• 제목/요약/키워드: Sea water cooling system

검색결과 70건 처리시간 0.024초

2013~2017년 연안해역별 해양기상요소의 시·공간 변화 및 해무발생시 특성 분석 (Temporal and Spatial Variations of Marine Meteorological Elements and Characteristics of Sea Fog Occurrence in Korean Coastal Waters during 2013-2017)

  • 박소희;송상근;박형식
    • 한국환경과학회지
    • /
    • 제29권3호
    • /
    • pp.257-272
    • /
    • 2020
  • This study investigates the temporal and spatial variations of marine meterological elements (air temperature (Temp), Sea Surface Temperature (SST), and Significant Wave Height (SWH)) in seven coastal waters of South Korea, using hourly data observed at marine meteorological buoys (10 sites), Automatic Weather System on lighthouse (lighthouse AWS) (9 sites), and AWS (20 sites) during 2013-2017. We also compared the characteristics of Temp, SST, and air-sea temperature difference (Temp-SST) between sea fog and non-sea-fog events. In general, annual mean values of Temp and SST in most of the coastal waters were highest (especially in the southern part of Jeju Island) in 2016, due to heat waves, and lowest (especially in the middle of the West Sea) in 2013 or 2014. The SWH did not vary significantly by year. Wind patterns varied according to coastal waters, but their yearly variations for each coastal water were similar. The maximum monthly/seasonal mean values of Temp and SST occurred in summer (especially in August), and the minimum values in winter (January for Temp and February for SST). Monthly/seasonal mean SWH was highest in winter (especially in December) and lowest in summer (June), while the monthly/seasonal variations in wind speed over most of the coastal waters (except for the southern part of Jeju Island) were similar to those of SWH. In addition, sea fog during spring and summer was likely to be in the form of advection fog, possibly because of the high Temp and low SST (especially clear SST cooling in the eastern part of South Sea in summer), while autumn sea fog varied between different coastal waters (either advection fog or steam fog). The SST (and Temp-SST) during sea fog events in all coastal waters was lower (and more variable) than during non-sea-fog events, and was up to -5.7℃ for SST (up to 5.8℃ for Temp-SST).

LNG선박 열교환기 세관의 SCC에 미치는 용액의 온도의 영향 (The Effect of Temperature on SCC of Heat Exchanger Tube for LNG Vessel)

  • 정해규;임우조
    • 한국가스학회지
    • /
    • 제8권1호
    • /
    • pp.1-6
    • /
    • 2004
  • 선박용 열교환기의 냉각수로 사용되고 있는 해수의 입구온도는 스팀터빈콘덴서의 경우 약 $25^{\circ}C$이고 출구온도는 약 $60^{\circ}C$이며, 오일쿨러의 경우 출구온도는 약 $40^{\circ}C$이다. 이러한 해수의 온도 변화는 열교환기 세관재의 부식특성에 크게 영향을 미친다. 그러므로 부식손상을 최소화하면서 열교환 효율을 최대로 유지할 수 있는 냉각용액의 온도설정은 매우 중요하다. 따라서 본 연구에서는 $3.5\%$ NaCl + $0.1\%\;NH_4OH$ 수용액의 유동하에서 선박용 열교환기 세관재로 사용되고 있는 Al-황동의 분극 및 응력부식균열 실험을 실시하여 분극특성, 응력부식균열거동 및 탈아연특성에 미치는 용액의 온도의 영향에 대하여 고찰하였다.

  • PDF

지열발전을 위한 칼리나 사이클의 시뮬레이션 (Simulation of the Kalina cycle for a Geothermal Power Generation)

  • 백영진;김민성;장기창;이영수;박성룡;라호상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.782-787
    • /
    • 2008
  • The Kalina cycle simulation study was carried out for a preliminary design of a geothermal power generation system. The Kalina cycle system can be used for the utilization of a low-temperature heat sources such as geothermal and industrial waste heat that are not hot enough to produce steam. The sea/river water can be considered as a cooling media. A steady-state simulation model was developed to analyze and optimize its performance. The model contains a turbine, a pump, an expansion valve and heat exchangers. The turbine and pump were modelled by an isentropic efficiency, while a condenser, an evaporator and a regenerative heat exchanger were modeled by UA-LMTD method with a counter-flow assumption. The simulation results show that the power generation efficiency over 10% is expected when a heat source and sink inlet temperatures are $100^{\circ}C$ and $10^{\circ}C$ respectively.

