Tip-less PDP Vacuum In-Line Sealing Technology by Bubble-Reduced Frit along an Auxiliary Heating Line

  • Kwon, Sang-Jik;Yang, Hwi-Chan;Lee, Myung-Sik;Whang, Ki-Woong;Jung, Dong-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.643-646
    • /
    • 2002
  • Sealing of two glass plates composing of PDP panel was done in a vacuum chamber by using an auxiliary heating line(AHL). In order to improve the uniformity of sealing temperature and reduce the panel temperature during sealing, the AHL was introduced by a screen printing method inside a frit glass and used as a part of heating source for the frit melting. By using the AHL technology and the specially prepared frit glass, we have successfully sealed a PDP test panel without bubbles and any leak through the frit glass.

  • PDF

The Development of the Manipulator and End-effector of Automated Pavement Crack Sealing Machine and Movement Test (도로면 크랙실링 자동화 장비의 모체 제작 및 구동 실험)

  • Lee, Jeong-Ho;Lee, Won-Jae;Yoo, Hyun-Seok;Kim, Young-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4D
    • /
    • pp.377-386
    • /
    • 2012
  • Crack sealing has been widely used in the pavement maintenance due to its advantage of repairing the cracks at the preliminary stages. However, it has been analyzed that the crack sealing work process is dangerous and labor intensive. Moreover, quality and productivity of crack sealing work are highly depended on labor experience and skills. Therefore, various crack sealing machines have been researched but revealed many limitations in practical application. This research analyses conventional crack sealing work process and previously developed crack sealing machines in order to develop an automated pavement crack sealing machine which can be practically and widely applied in the construction fields. This paper develops the previously proposed conceptual design by drawing detailed designs and fabricating the hardware(manipulator and end-effector) of the automated pavement crack sealing machine. The crack sealing machine suggested in this paper overcomes limitations of existing crack sealing machines and designed to meet the domestic road conditions and regulations. It is expected that automating the conventional crack sealing method contributes to the improvement of quality, economy and reduce accidents.

Vacuum In-line Sealing Technology of the Screen-printed CNT-FEA

  • Kwon, Sang-Jik;Kim, Tae-Ho;Shon, Byeong-Kyoo;Cho, Euo-Sik;Lee, Jong-Duk;Uh, Hyung-Soo;Cho, Sung-Hee;Lee, Chun-Gyoo
    • Journal of Information Display
    • /
    • v.4 no.3
    • /
    • pp.6-11
    • /
    • 2003
  • We have fabricated a carbon nanotube field emission display (CNT-FED) panel with a 2-inch diagonal size by using a screen printing method and vacuum in-line sealing technology. The sealing temperature of the panel was around 390$^{\circ}C$ and the vacuum level was obtained with 1.4x$10^{-5}$torr at the sealing. When the field emission properties of a fabricated and sealed CNT-FED panel were characterized and compared with those of the unsealed panel which was located in a test chamber of vacuum level similar with the sealed panel. As a result, the sealed panel showed similar I-V characteristics with unsealed one and uniform light emission with very high brightness at a current density of 243 ${\mu}A/cm^2$, obtained at the electric field of 10 V/${\mu}m$.

Development of bearing/sealing test facility for turbopump system (터보펌프 시스템용 베어링/실 시험설비 개발)

  • 우관제;김경호;우유철
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.25-28
    • /
    • 2003
  • The bearing/sealing test (BST) facility is intended for tests of bearing and seal for turbopump of liquid rocket engine (LRE) in various media (water, liquid nitrogen, liquid oxygen). The bearing test for serviceability is fulfilled with the estimation of the flow rate of cooling medium through the test bearing separator and with the simulation of axial and(or) radial loading. The purpose of seals test is the determination of magnitude of leakages through the seal and a time variation of this magnitude.

  • PDF

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.

A Study on Sealant Evaluation and Effectiveness of Saw and Seal Method for Reducing Reflection Cracking (반사균열 저감을 위한 Saw and Seal 공법의 줄눈재 평가 및 효과에 관한 연구)

  • Seo, Yong-Hwan;Suh, Young-Chan;Bae, Jong-Oh;Chon, Beom-Jun
    • International Journal of Highway Engineering
    • /
    • v.14 no.4
    • /
    • pp.73-81
    • /
    • 2012
  • PURPOSES : The purpose of this study is to select the proper sealing method and to see the performance of the saw and seal method for concrete rehabilitation based on accelerated pavement testings and lab tests. METHODS : Two accelerated pavement testings were conducted. One is to select proper sealing method of the asphalt joints and the other is to see the performance of the saw and seal method. Lab tests were conducted to select proper sealing method and a test section was constructed to see the field performance. RESULTS : The result of the first accelerated pavement testing indicated that the adhesive preformed sealants showed good performance when asphalt layer was rutted and in terms preventing from water infiltration. The second acceleration test indicated that the saw and seal method using the adhesive preformed sealant showed much better performance than the control. In the lab test bitumen, rubber and epoxy showed good performance as the adhesive. CONCLUSIONS : Saw and Seal method using the adhesive preformed sealant would markedly reduce the joint damage on the asphalt overlay.

