown to sufficiently block the radiative heat transfer from pool surface to reactor head to a satisfactory degree. More than $32.5m^3$/sec of cooling air flow rate was predicted to maintain the required temperature of reactor head.

A Mobile Robot Based on Slip Compensating Algorithm for Cleaning of Stud Holes at Reactor Vessel in NPP

  • Kim, Dong Il;Moon, Young Jun
    • 한국압력기기공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.84-91
    • /
    • 2020
  • The APR1400 reactor stud holes can be stuck due to high temperatures, high pressure, prolonged engagement, and load changes according to pressure changes in the reactor. Threaded surfaces of a stud hole should be cleaned for the sealing of pressure in reactor vessel by removing any foreign materials which may exist in the stud holes. Human workers can access to the stud hole for the cleaning of stud holes manually, but the radiation exposure of human workers is increased. Robot is an effective way to work in hazardous area. So we introduced robot for the cleaning of stud holes. Localization of mobile robots is generally based on odometry, but with increased mileage, position errors can be accumulated. In order to eliminate cumulative error and to ensure stability of its driving, laser sensors and new control algorithm were utilized. The distance between the robot and the wall was measured by laser sensors, and the control algorithm was implemented so as to travel the desired trajectory by using the measured values from sensors. The performance of driving and hole sensing were verified through field application, and mobile robot was confirmed to be applicable to the APR 1400 NPP.

Mechanical Tenacity Analysis of Moisture Barrier Bags for Semiconductor Packages

  • Kim, Keun-Soo;Kim, Tae-Seong;Min Yoo;Yoo, Hee-Yeoul
    • 마이크로전자및패키징학회지
    • /
    • 제11권1호
    • /
    • pp.43-47
    • /
    • 2004
  • We have been using Moisture Barrier Bags for dry packing of semiconductor packages to prevent moisture from absorbing during shipping. Moisture barrier bag material is required to be waterproof, vapor proof and offer superior ESD (Electro-static discharge) and EMI shielding. Also, the bag should be formed easily to the shape of products for vacuum packing while providing excellent puncture resistance and offer very low gas & moisture permeation. There are some problems like pinholes and punctured bags after sealing and before the surface mount process. This failure may easily result in package pop corn crack during board mounting. The bags should be developed to meet the requirements of excellent electrical and physical properties by means of optimization of their raw material composition and their thickness. This study investigates the performance of moisture barrier bags by characterization of their mechanical endurance, tensile strength and through thermal analysis. By this study, we arrived at a robust material composition (polyester/Aluminate) for better packing.

  • PDF

전자전단 간섭법을 이용한 플랜지 용접부 내부 결함 측정에 관한 연구 (A Study on the Measurement of the Internal Crack in Flange Welding Zone by Digital Shearography)

  • 김정필;강영준;박상규
    • 한국정밀공학회지
    • /
    • 제26권1호
    • /
    • pp.97-104
    • /
    • 2009
  • There is a many kinds with nondestructive testing such as RT and UT representatively. Referred before two testing methods there is a limit which is spatial such as nuclear pipe, small vessel, sealing up vessel. So a new technique needs to overcome the limit which is spatial. shearography will be able to overcome the limit which is spatial. This paper introducing shearography which was known as non-contact full-field testing method and It is an interferometric technique for measurement of surface deformation such as displacement or displacement gradient. Also, a research about internal defect of the flange welding zone was accomplished. About variation with method pressurized with the Gaseous Nitrogen. Phase map where is various were measured according to changing a sheared direction, size of crack and loaded pressure. Consequently, crack quantitatively to be detected qualitatively was measured by using shearography.

울산시 구강보건교육 시범초등학교의 계속구강건강관리사업 (A study incremental dental care programs of appraisal report for oral health education elementary school in Ulsan City)

  • 김연화
    • 한국치위생학회지
    • /
    • 제7권1호
    • /
    • pp.31-39
    • /
    • 2007
  • This purpose of this study was to provide the basic data for preventing dental caries, and maintaining and enhancing Oral health education. The subject of this study through the survey of the recognition of Oral health education, a questionnaire survey and dental experience and Pit and fissure sealant status was conducted for 334 male and female students who were in the 4th, 5th, 6th grade of elementary school in Ulsan city. Statistical analysis was conducted using the SPSS 11.5 with t-test, ANOVA and correlation. The obtained results were as follows 1. Experience caries on permanent teeth was male score of 58.0% and female score of 42.0% and an everage score of 52.7% very low. 2. The students who were in the 4th, 5th, 6th grade of elementary school Experience caries on permanent teeth is grad higher(p=0.000). Pit and fissure sealant of teeth number and teeth surface status by grad higher(pE0.016, p=0.000). 3. Oral health knowledge and behavior is significantly related to status(p=0.001), behavior and Daily tooth brushing frequency was significantly related to status(p=0.000). But experience caries on permanent teeth and Oral health knowledge and behavior beween wasn't significantly related to status.

  • PDF

Vacuum Packaging and Operating Properties of Micro-Tunneling Sensors

  • Park, H.W.;Lee, D.J.;Son, Y. B.;Park, J.H.;Oh, M. H.;Ju, B. K.
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 Proceedings of 5th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.110-110
    • /
    • 2000
  • Cantilever-shaped lateral field emitters were fabricated and their electrical characteristics were tested. As shown in Fig.1, poly-silicon cantilevers were fabricated by the surface micromachining and they were used to the vacuum magnetic field sensors. The tunneling devices were vacuum sealed with the tubeless packaging method, as shown in Fig.2 and Fig.3. The soda-lime glasses were used for better encapsulation, so the sputtered silicon and the glass layers on the soda-lime glasses were bonded together at 1x10$^{-6}$ Torr. The getter was activated after the vacuum sealing fur the stable emissions. The devices were tested outside of the vacuum chamber. Through vacuum packaging, the tunneling sensors can be utilized. Fig.4 shows that the sensor operates with the switching of the magnetic field. When the magnetic field was applied to the device, the anode currents were varied by the Lorentz force. The difference of anode currents can be varied with the strength of the applied magnetic field.

  • PDF