• Title/Summary/Keyword: Screw stability

Search Result 240, Processing Time 0.029 seconds

Analysis of Compression Behavior on Intervertebral Disc L4-5 in Pedicle Screw System Instrumented Lumbar Spine under Follower Load (척추경 나사못을 이용한 척추 유합술에서 고정범위에 따른 인접 추간판의 압축 거동 분석)

  • Ahn, Myun-Whan;Ahn, Jong-Chul;Lee, Su-Ho;Chung, Il-Sub;Lee, Choon-Yeol;Lee, Jang-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.2
    • /
    • pp.160-168
    • /
    • 2003
  • Background: Confirm the stability of intervertebral disc sustaining each fused lumbar spine cases, comparing vertical compression, A-P shear force and rotational moment on intervertebral disc of instrumented lumbar spine with simple vertical compression load and follower load using finite element analysis. Materials and Methods: We analyze the stability of intervertebral disc L4-5 supporting fused lumbar spine segments. After performing finite element modelling about L1-L5 lumbar vertebral column and L1-L4 each fusion level pedicle screw system for fused lumbar spine fine element model. Intervertebral discs with complex structure and mechanical properties was modeled using spring element that compensate stiffness and tube-to-tube contact element was employed to give follower load. Performing geometrical non-linear analysis. Results: The differences of intervertebral disc L4-5 behavior under the follower compression load in comparision with vertical compression load are as follows. Conclusion: As a result of finite element interpretation of instrumented lumbar spine, the stability of L4-5 sustaining fused lumbar segment, the long level fused lumbar spine observed hing stability under follower load. This research method can be the basis tool of effects prediction for instrumentation, a invention of a more precious finite element interpretation model which consider the role of muscle around the spine is loaded.

  • PDF

Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments (CAD/CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가)

  • Lee, Chang-Jae;Yang, Sung-Eun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the screw joint stability between the CADCAM custom-made implant abutment and the prefabricated implant abutment by measuring the reverse torque value after cyclic loading. Materials and methods: Twelve screw type implants (Implantium, Dentium Co., Seoul, Korea) were embedded in aluminum cylinder with acrylic resin. The implant specimens were equally divided into 3 groups, and connected to the prefabricated titanium abutments (Implantium, Dentium Co., Seoul, Korea), CADCAM custom-made titanium abutments (Myplant, Raphabio Co., Seoul, Korea) and CADCAM custom-made zirconia abutments (Zirconia Myplant, Raphabio Co., Seoul, Korea). The CAD-CAM milled titanium crown (Raphabio Co., Seoul, Korea) was cemented on each implant abutment by resin cement. Before cyclic loading, each abutment screw was tightened to 30 Ncm and the reverse torque value was measured about 30 minutes later. After the crown specimen was subjected to the sinusoidal cyclic loading (30 to 120 N, 500,000 cycles, 2 Hz), postloading reverse torque value was measured and the reverse torque loss ratio was calculated. Kruskal-Wallis test was used for statistical analysis of the reverse torque loss ratio. Results: The CADCAM custom-made titanium abutments presented higher values in reverse torque loss ratio without statistically significant differences than the prefabricated titanium abutments ($P$>.05). Reverse torque loss ratio of the custom-made zirconia abutments was significantly higher compared to that of the prefabricated titanium abutments ($P$=.014). Conclusion: Within the limitation of the present $in-vitro$ study, it was concluded that there was no significant difference in screw joint stability between the CADCAM custom-made titanium abutments and the prefabricated titanium abutments. On the other hand, the CADCAM custom-made zirconia abutments showed lower screw joint stability than prefabricated titanium abutments.

Position Control of Sliding Mode Control Systems with Compensation of Estimated Coulomb friction (추정된 쿨롱 마찰을 보상한 슬라이딩 모드 제어 시스템의 위치제어)

  • 김한메;최정주;이영진;김종식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.35-42
    • /
    • 2004
  • The control systems with friction cause the steady state error and slow response, because friction is a sensitive to the change of system condition and has highly nonlinear characteristics. To overcome these problems and do precise position control for a ball-screw system, we use Coulomb friction estimator and the sliding mode control(SMC) to compensate its negative effect. The applied SMC for tracking position has a characteristics of robust stability and reducing chattering, and is derived from the Lyapunov stability theorem and reaching condition. Compensating the estimated friction torque to the bounded disturbance term of the SMC's equivalent control input, it has a tracking performance better than the PID from the experimental results.

Biepicondylar Fracture of the Humerus in an Adult Female: A Case Report

  • Seong, Minkyu;Choi, Jungyun;Yum, Jaekwang
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.249-251
    • /
    • 2016
  • iepicondylar fracture of the humerus is very rare in adults. To date, there have been limited evidence of this injury in the English literature. We report a case of a 65-year-old female with a biepicondylar fracture of the left distal humerus without dislocation. Open reduction and internal fixation with K-wires, cannulated screw, and suture anchor were performed. We obtained stability of the elbow and a satisfactory functional outcome. Because this type of injury is associated with varus and valgus instability, operative reduction and fixation are essential in order to gain stability and early recovery of normal function.