  • PDF

채낚기 어선용 수랭식 LED 집어시스템의 설계 및 성능평가 (Design and performance estimation of fish-luring system using the water cooling typed LED lamp)

  • 배봉성;안희춘;권기진;박성욱;박창두;이경훈
    • 수산해양기술연구
    • /
    • 제47권2호
    • /
    • pp.79-87
    • /
    • 2011
  • A fishing lamp is fishing gear to gather fish in the night. But the cost of oil which is used to a light fishing lamp, goes significantly up to almost one hundred million won for 50 tonnage vessels and forty million won in case of vessels less than 10 tonnages. This cost has almost taken 30.40% of total fishing costs. As oil price increases, the business condition of the fishery gets worse and worse. Therefore, it is very urgent to develop an economical fishing lamp, to solve the problem of fishery's business difficulty. This research aims at developing a fishing lamp for squid jigging fishery and hairtail angling fishery using the LED, which has excellent efficiency and durability. One fishing lamp has about 160Watt capacity and five fishing lamps are installed one aluminium panel in which sea water flows to emit generated heat from LED to outside. Developed fishing lamp lights to an effective direction of jigging and angling operation. This fishing lamp can be controlled to light the direction of fish shoal because the aluminium panel can be controlled to up and down direction. The wave length of fishing lamp has white and blue color. White color light is to gather fish shoal of horizontal direction and blue color light is to gather fish shoal of vertical direction. After development of this fishing lamp, 60.110 units are established on the boat, and operated fishing. Consequently, in the case of squid jigging, spent energy was reduced to 39%, in the case of hairtail angling, 68% of spent energy was reduced. And the catch was more than another boat.

첨단복합방식재를 이용한 각종 선박구조물의 마찰마모손상의 최소화 (Minimization of Friction and Wear Damage of Marine Structures by Using the Advanced Anti-corrosive Composite Materials)

  • 김윤해;김진우
    • 해양환경안전학회지
    • /
    • 제5권2호
    • /
    • pp.15-26
    • /
    • 1999
  • The marine structures with sea water cooling system always expose to the oceanic atmosphere. Therefore, the protection of the equipments is very important. To investigate the effectiveness of advanced composite materials for the application in offshore environments, the tensile test, hardness test, undercutting property test, permeance test and the friction and wear test were carried out by using various applicable coating materials. The main results obtained can be summarized as follows; 1. The micro-hardness of the Archcoat 502B showed the highest value. 2. The coefficient of friction of the Rigspray coating at the speed of 2.21m/sec showed the lowest value, and that of the Archcoat 502B coating at 1.08m/sec and 0.18m/sec indicated the lowest values. 3. The wear mass at the speed of 0.18m/sec and 1.08m/sec in dry condition showed the smallest values. 4. The Archcoat 502B coating is fitted to the dynamic instruments in the range of low speed and middle speed. Rigspray coating is fitted to the dynamic instruments in the range of high speed. 5. The wear mass of five kinds of coating materials at the range of low speed was very small, and those of the Archcoat S02B, Archcoat 402B and Rigspray coating at high speed range were quitely smaller than those of the Modified Epoxy and Tar Epoxy.

