• Title/Summary/Keyword: Screws

Search Result 646, Processing Time 0.03 seconds

Characteristics of Symmetric-Shape Parts Shearing on Micro NCT (마이크로 NCT에 의한 대칭형상구멍의 전단특성)

  • Hong N. P.;Kim B. H.;Chang I. B.;Kim H. Y.;Oh S. I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.02a
    • /
    • pp.285-291
    • /
    • 2002
  • The shearing process for the sheet metal is normally used in the precision elements such as a frame of TFT-LCD or lead frame of If chips. In these precision elements, the burr formation prevents the system assembly and needs the additional burr removing process. In this paper, we developed the small size NC punching system which has an aligning kinematics between the rectangular shaped punch and die. The punch is driven by an ai cylinder and the sheet metal is moving on the X-Y table system which is driven by two stewing motors. The microprocessor control the whole system and communicate with the monitoring PC by RS232C serial communication protocol. The graphic user interface program in PC monitors nil control the punching system. The cross shaped joint hinge supports the punching die and positioned by two differential screws, whose are installed in perpendicular directions. The aligning between the punch and die is performed using the sheets of half thickness(0.1mm Brass) of the real process for the frame of the TFT-LCD. Using half thickness Brass, the burr formation is magnified and we can decide the aligning direction more easily then using the real thickness(0.2mm) Aluminum. In this paper, the aligning results are measured manually using the SEM photographs and we hope to make the automated aligning procedures using some kinds of image processing techniques.

  • PDF

Development of Three D.O.F Alignment Stage for Vacuum Environment (진공용 3자유도 얼라인먼트 스테이지 개발)

  • Han, Sang-Jin;Park, Jong-Ho;Park, Hui-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.138-147
    • /
    • 2001
  • Alignment systems are frequently used under various semiconductor manufacturing environment. Particularly in PDP(Plasma Display Panel) manufacturing process, the alignment system is applied to the combining and sealing processes of the upper and lower glass panels of PDP, where these processes are performed in the vacuum chamber of high vacuum and high temperature. In this paper, the XYΘ-alignment stage is developed to align PDP panels. Because of high vacuum and high temperature environment, the alignment chamber has been designed to isolate the inner part of the alignment chamber from the outer environment of high vacuum and high temperature, in which every part of the alignment stage is inserted. As it is difficult to attach feedback sensors to the alignment stage in the alignment chamber, the alignment stage is implemented with the open loop algorithm, where the parallel link structure has been designed using step-motors and ball-screws for structural simplicity. The kinematic analysis is performed to drive the parallel link structure, based on the experiments of actuation-compensation of the alignment stage. For the error compensation, the hyperpatch model has been used to model the errors. From the experiments, the positional accuracy of the alignment stage can be improved significantly.

  • PDF

Holding Strength of Screw in Domestic Particleboard and Medium Density Fiberboard(II) -Predicting Formula of Withdrawal Strength of Screw- (국산(國産) 파티클보드와 중밀도섬유판의 나사못유지력(維持力)(II) -나사못 유지력(維持力) 예측식(預測式)-)

  • Lee, Phil-Woo;Park, Hee-Jun;Han, Yu-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.43-51
    • /
    • 1991
  • This study was carried out to determine the withdrawal strength of various screws according to root diameter of screw and embeded length on the face and edge of domestic particleboard and medium density fiberboard. The obtained results were as follows: 1. The withdrawal strength of screw in domestic particleboard and medium density fiberboard was closely related to embeded length of the screw but less dependent on root diameter of the screw. 2. The withdrawal strength on the face and edge of domestic particleboard could be predicted by means of the following expression: $F_{Pf}=4.60{\times}D^{0.24}{\times}L^{1.14}(R^2=0.87)$ $F_{Pe}=0.54{\times}D^{0.43}{\times}L^{1.73}(R^2=0.84)$ Where: $F_{Pf}$ : withdrawal strength on the face of particleboard(kgf) $F_{Pe}$=withdrawal strength on the edge of particleboard(kgf) D=diameter of the screw(mm) L=embeded length(mm) 3. The withdrawal strength on the face and edge of domestic medium density fiberboard could he predicted by means of the following expression: $FM_f=1.53{\times}D^{0.53}{\times}L^{1.39}(R^2=0.93)$ $F_{Me}=1.14{\times}D^{0.66}{\times}L^{1.36}(R^2=0.87)$ where: $F_{Mf}$ = withdrawal strength on the face of medium density fiberboard(kgf) $F_{Mf}$=withdrawal strength on the edge of medium density fiberboard(kgf).

