• Title/Summary/Keyword: Sealing Test

Search Result 289, Processing Time 0.028 seconds

Permeability and strength characteristics of Self-Sealing and Self-Beating materials as landfill liners (매립지 차수재로서 자가치유재의 투수 및 강도특성)

  • 장연수;문준석
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.41-51
    • /
    • 2002
  • Recently, domestic waste landfills are constructed sometimes on seashore area to provide large landfill area. In order to strengthen the foundation of landfills and to prevent the infiltration of leachate through the bottom, many cases of constructing cement hardened liners on seashore clays are found. In these cases, it is possible to have cracks in the hardened liners due to settlement with waste load since the stiffness of the hardened liner Is greater than that of clay liners. In this study, the capability of Self-Sealing and Self-Healing (SSSH) liner made with a seashore clay in the metropolitan landfill to prevent the percolation of water and leachate is examined using flexible-wall permeameter test and using uniaxial compression test. Applicability of SSSH to weathered granitic soil is also examined for self-sealing capabilities. The result of Flexible permeameter test for SSSH with the seashore clay showed that permeability obtained was lower than permeability criteria of Korean waste management law. The permeability and strength characteristics of SSSH with granitic soil and bentonite showed better results than with the seashore clay.

Improvement of Sealing Property of Electrostatic Chuck by Applying Polysilazane Sealant (폴리실라잔계 실란트를 이용한 정전척 실링특성 향상 연구)

  • Choi, Jaeyoung;Park, Hyunsu;Son, Min Kyu;Jeong, Chang-oh;Kim, Woo-Byoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.6
    • /
    • pp.567-574
    • /
    • 2016
  • We have analyzed chemical properties of polysiloxane and polysilazane films, respectively, as sealing materials for electrostatic chuck (ESC) and have investigated the possibility of polysilazane as an alternative sealant to polysiloxane. It has been revealed that Si-O with organic bonding ($Si-CH_3$) existed in polysiloxane films compared to only pure Si-O bonding in polysilazane films. The sealing property of polysilazane has been found outstanding even in a short time of application. In the polysiloxane films containing $H_2O$, pin holes have been found possibly due to $CO_2$ gas evolution, and low adhesion with Si substrate has been observed after heat stress test in connection with the existence of organic bonding. After acid resistance test in 0.5 vol.% HF, 68 wt.% $HNO_3$, and 37 wt.% HCl solution, polyilazane films have shown a longer survival times. Compared to the conventional polysiloxane sealant, polysilazane is expected as a new sealing material because of good thermal and chemical stability.

Optimal Design for Tubular SOFC Testing Jig (관형 고체산화물연료전지 테스트 지그 최적화)

  • Choi, Hoon;An, Gwon-Seong;Shin, Chang-Woo;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.303-306
    • /
    • 2009
  • High temperature solid oxide fuel cells (SOFCs) offer a clean, pollution-free technology to electrochemically generate electricity at high efficiencies. Solid oxide fuel cells in several different designs have been investigated; these include planar and tubular geometries. The tubular type cell is widely researched due to it have advantages about thermal expansion and sealing issues. Unfortunately, lab scale tubular cell for testing has thermal expansion and sealing problems. The previous Jig for lab scale tubular cell testing has many sealing problems. When we feed fuel gas to jig inlet, ceramic glue sealant has amount of gas expansion pressure, because temperature of feeding gas changes ambient temperature to high temperature ($700{\sim}900^{\circ}C$). Furthermore, when we carry out long time test, something like degradation test, crack of ceramic glue sealant due to weakness of mechanical properties can make stop working the test. Additionally, we reduce setting process for assembling, because micanite is not required drying or debinding process.

