• Title/Summary/Keyword: Sea water reverse osmosis

Search Result 31, Processing Time 0.025 seconds

A study on boron removal for seawater desalination using the combination process of mineral cluster and RO membrane system

  • Cho, Bong-Yeon;Kim, Hye-Won;Shin, Yee-Sook
    • Environmental Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.285-289
    • /
    • 2015
  • Complicated and expensive seawater desalination technology is a big challenge in boron removal process. Conventional seawater desalination process of coagulation utilized for pre-treatment is difficult to remove boron. Boron can be removed more effectively in Reverse Osmosis (RO) process than any other processes. In this study, a coagulant with the name Mineral Cluster was examined its boron removal ability. Boron removal efficiency of Mineral Cluster depended on pH value and Mineral Cluster dosage. Desalination process combines the pre-treatment process with Mineral cluster diluted at the ratio of 1:2500 and the RO membrane process. The original sea water could be desalinated to drinking water quality, 1 mg/L, without any pH adjustments. Therefore, if the Mineral cluster is added without any other chemicals for adjusting pH, the desalination process would be much safer, efficient and economical.

Effect of Reverse Osmosis-treated Deep Sea Water Supplementation on the Quality Characteristics of Chicken Meat (역삼투 처리한 해양 심층수의 급여가 닭고기의 품질 특성에 미치는 영향)

  • Kang, Sun-Moon;Lee, Ik-Sun;Ohh, Sang-Jip;Kim, Gur-Yoo;Lee, Sung-Ki
    • Korean Journal of Poultry Science
    • /
    • v.37 no.4
    • /
    • pp.373-382
    • /
    • 2010
  • This study was carried out to investigate the effect of reverse osmosis (RO)-treated deep sea water (DSW) supplementation on the quality characteristics of chicken breast meat. For 28 days, one-day-old broiler chicks (Ross 308) were divided into two groups and supplemented with either water (control) or RO-treated DSW (diluted with deionized water at 1:20 [RO-treated DSW:deionized water] ratio). The control group was fed on a basal diet containing 0.21% salt. Five birds were slaughtered on each group and breast meat from carcasses was stored at $4^{\circ}C$ for 9 days. The proximate composition, fatty acid composition, cholesterol content, mineral content, pH value, water-holding capacity and Warner-Bratzler shear force value were not affected by RO-treated DSW supplementation. At 6 day of storage, lipid oxidation (2-thiobarbituric acid reactive substances) was significantly higher in RO-treated DSW group than in the control (P<0.05). With regard to meat color, CIE $L^*$ value was significantly lower in RO-treated DSW group than in the control after 6 day of storage (P<0.05), whereas CIE $a^*$ and $b^*$ values were not significantly different between two groups during storage. Consequently, RO-treated DSW supplementation led to a darker color and reduced the lipid oxidation stability in chicken meat during storage. Therefore, these results may indicate that RO-treated DSW can not be used as drinking water of chickens because it negatively affects the quality of chicken meat.

Effects of Antiscalant on Inorganic Fouling in Seawater Reverse Osmosis Membrane Processes (해수담수화 역삼투막 공정의 무기질오염에 대한 스케일 억제제 효과 연구)

  • Kang, Nam-Wook;Lee, Seock-Heon;Kweon, Ji-Hyang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.677-685
    • /
    • 2011
  • The reverse osmosis membrane processes have several operational problems. Fouling by inorganic scale occurs on membrane surface due to increases in concentrations over solubility by retaining ions on feed side of the membrane. Inorganic scales could be controlled by antiscalants or acid addition. In this study, three antiscalants having different characteristics were selected and evaluated on efficiency of $CaCO_3$ scale control. The $CaCO_3$ scale was inhibited by the antiscalants : 0.4 mg/L for SHMP, 0.6 mg/L for Spectra Guard, and 3 mg/L for Flocon 150 N. Increasing concentration factors of simulated sea water resulted in increases in antiscalant doses for the scale control. The increases in doses were positively proportional to the concentrate factors used in this study. Spectra Guard, one of the polyacrylate type antiscalants, was the most effective to control $CaCO_3$ scale. The antiscalants with the different scale inhibition time and doses implied the different control mechanisms.

RECENT DEVELOPMENTS OF MEMBRANE TECHNOLOGY IN JAPAN

  • Kimura, Shoji
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.5-12
    • /
    • 1991
  • Since the discovery of the Loeb-Sourirajan reverse osmosis membrane, thirty years have passed and many membrane technologies and new membranes for applications have been developed in the world. In the early stage of these developments Japan has not contributed much, but from the middle of 70ties Japan has started its own R&D projects starting from the desalination technology, and now various private industries and government ministries are actively engaging in R & D of membrane technologies in Japan. In Table 1 the chronological developments of important events of developments and projects relating membrane technologies inside and outside of Japan are introduced and their details will be explained. The first membrane technology applied in the Japanese industry was a electrodialysis(ED) process using ion-exchange membranes. These membranes were first developed in early 50ties and the Japanese government decided to use this method for concentration of sea-water to produce salt, which was then produced by solar evaporation. This development program started from 1960 by the Japan Monopoly Corp.(at that time). To apply ED process for sea-water concentration it was necessary to develop ion-exchange membranes having very low electric resistance to avoid energy loss due to Joule heat, and those having selectivity to permeate single valent ions only to avoid scale formation in the ED stacks. Three Japanese companies, Asahi Glass, Asahi Chemical and Tokuyama Soda, have succeeded to develop such membranes, and until 1971 all of the seven salt manufacturing companies had adopted ED for production of food salt.