  • PDF

해수 열교환기용 재료의 부식특성에 관한 전기 화학적 연구 (An Electrochemical Study on the Corrosion Property of Materials for Sea Water Heat Exchange System)

  • 김진경;김강희;김성종;박근현;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권1호
    • /
    • pp.99-107
    • /
    • 2002
  • Recently all kinds of structural materials are subjected to the severe corrosive environment. Especially corrosion problems of heat exchanger such as galvanic corrosion, erosion and cavitation raised by both contaminated solution and high velocity of fluid to increase cooling effect of heat exchanger have been frequently reported in these days. In this study two kinds of sheet materials and five kinds of tube materials are used for galvanic corrosion characteristics and their corrosion current density calculation. The tube materials having the most galvanic corrosion resistance between tube and sheet of heat exchanger were Al Brass(68700) and Al Brass(C6872TS) and although Ti tube predominantly indicated the highest individual corrosion resistance among those five tube materials. it appeared that Ti tube can be allowed as sheet materials to get galvanic corrosion easily. However it is considered that Cu-Ni tube materials is not only easy to produce galvanic corrosion significantly between tube and sheet regardless of kinds of sheet materials but also is appeared considerably its own high corrosion current density

1차원 모델상에서 태풍통과시의 혼합층 수온 변화 (Temperature Variations in the Mixed Layer with the Passage of Typhoons Using One-Dimensional Numerical Model)

  • 홍철훈;마스다 아키라
    • 한국수산과학회지
    • /
    • 제51권1호
    • /
    • pp.107-112
    • /
    • 2018
  • One-dimensional numerical model is implemented to investigate temperature variations in the mixed layer depth (MLD) with the passage of typhoons. In the model, we assume a non-divergent, infinite ocean and consider wind effects only, excluding isostatic effects (inverse barometric effects) and upwelling with vertical movement of the water column. Numerical experiments investigate the effects of typhoon tracks on temperature variations, including their dependence on vertical resolutions in the MLD and these results are compared with those in a three-dimensional primitive equation model (POM). The model reproduces features of the observed temperature variations in the MLD fairly well, and implies that wind effects, rather than isostatic effects, play a predominant role in temporal and spatial temperature variations in the MLD. After the passage of typhoons, however, the model does not reproduce well the temperature variations observed in the MLD, because a limitation of the model is its inability to reproduce events such as cyclonic eddy formation (Hong et al., 2011; Masuda and Hong, 2011). The model also shows well the so called 'rightward bias' (Price, 1981) of sea surface cooling which is the most predominant in the right hand side of typhoon's track.

헬리컬 조류수차 설치로 인한 발전소 배수로 계통 영향 분석 (Analysis of Impact on the Circulating Water System due to an Installation of Helical Current Turbine at the Discharge Channel of the Power Plant)

  • 김지영;강금석;유무성
    • 한국해안·해양공학회논문집
    • /
    • 제22권2호
    • /
    • pp.67-72
    • /
    • 2010
  • 본 연구에서는 조류발전용 헬리컬 수차를 발전소 냉각수 배수로에서의 수력 개발에 이용하기 위하여 수차구조물의 설치로 인한 수위 증가가 냉각수 순환 계통에 미치는 영향을 파악하였다. 배수로 암거 출구부에 가로 3.6 m $\times$ 세로 1.5 m의 헬리컬 수차 1 set(2기 일체형)를 설치하는 경우에 대하여 배수로의 수위변화 및 압력변화를 수치해석을 통해 분석한 결과, 평균해수위시에는 seal well 하류의 수위 변화 영향이 seal well의 weir에 의해 차단되어 상류로 전파되지 않았다. 그러나 고조시에는 weir의 월류 흐름형태가 잠김 월류가 되고 seal well 전 후단이 모두 만관흐름상태가 되어 하류의 압력변화가 상류로 전파되었다. 방류 개시 후 약 10분간 불안정한 압력변화가 발생하나 이후 안정되며, 약 0.2 m 내외의 수두 증가로 냉각수 순환펌프 소요 동력이 증가할 수 있으나 안전성에는 영향을 주지 않을 것으로 판단되었다. 따라서, 수력 개발 타당성 평가시 냉각수 순환펌프의 소요전력 증가를 고려할 필요가 있다.