  • PDF

Titanium Plate Fixation for Sternal Dehiscence in Major Cardiac Surgery

  • Kim, Wan Kee;Kim, Joon Bum;Kim, Gwan Sic;Jung, Sung-Ho;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.279-284
    • /
    • 2013
  • Background: Sternal dehiscence is one of the most troublesome complications following cardiac surgery. Treatment failure and consequent lethal outcomes are very common. The aim of this study was to evaluate titanium plate fixation as a treatment for sternal dehiscence following major cardiac surgery. Materials and Methods: Between 2010 and 2012, 17 patients underwent sternal reconstruction using horizontal titanium plating for the treatment of post-cardiac-surgery sternal dehiscence. The plates were cut and shaped, and then were fixed to corresponding costal segments using 2-3 titanium screws per each side. Results: The median age of our patients was 66 years (range, 50 to 78 years) and 9 were female. Indications for sternal reconstruction included aseptic sternal dehiscence in 3 patients and osteomyelitis in 14 patients including 6 patients who were diagnosed with mediastinitis. During the operation, sternal resection and autologous flap interposition were combined in 11 patients. One patient died due to sepsis. Two patients required additional soft tissue wound revisions. Another patient presented with a tuberculous wound infection which was resolved using anti-tuberculosis medications. The postoperative course was uncomplicated in the other 13 patients. Conclusion: Titanium plate fixation that combines appropriate debridement and flap interposition is very effective for the treatment of sternal dehiscence following major cardiac surgery.

Change in Kinematics of the Spine after Insertion of an Interspinous Spacer for the Treatment of the Lumbar Spinal Stenosis

  • Lee H. S.;Moon S. J.;Kwon S. Y.;Jung T. G.;Shin K. C.;Lee K. Y.;Lee S. J.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.3
    • /
    • pp.151-155
    • /
    • 2005
  • Interspinous spacers have been developed as an alternative surgical treatment for laminectomy or fusion with pedicle screws and rods for the treatment of lumbar spinal stenosis. However, its biomedical efficacies are well not known. In this study, we evaluated kinematic behaviors of the surgical and the adjacent levels before and after inserting interspinous spacers. Three porcine lumbar spines were prepared. On each specimen, an interspinous spacer was inserted at the L4-L5. Flexion-extension moments (0, 2.5, 5.0, 7.5, 10Nm) were applied. A stereophotogrammetric set-up with DLT algorithm was used to assess the three-dimensional motions of the specimen where three markers $({\square}0.8mm)$ were attached to each vertebra. Results showed that extension motion decreased by $15-24\%$ at the surgical level (L4-L5) after insertion of interspinous spacer. At the adjacent levels, the range of motion remained unchanged. In flexion, no significant changes in motion were observed regardless of levels. Therefore, our experimental results demonstrated the interspinous spacer is very effective in limiting the extension motion that may cause narrowing of the spinal canal and vertebral foramen while maintaining kinematic behaviors at the adjacent levels. Further, these results suggested that the use of interspinous spacer may be able to prevent lower back pain at the surgical level and to lower the incidence of degenerative changes at the adjacent levels.

Transposition Lateral Arm Flap for Coverage of the Elbow Defects (전이형 외측 상완 피판술을 이용한 주관절 연부조직 결손의 피복)

  • Song, Joo-Hyoun;Lee, Yoon-Min;Lee, Joo-Yup
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.2
    • /
    • pp.82-86
    • /
    • 2008
  • Purpose: Soft tissue defect can occur on the posterior aspect of the elbow after trauma or fracture fixation. To cover the defect and maintain elbow functions, various flap surgeries including latissimus dorsi muscle flap, lateral arm flap and radial forearm flap can be performed. We present the clinical results of transposition lateral arm flap for coverage of the elbow defect and discuss the cause of posterior soft tissue necrosis after fracture fixation. Materials and Methods: Two patients who had posterior soft tissue defect of the elbow after open reduction of the fractures around the elbow were treated with transposition lateral arm flap. The mean size of skin defect was 20 $cm^2$. The flap was elevated with posterior radial collateral artery pedicle and transposed to the defect area. Donor defect was covered with split thickness skin graft. The elbow was immobilized for 1 week in extended position and active range of motion was permitted. Results: All two cases of transposition lateral arm flap survived without marginal necrosis. The average range of motion of the elbow was 10~115 degrees. Mayo elbow performance score was 72 and Korean DASH score was 23. Conclusion: When elbow fractures are fixed with three simultaneous plates and screws, skin necrosis can occur on the posterior aspect of the elbow around olecranon area. If the size of skin defect is relatively small, transposition lateral arm flap is very useful option for orthopaedic surgeons without microsurgical technique.