  • PDF

An Economic Analysis of Desalination for Potential Application in Korea (국내 적용을 위한 해수 담수화 경제성 분석)

  • Park, No Suk;Park, Hee Kyung;Park, Mi Hyun;Kim, Byung Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.48-54
    • /
    • 1998
  • Korea becomes one of the countries which suffer from water shortage. It is expected that its water shortage in the early 2000's will be more than 10% of the annual demand. The shortage problem is more serious in the coastal areas where many industry complex locate. To solve the shortage problem, seawater desalination gets more attention as an alternative water supply source since Korea is surrounded by sea on its three sides. For potential application of seawater desalination in Korea, an economic analysis was conducted using cost data for the plants in the Middle Ease areas, The United states and others. The study is to provide a basis for the government to establish a strategy for promoting seawater desalination in Korea. It is discussed that the Reverse Osmosis (RO) process gets cheaper over times than the thermal processes of Multi-stage Flash Distillation (MSF) and Multi Effect Distillation (ME), especially in case where the capacity is less than about 50,000 ton/day. The unit cost of RO seawater is analyzed about US$1.35/ton in 1990 price. Since the Desalination plant can be operated regardless of weather conditions, industries in Korea's coastal areas which suffer from frequent droughts and water shortages are recommended to look into this option with more attention.

  • PDF

Graphene Oxide Incorporated Antifouling Thin Film Composite Membrane for Application in Desalination and Clean Energy Harvesting Processes (해수담수화와 청정 에너지 하베스팅을 위한 산화 그래핀 결합 합성 폴리머 방오 멤브레인)

  • Lee, Daewon;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.31 no.1
    • /
    • pp.16-34
    • /
    • 2021
  • Water supplies are decreasing in comparison to increasing clean water demands. Using nanofiltration is one of the most effective and economical methods to meet the need for clean water. Common methods for desalination are reverse osmosis and nanofiltration. However, pristine membranes lack the essential features which are, stability, economic efficiency, antibacterial and antifouling performances. To enhance the properties of the pristine membranes, graphene oxide (GO) is a promising and widely researched material for thin film composites (TFC) membrane due to their characteristics that help improve the hydrophilicity and anti-fouling properties. Modification of the membrane can be done on different layers. The thin film composite membranes are composed of three different layers, the top filtering active thin polyamide (PA) layer, supporting porous layer, and supporting fabric. Forward osmosis (FO) process is yet another energy efficient desalination process, but its efficiency is affected due to biofouling. Incorporation of GO enhance antibacterial properties leading to reduction of biofilm formation on the membrane surface. Pressure retarded osmosis (PRO) is an excellent process to generate clean energy from sea water and the biofouling of membrane is reduced by introduction of GO into the active layer of the TFC membrane. Different modifications on the membranes are being researched, each modification with its own advantages and disadvantages. In this review, modifications of nanofiltration membranes and their composites, characterization, and performances are discussed.

Comparative Analysis of Seawater Desalination Technology in Korea and Overseas (국내 및 해외의 해수담수화 기술 비교분석)

  • Hwang, Moon-Hyun;Kim, In S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.5
    • /
    • pp.255-268
    • /
    • 2016
  • Climate change has increased the need to secure a new water resource in addition to the traditional water resources such as surface water and ground water. The seawater desalination market is growing sharply in accordance with this situation in Korea, "seawater engineering & architecture of high efficiency reverse osmosis (SEAHERO)" program was launched in 2007 to keep pace with world market trend. SEAHERO program was completed in 2014, contributed to turn the domestic technology in evaporative desalination technology to RO desalination technology. Currently, it is investigated that the average specific energy consumption of the whole RO plant is around $3.5kWh/m^3$. The Busan Gi-jang plant has shown $3.7{\sim}4.0kWh/m^3$, including operational electricity for plant and maintenance building. Although not world top level, domestic RO technology is considered to be able to compete in desalination market. Separately, many researchers in the world are developing new technologies for energy savings. Various processes, forward osmosis (FO), membrane distillation (MD) process are expected to compete with RO in the future market. In Korea, FO-RO hybrid process, MD and pressure retarded osmosis (PRO) process are under development through the research program in Ministry of Land, Infrastructure and Transport (MOLIT). The desalination technology level is expected to decrease to $2.5kWh/m^3$.