CFD를 이용한 선박용 해수펌프의 공동현상에 대한 분석 (Cavitation Analysis on Ship Seawater Pump Using CFD)

  • 김부기;김홍렬;양창조;김준호
    • 해양환경안전학회지
    • /
    • 제23권4호
    • /
    • pp.400-406
    • /
    • 2017
  • 선박용 입형 편흡입 원심 해수펌프의 회전체와 파이프 시스템 내부에 발생한 과도한 손상의 원인을 분석하고자 실제 모델을 역설계 하였다. 이를 위해 전산유체역학(CFD)을 이용하여 해수냉각펌프의 내부유동 분석을 실시하였다. 결과적으로 역설계를 통한 대상펌프의 형상 및 경계조건을 설정하여 설계 운전점인 $125m^3/h$에서의 펌프 효율은 85.3 %, 양정 32.0미터로 계산되었다. 대상 펌프의 최고 효율점은 $150m^3/h$에서 약 86.2 %로 예측되었으나 실제 운전점과는 차이가 있었다. 최저 유량점인 $112.5m^3/h$에서는 저 유량점 특성상 유동이 불안정하여 해석의 수렴이 좋지 않았다. 선박에서 운전 중인 해수펌프 및 파이프 시스템 전반에 걸쳐 진행 중인 공동현상의 원인 규명을 통해 개선방안을 도출하고자 하였으나, 입 출구 전체 파이프 시스템의 계산, 각 지관들에 대한 유량 및 유속 측정 등을 통해 보다 명확한 원인분석을 위한 후속연구가 필요하다.

Three-dimensional Numerical Prediction on the Evolution of Nocturnal Thermal High (Tropical Night) in a Basin

  • Choi, Hyo;Kim, Jeong-Woo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제25권1호
    • /
    • pp.57-81
    • /
    • 1997
  • Numerical prediction of nocturnal thermal high in summer of the 1995 near Taegu city located in a basin has been carried out by a non-hydrostatic numerical model over complex terrain through one-way double nesting technique in the Z following coordinate system. Under the prevailing westerly winds, vertical turbulent fluxes of momentum and heat over mountains for daytime hours are quite strong with a large magnitude of more than $120W/\textrm{m}^2$, but a small one of $5W/\textrm{m}^2$ at the surface of the basin. Convective boundary layer (CBL) is developed with a thickness of about 600m over the ground in the lee side of Mt. Hyungje, and extends to the edge of inland at the interface of land sea in the east. Sensible heat flux near the surface of the top of the mountain is $50W/\textrm{m}^2$, but its flux in the basin is almost zero. Convergence of sensible heat flux occurs from the ground surface toward the atmosphere in the lower layer, causing the layer over the mountain to be warmed up, but no convergance of the flux over the basin results from the significant mixing of air within the CBL. As horizontal transport of sensible heat flux from the top of the mountain toward over the basin results in the continuous accumulation of heat with time, enhancing air temperature at the surface of the basin, especially Taegu city to be higher than $39.3^{\circ}C$. Since latent heat fluxes are $270W/\textrm{m}^2$ near the top of the mountain and $300W/\textrm{m}^2$ along the slope of the mountain and the basin, evaporation of water vapor from the surface of the basin is much higher than one from the mountain and then, horizontal transport of latent heat flux is from the basin toward the mountain, showing relative humidity of 65 to 75% over the mountain to be much greater than 50% to 55% in the basin. At night, sensible heat fluxes have negative values of $-120W/\textrm{m}^2$ along the slope near the top of the mountain and $-50W/\textrm{m}^2$ at the surface of the basin, which indicate gain of heat from the lower atmosphere. Nighttime radiative cooling produces a shallow nocturnal surface inversion layer with a thickness of about 100m, which is much lower than common surface inversion layer, and lifts extremely heated air masses for daytime hours, namely, a warm pool of $34^{\circ}C$ to be isolated over the ground surface in the basin. As heat transfer from the warm pool in the lower atmosphere toward the ground of the basin occurs, the air near the surface of the basin does not much cool down, resulting in the persistence of high temperature at night, called nocturnal thermal high or tropical night. High relative humidity of 75% is found at the surface of the basin under the moderate wind, while slightly low relative humidity of 60% is along the eastern slope of the high mountain, due to adiabatic heating by the srong downslope wind. Air temperature near the surface of the basin with high moisture in the evening does not get lower than that during the day and the high temperature produces nocturnal warming situation.

  • PDF