Effects of anaerobic sealing agents on preload maintenance of screw-retained implant prosthesis with surface of screws (임플란트 보철물 나사의 전하중 유지에 나사 표면에 따른 혐기성 나사 고정제의 효과)

  • Ryu, Seung-Beom;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.2
    • /
    • pp.103-109
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the preload maintenance of the retaining screw when using anaerobic sealing agents in implant fixture and abutment components. Specifically, the study examines the effects of anaerobic sealing agents on different types of screws. Materials and methods: External hexagon implants made of titanium and anti-rotational abutments were used. Titanium abutment screws and ebony abutment screws from the same manufacturer were used. The experiment was divided into four groups (n = 10 in each group). In the control group, no sealing agent was used at the implant fixture and abutment screw interface. All abutment screws were tightened according to the manufacturer's recommended torque (30 N.cm). After 24 hours, the removal torque (detorque) of each screw was measured using a digital torque gauge device. The data were analyzed by two-way ANOVA test according to normality distribution satisfaction. Results: Looking at the results for each group, titanium screws and no treatment showed detorque values of 20.3 ± 1.6 N.cm. titanium screws and applied anaerobic sealing agent showed detorque values of 32.4 ± 6.7 N.cm. Ebony screws and no treatment showed detorque values of 20.2 ± 1.5 N.cm. ebony screws and applied anaerobic sealing agent showed detorque values of 30.4 ± 4.5 N.cm. Conclusion: The detorque value was higher in the case of using anaerobic sealing agents in both the titanium screw and ebony screw groups. But there was no difference between the two screws.

EFFECT OF SOFT CHELATING IRRIGATION ON THE SEALING ABILITY OF GP/AH PLUS ROOT FILLINGS (Soft chelating irrigation이 GP/AH Plus로 충전된 근관의 sealing ability에 미치는 영향에 대한 평가)

  • Yu, Yi-Suk;Kim, Tae-Gun;Lee, Kwang-Won;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.484-490
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of soft chelating irrigant on the sealing ability of root fillings by using a glucose leakage test. A total of 45 single-rooted teeth were selected for the study. The teeth were decoronated leaving a total length of 13mm. The root canals prepared using K3 NiTi rotary instruments to an apical dimension of size 45(0.06 taper). The specimens were then randomly divided into 3 experimental groups of 13 roots each and 2 control groups of 3 roots each. Specimen in each group were prepared with different irrigation protocols : group 1, 2.5% NaOCl; group 2, 2.5% NaOCl and 17% EDTA: group 3, 2.5% NaOCl and 15% HEBP. The root canals were filled with gutta-percha and AH Plus sealer using lateral condensation. After 7 days in $37^{\circ}C$, 100% humidity, the coronal-to-apical microleakage was evaluated quantitatively using a glucose leakage model. The leaked glucose concentration was measured with spectrophotometry at 1, 4, 7, 14, 21 and 28 days. There was a tendency of increase in leakage in all experimental groups during experimental period. HEBP-treated dentin showed no significant difference with EDTA-treated dentin during experimental period. From the 21th day onward, HEBP-treated dentin showed significantly lower leakage than smear-covered dentin. HEBP-treated dentin displayed a similar sealing pattern to EDTA-treated dentin and a better sealing ability than smear-covered dentin. Consequently, a soft chelator(HEBP) could be considered as the possible alternative to EDTA.

An experimental study for water tightness of segment under high water pressure (고수압 조건에서의 세그먼트 방수성능평가에 대한 실험적 연구)

  • Choo, Seok-Yean;Park, Young-Jin;Kim, Dong-Hyun;Kim, Yong-Il;Lee, Du-Wha;Cho, Sang-Kook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.4
    • /
    • pp.361-370
    • /
    • 2003
  • In this study, the performance of water tightness of water expansional sealing material and gasket was evaluated. The water tightness test was performed varying the type of inner pressure condition, for which the water expansional sealing material was inundated for 5 days to evaluate the ability of water tightness. In order to carry out this test, we made use of two types of water expansional sealing material; general type and combined type with non-expansional rubber. In the case of gasket, EPDM gasket and complex gasket sticked to the water expansional sealing material were applied. The performance of water tightness depended on the construction defect and the deformation of segment. The construction defect and segment deformation were generally expressed by gap and offset of the construction joint. The results, of tests showed that the performance of water tightness was largely influenced by the gap between segments. Management criteria of gap and offset were proposed.

  • PDF

Laser Sealing of Dye-Sensitized Solar Cell Panels Using V2O5 and TeO2 Contained Glass (V2O5 및 TeO2 함유 유리를 이용한 염료감응형 태양전지 패널의 레이저 봉착)

  • Cho, Sung Jin;Lee, Kyoung Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.3
    • /
    • pp.170-176
    • /
    • 2014
  • Effective glass frit compositions enabled to absorb laser energy, and to seal a commercial dye-sensitized solar-cell-panel substrate were developed by using $V_2O_5$-based glasses with various amounts of $TeO_2$ substitution. The latter was intended to increase the lifetime of the solar cells. Substitution of $V_2O_5$ by $TeO_2$ provided a strong network structure for the glasses via the formation of tetrahedral pyramids in the glass, and changed the various glass properties, such as glass transition temperature ($T_g$), dilatometric softening point ($T_d$), crystallization temperature, coefficient of thermal expansion (CTE), and glass flowage without any detrimental effect on the laser absorption property of the glasses. The thermal expansion mismatch (${\Delta}{\alpha}$) between the glass frit and the substrate could be controlled within less than ${\pm}5%$ by addition of 10 wt% of ${\beta}$-eucryptite. An 810 nm diode laser was used for the sealing test. The laser sealing test revealed that the VZBT20 glass frit with 10 wt% ${\beta}$-eucryptite was successfully sealed the substrates without interfacial cracks and pores. The optimum sealing conditions were provided by a beam size of 3 mm, laser power of 40 watt, scan speed of 300 mm/s, and 200 irradiation cycles.