• 제목/요약/키워드: Screws

검색결과 646건 처리시간 0.028초

Clinical courses and degradation patterns of absorbable plates in facial bone fracture patients

  • Kim, Young Min;Lee, Jong Hun
    • 대한두개안면성형외과학회지
    • /
    • 제20권5호
    • /
    • pp.297-303
    • /
    • 2019
  • Background: Absorbable plates are widely used in open reduction and internal fixation surgeries for facial bone fractures. Absorbable plates are made of polyglycolic acid (PGA), polylactic acid (PLA), polydioxane (PDS), or various combinations of these polymers. The degradation patterns of absorbable plates made from different polymers and clinical courses of patients treated with such plates have not been fully identified. This study aimed to confirm the clinical courses of facial bone fracture patients using absorbable plates and compare the degradation patterns of the plates. Methods: A retrospective chart review was conducted for 47 cases in 46 patients who underwent open reduction and internal fixation surgery using absorbable plates to repair facial bone fractures. All surgeries used either PLA/PGA composite-based or poly-L-lactic acid (PLLA)/hydroxyapatite (HA) composite-based absorbable plates and screws. Clinical courses were confirmed and comparisons were conducted based on direct observation. Results: There were no naturally occurring foreign body reactions. Post-traumatic inflammatory responses occurred in eight patients (nine cases), in which six recovered naturally with conservative treatment. The absorbable plates were removed from two patients. PLA/PGA compositebased absorbable plates degraded into fragments with non-uniform, sharp surfaces whereas PLLA/HA composite-based absorbable plates degraded into a soft powder. Conclusion: PLA/PGA composite-based and PLLA/HA composite-based absorbable plates showed no naturally occurring foreign body reactions and showed different degradation patterns. The absorbable plate used for facial bone fracture surgery needs to be selected in consideration of its degradation patterns.

Biomechanical Study of Posterior Pelvic Fixations in Vertically Unstable Sacral Fractures: An Alternative to Triangular Osteosynthesis

  • Chaiyamongkol, Weera;Kritsaneephaiboon, Apipop;Bintachitt, Piyawat;Suwannaphisit, Sitthiphong;Tangtrakulwanich, Boonsin
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.967-972
    • /
    • 2018
  • Study Design: Biomechanical study. Purpose: To investigate the relative stiffness of a new posterior pelvic fixation for unstable vertical fractures of the sacrum. Overview of Literature: The reported operative fixation techniques for vertical sacral fractures include iliosacral screw, sacral bar fixations, transiliac plating, and local plate osteosynthesis. Clinical as well as biomechanical studies have demonstrated that these conventional techniques are insufficient to stabilize the vertically unstable sacral fractures. Methods: To simulate a vertically unstable fractured sacrum, 12 synthetic pelvic models were prepared. In each model, a 5-mm gap was created through the left transforaminal zone (Denis zone II). The pubic symphysis was completely separated and then stabilized using a 3.5-mm reconstruction plate. Four each of the unstable pelvic models were then fixed with two iliosacral screws, a tension band plate, or a transiliac fixation plus one iliosacral screw. The left hemipelvis of these specimens was docked to a rigid base plate and loaded on an S1 endplate by using the Zwick Roell z010 material testing machine. Then, the vertical displacement and coronal tilt of the right hemipelves and the applied force were measured. Results: The transiliac fixation plus one iliosacral screw constructions could withstand a force at 5 mm of vertical displacement greater than the two iliosacral screw constructions (p=0.012) and the tension band plate constructions (p=0.003). The tension band plate constructions could withstand a force at $5^{\circ}$ of coronal tilt less than the two iliosacral screw constructions (p=0.027) and the transiliac fixation plus one iliosacral screw constructions (p=0.049). Conclusions: This study proposes the use of transiliac fixation in addition to an iliosacral screw to stabilize vertically unstable sacral fractures. Our biomechanical data demonstrated the superiority of adding transiliac fixation to withstand vertical displacement forces.