  • PDF

THE EFFECT OF PREPARATION PROCEDURE ON IMPLANT-ABUTMENT JOINT STABILITY (임플랜트 지대주의 삭제과정이 결합부 안정성에 미치는 영향)

  • Lee Jang-Wook;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.662-670
    • /
    • 2005
  • Statement of problem: Little is known about the effect of abutment preparation procedure on do-torque values in different implant platform and the relationship of final do-torque values with different implant platform size. Purpose: This study evaluated the effect of abutment preparation procedure on do-torque values in different implant platform and the relationship of final do-torque values with different implant platform size. Material and method: Six ITI implants (2 narrow-neck implants, 2 regular-neck implants, 2 wide-neck implants) and six Branemark implants (2 narrow platforms, 2 regular platforms, 2 wide platforms) were embedded in each acrylic resin block with epoxy resin. Eighteen $synOcta^(R)$ abutments (6 narrow-neck implant-abutments, 6 regular-neck implant-abutments, 6 wide-neck implant-abutments) and eighteen esthetic abutments (6 narrow platform-abutments, 6 regular platform-abutments, 6 wide platform-abutments) were tightened to each implant with digital torque gauge. Initial do-torque values were measured using digital torque gauge. After preparation of abutments, Final do-torque values were measured with digital torque gauge. Results and conclusion: 1. Screws loosening or abutments motion were not detected in all experimental group, but some scratches of implant-abutment joints were detected in all group 2. Reduction ratios of final do-torque values were greater than initial do-torque values in all measured group, except in narrow-neck implant-abutment group (p<0.05). 3. Reduction ratios of final do-torque values in wide-neck implant-abutment group were greater than regular-neck implant-abutment group (p<0.01). 4. The greatest standard deviation value was detected in wide platform group in both implant systems.

FIT OF IMPLANT FRAMEWORKS FABRICATED BY ONE-PIECE CASTING, LASER WELDING, SOLDERING, AND ELECTRIC DISCHARGE MACHINING (일체주조법, 레이저용접법, 납착법, 방전가공법에 의해 제작된 임플란트 보철물의 적합도에 관한 연구)

  • Seol, Young-Hoon;Jeong, Chang-Mo;Jeon, Young-Chan;Kang, Sung-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.156-171
    • /
    • 2002
  • The purpose of this study was to measure and compare the strains produced by screw-tightening implant frameworks fabricated by aye different fabrication methods; (1) one-piece cast using plastic sleeve, (2) one-piece cast using gold cylinder, (3) laser welding, (4) soldering, and (5) electrical discharge machining, and also to measure and compare the strains produced when the order of screw tightening was changed A research model incorporating eighteen strain gages was made to measure the fit of implant frameworks in three dimensions. Three implants aligned in an arc were fixed on the top ends of the L-shape aluminum bars of the research model, and standard abutments were joined to the implants with abutment screws. Five types of implant framework were placed on the abutments and screwed by a torque wrench using 10 Ncm. Under the conditions of this study, the following conclusions were drawn: 1. The electrical discharge machining group showed the smallest magnitude of strain, followed by the soldering group, the laser welding group, the one-piece cast group using gold cylinder, and the one-piece cast group using plastic sleeve. However, among the magnitude of strain for the remaining groups except the electrical discharge machining group, there were not significant differences. 2. When the order of screw tightening was changed, there were not significant differences in the magnitude of strain. 3. In comparison with the electrical discharge machining group, the laser welding group and the one-piece cast groups showed greater horizontal distortion and the soldering group showed greater horizontal and vertical distortion.

Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

  • Jo, Jae-Young;Yang, Dong-Seok;Huh, Jung-Bo;Heo, Jae-Chan;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.491-497
    • /
    • 2014
  • PURPOSE. This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION. The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

Investigation of Power Bus Decoupling by the Screw Connection of the PCB to Chassis (나사를 이용한 기구물과 인쇄회로기판 연결이 전원단 잡음 감소에 미치는 영향 분석)

  • 권덕규;이신영;이해영;이재욱;배승민
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1040-1047
    • /
    • 2002
  • In this paper, we investigated noise decoupling on the power bus by the screw connection, used to the mechanical join and grounding of the PCB ground to chassis. The screw connection penetrates the power bus and then it affects noise propagation on the power bus. To verify effect of the screw connection, we compare bare board with board having screws connection with 0.5 mm separation between power bus and chassis. From these results, we observed that the power bus noise was decreased about 5 dB at the frequency range from 0.1 GHz to 1 GHz. Also, we verified that a 4-layer PCB with signal trace had the better signal quality up to 600 MHz by the screw connection. Therefore, these results will be useful in designing to the high speed circuit and chassis.