A Numerical Study for the Variation of Cortical Bone Thickness with Several Dental Implants

인공치아에 있어 피질골의 두께 변화가 미치는 영향에 관한 연구

  • Choi, J.B. (Biomedical Research Center, Korea Institute of Science and Technology) ;
  • Moon, H.J. (Biomedical Research Center, Korea Institute of Science and Technology) ;
  • Choi, K. (Biomedical Research Center, Korea Institute of Science and Technology)
  • 최재봉 (한국과학기술연구원 의과학연구센터) ;
  • 문항진 (한국과학기술연구원 의과학연구센터) ;
  • 최귀원 (한국과학기술연구원 의과학연구센터)
  • Published : 1996.11.15

Abstract

Dental implant is increasingly used to recover the mastication function of tooth. Several types of implant were designed to give an optimal stress distribution in surrounding bony regions. In this study, six types of implant were investigated using finite element method and it was studied i) how the variation of cortical bone thickness affects the stress distribution in surrounding bony regions depending upon implant types, ii) which type gives the best characteristics in the sence of stress distribution and stability. The hybrid-type implant with cylinder and screw gave the optimum properties in view of stability and response to the variation of cortical bone thickness.