Development of minimum-salinity feedwater for reduction of unit production cost of reverse-osmosis desalination plants (역삼투 담수화 시설의 생산단가 절감을 위한 저 염도 지하 기수 개발)

  • Park, Namsik;Jang, Chi Woong;Babu, Roshina
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.431-438
    • /
    • 2016
  • Large energy consumption is one of the main weaknesses of RO desalination. A new method is proposed to reduce the energy consumption of RO desalination which depends on the salinity of the feedwater. Low salinity feedwater can be obtained using groundwater wells which extracts both fresh groundwater and subsurface sea water. Subsurface feedwater is advantageous in overcoming other problems associated with surface seawater intakes. Salinities of groundwater depend on a number of factors. In this work a new simulation-optimization model is proposed to identify well locations and pumping rates with would provide the required design flow rate with the minimum salinity. When groundwater is developed in a coastal area, the saltwater wedge advances inland and may contaminate existing groundwater wells, which must be prevented. The model can protect existing wells while developing minimum salinity feedwater. Examples are provided to demonstrate the usage of the model.

Corrosive control of the water produced by SWRO and Application to small dimensional Pilot Plant (SWRO 생산수의 부식성 제어를 위한 목표 수질 연구 및 소규모 Pilot Plant 적용)

  • Kim, Min-Chul;Hwang, Kyu-Won;Woo, Dal-Sik;Yoon, Seok-Min;Moon, Jung-Gi;Kwak, Moung-Hwa
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.1042-1045
    • /
    • 2009
  • 역삼투식 해수담수화 (Sea Water Reverse Osmosis, SWRO) 공정에 의한 생산수는 pH가 낮고, 해수 내 존재하는 경도성분인 Ca, Mg 이온이 대부분 제거되기 때문에 상대적으로 매우 강한 부식성을 지니고 있다. 이를 음용수 및 공업용수로 이용 시 설비 및 배관계통에 심각한 부식문제를 유발할 수 있으며, 이를 방지하기 위한 처리공정과 부식성 제어 기술의 지속적인 개발이 요구되는 실정이다. SWRO 1단으로 처리 시 생산수의 전기전도도는 $150{\mu}S/cm$ 정도의 범위를 보이며, 2단 SWRO 과정을 거칠 시 전기전도도는 $100{\mu}S/cm$ 이하의 범위를 나타내는 것으로 알려져 있다. 본 연구에서는 SWRO 2단 처리수를 가정한 $20{\mu}S/cm{\sim}25{\mu}S/cm$ 범위의 전기전도도를 지닌 물을 실험 원수로 사용하여, 기존 방식제의 성분과 생산수의 특성을 고려한 효율적인 알칼리성 수처리제를 적용하고 그에 대한 부식성 제어 연구를 수행하였다. SWRO 생산수를 대상으로 부식방지기술을 개발하기 위해서는 부식제어와 관련된 수질 인자인 pH, 칼슘경도, 알칼리도의 조절과 LSI(Langelier Saturation Index)를 설정하는 것이 무엇보다도 중요하다. 본 연구에서는 해수담수화 공정의 생산수를 음용수 및 공업용수로 이용하기 위한 목표 수질을 pH 7.5~7.8, LSI 0 이상, 부가적으로 전기전도도는 $250{\mu}S/cm$ 이하로 설정하였으며, 연구목표 수질을 달성할 수 있는 부식억제제 및 알칼리성 수처리제의 적용을 통해 목표 수질에 대한 설정 근거를 마련하고자 하였다.

  • PDF

Research of Corrosion Control Technology for the Product Water of SWRO(Seawater Reverse Osmosis) by using liquid lime (액상소석회를 이용한 SWRO 생산수의 부식제어 연구)

  • Kim, Min-Chul;Hwang, Kyu-Won;Woo, Dal-Sik;Yoon, Seok-Min;Kwak, Myung-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.529-536
    • /
    • 2011
  • In this study, we confirmed that the SWRO(Sea Water Reverse Osmosis) production water has more hard corrosiveness than the tap water by fundamental experiment. According to the result, the target of this study was aimed at developing maintenance and anti-corrosion method. In the early stages of the research, batch tests using mild steel coupons and electrochemical experiments were applied to compare the corrosiveness between SWRO production water and the tap water. After then, two corrosion control methods for SWRO production water were applied. Liquid lime($Ca(OH)_2$) and Carbon Dioxide($CO_2$) were inserted and compared with the combination of liquid lime with phosphate corrosion inhibitor and carbon dioxide. The water qualities were evaluated through LSI(Langelier Saturation Index) and proper injection ratio was deduced by the result. Since then, simulated loop system test were performed to evaluate anti-corrosion effect depending on corrosion inhibitors. Subsequently, carbon steel pipes equipped at the loop system were detached for SEM, EDX and XRD analysis to acquire quantitative and qualitative data of the major corrosion products inside the pipes. In conclusion, the controled groups with anti-corrosion techniques applied were effective by appearing 97.4% and 90.9% of improvements in both case of liquid lime and the liquid lime with a phosphate corrosion Inhibitor. furthermore, major components of scale were iron oxides, on the other hand, protective effect of film formation by calcium carbonate($CaCO_3$) could be confirmed.