  • PDF

Study on the Investization of Hot Sealing Difference of the Same Flexible Packaging (납품처가 다른 포장용 필름의 열접착 트러블 원인 규명에 관한 연구)

  • Park, Keun-Sil
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.8 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • We received 2 types flexible packaging films from two companies that laminated PET $16{\mu}m/dry$ lamination/aluminium foil $7{\mu}m/dry$ lamination/CPP $80{\mu}m$ films. For the reason of hot sealing's trouble through filling process, We separated each layer and compared thicks, film types and tested IR, DSC and sensory test. At the result, one sample's thick is different but film types is same between samples. Optimum hot-sealing conditions between two samples is $195^{\circ}C\;and\;210^{\circ}C$. The difference is $15^{\circ}C$. According to test of direct filling packaging process by four face fluid filling machine, two sample's sealing strength of hot-sealing is $4.76kg/cm2/15mm$(sample of optimum hot-sealing condition is $195^{\circ}C$) and $3.84kg/cm2/15mm(210^{\circ}C)$.

  • PDF

Shelf-life prediction of packaged cigarette subjected to different degrees of sealing (봉함도에 따른 포장담배의 저장수명 예측)

  • Keun-hoi Lee;young-hoh Kim;young-taek Lee;Kwang-soo Rhim;yong-tae Kim
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.12 no.2
    • /
    • pp.59-65
    • /
    • 1990
  • In order to predict the shelf-life of cigarettes packaged in typical flexible film under conditions of various temperature, relative humidity and sealing degree, a computer iterative technique was used. Although there were some significant differences at initial equilibrium relative humidity(55%), the experimental results agree fairly well with predictions following the student's t test($\alpha$=0.01) in most cases. Essentially, the higher the storage temperature, the shorter the shelf-life of the cigarette product. The bigger the differences from the initial equilibrium relative humidity, the shorter the storage period of the cigarette. Moisture transfer through the film at relatively high temperature gave higher confidence. The sealing degree, one of the storage parameters, appeared to be a major influencing factor to shelf-life. Slopes($\beta$) of the temp., sealing degree and %rh of the dependent variable to shelf life were 0.49, -0.39 and -0, 28 respectively, when analysed by multiple regression of SPSS software. Below 600m1/min sealing decree of the packed cigarette through the sealing Position at 30mmH20 differential pressure, the shelf-life could be increased by more than six months.

  • PDF

Strength Assessment of High-Pressure Ball Valve for Topside Process Unit (해양플랜트 탑사이드용 고압 볼밸브에 대한 구조 안전성 평가)

  • Oh, Jeong-Sik;Kim, Yooil;Jeong, Nakshin;Kim, Sangmyung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.100-108
    • /
    • 2016
  • A high-pressure ball valve was developed, and both the structural strength and sealing performance were assessed based on a nonlinear finite element analysis. Different parts were modeled with solid elements and assembled, taking into account both contact and sliding effects. Three different loading scenarios were analyzed, including a high-pressure closure test and fire and shell test conditions. The structural safety of each part was checked under each loading condition, and the sealing performance was also investigated to validate the performance of the valve.

The permeability charateristic of Z-type sheet pile joints under water sealing conditions (Z형 강널말뚝의 오염물질 차단효과)

  • Hong, Seung-Seo;Lee, Yong-Soo;Chung, Ha-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1283-1288
    • /
    • 2009
  • In general steel sheet piles are used in the containment system, which are vertical barrier systems for waste disposal and landfill purposes, and roads in excavation for temporary structure. This paper presents case study of the use of an interlocking sheet pile for water and containment. Cut-off Z-type sheet pile joints are investigated to determine their permeability from the field test. Four different joint sealing materials are used in field test. The results showed joint permeability is significant time-dependent and joint-dependent. These are explored and conclusions on permeability characteristics of different sealants are noted. A case study gives a design example as well as suggestion on permeability and water tightness can be implemented in using the sheet pile barrier in civil and environment works. From the test results, the effective sealing programs of sheet pile interlocks are suggested.