The effect of fixation plate use on bone healing during the reconstruction of mandibular defects

  • Hong, Khang Do Gia;Kim, Seong-Gon;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권5호
    • /
    • pp.276-284
    • /
    • 2019
  • Objectives: This study sought to compare efficiency results between the use of a customized implant (CI) and a reconstruction plate (RP) in mandibular defect reconstruction in an animal model. Materials and Methods: Fifteen rabbits underwent surgery to create a defect in the right side of the mandible and were randomly divided into two groups. For reconstruction of the mandibular defect, the RP group (n=5) received five-hole mini-plates without bone grafting and the CI group (n=10) received fabricated CIs based on the cone-beam computed tomography (CBCT) data taken preoperatively. The CI group was further divided into two subgroups depending on the time of CBCT performance preoperatively, as follows: a six-week CI (6WCI) group (n=5) and a one-week CI (1WCI) group (n=5). Daily food intake amount (DFIA) was measured to assess the recovery rate. Radiographic images were acquired to evaluate screw quantity. CBCT and histological examination were performed in the CI subgroup after sacrifice. Results: The 1WCI group showed the highest value in peak average recovery rate and the fastest average recovery rate. In terms of reaching a 50% recovery rate, the 1WCI group required the least number of days as compared with the other groups ($2.6{\pm}1.3days$), while the RP group required the least number of days to reach an 80% recovery rate ($7.8{\pm}2.2days$). The 1WCI group showed the highest percentage of intact screws (94.3%). New bone formation was observed in the CI group during histological examination. Conclusion: Rabbits with mandibular defects treated with CI showed higher and faster recovery rates and more favorable screw status as compared with those treated with a five-hole mini-plate without bone graft.

Palatal en-masse retraction of segmented maxillary anterior teeth: A finite element study

  • Park, Jae Hyun;Kook, Yoon-Ah;Kojima, Yukio;Yun, Sunock;Chae, Jong-Moon
    • 대한치과교정학회지
    • /
    • 제49권3호
    • /
    • pp.188-193
    • /
    • 2019
  • Objective: The aim of this finite element study was to clarify the mechanics of tooth movement in palatal en-masse retraction of segmented maxillary anterior teeth by using anchor screws and lever arms. Methods: A three-dimensional finite element method was used to simulate overall orthodontic tooth movements. The line of action of the force was varied by changing both the lever arm height and anchor screw position. Results: When the line of action of the force passed through the center of resistance (CR), the anterior teeth showed translation. However, when the line of action was not perpendicular to the long axis of the anterior teeth, the anterior teeth moved bodily with an unexpected intrusion even though the force was transmitted horizontally. To move the anterior teeth bodily without intrusion and extrusion, a downward force passing through the CR was necessary. When the line of action of the force passed apical to the CR, the anterior teeth tipped counterclockwise during retraction, and when the line of action of the force passed coronal to the CR, the anterior teeth tipped clockwise during retraction. Conclusions: The movement pattern of the anterior teeth changed depending on the combination of lever arm height and anchor screw position. However, this pattern may be unpredictable in clinical settings because the movement direction is not always equal to the force direction.

Root proximity of the anchoring miniscrews of orthodontic miniplates in the mandibular incisal area: Cone-beam computed tomographic analysis

  • Jeong, Do-Min;Oh, Song Hee;Choo, HyeRan;Choi, Yong-Suk;Kim, Seong-Hun;Lee, Jin-Suk;Hwang, Eui-Hwan
    • 대한치과교정학회지
    • /
    • 제51권4호
    • /
    • pp.231-240
    • /
    • 2021
  • Objective: This outcome analysis study evaluated the actual positions of the orthodontic miniplate and miniplate anchoring screws (MPASs) and the risk factors affecting adjacent anatomic structures after miniplate placement in the mandibular incisal area. Methods: Cone-beam computed tomographic images of 97 orthodontic miniplates and their 194 MPASs (diameter, 1.5 mm; length, 4 mm) in patients whose miniplates provided sufficient clinical stability for orthodontic treatment were retrospectively reviewed. For evaluating the actual positions of the miniplates and analyzing the risk factors, including the effects on adjacent roots, MPAS placement height (PH), placement depth (PD), plate angle (PA), mental fossa angle (MA), and root proximity were assessed using the paired t-test, analysis of variance, and generalized linear model and regression analyses. Results: The mean PDs of MPASs at positions 1 (P1) and 2 (P2) were 2.01 mm and 2.23 mm, respectively. PA was significantly higher in the Class III malocclusion group than in the other groups. PH was positively correlated with MA and PD at P1. Of the 97 MPASs at P1, 49 were in the no-root area and 48 in the dentulous area; moreover, 19 showed a degree of root contact (19.6%) without root perforation. All MPASs at P2 were in the no-root area. Conclusions: Positioning the miniplate head approximately 1 mm lower than the mucogingival junction is highly likely to provide sufficient PH for the P1-MPASs to be placed in the no-root area.