Vibration reduction of a pipe conveying fluid using the semi-active electromagnetic damper

  • Kavianipour, Omid
    • Coupled systems mechanics
    • /
    • v.6 no.2
    • /
    • pp.175-187
    • /
    • 2017
  • This paper deals with a uniform cantilever Euler-Bernoulli beam subjected to follower and transversal force at its free end as a model for a pipe conveying fluid under electromagnetic damper force. The electromagnetic damper is composed of a permanent-magnet DC motor, a ball screw and a nut. The main objective of the current work is to reduce the pipe vibration resulting from the fluid velocity and allow it to transform into electric energy. To pursue this goal, the stability and vibration of the beam model was studied using Ritz and Newmark methods. It was observed that increasing the fluid velocity results in a decrease in the motion of the free end of the pipe. The results of simulation showed that the designed semiactive electromagnetic damper controlled by on-off damping control strategy decreased the vibration amplitude of the pipe about 5.9% and regenerated energy nearly 1.9 (mJ/s). It was also revealed that the designed semi-active electromagnetic damper has better performance and more energy regeneration than the passive electromagnetic damper.

Studies on the Surface Properties of PMMA after Accelerated Weathering

  • Kwon, Young Bum;Ha, Jin Uk;Hwang, Ye Jin;Oh, Jeong Seok
    • Elastomers and Composites
    • /
    • v.51 no.4
    • /
    • pp.350-354
    • /
    • 2016
  • The surface properties of poly(methyl methacrylate) (PMMA) were investigated after accelerated weathering. Glossinesses, contact angles, surface free energies, thermal stability, and mechanical properties were investigated. The glossiness of the weathered PMMA was decreased with increasing exposure time. Contact angles and surface free energies were not overtly changed because the amount of oxygen on the surface was remained. PMMA was compounded with anti-block and antistatic agents using a co-rotating twin screw extruder to improve the durability. The PMMA composites showed better glossinesses after accelerated weathering while maintaining the contact angles, surface energy, thermal stability, and mechanical properties without significant changes.

Effect of MMT on Anti-Water Absorption of Polyamide/MMT Nanocomposites (MMT 첨가에 따른 Polyamide/MMT 나노복합체의 흡습 특성)

  • Park, Sang-Cheol;Kim, Ho-Gyum;Min, Kyung-Eun
    • Polymer(Korea)
    • /
    • v.37 no.1
    • /
    • pp.113-120
    • /
    • 2013
  • The melt intercalation to commercialize nanocomposites in a pilot scale was applied and the water absorption characteristics for polyamide/MMT nanocomposites manufactured by twin screw extruder was studied. As a result, water absorption decreased with the introduction of MMT and dimensional stability was improved. However, as water absorption increased, flexural strength and modulus were reduced. Therefore, the effect of MMT introduction on mechanical properties of nanocomposites was clearly observed, which may increase the level of strength by maintaining anti-water absorption property of nanocomposite.

A Numerical Study for the Variation of Cortical Bone Thickness with Several Dental Implants (인공치아에 있어 피질골의 두께 변화가 미치는 영향에 관한 연구)

  • Choi, J.B.;Moon, H.J.;Choi, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.323-326
    • /
    • 1996
  • Dental implant is increasingly used to recover the mastication function of tooth. Several types of implant were designed to give an optimal stress distribution in surrounding bony regions. In this study, six types of implant were investigated using finite element method and it was studied i) how the variation of cortical bone thickness affects the stress distribution in surrounding bony regions depending upon implant types, ii) which type gives the best characteristics in the sence of stress distribution and stability. The hybrid-type implant with cylinder and screw gave the optimum properties in view of stability and response to the variation of cortical bone thickness.

  • PDF

A Study on Improvement of the Thermal Stability for Development of Linear Motors with High Speed and Accuracy (고속.정밀 이송용 리니어모터 개발을 위한 열적 안정성 향상에 관한 연구)

  • Hwang, Young-Kug;Lee, Choon-Man;Eun, In-Ung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.126-133
    • /
    • 2008
  • Linear motors are efficient mechanism that offers high speed and positioning accuracy. By eliminating mechanical transmission mechanisms such as ball screw or rack-pinion, much higher speed and greater acceleration can be achieved without backlash or excessive friction. However, an important disadvantage of linear motor system is its high power loss and heating up of motor and neighboring machine components on operation. For the application of the linear motors to precision machine tools an effective cooling method and thermal optimizing measures are required. This paper presents an investigation into the thermal behavior of linear motors with the objective of deriving the optimum cooling conditions. To reach these goals several experiments were carried out, varying operating and cooling conditions. From the experimental results, this research proposed cooling conditions to improve the thermal characteristics of the linear motors.

A Study of mechanical properties of oxide layer removed Co-Cr-Mo abutments

  • Ryu, Jae-ho;Huh, Jung-Bo;Ro, Jung-Hoon;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.11
    • /
    • pp.804-816
    • /
    • 2015
  • PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implant-abutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.