  • PDF

Direct Sealing Glass-Ceramics to Metal (직접 결합방법에 의한 Glass-Ceramics과 금속의 접합)

  • Kim, Hwan;Lee, Ki-Kang
    • Journal of the Korean Ceramic Society
    • /
    • v.18 no.2
    • /
    • pp.99-104
    • /
    • 1981
  • Glass-ceramics possessed a number of characteristics which suggested their suggested their use for sealing to metals. The choice of particular glass-ceramics compositions for this application is governed by various factors, including workability of the glasses, thermal expansion characteristics and the matching of these to appropriate metals. Other properties, such as mechanical strength, determined the performance of glass-ceramics to metal seals. The purpose of the present study was to investigate direct sealing behaviour of copper to $Li_2O-ZnO-SiO_2$ system glass-ceramics. The design of the seal was a concentric seal which might contribute to the strong bond formation by providing compressive stress during thermal excursions. Tensile strengths of sealing layers were measured by Instron test machine. The layers were examined by electron probe microanalyzer. Crsystallization rate was increased with the amount of ZnO or $Li_2O$, and ZnO increased the sealing strength, but $Li_2O$ lowered it. Sealing mechanism was due to the formation of metal oxides, which acted as binder between copper and glass-ceramics. The nickle-plated copper seal with 10% $Li_2O$ and 30% ZnO was the most strong seal, and its sealing strength was more than 56kg/$\textrm{cm}^2$.

  • PDF

A Study on the Usability of the Vascular Bursting Pressure Test as a Method of Performance Evaluation of Vessel Sealing (혈관결찰기의 성능평가방법으로서 혈관파열압력시험의 유용성 연구)

  • Kang, Bo Ram;Park, A Reum;Kim, Kwang Taek;Kim, Seon Tae;Lee, Dong Hyuk
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.210-218
    • /
    • 2020
  • Vessel sealing is a medical device that converts electrical or ultrasonic energy into thermal energy and leads to seal, coagulate, and cut the vessel by protein modification within the walls or surrounding connective tissues. As most of surgeries have recently been conducted with minimally invasive surgery, the demand and market for vessel sealing are expected to get bigger. However, there is a problem that electrosurgical or ultrasonic surgical is applied and we have a high risk to evaluate the strength of seal, because the collateral and particular standards currently in force follows have not been establish. Therefore, in this study, we investigated some papers studied on the efficacy and safety of the device, the guidance of FDA and test papers previously conducted from 3 individual subject device made in Korea. We found there is a relationship between burst pressure and the performance of the device, therefore, we propose the vascular bursting pressure test for evaluating the safety and performance of the vessel sealing.

Development of Sealing Technology for Far-Infrared Multispectral ZnS Using Chalcogenide Glass Material

  • Soyoung Kim;Jung-Hwan In;Karam Han;Yoon Hee Nam;Seon Hoon Kim;Ju Hyeon Choi
    • Korean Journal of Materials Research
    • /
    • v.32 no.12
    • /
    • pp.515-521
    • /
    • 2022
  • Various types of optical materials and devices used in special environments must satisfy durability and optical properties. In order to improve the durability of zinc sulfide multispectral (MS ZnS) substrates with transmission wavelengths from visible to infrared, Ge-Sb-Se-based chalcogenide glass was used as a sealing material to bond the MS ZnS substrates. Wetting tests of the Ge-Sb-Se-based chalcogenide glass were conducted to analyze flowability as a function of temperature, by considering the glass transition temperature (Tg) and softening temperature (Ts). In the wetting test, the viscous flow of the chalcogenide glass sample was analyzed according to the temperature. After placing the chalcogenide glass disk between MS ZnS substrates (20 × 30 mm), the sealing test was performed at a temperature of 485 ℃ for 60 min. Notably, it was found that the Ge-Sb-Se-based chalcogenide glass sealed the MS ZnS substrates well. After the MS ZnS substrates were sealed with chalcogenide glass, they showed a transmission of 55 % over 3~12 ㎛. The tensile strength of the sealed MS ZnS substrates with Ge-Sb-Se-based chalcogenide glass was analyzed by applying a maximum load of about 240 N, confirming its suitability as a sealing material in the far infrared range.