한 쌍의 L-형 모노폴 슬롯 공진기를 이용한 X-밴드 트랜지스터 발진기 설계 (Design of transistor oscillator for X-band application using a pair of L-shaped monopole slot resonator)

  • 이영민;이영순
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권1호
    • /
    • pp.107-114
    • /
    • 2021
  • 본 논문에서는 새롭게 제안되는 L-형 모노폴 슬롯 공진기를 이용한 X-band용 평면형 트랜지스터 발진기를 제안하였다. 평면형 설계를 위해 끝이 개방된 L자형 모노폴 슬롯을 트랜지스터 발진기의 공진기로 사용하였다. 3단계를 통한 공진기의 모의 실험 설계 결과 1169.84의 높은 Q 값과 49.934 dB의 높은 삽입 손실을 확인하였다. 최종 설계 및 제작된 발진기의 측정결과 7 dBm 이상의 발진 출력과 100 kHz 오프셋에서 - 58 dBc/Hz의 양호한 위상 잡음 특성을 가지는 것을 확인하였다. 제안된 발진기는 평면형으로 마이크로파 집적회로 기술에 직접 적용할 수 있다는 장점을 가지고 있다. 또한 DRO(유전체 공진 발진기)의 경우처럼 3D 구조의 금속 공동, 튜닝 스크류 등 추가 기기 없이 마이크로스트립 형태로만 구현할 수 있어 크기를 줄일 수 있다는 장점도 있다.

Evaluation of Bearing Strength of Self-Tapping Screws according to the Grain Direction of Domestic Pinus densiflora

  • LEE, In-Hwan;KIM, Keonho;SHIM, Kug-bo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권1호
    • /
    • pp.1-11
    • /
    • 2022
  • To evaluate the bearing strength of red pine cross-laminated timber (CLT) with self-tapping screw (STS), which is widely used as a fastener for connection in CLT building, the bearing test was conducted. Accoring to the STS's diameters (8, 10, 12 mm), the bearing test specimens with half hole were manufactured. Bearing strength was compared and reviewed in consideration of the configuration in STS and the loading direction to the grain of red pine. As a result of the bearing test on the STS's diameter, the yield bearing load increases as the larger diameter of the STS in all directions of the red pine. The bearing strength of the thread part (thread + tip) was higher than the shank part (shank + shank cutter). In compared with the directions to the grain of red pine, the bearing strength of the cross section parallel to the loading direction was the highest, and the tangent section was the lowest bearing strength. The average bearing strength of the loading direction in parallel to the grain was 23.43 MPa, which was about 45% higher than the average 16.16 MPa in perpendicular to the grain. The predicted bearing strength calculated by Eurocode (EN) and Korean Building Code (KBC)'s equation was lower than the experimental value. It is nessesary to propose the new equations of bearing strength reflected the configuration information of STS.

티타늄 및 PEEK 지대주 소재가 임플란트 유지 수복물 및 주위 지지골 응력 분포에 미치는 영향: 3차원 유한요소해석 (Effects of titanium and PEEK abutments on implant-supported dental prosthesis and stress distribution of surrounding bones: three-dimensional finite element analysis)

  • 홍민호
    • 대한치과기공학회지
    • /
    • 제44권3호
    • /
    • pp.67-75
    • /
    • 2022
  • Purpose: This study aimed to comparatively evaluate the stress distribution of bones surrounding the implant system to which both titanium and polyetheretherketone (PEEK) abutments are applied using a three-dimensional finite element analysis. Methods: The three-dimensional implant system was designed by the computer-aided design program (CATIA; Dassault Systemes). The discretization process for setting nodes and elements was conducted using the HyperMesh program (Altair), after finishing the design of each structure for the customized abutment implant system. The results of the stress analysis were drawn from the Abaqus program (Dassault Systèmes). This study applied 200 N of vertical load and 100 N of oblique load to the occlusal surface of a mandibular first molar. Results: Under external load application, the PEEK-modeled dental implant showed the highest von Mises stress (VMS). The lowest VMS was observed in the Ti-modeled abutment screws. In all groups, the VMS was observed in the crestal regions or necks of implants. Conclusion: The bones surrounding the implant system to which the PEEK abutment was applied, such as the cortical and trabecular bones, showed stress distribution similar to that of the titanium implant system. This finding suggests that the difference in the abutment materials had no effect on the stress distribution of the bones surrounding implants. However, the PEEK abutments require mechanical and physical properties improved for clinical application, and the clinical application is thought to be limited.

슬관절 인공관절 치환술 중 발생한 내측 측부 인대 견열 골절에 대해 생흡수성 봉합 나사못을 이용한 고정 후 발생한 골용해 (Osteolysis-Related Bioabsorbable Suture Anchor Fixation in a Medial Collateral Ligament Avulsion Fracture during Total Knee Arthroplasty)

  • 허정욱;박만준;홍성확;박준형
    • 대한정형외과학회지
    • /
    • 제55권6호
    • /
    • pp.545-549
    • /
    • 2020
  • 슬관절 인공관절 치환술 중 드물게 발생하는 내측 측부 인대 견열 골절의 치료는 보조기나 캐스트 등의 보존적 치료, 금속 나사못을 이용한 고정 등의 다양한 치료법이 소개되고 있다. 생흡수성 봉합 나사못은 생체 적합성, 방사선 투과성, 제거를 위한 2차 수술이 불필요하다는 장점 등으로 여러 부위에서 금속 고정물을 대체해 사용되고 있으나 골용해 등의 합병증이 보고되고 있다. 저자들은 슬관절 인공관절 치환술 중 발생한 내측 측부 인대 견열 골절에 대해 생흡수성 봉합 나사못을 이용한 고정 후 심각한 골용해 소견을 경험하여 사용에 신중을 기해야 한다는 판단하에 이에 대한 문헌 고찰과 함께 보고하고자 한다.

요골 간부 골절 치료 후 지연 발견된 원위 척골의 전방 탈구 (Delayed Diagnosis of Volar Dislocation of the Distal Ulna after Treatment of the Radial Shaft Fracture)

  • 전숙하;이상림
    • 대한정형외과학회지
    • /
    • 제56권5호
    • /
    • pp.427-432
    • /
    • 2021
  • 원위 요척 관절의 전방 탈구 치료가 지연된 경우에는 수근부 통증과 전완의 회전 운동의 제한이 동반되어 결국 구제술이 필요한 퇴행성 관절염이 발생할 수 있다. 24세 남자가 요골 간부 골절 수술 후 통증과 회전 운동 제한으로 내원하였다. 금속판으로 고정된 요골의 간부에서 7도의 전방 각형성이 관찰되었으며 척골 두가 전방으로 탈구되어 회외전에서 결손부가 요골의 S자 절흔 전방 경계에 걸려 탈구가 지속되는 소견이 관찰되었다. 부정 유합된 요골의 교정의 절골술과 척골 두 골결손 근위부의 골을 원위 결손 부위로 이동시키는 절골술을 시행하여 원위 요척 관절이 전완의 회전에 안정적으로 정복이 유지되도록 하였다. 수술 후 19개월에 전완 회전 운동 범위와 통증이 개선된 것을 확인하였다.